HomeMy WebLinkAboutA2.1 - Utility Plan V1APPROVED uEre E52612z NIE NUMBEP:���a� UP 9U 'A/C'\A I I I I SHEET NOTES A. GENERAL PROVISIONS: IN EVERY KITCHEN, FAMILY ROOM, DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN, SUNROOM, BEDROOM, RECREATION ROOM, OR SIMILAR ROOM, OR AREA OF DWELLING UNITS, RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE GENERAL PROVISIONS SPECIFIED IN THE FOLLOWING ARTICLES. SPACING NEC ARTICLE 210.52(A)(1), WALL SPACE NEC ARTICLE 210.52(A)(2) AS AMENDED & FLOOR RECEPTACLES NEC ARTICLE 210.52(A)(3) AS AMENDED. B. COUNTERTOPS: IN KITCHEN & DINING ROOMS OF DWELLING UNITS, RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC. NO MORE THAN (5) DUPLEX RECEPTACLE OUTLETS SERVING THE REQUIRED COUNTERTOP RECEPTACLES SHALL BE INSTALLED ON ANY SMALL APPLIANCE BRANCH CIRCUIT PER THE NEC. C. PROVIDE 1 FOOT CANDLE ON EVERY STAIR TREAD AND LANDING PER THE IRC. D. THE FOLLOWING FASTENED -IN -PLACE APPLIANCES ARE REQUIRED TO HAVE A SEPARATE MINIMUM 20-AMPERE CIRCUIT: DISHWASHER, TRASH COMPACTOR, MICROWAVE OVEN, AND HYDRO -MASSAGE BATHTUB. THE CLOTHES WASHER CIRCUIT MAY SERVE ONE (1) ADDITIONAL OUTLET IN THE LAUNDRY AREA. (NEC ARTICLE 210.23(E)(3) AS AMENDED) E. IN THE KITCHEN PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREA OF A DWELLING UNIT, THE TWO OR MORE 20-AMPERE SMALL APPLIANCE BRANCH CIRCUITS REQUIRED BY 210.11(C)(1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE OUTLETS COVERED BY 210.52(A), All COUNTERTOP OUTLETS COVERED BY 210.52(C), AND RECEPTACLE OUTLETS FOR REFRIGERATION EQUIPMENT. PER THE NEC. F. ALL 120-VOLT, SINGLE PHASE, 15- AND 20- AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. PER NEC 210.12(B). G. THE MAXIMUM NUMBER OF OUTLETS ON A 20-AMPERE, 125-VOLT CIRCUIT USED EITHER EXCLUSIVELY FOR RECEPTACLES OR EXCLUSIVELY FOR LIGHTING FIXTURES OR FOR ANY COMBINATION OF RECEPTACLES AND LIGHTING FIXTURES SHALL BE 12. (SEE EXCEPTIONS) (NEC ARTICLE 210(E)(2) AS AMENDED) H. OUTLET BOXES OR OUTLET BOX SYSTEMS USED AS THE SOLE SUPPORT OF A CEILING -SUSPENDED (PADDLE) FAN SHALL BE LISTED, SHALL BE MARKED BY THEIR MANUFACTURER AS SUITABLE FOR THIS PURPOSE, AND SHALL NOT SUPPORT CEILINGSUSPENDED(PADDLE) GAN THAT WEIGH MORE THAN 32KG (70 LB). FOR OUTLET BOXES OR OUTLET BOX SYSTEMS DESIGNED TO SUPPORT CEILING -SUSPENDED (PADDLE) FANS THAT WEIGH MORE THAN 16KG (35 LB), THE REQUIRED MARKING SHALL INCLUDE THE MAXIMUM WEIGHT TO BE SUPPORTED PER THE NEC. I. LUMINAIRES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH THE NEC. J. ALL LUMINAIRES (FIXTURES) INSTALLED IN DAMP LOCATIONS SHALL BE MARKED "SUITABLE FOR WET LOCATIONS" OR "SUITABLE FOR DAMP LOCATIONS". PER THE NEC. UTILITY NOTES A. FUEL BURNING EQUIPMENT SHALL BE EQUIPPED WITH AN APPROVED AUTOMATIC MEANS WHICH WILL SHUT OFF FUEL SUPPLY TO EQUIPMENT IN THE EVENT OF IGNITION OR FLAME FAILURE PER THE U.M.C. B. GAS PIPING EXTENDING THROUGH FOUNDATION WALL SHALL BE SLEEVED AND HAVE ITS OPENING SEALED ON OUTSIDE PER THE U.P.C. C. ALL RECEPTACLES THAT SERVE THE COUNTER AREA SHALL BE GFI PROTECTED IN KITCHEN AREA PER THE NEC. D. PROVIDE MIN. TWO (2) 20-AMP SMALL APPLIANCE BRANCH CIRCUITS FOR KITCHEN AND SHALL HAVE NO OTHER OUTLETS PER THE NEC. E. BATHROOM CIRCUITS SHALL HAVE NO OTHER OUTLETS, MINIMUM 20-AMP CIRCUIT PER THE NEC. F. PROVIDE WATER SOFTENER (LOOP ONLY). G. PROVIDE ARC FAULT CIRCUIT PROTECTION AT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS PER THE NEC. UTILITY PLAN - SYMBOLS ELECTRICAL SWITCH 3 ELECTRICAL SWITCH - 3 WAY $ ELECTRICAL SWITCH-4 WAY �J ELECTRICAL JUNCTION BOX SURFACE CEILING MOUNTED LIGHT -OIL FLUORESCENT CEILING -MOUNTED LIGHT 0 RECESSED CAN LIGHT 0W RECESSED CEILING -MOUNTED LIGHT VAPOR PROOF � PENDANT LIGHT FIXTURE YYR WALL -MOUNTED LIGHT �Hc> FLUORESCENT WALL MOUNTED LIGHT CARRIAGE LIGHTS +78" A.F.F. U.N.O. FLUORESCENT FIXTURE - MOUNTED BENEATH UPPER CABINETRY E= ADDRESS LIGHT FIL SURFACE MOUNTED FLUORESCENT FIXTURE THERMOSTAT CONTROL -WALL -MOUNTED G)110V SMOKE DETECTOR TO SOUND ALARM AUDIBLE IN ALL SLEEPING I SD I AREAS BE HARDWIRED WITH BATTERY BACKUP I j OCD CARBON MONOXIDE DETECTOR - (MIN. 3'-0" FROM ANY RETURN AIR GRILL, I BATHROOM DOOR OR CEILING FAN) O COMBINATION CARBON MONOXIDE / SMOKE DETECTOR TO SOUND ALARM SD CD AUDIBLE IN ALL SLEEPING AREAS. HARDWARE WITH BATTERY BACKUP. (MIN. &-0" I FROM ANY RETURN AIR GRILL, BATHROOM DOOR OR CEILING FAN) I I EXHAUST FAN (ENERGY STAR RATED) 50 CFM MIN. - PROVIDE READILY ACCESSIBLE HC HUMIDISTAT CONTROL WITH CAPABLE ADJUSTMENT BETWEEN A RELATIVE j HUMIDITY RANGE OF 50 TO 80 PERCENT - RECESSED CEILING -MOUNTED I I I I I CEILING FAN U J X tJ^ Lu Lu 00 nJ Qo W ocy) O LLJ � OLn 6Q r7 O 0 U O ;N J Z Lu Q r Ln UN I..L n� n 10 O, DD Q LO U o a O� T E o� O O X U ILL. U j 00 U 0 Q 10 3 En O� >0. � O O O_ 10 C7 1 e 1 — Ml +­ //ly/11 Revision Date: 9/15/2022 LICENSED ARCHITECT P R986950. CROOK OFIDAHO Project #: 22068 Sheet Name UTILITY & SOFFIT PLANS H ( 2 � U " J 011 O 1 U 1 UTILITY & SOFFIT PLAN - LEVEL 1 SCALE: 1/4" = 1'-0" UTILITY & SOFFIT PLAN - LEVEL 2 SCALE: 1/4" = 1'-0" A2.1 Filename: A2.1., Plot Dated: SeD