HomeMy WebLinkAboutCC - Staff Report 9-27 STAFF REPORT E COMMUNITY
N --
COMMUNITY DEVELOPMENT DEPARTMENT .►A H O
HEARING 9/27/2022
Leg R- �
DATE: end 4� 0
Project Location
TO: Mayor&City Council
R-1
FROM: Sonya Allen,Associate Planner R- I-L
208-884-5533 C-N
R-15
SUBJECT: FP-2022-0024
TM Creek No. 6 R'1 C-C C_G TN-R
R- R- RUT'
LOCATION: Northeast corner of S.Wayfinder Ave. RUT C-G TN-R
and W. Cobalt Dr., in the NW 1/4 of
Section 14,T.3N.,R.1W. (Parcel TN-C C-G TN-C R-4
#S1214212802) C-C R-8
RUT
C-C H-E R1
I. PROJECT DESCRIPTION
Final plat consisting of seven(7)buildable lots on 13.29 acres of land in the C-G zoning district for
the sixth phase of TM Creek Subdivision.
II. APPLICANT INFORMATION
A. Applicant/Representative:
Josh Beach,Brighton Development, Inc—2929 W.Navigator Dr., Ste. 400,Meridian,ID 83642
B. Owner:
Robert Phillips,DWT Investments,LLC—2929 W.Navigator Dr., Ste. 400,Meridian, ID 83642
III. STAFF ANALYSIS
Staff has reviewed the proposed final plat for substantial compliance with the approved preliminary
plats for TM Creek(PP-13-030) and TM Center(H-2020-0074)and associated conditions of
approval as required by UDC 11-6B-3C.2. There are approximately 5 fewer buildable lots and the
same amount of common open space as shown on the approved preliminary plats. Therefore, Staff
finds the proposed final plat is in substantial compliance with the approved preliminary plats as
required.
Page 14
IV. DECISION
A. Staff-
Staff recommends approval of the proposed final plat with the conditions of approval in Section
VI of this report.
V. EXHIBITS
A. Preliminary Plats(TM Creek PP-13-030 &TM Center H-2020-0074)
oval nEx
o � ,su_w aau nm s,m sm ururx
rva5 m e \ V-r' �. I�FRNVpJN ND
u ,vim rmm om,� .n ,ss ,csss� �J 6ea
114Q — \I
asu55 '�•• ���-�e �nll, , --
��sT�x.nl�xT-of-wa. -- xx„Ix ¢ s,; � 4A
Y
a .�.,I.
e,
ICI g/ ssasr r i$ la e,sos �\ss �\ v
]sF
's '.�- TENMILEORAI-
ilgel �.m BLOCK IIla
---�',q'
12
ffi- ro a .I c
TEry MRE CREoc DRM - - - �
BLOCK 3
�T� �+seej4 pyT
r+arw. r�,rwwMw
® NOTAPART O}(9
F NOT PART
5 =1
yyF
yp UNPIA= Fvr�xE xo�%I% T
d �
KELLER TM CREEK PRELIMINARY PLAT ' 9047-6
am zQ�D °aa°`I't— BRIGHTON
CORPORATION SITE LAYOUT �2 OF 3
Page 15
TM CENTER SUBDIVISION PRELIMINARY PLAT VICNI—AP:L=t'°°°
TJA PARCEL OF LAND BEING A PC RTION OF THE NORTH WEST 1/4 AND A PORTION OF THE W.F.—IN R0.�
WEST 1/2 OF THE NORTHEAST 1/4 OF SECTION 14,TOWNSHIP 3 NORTH,RANGE 1 WEST,
B015E MERIDIAN,CITY OF MERIDIAN,ADA COUNTY,IDAHO,2020
vn.i ri�w.aia�n
C �-�LWLllllll
i
I vmvu.u, ® i
I
�a o ® �� 7.
0 0
RPEL141INMYRFAT DATA LEGEND
i
TM CEWFER51JBDIV1510H i
MERIDIAN.IDAHO
imm
onrmwmr T -
Rvt.o
Page 16
B. Final Plat(date: 7/19/2022)
60DKPAGE
"'p w.Franklin Rtl 'fin 1''m°'w _
m u «. �i E�ss Nr AuwNc �r R>rlw Plat of
se�BB•RB� esa.cs
15 ,4 �� � - ---------- --- --- --- -VV TM Creek Subdivision No.6
md3E'31 Y lots 14,Block 3 of TM 0-1k Subdivision No,4 End
c YEB'orr, t1.w[TIE) d MrWn OI me Northeast V4 of the klo wo11/4 OI
53.19' Smlion lE,T—hlB3 NNrdl,Aarp 1 Vi 9.M,
900'Ea'Sr"w City of Meridian,Ada Cmrty.ldah0
5 __ 1e.Ep' I1nWNlbd 2022
ElYpB'98"E 20.00' SBB'097.1
"E E]].22'
VOW
1 AnLV VSf
Q 7 g
EBO
ar�sd...ea
SHEET INDEX
[ I�cTE elaorncx _ ___
-____ --- _______
aw ^
• pg F pQ$
J- -- - - SMF£r 1-SJIUMSAN Plni
�
J L_l SRFET 1-LEATnG.TE OF OrmFRG uG igtt5 i�
rq,W' 190.00'
9� -� -- _ �'1AY1 EBE.Tn' _-________---y r I v¢rs-[fmFlai¢iun wmmass
y I I I I LEGEND
44 I � iWNe iWIYNW GR.AS NOTED
X�•`� � /� h I B F➢UNO BRAR9 CND M TnTEO
� ,� ter/ €� � � i i i p w 9r�rcR wRREa roEs,xr
Nevw'1a1v / X � 4 I I I I uxuss
II / Epu
i .rvy
i .'9.15' �" / \ T� 3 SET 5/5-mGx nEB!R wttn PE nw GP
/ O--- �p39 RWp lnlNl I.vY,RET�W9Wr]
-- OF "P181b5B'
nMIND L1UGS RUG[IMR wGILTL is4M
I- e"Ga ixG1BuDR j EO9Er l:lDlj- ol_- N�XE i i M1 f m.� S CN.CNATEA vOiNr
� ! j I �a �E LOT NuueER
I+I
SueNNGIEn BdINMR1'uK
I i I I I InT urE
1 I I I I
I L___, DIN I,NE
CENRTtI1NE
! rLu.CNrt EPJNOY{Y 11Nf
__ ----- EASEMENT NNE
I I
I �ya3 L-J LIIMTMIE
EancNr EEx mBv' m.,e' arxsm•9BBsr,Bw eay
I IRLrEeT�xoty minis
uM�R'non.,w/os
I reare.s 9xow.
JII � S�'16'EOY1 .19..3' - Wv,.S'�A^E 9nas'arlT n
r]650' 9Yai'seroe'erM'eo
I bt6,Bbck9 I+
TM GeeI S,ILbiflen rbl RN,-r5]]B] _--_____` A
�.•EM V IdOw 6 d i"' nv Di KB.M1,. TEn Mile OrEIn Oi NESIZ,n-w
I PEn rpnnlyxT�ry]W,-,SE%5 E a Y16R mimic ee.93' Lars
E�`FR
LN INM
---__ jff--
C^
- ---- -- ss OBI "x E 7m, 12459
L011,Blak 3 39B']9'20'fB
TM&Sk 9.EC •�Trt p�0o
SUNdIMsion HO.S NnowHM �Nl gkl�
5LPi NARRATNE 1,l7' Z E N 6 i N E E e I N G
M R.Wff p<n•S``-9Rrtf n TO ONM.aC(M lwb flan, REEER[N�F
Nu�w.n[ R.ce i9 Bean T,[a[TRarmrt or PUTS R, PIAT Or 9u—1 9pBpK>D A BOOK 1 N K
1 �Utvi PK25 11A1t19A.i,nELORCG Of Aa EOUII�'.�WnOi Ok1'ELOR com
in ANTo`ee:i� m�oi+"".KE �. s BRA_ BRIGHTDN CORPORATION
xxBB> TUT awrB> sn/n�!sEnvw scw�E� wcn vrcM mumr.ILwq. MERID",IG
Page 17
C. Landscape Plan(date: 6/17/2022)
PWIESOILDIIIE �scor
-------------
--------------------------------------------------
°.
.a�rseemaa mum �.d..Y.�,...._. •oc �.' � �——.—.�—
+T---
_—_ n��i
a nc wmu �'g.up m a s
- w,.c 1 flEq�WI1STPEE PLdMIrIG RTAIL� I,� �� g
ell 6
— ;
_ ... a -- - ---- ------ ---- ----- ---- -- ------------------ —---
-t7
o ..... .... -a
.
-- ----------- ------------- ---
`
P`
9DFFER PLANTING DETAIL,.. LANDSCAPE PLAN
u.o
Page 18
VI. CITY/AGENCY COMMENTS & CONDITIONS
A. Planning Division
Site Specific Conditions:
1. Applicant shall comply with all previous conditions of approval associated with this
development [TM Creek:AZ-13-015(DA Inst. #114045759; 1st Addendum Inst. 2016-
073497; and 2nd Addendum Inst. #2017-113747 and preliminary plat(PP-13-030); Ten Mile
Center(H-2020-0074),DA Inst. 2021-089157].
2. The applicant shall obtain the City Engineer's signature on the final plat within two(2)years
of the City Engineer's signature on the previous phase final plat(TM Creek No. 5) in accord
with UDC 11-613-7 in order for the preliminary plats [TM Creek(PP-13-030)and TM Center
(H-2020-0074)] to remain valid; or, a time extension may be requested.
3. Prior to submittal for the City Engineer's signature,have the Certificate of Owners and the
accompanying acknowledgement signed and notarized.
4. The final plat shown in Section V.B prepared by KM Engineering, stamped on 7/19/2022 by
Aaron L. Ballard, shall be revised as follows:
a. Include the recorded instrument number of the City of Meridian water and sewer easement
graphically depicted on the face of the plat.
b. Include the recorded instrument number of the City of Meridian utility easement
graphically depicted on the face of the plat.
c. Note#4: Strike all of the info pertaining to development agreements(DA's)for TM Creek.
These agreements were all replaced with one new DA for the overall development,
recorded as Inst. #2021-089157.
d. Note #7: Do the Master CC&R's include the land approved with the preliminary plat for
TM Center?Make any changes necessary to this note to be accurate.
e. Note#19: ". . . approved with PP-13-030 and H-2020-0074 by the City of Meridian. . .".
An electronic copy of the revised plat shall be submitted to the Planning Division prior to
signature on the final plat by the City Engineer.
5. The landscape plan shown in Section V.C, prepared by KM Engineering, dated 6/17/22, is
approved as submitted.
6. Prior to signature on the final plat by the City Engineer, submit an application for and obtain
final approval of the proposed private street within the development. Private streets shall
comply with the standards listed in UDC 11-3F-4.
7. All future development shall comply with the minimum dimensional standards listed in UDC
Table 11-2B-3 for the C-G zoning district and UDC 11-4-3-27B.1.
8. The final plat shall be recorded prior to issuance of any Certificates of Occupancy for the site
per requirement of the Development Agreement(provision#5.1(23).
9. Staff s failure to cite specific ordinance provisions or conditions from the preliminary plats
and/or development agreements does not relieve the Applicant of responsibility for compliance.
Page 19
B. Public Works
Site Specific Conditions:
1. Center water main in 20'easement.
2. Provide a 5'easement, in all directions,that is clear of all permanent structures(including
carports)around the fire hydrants.
3. Provide a 20'easement up to the water meters.
4. Provide easement for all utilities even those in private road if not already provided.
5. Plans do not show easement going to the property to the east. Add this easement to the plans.
6. For Line C the City does not want that steep of a pipe discharging to manhole SS EXIST.
Either decrease the slope to 8%for the section that ties into the manhole(still need to meet
building codes) or have the service tie in downstream of manhole.
7. Sewer easement widths varies depending on sewer depth. Sewer 0-15 ft deep require a 20 ft
easement, 16-20 ft a 30 ft easement, and 21-30 ft a 40 ft easement. Adjust easements
accordingly.
8. Service lines to buildings should be 6"not 8".
9. There is an existing service line 85ft south of SS EXIST.Unused stubs must be abandoned
per City requirements.
10. Ensure no sewer services pass through infiltration trenches.
11. A future install agreement for seven(7) streetlights will be required for the development of
this property.
General Conditions:
12. Sanitary sewer service to this development is available via extension of existing mains adjacent
to the development. The applicant shall install mains to and through this subdivision; applicant
shall coordinate main size and routing with the Public Works Department,and execute standard
forms of easements for any mains that are required to provide service. Minimum cover over
sewer mains is three feet, if cover from top of pipe to sub-grade is less than three feet than
alternate materials shall be used in conformance of City of Meridian Public Works Departments
Standard Specifications.
13. Water service to this site is available via extension of existing mains adjacent to the
development. The applicant shall be responsible to install water mains to and through this
development, coordinate main size and routing with Public Works.
Page 20
14. All improvements related to public life,safety and health shall be completed prior to occupancy
of the structures. Where approved by the City Engineer, an owner may post a performance
surety for such improvements in order to obtain City Engineer signature on the final plat as set
forth in UDC 11-5C-3B.
15. Upon installation of the landscaping and prior to inspection by Planning Department staff,the
applicant shall provide a written certificate of completion as set forth in UDC 11-313-14A.
16. A letter of credit or cash surety in the amount of 110% will be required for all incomplete
fencing, landscaping, amenities,pressurized irrigation,prior to signature on the final plat.
17. The City of Meridian requires that the owner post with the City a performance surety in the
amount of 125% of the total construction cost for all incomplete sewer, water infrastructure
prior to final plat signature. This surety will be verified by a line item cost estimate provided
by the owner to the City. The applicant shall be required to enter into a Development Surety
Agreement with the City of Meridian. The surety can be posted in the form of an irrevocable
letter of credit, cash deposit or bond. Applicant must file an application for surety, which can
be found on the Community Development Department website. Please contact Land
Development Service for more information at 887-2211.
18. The City of Meridian requires that the owner post to the City a warranty surety in the amount
of 20% of the total construction cost for all completed sewer, and water infrastructure for a
duration of two years. This surety amount will be verified by a line item final cost invoicing
provided by the owner to the City.The surety can be posted in the form of an irrevocable letter
of credit, cash deposit or bond. Applicant must file an application for surety, which can be
found on the Community Development Department website. Please contact Land
Development Service for more information at 887-2211.
19. In the event that an applicant and/or owner cannot complete non-life,non-safety and non-health
improvements, prior to City Engineer signature on the final plat and/or prior to occupancy, a
surety agreement may be approved as set forth in UDC 11-5C-3C.
20. Applicant shall be required to pay Public Works development plan review, and construction
inspection fees, as determined during the plan review process, prior to the issuance of a plan
approval letter.
21. It shall be the responsibility of the applicant to ensure that all development features comply
with the Americans with Disabilities Act and the Fair Housing Act.
22. Applicant shall be responsible for application and compliance with any Section 404 Permitting
that may be required by the Army Corps of Engineers.
23. Developer shall coordinate mailbox locations with the Meridian Post Office.
24. All grading of the site shall be performed in conformance with MCC 11-1-4B.
25. Compaction test results shall be submitted to the Meridian Building Department for all building
pads receiving engineered backfill,where footing would sit atop fill material.
26. The engineer shall be required to certify that the street centerline elevations are set a minimum
of 3-feet above the highest established peak groundwater elevation. This is to ensure that the
bottom elevation of the crawl spaces of homes is at least 1-foot above.
Page 21
27. The applicants design engineer shall be responsible for inspection of all irrigation and/or
drainage facility within this project that do not fall under the jurisdiction of an irrigation district
or ACHD. The design engineer shall provide certification that the facilities have been installed
in accordance with the approved design plans. This certification will be required before a
certificate of occupancy is issued for any structures within the project.
28. At the completion of the project, the applicant shall be responsible to submit record drawings
per the City of Meridian AutoCAD standards. These record drawings must be received and
approved prior to the issuance of a certification of occupancy for any structures within the
project.
29. Street light plan requirements are listed in section 6-7 of the Improvement Standards for Street
Lighting (http://www.meridiancity.org/public_works.aspx?id=272). All street lights shall be
installed at developer's expense. Final design shall be submitted as part of the development
plan set for approval, which must include the location of any existing street lights. The
contractor's work and materials shall conform to the ISPWC and the City of Meridian
Supplemental Specifications to the ISPWC. Contact the City of Meridian Transportation and
Utility Coordinator at 898-5500 for information on the locations of existing street lighting.
30. The applicant shall provide easement(s)for all public water/sewer mains outside of public right
of way (include all water services and hydrants). The easement widths shall be 20-feet wide
for a single utility, or 30-feet wide for two. The easements shall not be dedicated via the plat,
but rather dedicated outside the plat process using the City of Meridian's standard forms. The
easement shall be graphically depicted on the plat for reference purposes. Submit an executed
easement(on the form available from Public Works), a legal description prepared by an Idaho
Licensed Professional Land Surveyor, which must include the area of the easement (marked
EXHIBIT A) and an 81/2" x 11" map with bearings and distances (marked EXHIBIT B) for
review. Both exhibits must be sealed, signed and dated by a Professional Land Surveyor. DO
NOT RECORD. Add a note to the plat referencing this document. All easements must be
submitted,reviewed, and approved prior to signature of the final plat by the City Engineer.
31. Applicant shall be responsible for application and compliance with and NPDES permitting that
may be required by the Environmental Protection Agency.
32. Any existing domestic well system within this project shall be removed from domestic service
per City Ordinance Section 9-1-4 and 9 4 8 contact the City of Meridian Water Department at
(208)888-5242 for inspections of disconnection of services. Wells may be used for non-
domestic purposes such as landscape irrigation if approved by Idaho Department of Water
Resources.
33. Any existing septic systems within this project shall be removed from service per City
Ordinance Section 9-1-4 and 9 4 8. Contact the Central District Health Department for
abandonment procedures and inspections.
34. The City of Meridian requires that pressurized irrigation systems be supplied by a year-round
source of water(MCC 9-1-28.C.1).The applicant should be required to use any existing surface
or well water for the primary source. If a surface or well source is not available, a single-point
connection to the culinary water system shall be required. If a single-point connection is
utilized,the developer will be responsible for the payment of assessments for the common areas
prior to development plan approval.
35. All irrigation ditches, canals, laterals, or drains, exclusive of natural waterways, intersecting,
crossing or laying adjacent and contiguous to the area being subdivided shall be addressed per
UDC 11-3A-6. In performing such work,the applicant shall comply with Idaho Code 42-1207
and any other applicable law or regulation.
Page 22