Loading...
HomeMy WebLinkAboutTrash Enclosure 2 V1APPROVED )r :: 09/15,22 TRASH ENCLOSURE BOLLARD 111 = 1'-0.1 6" STEEL PIPE, FILL WITH CONCRETE EXPANSION JOINT (SEAL) PAVING OR CONCRETE SLAB CONCRETE FOOTING, SEE STRUCTURAL GATE TO SWING OPEN MIN. 115° , MAX. 120° CORRUGATED METAL PANEL SET IN STEEL CHANNEL FRAME WEEP HOLE PROVIDE HOLES A CONCRETE FOR BOT FULLY OPEN ANI CLOSED POSITION SECTION AT CANE BOLT 1 1/2" = 1'-0" 8" CMU WALL, GROUT 8" CMU WALL SOLID. REINFORCE AND TIE INTO FOOTING/SLAB PER STRUCTURAL ELASTOMERIC SEALANT 11/2"ANGLE WELDED TO STEEL FRAME Il 6 WHEELSTOP CURB BAR CANE BOLT 6" GALVANIZED STEEL TUBE POST SET IN CONCRETE 6" SLAB ON GRADE, FOOTING, SEE STRUCTURAL. PAINT TO MATCH DOORS SEE STRUCTURAL FINISH GRADE CORRUGATE METAL PANEL. FINISH TO MATCH BUILDING CANOPY U) a — — = O z II I PROVIDE WEEP HOLES IN BETWEEN Q i:. < a I CORRUGATED METAL CHANNELS o III IIII I , a THICKENED EDGE OF SLAB °- P. CONCRETE FOOTING, SEE STRUCTURAL DRAWINGS v O w STEEL CHANNEL FRAME, MITER AND WELD CORNERS w \ a > GALVANIZED HEAVY DUTY GATE HINGE GATE IN OPEN SWIGN POSITION (120° MIN, 125° MAX) GATE HINGE DETAIL 3" = 1'-01. TYPICAL CMU WALL FOOTING 1.1 = 1'-01. no TEN MILE RETAIL, MERIDIAN, IDAHO V v 10 MILE ROAD - POD 4, TRASH ENCLOSURE DETAILS THE RICHARDSON DESIGN PARTNERSHIP TEL: 801.355.6868 04.08.2022 WWW,TRDP.COM