Loading...
HomeMy WebLinkAboutRevised Landscape Plan V1DWRIDIA y- APPROVED 0911X22 LANDSCAPE SITE PLAN 0 80 160 240 Plan Scale: 1" = 80' CONTACT INFORMATION OWNER BRIGHTON DEVELOPMENT INC. 2929 W. NAVIGATOR DR., SUITE 400 MERIDIAN, IDAHO 83642 PHONE: (208) 378-4000 CONTACT: JON WARDLE EMAIL: jwardle®brightoncorp.com LANDSCAPE CONSULTANT KM ENGINEERING, LLP 5725 NORTH DISCOVERY WAY BOISE, IDAHO 83713 PHONE: (208) 639-6939 FAX: (208) 639-6930 CONTACT: ALYSSA YENSEN, PLA EMAIL: ayensenOkmengllp.com 14� GENERAL LANDSCAPE NOTES 1. VERIFICATION OF TOTAL LANDSCAPE MATERIAL QUANTITIES AS SHOWN ON THIS LANDSCAPE PLAN AND IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR. IF QUANTITIES LISTED DO NOT CORRELATE WITH WHAT IS SHOWN ON THE PLAN, THE QUANTITIES SHOWN ON THE PLAN SHALL GOVERN. THIS INCLUDES, BUT IS NOT LIMITED TO TREE, SHRUB, ROCK, TOPSOIL, MULCH, SEED OR SOD, EDGING, AND DRIP LINE QUANTITIES. 2. IMMEDIATELY AFTER AWARD OF CONTRACT, NOTIFY THE LANDSCAPE ARCHITECT OF AVAILABLY OF SPECIFIED PLANT MATERIAL FROM COMMERCIAL NURSERIES. IF A SPECIFIED PLANT IS NOT AVAILABLE, THE LANDSCAPE ARCHITECT WILL PROVIDE ALTERNATE PLANT MATERIAL SELECTIONS. SUCH CHANGES SHALL NOT ALTER THE ORIGINAL BID PRICE UNLESS A CREDIT IS DUE TO THE OWNER. 3. CONTRACTOR SHALL LOCATE AND IDENTIFY EXISTING UNDERGROUND AND OVERHEAD UTILITIES WITHIN CONTRACT WORK AREAS PRIOR TO CONSTRUCTION. CONTACT DIG LINE, INC. 0 1.800.342.1885. PROVIDE ADEQUATE MEANS OF PROTECTION OF UTILITIES AND SERVICES DESIGNATED TO REMAIN. REPAIR UTILITIES DAMAGED DURING SITE WORK OPERATIONS AT CONTRACTOR'S EXPENSE. 4. PROVIDE REQUIRED SOIL EROSION CONTROL MEASURES THROUGHOUT THE DURATION OF THE CONTRACT PERIOD. SHOULD THERE BE EXISTING SOIL EROSION CONDITIONS THAT REQUIRE MITIGATION, NOTIFY THE RESPONSIBLE PERSON IMMEDIATELY. FAILURE TO NOTIFY THE RESPONSIBLE PERSON IMPLIES ACCEPTANCE OF THE SITE IN ITS EXISTING CONDITION. 5. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING ALL PLANTED AREAS. ALL DELETERIOUS MATERIAL SUCH AS ROCK, TRASH, CONSTRUCTION DEBRIS, AGGREGATE BASE MATERIAL, ASPHALT, ETC.., SHALL BE REMOVED PRIOR TO ANY FILL OPERATIONS. FINISH GRADES TO BE SMOOTH AND EVEN. GRADIENTS TO REMOVE LOW AND HIGH POINTS AND TO PROVIDE POSITIVE DRAINAGE. 6. FILL ALL PLANTING AREAS WITH CLEAN EARTHEN FILL, AS PER SPECIFICATIONS. SOIL SHALL BE FREE OF HEAVY, STIFF CLAY AND ANY DELETERIOUS MATERIAL OVER ONE INCH IN SIZE. REUSE EXISTING SURFACE TOPSOIL IF AVAILABLE. 7. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS, OR OTHER FOREIGN MATERIALS AND A PH OF 5.5 TO 7.0. IF ON -SITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: PROVIDE APPROVED IMPORTED TOPSOIL OR, AMEND THE ON -SITE TOPSOIL. 8. TOPSOIL DEPTHS SHALL BE AS FOLLOWS (WHERE APPLICABLE): LAWN AREAS-6" MIN.; PLANTER BEDS - 12" MIN.; CURB ISLANDS - 18" MIN.ALL PLANTING BEDS SHALL BE TREATED WITH A PRE -EMERGENT HERBICIDE. 9. FINISH GRADES FOR LANDSCAPE AREAS TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN. SLOPES FOR TURF AREAS SHALL NOT EXCEED 3:1. 10. PRE -EMERGENT HERBICIDE SHALL BE APPLIED PER MANUFACTURER'S RECOMMENDATIONS AND SHALL OCCUR AFTER TOPSOIL PLACEMENT AND PRIOR TO INSTALLATION OF PLANT MATERIALS AND MULCH. 11. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN HEALTHY GROWING CONDITION. 12. ALL WRAPPING MATERIAL SHALL BE CUT AND REMOVED FROM AROUND THE UPPER PORTION OF THE ROOT BALL. METAL BASKET WIRES AND BURLAP SHALL BE PULLED BACK AND TUCKED UNDER THE EDGES OF THE SAUCER RINGS ON ALL TREES AND LARGE SHRUBS. ALL SYNTHETIC BURLAP SHALL BE REMOVED FROM ROOT BALLS PRIOR TO BACKFILLING. 13. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN HEALTHY CONDITION IMMEDIATELY WITH COMPARABLE SIZE AND SPECIES AT NO COST TO THE OWNER. 14. FERTILIZE ALL TREES AND SHRUBS WITH AGRIFORM PLANTING TABLETS. QUANTITY PER MANUFACTURERS RECOMMENDATIONS. 15. CONTRACTOR'S MAINTENANCE SHALL INCLUDE: • PRUNING, CULTIVATING, WEEDING, WATERING, AND APPLICATION OF APPROPRIATE INSECTICIDES AND FUNGICIDES NECESSARY TO MAINTAIN PLANTS FREE OF INSECTS AND DISEASE UNTIL FINAL ACCEPTANCE BY OWNER. • RE -SET SETTLED PLANTS TO A PROPER GRADE AND POSITION. • RESTORE PLANTING SAUCER AND ADJACENT MATERIAL AND REMOVE AND REPLACE DEAD MATERIAL. • TIGHTEN AND REPAIR GUY WIRES AND STAKES AS REQUIRED ONLY IF ORIGINALLY NEEDED. • CORRECT DEFECTIVE WORK AS SOON AS POSSIBLE AFTER DEFICIENCIES BECOMES APPARENT AND WEATHER AND SEASON PERMIT. ACHD LANDSCAPE NOTES 1. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR ZONE OF ALL ACHD STORM DRAIN PIPE, STRUCTURES, OR FACILITIES. 2. SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. NOTE: CALCULATIONS SHOWN BELOW ARE TO DETERMINE THE REQUIRED NUMBER OF OPEN SPACE TREES PER CITY OF MERIDIAN UDC AND ARE NOT OPEN SPACE CALCULATIONS. REFER TO THE OPEN SPACE EXHIBIT FOR OFFICIAL QUALIFIED OPEN SPACE CALCULATIONS. STREET TREE CALCULATIONS (1TREE/35 LF) STREET NAME MIN. BUFFER WIDTH LF CALC REQ PRVD S.APEX AVE. 20' 1073 1073 LF/35 31.00 32.00 S. HOPE AVE. 13.5' 1073 1073 LF/35 31.00 32.00 S. ASPIRATION AVE. 15' 1070 1070 LF/35 31.00 32.00 E. CRESCENDO ST. 13.5' 1253 EXCLUDES GAS EASEMENT 1253 LF/35 36.00 36.00 TOTAL STREET TREES 129.00 132.00 MITIGATION REQUIREMENTS THERE ARE NO HEALTHY TREES > 4" CAL. PROPOSED FOR REMOVAL TOTAL TREES REQUIRED/PROVIDED 129.0 132.0 GENERAL IRRIGATION NOTES 1. NO GUARANTEE IS MADE THAT ALL EXISTING UNDERGROUND UTILITIES ARE SHOWN, OR SHOWN CORRECTLY. CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF ANY DEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING UTILITIES SHALL BE CONTRACTOR'S RESPONSIBILITY. 2. THE CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL A COMPLETE IRRIGATION SYSTEM WHICH PROVIDES ADEQUATE WATER COVERAGE TO ALL LAWN AND PLANTING AREAS. THE WORK SHALL CONSIST OF PROVIDING AND INSTALLING ALL MATERIALS NECESSARY FOR A COMPLETE SYSTEM INCLUDING POINT OF CONNECTION, PIPE, VALVES, FITTINGS, HEADS, AUTOMATIC CONTROLS, AND ALL ASSOCIATED LABOR. 3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FOR THIS WORK 4. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS. 5. INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWS AND ORDINANCES. 6. POINT OF CONNECTION: COMPLY WITH REQUIREMENTS OF UTILITY SUPPLYING WATER FOR PREVENTION OF BACKFLOW AND BACK-SIPHONAGE 7. COVERAGE; THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE ONE HUNDRED PERCENT (100%) COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING AS APPROPRIATE. B. MATCHED PRECIPITATION RATES: SPRINKLER HEADS SHALL HAVE MATCHED PRECIPITATION RATES WITHIN EACH CONTROL VALVE. 9. IRRIGATION DISTRICTS: SPRINKLER HEADS IRRIGATING LAWN OR OTHER HIGH WATER DEMAND AREAS SHALL BE CIRCUITED SO THAT THEY ARE ON SEPARATE ZONES FROM THOSE IRRIGATING TREES, SHRUBS, OR OTHER REDUCED WATER DEMAND AREAS. 10. OVERSPRAY: SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES SUCH AS STREETS, SIDEWALKS, DRIVEWAYS, AND PARKING AREAS. 11. PRIOR TO COMMENCING WORK, CONTRACTOR TO CONFIRM PSI IS ADEQUATE TO FURNISH AND INSTALL A COMPLETE IRRIGATION SYSTEM WHICH PROVIDES ADEQUATE WATER COVERAGE TO ALL LAWN AND PLANTING AREAS. SHOULD THE PSI BE LESS THAN ADEQUATE, NOTIFY THE ARCHITECT IMMEDIATELY. IN THE EVENT THAT THE ARCHITECT IS NOT NOTIFIED PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY NECESSARY REVISIONS. 12. WHERE APPLICABLE, LABEL ALL IRRIGATION RISERS, FAUCETS, VALVE BOXES, AND VAULTS WITH DURABLE TAGS CARRYING THE WARNING "DANGER -UNSAFE WATER OR NON -POTABLE WATER." 13.INSTALL ALL PIPING AND VALVES IN PLANTING AREAS WHERE POSSIBLE, AND LOCATE ELECTRIC CONTROL AND QUICK COUPLING VALVES IN GROUND COVER/SHRUB AREAS, 6" TO 12" AWAY FROM EDGE OF PAVEMENT FOR EASE OF ACCESS. 14. PROVIDE UNDERGROUND IRRIGATION SYSTEM AS A COMPLETE UNIT PRODUCED BY A SINGLE ACCEPTABLE MANUFACTURER, INCLUDING HEADS, VALVES, CONTROLS, AND ACCESSORIES. 15. A MIN. OF 4" POP -UPS ARE TO BE USED IN ALL LAWN AREAS. DRIP IRRIGATION TO BE USED IN ALL PLANTER BEDS. 16. THE IRRIGATION CONTRACTOR IS RESPONSIBLE TO SIZE CIRCUIT PIPING. WATER VELOCITY IN ALL PIPES SHALL NOT EXCEED FIVE FEET PER SECOND. MINIMUM PIPE SIZE TO BE 1". 17. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SLEEVES UNDER ALL ROADWAY, PARKING, AND WALKWAY SURFACES. EXTEND 6" MINIMUM BEYOND SURFACE EDGE. IDENTIFY ENDPOINTS OF SLEEVING. 18. ALL IRRIGATION HEADS LOCATED ADJACENT TO ROAD SURFACES NOT PROTECTED BY A VERTICAL CONCRETE CURB SHALL BE PLACED 18" FROM THE EDGE OF THE ROAD SURFACE. 19. WHERE APPLICABLE, CONTRACTOR IS RESPONSIBLE TO PROVIDE 120 VOLT POWER AND ALL REQUIRED CIRCUITS FROM THE ELECTRICAL PANEL TO THE IRRIGATION CONTROLLER. SIZE WIRE AND CONDUIT AS REQUIRED. 20. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW CONSTRUCTION, INCLUDING ADJACENT PROPERTIES. REPAIR INCLUDES BUT IS NOT LIMITED TO PIPING, VALVES, HEADS, DRIP COMPONENTS, CONTROL WIRES AND EQUIPMENT, AND SLEEVES. IF APPLICABLE, IRRIGATION CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT. 21. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN OPERATION OF THE EXISTING SYSTEM DURING THE COARSE OF CONSTRUCTION. 22. LANDSCAPE ARCHITECT IS NOT RESPONSIBLE FOR DISCREPANCIES BETWEEN DESIGN DRAWINGS AND ACTUAL SITE CHARACTERISTICS. CONTRACTOR SHALL FIELD VERIFY ALL INFORMATION PROVIDED ON DRAWINGS. CONTRACTOR SHALL STOP CONSTRUCTION AND CONTACT THE OWNER IMMEDIATELY FOR FURTHER DIRECTION IF DISCREPANCIES OCCUR. 23. UPON COMPLETION, AND PRIOR TO FINAL PAYMENT, THE IRRIGATION CONTRACTOR SHALL PROVIDE A NEAT AND LEGIBLE AS -CONSTRUCTED IRRIGATION PLAN, AN OPERATION AND MAINTENANCE MANUAL, AND UP TO (8) HOURS OF ORIENTATION AND/OR TRAINING FOR THE OWNERS MAINTENANCE AND OPERATIONS STAFF. 24. THE ENTIRE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF IT'S ACCEPTANCE. REPAIR OR REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THAT YEAR SHALL BE COMPLETED PROMPTLY BY THE IRRIGATION CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 25. CONTRACTOR SHALL PROVIDE, AT NO ADDITIONAL COST TO THE OWNER, SPRING START UP AND WINTERIZATION DURING THE GUARANTEE PERIOD. PLANT SCHEDULE SEE 11.1 FOR FULL PLANT SCHEDULE TREES QTY BOTANICAL/COMMON NAME SIZE 0 55 ACER TRUNCATUM'PACIFIC SUNSET'TM 2" CAL. B&B PACIFIC SUNSET MAPLE 0 40 CARPINUS BETULUS 2" CAL. B&B EUROPEAN HORNBEAM C) 20 G LEDITSIA TRIACANTHOS'IMPERIAL' 2" CAL. B&B IMPERIAL HONEYLOCUST 17 PYRUS CALLERYANA'REDSPIRE' 2" CAL. B&B REDSPIRE CALLERY PEAR GROUND COVERS QTY BOTANICAL/COMMON NAME CONT 43,781 SF TURF SOD RHIZOMATOUS SOD RHIZOMATOUS TALL FESCUE OTHER QTY BOTANICAL/COMMON NAME CONT ■ 7,538 SF SHRUBS AND PERENNIALS, OR GRASSES NA .a' �EOFID •'�. Q. . 'SSA Ygy� • 1.A-165.'7 • ��� ••�•7 /28/22 ••' C 4ASCA4� •`� a 0 w 0 z z O N O oa m 0 v) z �a Lf) Q Lu _ = Lu G O z x Lu 0- Q km E N G I N E E R I N G 5725 NORTH DISCOVERY WAY BOISE, IDAHO 83713 PHONE (208) 639-6939 kmengllp.com DESIGN BY: KAC DRAWN BY: KAC CHECKED BY: AY DATE: FEBRUARY 2022 PROJECT: 21-023 SHEET NO L1.0 CWT-,)- APPROVED 0911X22 LANDSCAPE PLAN 0 40 80 120 Plan Scale: 1" = 40' \ F KEY NOTES (TYPICAL) (V ���..•�������.,,,� .a �E0F1,D '•. 1. INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE AT ALL ` � . •••••• 9, ,• O2. TREES WITHIN TURF AREAS. ,SAY CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR VISIONTRIANGLE. 4—n THE MAXIMUM HEIGHT OF ANY VEGETATIVE GROUND COVER AT MATURITY WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE ADJACENT STREET GRADE. • J.A-16S.'7 J�••••7/28/22• 3. NOT USED. %, - Q��. �'4�9,Np„AQ�P``• 4. TREES PLANTED IN PARK STRIPS TO BE CENTERED IN STRIP. 5. 10' ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR ZONE OF ALL ACHD STORM DRAIN PIPES, STRUCTURES, OR FACILITIES. 6. 10' MULTI —USE PATHWAY. SEE CIVIL PLANS. 7. EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN, PROTECT, AND OR ADJUST AS SHOWN. CONTRACTOR SHALL FIELD VERIFY LIMITS OF DISTURBANCE AND PATCH BACK ALONG PHASE BOUNDARY AS NECESSARY. TRANSITION BETWEEN NEW AND EXISTING LANDSCAPE SHALL BE NON RECOGNIZABLE AND COHESIVE WHEN FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING LANDSCAPE PLANTING AREAS AND IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW CONSTRUCTION. THE CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING o ao ti o ti o N N CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN OPERATION OF THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION. 1NT SCHEDULE Z z � � S QTY BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS N z a z U U U 55 ACER TRUNCATUM'PACIFIC SUNSET'TM 2" CAL. B&B 35'X30' CLASS II Ln z o F w w w uu PACIFIC SUNSET MAPLE j o w N N N w ~ o 0 o u z0 - - - o 40 CARPINUS BETULUS 2" CAL. B&B 50'X40' CLASS II o z 0u u > z > z w z EUROPEAN HORNBEAM x LL z r o u a v 20 GLEDITSIA TRIACANTHOS'IMPERIAC 2" CAL. B&B 40'X35' CLASS II u a F o IMPERIAL HONEYLOCUST x a 17 PYRUS CALLERYANA'REDSPIRE' 2" CAL. B&B 40'X25' CLASS II REDSPIRE GALLERY PEAR JND COVERS QTY BOTANICAL/COMMON NAME 43,781 SF TURF SOD RHIZOMATOUS RHIZOMATOUS TALL FESCUE R CONT SOD QTY BOTANICAL/COMMON NAME CONT 7,538 SF SHRUBS AND PERENNIALS, OR GRASSES NA SHRUBS SIZE MATURE HXW CARYOPTERIS X CLAN DON ENSIS'BLUE MIST' 2GAL. 3'X3' BLUE MIST SHRUB JUNIPERUS HORIZONTALIS'BLUE CHIP' 2 GAL. 1'X6' BLUE CHIP JUNIPER N JUNIPERUS SCOPULORUM'BLUE ARROW' 6'-8'B&B 12'X3' BLUE ARROW JUNIPER PHYSOCARPUS OPULIFOLIUS'SUMMER WINE' 2 GAL. 5'X5' O SUMMER WINE NINEBARK z RHAMNUS FRANGULA'FINE LINE' 2 GAL. 6'X3' FINE LINE BUCHTHORN 7 ROSA X'NOARE' 2 GAL. 3'X3' L FLOWER CARPET RED GROUNDCOVER ROSE O SPIRAEAX BUMALDA'GOLDFLAME' 2 GAL. 3'X3' GOLDFLAME SPIREA L) O z ANNUALS/PERENNIALS SIZE MATURE HXW > = Q 0 ECHINACEA PURPUREA 1 GAL. 5'X2' Q PURPLE CONEFLOWER co HEMEROCALLIS X'STELLA DE ORO' 1 GAL. 1'X2' = _ LJJ STELLA DE ORO DAYLILY a- NEPETA X FAASSENII'JUNIOR WALKER' 1 GAL. 1.5' X 4' Ln Z if < JUNIOR WALKER CATMINT U RUDBECKIA FULGIDA'GOLDSTRUM' 1 GAL. 2'X2' CONEFLOWER L ) Q Lf) SALVIA NEMOROSA'MAY NIGHT' 1 GAL. 2'X2' MAY NIGHT SAGE z ZAUSCHNERIA GARRETTII'ORANGE CARPET' 1GAL. .5'X2' HUMMINGBIRD TRUMPET J GRASSES SIZE MATURE HXW CALAMAGROSTIS X ACUTIFLORA'KARL FOERSTER' 1 GAL. 4'X2' O FEATHER REED GRASS 7 HELICTOTRICHON SEMPERVIRENS'BLUE OATS' 1GAL. 3'X3' L BLUE OAT GRASS X MISCANTHUS SIN ENSIS'MORNING LIGHT' 1 GAL. 5'X4' EULALIA GRASS PANICUM VIRGATUM'HEAVY METAL' BLUE SWITCH GRASS 1 GAL. 4'X2' Q )—BVC WOOD TREE 3TAKES(MIN. 6' HT; CHAINLOCK TREE TIES REMOVE TREATED YNTHETIC BURLAP COMPLETELY. REMOVE ANY SOIL AND/OR MULCH AWAY FROM TREE CROWN AFTER INSTALLATION REMOVE DEAD/ DAMAGED BRANCHES AND PRUNE TO INTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS; IMPROPERLY PRUNED TREES (AS DETERMINED BY THE LANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACE. TRUNK FLARE. LOCATE PRIOR TO PLANTING. FLARE SHALL BE VISIBLE AFTER PLANTING. MULCH PER PLAN KEEP 1"-2" AWAY FROM TRUCK FLARE FINISH GRADE 3" HT. WATERING BASING BERM FERTILIZER TABLETS FOLD BACK BURLAP FROM TOP j OF ROOTBALL. REMOVE WIRE BASKET. BACKFILL SOIL MIX GENTLY PACK BACKFILL USING WATER TO SETTLE SOIL AROUND ROOTBALL ROOTBALL ON UNDISTURBED SOIL THAN ROOTBALL AT BASE AND A MIN. 3 TIMES WIDER THAN ROOTBALL AT FINISH GRADE. DEPTH SHALL BE NOTES: SAME AS THE ROOTBALL. 1. THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR. ALL 1 STAKING SHALL BE REMOVED AT THE END OF THE ONE YEAR WARRANTY PERIOD, DECIDUOUS TREE PLANTING AND STAKING DETAIL NTS Im E N G I N E E R I N G 5725 NORTH DISCOVERY WAY BOISE, IDAHO 83713 PHONE (208) 639-6939 kmengllp.tom DESIGN BY: KAC DRAWN BY: KAC CHECKED BY: AY DATE: FEBRUARY 2022 PROJECT: 21-023 SHEET NO. L2.0