Loading...
HomeMy WebLinkAboutC6.00 Overall Utility Plan V1DESK WORK BENCH COMP RESSOR SHELVES CABINETRY CABINETRY CABINETRY CABI NETRY CABINE TRY C/H WATER SUPPLY DRY VENT? (REPAIRS) GOL F CART CHARGER WALL M OUNTED HEATER? W/H ABOVE F IRE RISER ACCESSIBLE WASH TUB W/ STEPS UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP UGP T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T G G G G G G G G G G G G G G T T T T UGP T T T SD R/W R/W R/W H G D D D T T SS SS SS SS W W SS W EG X X X X X X X X X X X X X X X X X X X X X X X X X X X X X EG TOP TOP TOP TOP TOP TOP FL FL FL SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E EE S S S WV WV W W WV WV WV IRR SAN IV IV IRR T C IV IV IV E IV E E E IV IRR OS OS WV OS OS OS OS IV IV CO RD CO RD T TT T T T T EE T EE OS OS WV OS OS S D W W S S T 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 8''W 8''W 8''W 8''W 8''W 8''W 8''W GIRR GIRR GIRR GIRR GIRR GIRR GIRR GIRR G IRR GIRR GIRR GIRR GIRR GIRR GIRR GMTR SS SS SS SS SS SS SS SS SS SAN SAN SAN SAN SAN SAN MTR MTR FS MTR MTR FS MTR FS 8''W 8''W 8''W FS MTR FS MTR MTR FS MTR FS FS SAN MTR 6''SS CO 6''SS CO CO CO CO CO CO CO CO CO CO CO CO CO CO CO MTR 8''W 8''W 8''W 8''W 8''W 8''W GIRR GIRR UGP UGP UGP UGP SAN 12''SD12''SD12''SD 12''SD 12''SD 12''SD 12''SD 12''SD 12''SD12''SD 12''SD 12''SD 12''SD 12''SD 12''SD 12''SD 12''SD 12''SD 12''SD 12''SD 12''SD SD SD SD 18''SD 12''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD 12''SD12''SD 8''SD 8''SD 8''SD 8''SD 8''SD 8''SD MW SD MW MTR MTR 8''SD CO GIRR GIRR GIRR GIRR GIRR GIRR GIRR EP SD CO R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W SAN CO MW SAN MW MW EP EP MTR MTR MTR MTR MTR MTR MTR MTR MTR MTR CO MTR MTR FS 6 6 6 6 6 6 6 6 6 6 6 5 5 2 12 12 1 1.1 1 6 4 1 1 1.1 2 2 2 2 1 2 2 2 2 2 2 7 7 7 7 7 2&3 2&3 3 2 11 11 2 2&8 4 4 4 10 2&4 1 2 WELLS NORTH NORTH SOUTH MAIN OVERLAND ROAD OVERLAND ROAD 34-LF 8-IN C900 61-LF 8-IN C900 33-LF 8-IN C900 73-LF 8-IN C900 22-LF 8-IN C900 C6.01 C6.02 C6.03 C6.04 1 2 1 1 5 2 5 13 6 15 13 7 2&9 2&8 1 13 7 13 13 1 1 1 1 13 13 7 7 2&8 1 13 13 7 2 13 14 14 52-LF 8-IN C900 60-LF 8-IN C900 324-LF 8-IN C900 2&8 1 1 1 1 1 1 135-LF 8-IN C900 139-LF 8-IN C900 51-LF 8-IN C900 28-LF 8-IN C900 1 1 2 16 66-LF 8-IN C900 5 1 1 1 225-LF 8-IN C900 1 1 1 1 1 1 247-LF 8-IN C900 23-LF 8-IN C900 MAIN 1 1 1 1 1 2 2 2 122-LF 8-IN C900 24-LF 8-IN C900 36-LF 8-IN C900 6-LF 8-IN C900 1 1 3 3 3 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 110-LF 8-IN C900 2 2 2 I-84 EXIT 46 SOUTH WELLS AVENUE EAST OVERLAND ROAD 52-LF 4-IN PE 14-LF 6-IN C900 44-LF 8-IN C900 20-LF 6-IN C900 109-LF 8-IN C900 37-LF 6-IN C900 239-LF 8-IN C900 42-LF 6-IN C900 26-LF 6-IN C900 24-LF 6-IN C900 248-LF 8-IN C900 15-LF 8-IN C900 9-LF 8-IN C900 25-LF 8-IN C900 9-LF 8-IN C900 26-LF 8-IN C900 1.1 51-LF 6-IN C900 18-LF 6-IN C900 32-LF 4-IN PE 51-LF 6-IN C900 15-LF 6-IN C900 31-LF 6-IN C900 47-C900LF 6-IN C900 55-LF 6-IN 32-LF 6-IN C900 55-LF 6-IN C900 39-LF 6-IN C900 46-LF 6-IN C900 28-LF 6-IN C900 38-LF 6-IN C900 48-LF 2-IN PE 51-LF 2-IN PE 48-LF 2-IN PE 34-LF 2-IN PE 47-LF 2-IN PE 44-LF 1-IN PE 47-LF 2-IN PE 34-LF 2-IN PE 40-LF 2-IN PE 43-LF 2-IN PE 40-LF 2-IN PE 36-LF 6-IN SS 36-LF 6-IN SS 36-LF 6-IN SS 42-LF 6-IN SS 44-LF 6-IN SS 36-LF 6-IN SS 43-LF 6-IN SS 43-LF 6-IN SS 95-LF 6-IN SS 90-LF 6-IN SS 90-LF 6-IN SS 43-LF 6-IN SS 44-LF 6-IN SS 52-LF 4-IN SS 26-LF 4-IN SS 15-LF 4-IN SS 64-LF 4-IN SS 11-LF 8-IN C900 11 34-LF 8-IN C900 223-LF 8-IN C900 1 49-LF 8-IN C900 137-LF 8-IN C900 56-LF 8-IN C900 229-LF 8-IN C900 54-LF 8-IN C900 72-LF 8-IN C900 11 51-LF 8-IN C900 166-LF 8-IN C900 137-LF 8-IN C900 7-LF 8-IN C900 11 218-LF 8-IN C900 11 136-LF 8-IN C900 133-LF 8-IN C900 146-LF 8-IN C900 10-LF 8-IN C900 15 13 A A 13 13 64-LF 2-IN PE 34-LF 2-IN PE 2&8 6 2 16-LF 6-IN C900 2 24-LF 6-IN C900 20-LF 6-IN C900 1 6 2 A A 8-LF 8-IN C900 A 37-LF 8-IN C900 A Horizontal Scale: 0 40' 80' 1" = 40' Overall Utility Plan 20213 3 1 0 0 B R I S T O L S T R E E T , S U I T E 4 0 0 C O S T A M E S A , C6 A 9 2 6 2 W W W . N G G P A R T N E R S . C O M T 9 4 9 . 7 5 6 . 0 8 1 8 F 9 4 9 . 7 5 6 . 0 1 4 5 A R C H I T E C T U R E ● P L A N N I N G ● I N T E R I O R S REV DESCRIPTION DATE 2700 E. Overland Rd. Meridian, ID 83642 SEASONS AT MERIDIAN NEWMAN GARRISON + PARTNERS, INC COPY RIGHT 2019 NEWMAN GARRISON + PARTNERS MORGAN HOLDINGS & STONE HILL 38 Glen Gary Dr., Ste. 200 Aspen, CO 81611 7301 Peak Dr., Ste. 200 Las Vegas, NV 89128 TLG PN:120124 A DELTA A 07/22/2022 # Legend: W SS SS SAN WATER MAIN SANITARY SEWER MAIN SANITARY SEWER MANHOLE SANITARY SEWER CLEANOUT FIRE HYDRANT WATER MAIN VALVE BLOWOFF HYDRANT THRUST BLOCK GASKETED CAP C6.00 Overall Utility Plan Sheet Notes: 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CURB & GUTTER, STORM DRAIN, CHANNEL CROSSINGS, & SEWER ELEVATIONS OR INVERTS PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER WHEN ELEVATIONS OR INVERTS DO NOT MATCH PLANS. 2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN APPROXIMATE LOCATIONS. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. CONTRACTOR AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR BY FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. 3. CONTRACTOR TO VERIFY THE DEFLECTION ANGLE FOR ALL WATER UTILITIES AND NOTIFY ENGINEER WHEN ANGLE DOES NOT MATCH PLANS. 4. NO PERMANENT STRUCTURES ARE ALLOWED WITHIN AN EASEMENT OR OVER A WATER MAIN. THIS INCLUDES BUILDINGS, CARPORTS, TRASH ENCLOSURES, TREES, DEEP-ROOTING BUSHES, ETC. Water Keynotes: 1. POTABLE WATER MAIN/SERVICE OR SERVICE/SERVICE CROSSING - SEE WATER NOTE NO. 3 ON SHEET C0.00 AND IDAHO STATE PLUMBING CODE FOR SEPARATION REQUIREMENTS. 1.1. POTABLE/NON-POTABLE MAIN CROSSING - SEE WATER NOTE NO. 2 ON SHEET C0.00 AND IDAHO STATE PLUMBING CODE FOR SEPARATION REQUIREMENTS. 2. INSTALL THRUST BLOCK PER ISPWC SD-403. 3. INSTALL 8-IN 11.25-DEGREE (MJ x MJ) BEND. 4. INSTALL 8-IN x 8-IN (MJ x FL) TEE AND TWO (2) 8-IN (FL x MJ) GATE VALVES. 5. INSTALL 2-IN BLOWOFF ASSEMBLY (FUTURE WATER MAIN EXTENSION) PER CITY OF MERIDIAN STANDARD DRAWING W13. 6. INSTALL FIRE HYDRANT ASSEMBLY PER CITY OF MERIDIAN STANDARD DRAWING W8. 7. INSTALL TWO (2) 2-INCH WATER SERVICE CONNECTIONS PER CITY OF MERIDIAN STANDARD DRAWING W4. MANIFOLD SERVICE LINES DOWNSTREAM OF METERS TO A SINGLE 4-INCH LINE. SEE MECHANICAL FOR CONTINUATION INTO BUILDING, PROVIDE AND INSTALL TRANSITION FITTING AS REQUIRED. 8. INSTALL 8-IN 45-DEGREE (MJ x MJ) BEND. 9. INSTALL 8-IN 22.5-DEGREE (MJ x MJ) BEND. 10. INSTALL 8-IN x 8-IN (MJ x FL) CROSS AND THREE (3) 8-IN (FL x MJ) GATE VALVES. 11. INSTALL ONE (1) 8-IN (MJ x MJ) GATE VALVE. 12. CONNECT TO EXISTING WATER MAIN STUB AT THIS APPROXIMATE LOCATION WITH 10-IN X 8-IN REDUCER. 13. INSTALL FIRE SERVICE (SIZE PER FIRE SPRINKLER DESIGN) WITH TEE, GATE VALVE AND THRUST BLOCK PER ISPWC SD-403 OR CITY OF MERIDIAN STANDARD DRAWING W11 AS APPROPRIATE. 14. INSTALL 4-IN IRRIGATION SERVICE CONNECTION, METER AND VAULT PER CITY OF MERIDIAN STANDARD DRAWING W5, REFER TO LANDSCAPE DRAWINGS FOR BACKFLOW PREVENTION AND LANDSCAPE IRRIGATION SERVICE. 15. INSTALL 1-IN PE WATER SERVICE AND METER PER CITY OF MERIDIAN STANDARD DRAWING W2. 16. INSTALL 2-IN PE WATER SERVICE AND METER PER CITY OF MERIDIAN STANDARD DRAWING W4. Sewer Keynotes: # 1. INSTALL STANDARD 48-IN SANITARY SEWER MANHOLE TYPE A PER ISPWC SD-501, SEE PLAN AND PROFILE DRAWINGS FOR MORE INFORMATION. 2. INSTALL 8-IN SDR 35 PVC GRAVITY SEWER PIPE PER ISPWC DIVISION 500, SEE PLAN AND PROFILE DRAWINGS FOR MORE INFORMATION. 3. INSTALL 4-IN CLEANOUT PER ISPWC SD-506A. 4. CONNECT TO EXISTING SANITARY SEWER MAIN STUB, MATCH INVERT ELEVATION OF EXISTING PIPE, INFORM ENGINEER OF ANY DISCREPANCIES. SEE PLAN AND PROFILE DRAWINGS FOR MORE INFORMATION. 5. INSTALL STANDARD 60-IN SANITARY SEWER MANHOLE TYPE B PER ISPWC SD-502, SEE PLAN AND PROFILE DRAWINGS FOR MORE INFORMATION. 6. INSTALL SANITARY SEWER PIPING TO LOCATION SHOWN FOR FUTURE GRAVITY SEWER CONNECTION, INSTALL "T" TYPE CLEANOUT PER CITY OF MERIDIAN STANDARD DRAWING S1. CO 07-22-2022 (100% CD) A A 0 8/8 3// 22 0 3 / 2 2 08/03/2022 09/27/22 FPS-2022-0022