HomeMy WebLinkAboutC6.00 Overall Utility Plan V1DESK
WORK BENCH
COMP
RESSOR
SHELVES
CABINETRY
CABINETRY CABINETRY
CABI
NETRY CABINE
TRY
C/H WATER SUPPLY
DRY
VENT?
(REPAIRS)
GOL
F CART
CHARGER
WALL M
OUNTED
HEATER?
W/H
ABOVE
F
IRE RISER
ACCESSIBLE
WASH TUB
W/ STEPS
UGP
UGP
UGP
UGP
UGP
UGP UGP
UGP
UGP
UGP UGP UGP
UGP
UGP
UGP
UGP
T
T
T T
T T T
T
T
T T T T T
T
T T T T
T T T T T T T T T T T
T T
T T
T
T
T
G G
G
G
G G
G
G
G
G G
G
G
G
T T
T T
UGP
T
T
T
SD
R/W R/W R/W
H
G
D D
D
T
T
SS SS
SS SS
W
W
SS
W
EG
X X
X
X X X
X
X X X X X X X X X
X X
X
X X
X X X
X X
X X X
EG
TOP
TOP
TOP
TOP
TOP TOP
FL FL FL
SS SS SS SS SS SS SS SS
SS SS SS SS
SS SS SS
SS
SS SS SS
SS
SS
SS
SS SS
OHP OHP OHP
OHP OHP
OHP OHP OHP OHP OHP
OHP
OHP
OHP
OHP
OHP
OHP
OHP
W
W W W W W W W W
W
W
W W W
W W W
W W W
W
W W
W W
W
W W W W
W
W W
W W
G G
G G G
G
G G G
G G G
G G G
G
G
G G G G
G
G G
G
G G G G G
E
E
E
E
E
E
E
E
EE
S
S
S
WV
WV
W
W
WV
WV
WV
IRR
SAN
IV
IV
IRR
T
C
IV
IV IV
E
IV
E
E
E
IV
IRR
OS
OS
WV
OS OS
OS
OS
IV
IV
CO
RD
CO RD
T
TT
T
T
T
T
EE
T
EE
OS
OS
WV
OS
OS
S
D
W W
S
S
T
8''W
8''W 8''W 8''W 8''W 8''W
8''W
8''W 8''W
8''W 8''W 8''W
8''W 8''W 8''W 8''W 8''W
8''W
8''W
8''W
8''W
8''W
SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
SS SS SS SS SS SS SS SS SS SS SS SS SS
R/W R/W R/W R/W R/W R/W R/W
R/W
R/W R/W R/W R/W
R/W
R/W
8''W 8''W 8''W 8''W 8''W 8''W
8''W
GIRR GIRR GIRR GIRR GIRR
GIRR
GIRR GIRR
G
IRR
GIRR
GIRR
GIRR
GIRR GIRR
GIRR
GMTR
SS SS SS SS SS SS SS SS SS
SAN
SAN
SAN
SAN
SAN
SAN
MTR
MTR
FS
MTR
MTR
FS
MTR
FS
8''W 8''W 8''W
FS
MTR
FS
MTR MTR
FS
MTR
FS
FS SAN
MTR
6''SS CO 6''SS CO
CO CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
CO
MTR
8''W 8''W 8''W 8''W
8''W
8''W
GIRR
GIRR
UGP UGP
UGP UGP
SAN
12''SD12''SD12''SD
12''SD
12''SD 12''SD
12''SD
12''SD
12''SD12''SD
12''SD
12''SD 12''SD
12''SD 12''SD
12''SD 12''SD
12''SD
12''SD
12''SD
12''SD
SD
SD
SD
18''SD
12''SD
8''SD
8''SD
8''SD
8''SD
8''SD
8''SD
8''SD
8''SD 8''SD
8''SD
8''SD
8''SD
8''SD
8''SD
12''SD12''SD
8''SD
8''SD 8''SD
8''SD
8''SD
8''SD
MW
SD
MW
MTR
MTR
8''SD
CO
GIRR
GIRR GIRR
GIRR
GIRR GIRR
GIRR
EP
SD
CO
R/W R/W R/W R/W R/W R/W R/W
R/W
R/W
R/W
SAN
CO
MW
SAN
MW
MW
EP
EP
MTR
MTR
MTR
MTR
MTR
MTR
MTR
MTR
MTR
MTR
CO
MTR
MTR
FS
6
6
6
6
6
6
6
6 6
6
6
5
5
2
12
12
1
1.1
1
6
4
1
1
1.1
2
2
2
2
1
2
2
2
2
2
2
7
7
7
7
7
2&3
2&3
3
2
11
11
2
2&8
4
4
4
10
2&4
1
2
WELLS
NORTH
NORTH
SOUTH
MAIN
OVERLAND ROAD
OVERLAND ROAD
34-LF 8-IN C900
61-LF 8-IN C900
33-LF 8-IN C900
73-LF 8-IN C900
22-LF 8-IN C900
C6.01
C6.02
C6.03
C6.04
1
2
1
1
5 2 5
13
6
15
13
7
2&9
2&8
1
13
7
13
13
1
1
1
1
13
13
7
7
2&8
1
13
13
7
2
13
14
14
52-LF 8-IN C900
60-LF 8-IN C900
324-LF 8-IN C900
2&8
1
1
1
1
1 1
135-LF 8-IN C900
139-LF 8-IN C900
51-LF 8-IN C900
28-LF 8-IN C900
1 1
2
16
66-LF 8-IN C900
5
1 1
1
225-LF 8-IN C900
1
1
1
1
1
1
247-LF 8-IN C900
23-LF 8-IN C900
MAIN
1
1
1 1
1
2
2 2
122-LF 8-IN C900
24-LF 8-IN C900
36-LF 8-IN C900 6-LF 8-IN C900
1
1
3
3
3
1 1
3
3
3
3 3
3
3
3 3
3
3
3
3
110-LF 8-IN C900
2
2
2
I-84 EXIT 46
SOUTH WELLS AVENUE
EAST OVERLAND ROAD
52-LF 4-IN PE
14-LF 6-IN C900
44-LF 8-IN C900
20-LF 6-IN C900
109-LF 8-IN C900
37-LF 6-IN C900
239-LF 8-IN C900
42-LF 6-IN C900
26-LF 6-IN C900
24-LF 6-IN C900
248-LF 8-IN C900 15-LF 8-IN C900
9-LF 8-IN C900
25-LF 8-IN C900
9-LF 8-IN C900
26-LF 8-IN C900
1.1
51-LF 6-IN C900
18-LF 6-IN C900
32-LF 4-IN PE
51-LF 6-IN C900
15-LF 6-IN C900
31-LF 6-IN C900
47-C900LF 6-IN C900 55-LF 6-IN
32-LF 6-IN C900
55-LF 6-IN C900
39-LF 6-IN C900
46-LF 6-IN C900
28-LF 6-IN C900
38-LF 6-IN C900
48-LF 2-IN PE
51-LF 2-IN PE
48-LF 2-IN PE
34-LF 2-IN PE
47-LF 2-IN PE
44-LF 1-IN PE
47-LF 2-IN PE
34-LF 2-IN PE
40-LF 2-IN PE 43-LF 2-IN PE 40-LF 2-IN PE
36-LF 6-IN SS
36-LF 6-IN SS
36-LF 6-IN SS
42-LF 6-IN SS
44-LF 6-IN SS
36-LF 6-IN SS
43-LF 6-IN SS
43-LF 6-IN SS
95-LF 6-IN SS 90-LF 6-IN SS
90-LF 6-IN SS
43-LF 6-IN SS
44-LF 6-IN SS
52-LF 4-IN SS
26-LF 4-IN SS
15-LF 4-IN SS
64-LF 4-IN SS
11-LF 8-IN C900
11
34-LF 8-IN C900
223-LF 8-IN C900
1
49-LF 8-IN C900
137-LF 8-IN C900
56-LF 8-IN C900
229-LF 8-IN C900
54-LF 8-IN C900
72-LF 8-IN C900
11
51-LF 8-IN C900
166-LF 8-IN C900
137-LF 8-IN C900
7-LF 8-IN C900
11
218-LF 8-IN C900
11
136-LF 8-IN C900 133-LF 8-IN C900
146-LF 8-IN C900
10-LF 8-IN C900
15
13
A
A
13
13
64-LF 2-IN PE
34-LF 2-IN PE
2&8
6
2
16-LF 6-IN C900
2
24-LF 6-IN C900
20-LF 6-IN C900
1
6
2
A
A
8-LF 8-IN C900
A
37-LF 8-IN C900
A
Horizontal Scale:
0 40' 80'
1" = 40'
Overall Utility Plan
20213
3 1 0 0 B R I S T O L S T R E E T , S U I T E 4 0 0
C O S T A M E S A , C6 A 9 2 6 2
W W W . N G G P A R T N E R S . C O M
T 9 4 9 . 7 5 6 . 0 8 1 8 F 9 4 9 . 7 5 6 . 0 1 4 5
A R C H I T E C T U R E ● P L A N N I N G ● I N T E R I O R S
REV DESCRIPTION DATE
2700 E. Overland Rd.
Meridian, ID 83642
SEASONS AT MERIDIAN
NEWMAN GARRISON + PARTNERS, INC
COPY RIGHT 2019 NEWMAN GARRISON + PARTNERS
MORGAN HOLDINGS &
STONE HILL
38 Glen Gary Dr., Ste. 200
Aspen, CO 81611
7301 Peak Dr., Ste. 200
Las Vegas, NV 89128
TLG PN:120124
A DELTA A 07/22/2022
# Legend:
W
SS SS
SAN
WATER MAIN
SANITARY SEWER MAIN
SANITARY SEWER MANHOLE
SANITARY SEWER CLEANOUT
FIRE HYDRANT
WATER MAIN VALVE
BLOWOFF HYDRANT
THRUST BLOCK
GASKETED CAP
C6.00
Overall Utility
Plan
Sheet Notes:
1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CURB & GUTTER, STORM DRAIN,
CHANNEL CROSSINGS, & SEWER ELEVATIONS OR INVERTS PRIOR TO CONSTRUCTION
AND NOTIFY ENGINEER WHEN ELEVATIONS OR INVERTS DO NOT MATCH PLANS.
2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN APPROXIMATE
LOCATIONS. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL
EXISTING UTILITIES BEFORE COMMENCING WORK. CONTRACTOR AGREES TO BE
FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR BY FAILURE
TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.
3. CONTRACTOR TO VERIFY THE DEFLECTION ANGLE FOR ALL WATER UTILITIES AND
NOTIFY ENGINEER WHEN ANGLE DOES NOT MATCH PLANS.
4. NO PERMANENT STRUCTURES ARE ALLOWED WITHIN AN EASEMENT OR OVER A
WATER MAIN. THIS INCLUDES BUILDINGS, CARPORTS, TRASH ENCLOSURES, TREES,
DEEP-ROOTING BUSHES, ETC.
Water Keynotes:
1. POTABLE WATER MAIN/SERVICE OR SERVICE/SERVICE CROSSING - SEE WATER NOTE NO. 3 ON SHEET C0.00 AND IDAHO
STATE PLUMBING CODE FOR SEPARATION REQUIREMENTS.
1.1. POTABLE/NON-POTABLE MAIN CROSSING - SEE WATER NOTE NO. 2 ON SHEET C0.00 AND IDAHO STATE PLUMBING
CODE FOR SEPARATION REQUIREMENTS.
2. INSTALL THRUST BLOCK PER ISPWC SD-403.
3. INSTALL 8-IN 11.25-DEGREE (MJ x MJ) BEND.
4. INSTALL 8-IN x 8-IN (MJ x FL) TEE AND TWO (2) 8-IN (FL x MJ) GATE VALVES.
5. INSTALL 2-IN BLOWOFF ASSEMBLY (FUTURE WATER MAIN EXTENSION) PER CITY OF MERIDIAN STANDARD DRAWING W13.
6. INSTALL FIRE HYDRANT ASSEMBLY PER CITY OF MERIDIAN STANDARD DRAWING W8.
7. INSTALL TWO (2) 2-INCH WATER SERVICE CONNECTIONS PER CITY OF MERIDIAN STANDARD DRAWING W4. MANIFOLD
SERVICE LINES DOWNSTREAM OF METERS TO A SINGLE 4-INCH LINE. SEE MECHANICAL FOR CONTINUATION INTO
BUILDING, PROVIDE AND INSTALL TRANSITION FITTING AS REQUIRED.
8. INSTALL 8-IN 45-DEGREE (MJ x MJ) BEND.
9. INSTALL 8-IN 22.5-DEGREE (MJ x MJ) BEND.
10. INSTALL 8-IN x 8-IN (MJ x FL) CROSS AND THREE (3) 8-IN (FL x MJ) GATE VALVES.
11. INSTALL ONE (1) 8-IN (MJ x MJ) GATE VALVE.
12. CONNECT TO EXISTING WATER MAIN STUB AT THIS APPROXIMATE LOCATION WITH 10-IN X 8-IN REDUCER.
13. INSTALL FIRE SERVICE (SIZE PER FIRE SPRINKLER DESIGN) WITH TEE, GATE VALVE AND THRUST BLOCK PER ISPWC
SD-403 OR CITY OF MERIDIAN STANDARD DRAWING W11 AS APPROPRIATE.
14. INSTALL 4-IN IRRIGATION SERVICE CONNECTION, METER AND VAULT PER CITY OF MERIDIAN STANDARD DRAWING W5,
REFER TO LANDSCAPE DRAWINGS FOR BACKFLOW PREVENTION AND LANDSCAPE IRRIGATION SERVICE.
15. INSTALL 1-IN PE WATER SERVICE AND METER PER CITY OF MERIDIAN STANDARD DRAWING W2.
16. INSTALL 2-IN PE WATER SERVICE AND METER PER CITY OF MERIDIAN STANDARD DRAWING W4.
Sewer Keynotes: #
1. INSTALL STANDARD 48-IN SANITARY SEWER MANHOLE TYPE A PER
ISPWC SD-501, SEE PLAN AND PROFILE DRAWINGS FOR MORE
INFORMATION.
2. INSTALL 8-IN SDR 35 PVC GRAVITY SEWER PIPE PER ISPWC DIVISION
500, SEE PLAN AND PROFILE DRAWINGS FOR MORE INFORMATION.
3. INSTALL 4-IN CLEANOUT PER ISPWC SD-506A.
4. CONNECT TO EXISTING SANITARY SEWER MAIN STUB, MATCH
INVERT ELEVATION OF EXISTING PIPE, INFORM ENGINEER OF ANY
DISCREPANCIES. SEE PLAN AND PROFILE DRAWINGS FOR MORE
INFORMATION.
5. INSTALL STANDARD 60-IN SANITARY SEWER MANHOLE TYPE B PER
ISPWC SD-502, SEE PLAN AND PROFILE DRAWINGS FOR MORE
INFORMATION.
6. INSTALL SANITARY SEWER PIPING TO LOCATION SHOWN FOR
FUTURE GRAVITY SEWER CONNECTION, INSTALL "T" TYPE CLEANOUT
PER CITY OF MERIDIAN STANDARD DRAWING S1.
CO
07-22-2022 (100% CD)
A
A
0 8/8 3// 22 0 3 / 2 2
08/03/2022
09/27/22
FPS-2022-0022