HomeMy WebLinkAboutA3.1 - Roof Plan V1aWRIDI 9- APPROVED Im osrzsrzz fy0pq;aznas ROOF PLAN ATTIC VENTILATION CALCS A. VENTED ATTICS: PER IRC SEC. R806.2.1 THE MINIMUM NET VENT. AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. EXCEPTION: THE MIN NEF FREE VENT AREA SHALL BE 1 /300 OF THE AREA OF THE VENTED SPACE PROVIDED BOTH OF THE FOLLOWING ARE MET: 1. IN CLIMATE ZONES 14 & 16, A CLASS 1 OR 11 VAPOR RETARDER IS INSTALLED ON THE WARN -IN -WINTER SIDE OF THE CEILING. 2. NOT LESS THAN 40% AND NOT MORE THAN 50% OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NOT MORE THAN 3 FT. BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY. THE BALANCE OF THE REQUIRED VENTILATION SHALL BE LOCATED IN THE BOTTOM ONE-THIRD OF THE ATTIC SPACE. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FT. BELOW THE RIDGE OF HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. SEE ELEVATION SHEETS FOR ATTIC AREA SQ.FT. FLAT TILE ROOFS SHALL BE VENTILATED ACCORDING TO THE FOLLOWING: ATTIC AREA VENT RATIO 1 /300 (S.F.) (FLAT TILE) 0 - 406 (2) VENTS - O'HAGIN STANDARD (2 x 97.50 S.I. / 144 S.I. x 300 S.F.) 407 812 (4)VENTS- O'HAGIN STANDARD (4 x 97.50 S.I. / 144 S.I. x 300 S.F.) 813 1218 (6)VENTS- O'HAGIN STANDARD (6 x 97.50 S.I. / 144 S.I. x 300 S.F.) 1219 - 1625 (8) VENTS - O'HAGIN STANDARD (8 x 97.50 S.I. / 144 S.I. x 300 S.F.) 1626-2031 (10)VENTS- O'HAGIN STANDARD (10 x 97.50 S.I. / 144 S.I. x 300 S.F.) ATTIC AREA VENT RATIO 1/150 (S.F.) (FLAT TILE) 0 - 203 (2) VENTS - O'HAGIN STANDARD (2 x 97.50 S.I. / 144 S.I. x 150 S.F.) 204 - 406 (4) VENTS - O'HAGIN STANDARD (4 x 97.50 S.I. / 144 S.I. x 150 S.F.) 407 - 609 (6) VENTS - O'HAGIN STANDARD (6 x 97.50 S.I. / 144 S.I. x 150 S.F.) NOTE: ALL VENTILATION CALCULATIONS ARE BASED ON VENTS WITH 97.50 SQ. IN. NET FREE VENT AREA AS PROVIDED BY O'HAGIN PRODUCTS ('S" FILE) NO ROOF PENETRATIONS IN SHADED AREA PROVIDE 5/8" TYPE 'X' GYPSUM TO UNDER ( j SIDE OF PLYWOOD ROOF SHEATHING. Ir/ -ALT. PROVIDE FIRE RATED PLYWOOD ROOF SHEATING. - SEE DETAIL SHEET FDA LZ— — — — — — — — — — — U J X rJ ^ `� ' uj uj c J 0!. w Q O Om In Ld _F_ O �I � Z - UOf O Q 0O Z W Q r Ln UN I..L Q ICCI IA nritA' 7/19/22 Revision Date: 9/15/2022 LICENSED ARCHITECT AR986950 KEVIN L. CROOK STATE OFIDAHO Project #: 22068 Sheet Name: Roof Plan Sheet #: A3.1 0 U U SCALE: 1/4" = 1'-0" Filename: A3.l.tlwg