Loading...
Skybreak Monuments - 1.0 - Site & Monument Plans V1APPROVED u FU0 a GENERAL NOTES: ALL CODE STANDARDS AND SPECIFICATIONS REFERRED TO IN THESE NOTES ARE TO BE PART OF THESE NOTES. UNLESS NOTED OTHERWISE, THESE SHALL BE THE LATEST EDITION AND PROCESS. • ALL DETAILS AND NOTES IN OR ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO LIKE SITUATIONS. CONSTRUCTION NOT SPECIFICALLY SHOWN SHALL BE ACCOMPLISHED PER MINIMUM REQUIREMENTS OF THE 2018 IBC. • CONTRACTOR SHALL COMPARE ALL DIMENSIONS AND CONDITIONS ON CONTRACT DOCUMENTS AND AT THE SITE. ANY OMISSION OR CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER. IN CASE OF ANY CONFLICT FOLLOW THE MOST STRICT REQUIREMENTS AS DIRECTED BY THE OWNER. CONTRACTOR SHALL COMPLY WITH ALL THE BEST TRADES OF CONSTRUCTION ON ALL ITEMS THAT ARE TO BE INCLUDED INTO THE STRUCTURE. ORDER OF CONSTRUCTION TO BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL PROVIDE ALL ITEMS NECESSARY FOR THE CHOSEN PROCEDURE. UNTIL ALL PERMANENT MEMBERS, INCLUDING BUT NOT LIMITED TO WALLS, SLABS, FLOORS, AND ROOFS ARE IN PLACE AND ALL CONNECTIONS ARE COMPLETED, STABILITY OF THE STRUCTURE AND ALL PARTS OF IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY. DURING AND AFTER CONSTRUCTION THE CONTRACTOR AND/OR OWNER SHALL KEEP LOADS ON STRUCTURE WITHIN THE LIMITS OF THE DESIGN. OBSERVATION VISITS TO THE SITE SHALL BY OWNER NOT BE CONSIDERED AS AN INSPECTION OF THE STRUCTURE UNTIL COMPLETE. REINFORCED CONCRETE: • ALL CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH EQUAL TO 3500 PSI WITHIN 28 DAYS AFTER PLACING. NORMAL WIGHT AGGREGATES SHALL COMPLY WITH ASTM C-33 AND SHALL PRODUCE CONCRETE WEIGHING WITHIN 145 TO 155 POUNDS PER CUBIC FOOT. WATER USED IN CONCRETE SHALL BE POTABLE. CALCIUM CHLORIDE, ALUMINUM CONDUIT, PRODUCT CONTAINING ALUMINUM OR ANY OTHER MATERIAL HARMFUL TO CONCRETE SHALL NOT BE USED IN COMPOUND. METAL REINFORCEMENT SHALL BE DEFORMED TYPE BARS AND SHALL CONFORM TO ASTM A-615 GRADE 60 WITH MINIMUM YIELD STRENGTH OF 60 KSI. ALL REINFORCEMENT BARS SHALL BE DETAILED, BOLSTERED, AND SUPPORTED IN ACCORDANCE WITH ACI STANDARD 318. SUBMIT SHOP DRAWING FOR REVIEW PRIOR TO FABRICATION. PROVIDE MINIMUM CONCRETE COVER FOR REINFORCEMENT AS FOLLOWS UNLESS NOTED OTHERWISE. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED EARTH = 3" CONCRETE EXPOSED TO EARTH OR WEATHER, #5 BARS AND SMALLER = 1.5" ALL FORMWORK SHALL COMPLY WITH REQUIREMENTS OF ACI STANDARD PUBLICATION NO 347. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN, CARE, DETAILING, PLACEMENT, AND REMOVAL OF ALL FORMWORK AND SHORING. • TEMPERATURE REINFORCEMENT SPLICES IN WALLS, CONTINUOUS FOOTINGS, AND SLABS SHALL LAP 30 BAR DIAMETER. SPLICES SHALL BE STAGGERED 24" MINIMUM. ALL OTHER SPLICES SHALL BE AS SHOWN OR NOTED ON DRAWINGS. ADDITIONAL SPLICES (IF REQUIRED) SHALL COMPLY WITH THE REQUIREMENTS OF THE IBC AND SHALL BE APPROVED BY THE OWNER. ALL HORIZONTAL REINFORCEMENT SHALL HAVE MATCHING DOWELS AT INTERSECTIONS AND AT CORNERS OF THE WALLS. ALL VERTICAL REINFORCEMENT SHALL HAVE MATCHING DOWELS IN FOOTING OR STRUCTURE BELOW. GRADE 16'-0" EARTH WORK: ALLOWABLE SOIL BEARING PRESSURE ASSUMED TO BE 1,500 PSF ALL FOOTINGS SHALL BEAR ON NATIVE SOIL UNLESS DIRECTED BY GEOTECHNICAL ENGINEER. BOTTOM OF FOOTINGS TO BE 24" MINIMUM BELOW FINISH GRADE. DESIGN CRITERIA: GOVERNING CODE: 20181BC GRAVITY LOADS: CONCRETE DEAD LOAD 150 PCF. MASONRY DEAD LOAD 80 PCF. LATERAL LOADS: SOIL ACTIVE PRESSURE 38 PSF./FT. ROOF SNOW LOAD 25 PSF. SEISMIC LOADS: SOIL SITE CLASS D SHORT TERM SPECTRAL RESPONSE 0.31 ONE SEC. SPECTRAL RESPONSE 0.11 SEISMIC USE GROUP I SEISMIC IMPORTANCE FACTOR 1.0 SEISMIC DESIGN CATEGORY C WIND LOADS: EXPOSURE B BASIC WIND SPEED 115 MPH GUST FACTOR, G 0.85 DIRECTIONAL FACTOR, Kd 0.85 IMPORTANCE FACTOR 1.0 BUILDING ANALYSIS: TYPE OF CONSTRUCTION: IV -A OCCUPANCYTYPE: U STRUCTURES SQUARE FEET: 275 SF 6'-0" 6'-0" 11'-6" EQ EQ 42" TALL WALL MOUNT LIGHTS BY DEVELOPER - INSTALL (CENTER OF LIGHT) AT 84" ABOVE TOP OF SLAB, BACK PLATE TO BE DETERMINED (TYP. OF (4)) 5-3/4" CONCRETE CAP WITH 1/4"/FOOT SLOPE TO BACK - SEE PLAN MOON LIGHT ROUGH CUT CULTURED STONE VENEER (TYP.) 6" CONCRETE CURB ROAD WIDTH WATER PROOF OUTLET 24" ABOVE GRADE - LOCATE CENTERED/ BELOW LIGHT 5-3/4" CONCRETE CAP WITH 1 /4"/FOOT SLOPE TO BACK - SEE PLAN MOONLIGHT ROUGH CUT CULTURED STONE VENEER (TYP.) 6" CONCRETE CURB IN -GROUND WELL LIGHTS - VISTA BRAND: MODEL 1182 (TYP. OF (4)) �1[T - 6" CONCRETE CURB L FRONT & REAR ELEVATION T-0" T-0" 0 N 3'- 0" 3' - 0" 1 /4" = 1'-0" ►!A 10'-0" WALK RETAINING WALL 61' - 0" o H BLOCK 1 VERIFY � Z N Q N 'a PLANTER 6•CONCRETE CURB TRAFFIC FLOW (EXIT SUBDIVISION) 1 o - - — - - I z fi' CONCRETE CURB EQ � EQ TRAFFIC FLOW (INTO SUBDIVISION) PLANTER 6' CONCRETE CURB o F z ) - - - - - - - - - - _rY — O J d' in 10'-0" 61'-0" z BLocKz WALK VERIFY `" a RETAINING WALL SITE PLAN N1 if = 20'-0" 5-3/4" CONCRETE CAP WITH 1/4"/FOOT SLOPE TO BACK - SEE PLAN — �r. - - F - h - - MOON LIGHT ROUGH CUT CULTURED STONE - VENEER (TYP.) psi o r C �c -- 6" CONCRETE CURB ROAD WIDTH WATER PROOF OUTLET — 24" ABOVE GRADE - LOCATE CENTERED/ BELOW LIGHT 1'-6"1 6'-0" 1 6'-0" EQ EQ 42" TALL WALL MOUNT — LIGHTS BY DEVELOPER - INSTALL (CENTER OF LIGHT) AT 84" ABOVE TOP OF SLAB, BACK PLATE TO BE DETERMINED (TYP. OF (4)) GRADE SKYBREAK- ENTRY MONUMENTS PROJECTINFO: LOT: BLOCK: SKYBREAK SUBDIVISION X X DRAWN BY: RA PLOT DATE: 9/8/2022 12:58:33 PM MSTR DATE: FOR STRUCUTURAL CALCULATIONS ONLY, SHEET TITLE: ENTRY MONUMENTS & ELECTRICAL PLANS ELECTRICAL PLAN 1/4" = 1'-0" SHEET NUMBER: 1.0