A4.2 - Elevations V1DwRIDI 9- APPROVED Im osrzsrzz IUD a RIGHT ELEVATION REAR ELEVATION SCALE: 1/4" = 1'-0" SHEET NOTES A. ALL VERTICAL DIMENSIONS SHOWN ARE FROM THE INTERIOR CONCRETE FLOOR SLAB AT THE FIRST FLOOR OR TOP OF SHEATHING AT THE UPPER FLOORS FLOOR. B. REFER TO DETAILS FOR MINIMUM WINDOW, DOOR AND WALL VENT MOISTURE BARRIER INSTALLATION REQUIREMENTS. C. PROVIDE TWO (2) LAYERS OF MIN. GRADE "D" BUILDING PAPER AT WOOD SHEATHED WALLS RECEIVING EXTERIOR PLASTER. D. ALL HORIZONTAL SURFACES WILL RECEIVE BUILDING PAPER OVER HEAT RESISTANT SELF ADHERING, SELF SEALING FLASHING WEATHER BOARD LAPPED 6" MINIMUM WITH BUILDING PAPER PRIOR TO THE APPLICATION OF WIRE LATH AND PLASTER. E. ALL STUD WALLS & CEILINGS EXTENDING INTO A SOFFIT WILL BE PREBOARDED WITH GYP -BD PRIOR TO SOFFIT INSTALLATIONS. F. DUCT TERMINATIONS TO OCCUR PER APPLIANCE MANUFACTURERS REQUIREMENTS VERIFY DISTANCE FROM WINDOW OR DOOR OPENINGS INTO DWELLING UNIT. KEYNOTES ETiROOF MATERIAL: MANUFACTURED COMPOSITION SHINGLE ROOF TILES - FLAT. REFER TO BUILDER'S SPECS FOR MANUF. AND COLORS. FIBER CEMENT LAP SIDING WITH SMOOTH FINISH, 6" EXPOSURE AND CORNER BOARD TRIM. REFER TO BUILDER'S SPECS FOR MANUF. AND COLORS. FIBER CEMENT VERTICAL SIDING. REFER TO BUILDER'S SPECS FOR MANUF. AND COLORS. ® BOARD AND BATTENS - 5/4x2 FIBER CEMENT, SMOOTH FINISHI2' O.C. ADHERED STONE VENEER. REFER TO BUILDER'S MANUF. AND COLORS. INSTALL PER MANUF. INSTRUCTIONS. © FIBER CEMENT TRIM. REFER TO ELEVATIONS FOR SIZES. �7 THIN BRICK ROWLOCK COURSE. INSTALL PER MANUFACTURER'S INSTRUCTIONS A. VENTED ATTICS: PER IRC SEC. R806.2.1 THE MINIMUM NET VENT. AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE EXCEPTION: THE MIN NET FREE VENT AREA SHALL BE 1 /300 OF THE AREA OF THE VENTED SPACE PROVIDED BOTH OF THE FOLLOWING ARE MET: 1. IN CLIMATE ZONES 14 & 16, A CLASS 1 OR 11 VAPOR RETARDER IS INSTALLED ON THE WARN -IN -WINTER SIDE OF THE CEILING. 2. NOT LESS THAN 40%AND NOT MORE THAN 507.OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FT. BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY. THE BALANCE OF THE REQUIRED VENTILATION SHALL BE LOCATED IN THE BOTTOM ONE-THIRD OF THE ATTIC SPACE. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FT. BELOW THE RIDGE OF HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. FLAT TILE ROOFS SHALL BE VENTILATED ACCORDING TO THE FOLLOWING: ATTIC AREA VENT RATIO 1/300 (S.F.) (FLAT TILE) 0 - 406 (2) VENTS - O'HAGIN STANDARD (2 x 97.50 S.I. / 144 S.I. x 300 S.F.) 407 812 (4) VENTS - O'HAGIN STANDARD (4 x 97.50 S.I. / 144 S.I. x 300 S.F.) 813 1218 (6) VENTS - O'HAGIN STANDARD (6 x 97.50 S.I. / 144 S.I. x 300 S.F.) 1219 - 1625 (8) VENTS - O'HAGIN STANDARD (8 x 97.50 S.I. / 144 S.I. x 300 S.F.) 1626-2031 (10)VENTS- O'HAGIN STANDARD (10 x 97.50 S.I. / 144 S.I. x 300 S.F.) ATTIC AREA VENT RATIO 1/150 (S.F.) (FLAT TILE) (2) VENTS - O'HAGIN STANDARD 0 - 203 (2 x 97.50 S.I. / 144 S.I. x 150 S.F.) (4)VENTS- O'HAGIN STANDARD 204-406 (4 x 97.50 S.I. / 144 S.I. x 150 S.F.) (6)VENTS- O'HAGIN STANDARD 407-609 (6 x 97.50 S.I. / 144 S.I. x 150 S.F.) NOTE: ALL VENTILATION CALCULATIONS ARE BASED ON VENTS WITH 97.50 SQ. IN. NET FREE VENT AREA AS PROVIDED BY O'HAGIN PRODUCTS ('S" FILE) Y X rJ^ W uj c J 0!. W Q O Om 0 LU I Of O Q 0O Z W Q, Q N r Ln U I..L Q 10 O� 00 U o O� L E O O X U - U j c U N -sI '0 3 Q ,0 3 N O` o� C N 0 � 0 C:) a- 10 C7 ICQI IC rl/'7+G' 7/19/22 Revision Date: 9/15/2022 LICENSED ARCHITECT AR986950 KEVIN L. CROOK STATE OFIDAHO Project #: 22068 Sheet Name: Exterior Elevations Sheet #: A4.2 H 3 = i U 01( U U SCALE: 1/4" = 1'-0" Filename: A4.2.tlw9