HomeMy WebLinkAboutRevised Landscape Plan V1DWRIDIA y-
APPROVED
0911X22
LANDSCAPE SITE PLAN
0 80 160 240
Plan Scale: 1" = 80'
CONTACT INFORMATION
OWNER
BRIGHTON DEVELOPMENT INC.
2929 W. NAVIGATOR DR., SUITE 400
MERIDIAN, IDAHO 83642
PHONE: (208) 378-4000
CONTACT: JON WARDLE
EMAIL: jwardle®brightoncorp.com
LANDSCAPE CONSULTANT
KM ENGINEERING, LLP
5725 NORTH DISCOVERY WAY
BOISE, IDAHO 83713
PHONE: (208) 639-6939
FAX: (208) 639-6930
CONTACT: ALYSSA YENSEN, PLA
EMAIL: ayensenOkmengllp.com
14�
GENERAL LANDSCAPE NOTES
1. VERIFICATION OF TOTAL LANDSCAPE MATERIAL QUANTITIES AS SHOWN ON THIS
LANDSCAPE PLAN AND IN THE PLANT SCHEDULE SHALL BE THE RESPONSIBILITY OF
THE LANDSCAPE CONTRACTOR. IF QUANTITIES LISTED DO NOT CORRELATE WITH WHAT
IS SHOWN ON THE PLAN, THE QUANTITIES SHOWN ON THE PLAN SHALL GOVERN. THIS
INCLUDES, BUT IS NOT LIMITED TO TREE, SHRUB, ROCK, TOPSOIL, MULCH, SEED OR
SOD, EDGING, AND DRIP LINE QUANTITIES.
2. IMMEDIATELY AFTER AWARD OF CONTRACT, NOTIFY THE LANDSCAPE ARCHITECT OF
AVAILABLY OF SPECIFIED PLANT MATERIAL FROM COMMERCIAL NURSERIES. IF A
SPECIFIED PLANT IS NOT AVAILABLE, THE LANDSCAPE ARCHITECT WILL PROVIDE
ALTERNATE PLANT MATERIAL SELECTIONS. SUCH CHANGES SHALL NOT ALTER THE
ORIGINAL BID PRICE UNLESS A CREDIT IS DUE TO THE OWNER.
3. CONTRACTOR SHALL LOCATE AND IDENTIFY EXISTING UNDERGROUND AND OVERHEAD
UTILITIES WITHIN CONTRACT WORK AREAS PRIOR TO CONSTRUCTION. CONTACT DIG
LINE, INC. 0 1.800.342.1885. PROVIDE ADEQUATE MEANS OF PROTECTION OF
UTILITIES AND SERVICES DESIGNATED TO REMAIN. REPAIR UTILITIES DAMAGED DURING
SITE WORK OPERATIONS AT CONTRACTOR'S EXPENSE.
4. PROVIDE REQUIRED SOIL EROSION CONTROL MEASURES THROUGHOUT THE DURATION OF
THE CONTRACT PERIOD. SHOULD THERE BE EXISTING SOIL EROSION CONDITIONS THAT
REQUIRE MITIGATION, NOTIFY THE RESPONSIBLE PERSON IMMEDIATELY. FAILURE TO
NOTIFY THE RESPONSIBLE PERSON IMPLIES ACCEPTANCE OF THE SITE IN ITS EXISTING
CONDITION.
5. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING ALL PLANTED AREAS.
ALL DELETERIOUS MATERIAL SUCH AS ROCK, TRASH, CONSTRUCTION DEBRIS,
AGGREGATE BASE MATERIAL, ASPHALT, ETC.., SHALL BE REMOVED PRIOR TO ANY FILL
OPERATIONS. FINISH GRADES TO BE SMOOTH AND EVEN. GRADIENTS TO REMOVE LOW
AND HIGH POINTS AND TO PROVIDE POSITIVE DRAINAGE.
6. FILL ALL PLANTING AREAS WITH CLEAN EARTHEN FILL, AS PER SPECIFICATIONS. SOIL
SHALL BE FREE OF HEAVY, STIFF CLAY AND ANY DELETERIOUS MATERIAL OVER ONE
INCH IN SIZE. REUSE EXISTING SURFACE TOPSOIL IF AVAILABLE.
7. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC
MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS, OR OTHER FOREIGN
MATERIALS AND A PH OF 5.5 TO 7.0. IF ON -SITE TOPSOIL DOES NOT MEET THESE
MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: PROVIDE APPROVED
IMPORTED TOPSOIL OR, AMEND THE ON -SITE TOPSOIL.
8. TOPSOIL DEPTHS SHALL BE AS FOLLOWS (WHERE APPLICABLE): LAWN AREAS-6" MIN.;
PLANTER BEDS - 12" MIN.; CURB ISLANDS - 18" MIN.ALL PLANTING BEDS SHALL BE
TREATED WITH A PRE -EMERGENT HERBICIDE.
9. FINISH GRADES FOR LANDSCAPE AREAS TO BE SMOOTH AND EVEN GRADIENTS WITH
POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN. SLOPES FOR TURF
AREAS SHALL NOT EXCEED 3:1.
10. PRE -EMERGENT HERBICIDE SHALL BE APPLIED PER MANUFACTURER'S
RECOMMENDATIONS AND SHALL OCCUR AFTER TOPSOIL PLACEMENT AND PRIOR TO
INSTALLATION OF PLANT MATERIALS AND MULCH.
11. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR
TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN HEALTHY GROWING
CONDITION.
12. ALL WRAPPING MATERIAL SHALL BE CUT AND REMOVED FROM AROUND THE UPPER
PORTION OF THE ROOT BALL. METAL BASKET WIRES AND BURLAP SHALL BE PULLED
BACK AND TUCKED UNDER THE EDGES OF THE SAUCER RINGS ON ALL TREES AND
LARGE SHRUBS. ALL SYNTHETIC BURLAP SHALL BE REMOVED FROM ROOT BALLS
PRIOR TO BACKFILLING.
13. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING
AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANT MATERIAL FOUND
DEAD OR NOT IN HEALTHY CONDITION IMMEDIATELY WITH COMPARABLE SIZE AND
SPECIES AT NO COST TO THE OWNER.
14. FERTILIZE ALL TREES AND SHRUBS WITH AGRIFORM PLANTING TABLETS. QUANTITY PER
MANUFACTURERS RECOMMENDATIONS.
15. CONTRACTOR'S MAINTENANCE SHALL INCLUDE:
• PRUNING, CULTIVATING, WEEDING, WATERING, AND APPLICATION OF APPROPRIATE
INSECTICIDES AND FUNGICIDES NECESSARY TO MAINTAIN PLANTS FREE OF INSECTS AND
DISEASE UNTIL FINAL ACCEPTANCE BY OWNER.
• RE -SET SETTLED PLANTS TO A PROPER GRADE AND POSITION.
• RESTORE PLANTING SAUCER AND ADJACENT MATERIAL AND REMOVE AND REPLACE
DEAD MATERIAL.
• TIGHTEN AND REPAIR GUY WIRES AND STAKES AS REQUIRED ONLY IF ORIGINALLY
NEEDED.
• CORRECT DEFECTIVE WORK AS SOON AS POSSIBLE AFTER DEFICIENCIES BECOMES
APPARENT AND WEATHER AND SEASON PERMIT.
ACHD LANDSCAPE NOTES
1. TREES SHALL NOT BE PLANTED WITHIN THE 10' CLEAR ZONE OF ALL ACHD STORM
DRAIN PIPE, STRUCTURES, OR FACILITIES.
2. SEEPAGE BEDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE
CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM.
NOTE: CALCULATIONS SHOWN BELOW ARE TO DETERMINE THE REQUIRED NUMBER OF OPEN
SPACE TREES PER CITY OF MERIDIAN UDC AND ARE NOT OPEN SPACE CALCULATIONS.
REFER TO THE OPEN SPACE EXHIBIT FOR OFFICIAL QUALIFIED OPEN SPACE CALCULATIONS.
STREET TREE CALCULATIONS (1TREE/35 LF)
STREET NAME
MIN.
BUFFER
WIDTH
LF
CALC
REQ
PRVD
S.APEX AVE.
20'
1073
1073 LF/35
31.00
32.00
S. HOPE AVE.
13.5'
1073
1073 LF/35
31.00
32.00
S. ASPIRATION AVE.
15'
1070
1070 LF/35
31.00
32.00
E. CRESCENDO ST.
13.5'
1253
EXCLUDES GAS
EASEMENT
1253 LF/35
36.00
36.00
TOTAL STREET TREES
129.00
132.00
MITIGATION REQUIREMENTS
THERE ARE NO HEALTHY TREES > 4" CAL. PROPOSED FOR REMOVAL
TOTAL TREES REQUIRED/PROVIDED
129.0
132.0
GENERAL IRRIGATION NOTES
1. NO GUARANTEE IS MADE THAT ALL EXISTING UNDERGROUND UTILITIES ARE SHOWN, OR SHOWN
CORRECTLY. CONTRACTOR SHALL VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF
ANY DEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING UTILITIES SHALL
BE CONTRACTOR'S RESPONSIBILITY.
2. THE CONTRACTOR IS RESPONSIBLE TO FURNISH AND INSTALL A COMPLETE IRRIGATION
SYSTEM WHICH PROVIDES ADEQUATE WATER COVERAGE TO ALL LAWN AND PLANTING
AREAS. THE WORK SHALL CONSIST OF PROVIDING AND INSTALLING ALL MATERIALS
NECESSARY FOR A COMPLETE SYSTEM INCLUDING POINT OF CONNECTION, PIPE,
VALVES, FITTINGS, HEADS, AUTOMATIC CONTROLS, AND ALL ASSOCIATED LABOR.
3. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FOR THIS WORK
4. ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS.
5. INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWS AND ORDINANCES.
6. POINT OF CONNECTION: COMPLY WITH REQUIREMENTS OF UTILITY SUPPLYING WATER
FOR PREVENTION OF BACKFLOW AND BACK-SIPHONAGE
7. COVERAGE; THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE ONE HUNDRED
PERCENT (100%) COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING
AS APPROPRIATE.
B. MATCHED PRECIPITATION RATES: SPRINKLER HEADS SHALL HAVE MATCHED PRECIPITATION
RATES WITHIN EACH CONTROL VALVE.
9. IRRIGATION DISTRICTS: SPRINKLER HEADS IRRIGATING LAWN OR OTHER HIGH WATER
DEMAND AREAS SHALL BE CIRCUITED SO THAT THEY ARE ON SEPARATE ZONES FROM
THOSE IRRIGATING TREES, SHRUBS, OR OTHER REDUCED WATER DEMAND AREAS.
10. OVERSPRAY: SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO
IMPERVIOUS SURFACES SUCH AS STREETS, SIDEWALKS, DRIVEWAYS, AND PARKING
AREAS.
11. PRIOR TO COMMENCING WORK, CONTRACTOR TO CONFIRM PSI IS ADEQUATE TO
FURNISH AND INSTALL A COMPLETE IRRIGATION SYSTEM WHICH PROVIDES ADEQUATE
WATER COVERAGE TO ALL LAWN AND PLANTING AREAS. SHOULD THE PSI BE LESS
THAN ADEQUATE, NOTIFY THE ARCHITECT IMMEDIATELY. IN THE EVENT THAT THE
ARCHITECT IS NOT NOTIFIED PRIOR TO THE START OF CONSTRUCTION, THE CONTRACTOR
SHALL ASSUME FULL RESPONSIBILITY FOR ANY NECESSARY REVISIONS.
12. WHERE APPLICABLE, LABEL ALL IRRIGATION RISERS, FAUCETS, VALVE BOXES, AND
VAULTS WITH DURABLE TAGS CARRYING THE WARNING "DANGER -UNSAFE WATER OR
NON -POTABLE WATER."
13.INSTALL ALL PIPING AND VALVES IN PLANTING AREAS WHERE POSSIBLE, AND LOCATE
ELECTRIC CONTROL AND QUICK COUPLING VALVES IN GROUND COVER/SHRUB AREAS,
6" TO 12" AWAY FROM EDGE OF PAVEMENT FOR EASE OF ACCESS.
14. PROVIDE UNDERGROUND IRRIGATION SYSTEM AS A COMPLETE UNIT PRODUCED BY A
SINGLE ACCEPTABLE MANUFACTURER, INCLUDING HEADS, VALVES, CONTROLS, AND
ACCESSORIES.
15. A MIN. OF 4" POP -UPS ARE TO BE USED IN ALL LAWN AREAS. DRIP IRRIGATION TO
BE USED IN ALL PLANTER BEDS.
16. THE IRRIGATION CONTRACTOR IS RESPONSIBLE TO SIZE CIRCUIT PIPING. WATER
VELOCITY IN ALL PIPES SHALL NOT EXCEED FIVE FEET PER SECOND. MINIMUM PIPE
SIZE TO BE 1".
17. CONTRACTOR IS RESPONSIBLE FOR INSTALLING SLEEVES UNDER ALL ROADWAY,
PARKING, AND WALKWAY SURFACES. EXTEND 6" MINIMUM BEYOND SURFACE EDGE.
IDENTIFY ENDPOINTS OF SLEEVING.
18. ALL IRRIGATION HEADS LOCATED ADJACENT TO ROAD SURFACES NOT PROTECTED BY A
VERTICAL CONCRETE CURB SHALL BE PLACED 18" FROM THE EDGE OF THE ROAD
SURFACE.
19. WHERE APPLICABLE, CONTRACTOR IS RESPONSIBLE TO PROVIDE 120 VOLT POWER AND
ALL REQUIRED CIRCUITS FROM THE ELECTRICAL PANEL TO THE IRRIGATION CONTROLLER.
SIZE WIRE AND CONDUIT AS REQUIRED.
20. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING IRRIGATION COMPONENTS
DAMAGED AS A RESULT OF NEW CONSTRUCTION, INCLUDING ADJACENT PROPERTIES.
REPAIR INCLUDES BUT IS NOT LIMITED TO PIPING, VALVES, HEADS, DRIP COMPONENTS,
CONTROL WIRES AND EQUIPMENT, AND SLEEVES. IF APPLICABLE, IRRIGATION CONTRACTOR
SHALL ENSURE THAT THE EXISTING IRRIGATION SYSTEM REMAINS OPERABLE DURING
CONSTRUCTION AND THAT FOLLOWING CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM
OPERATES AS GOOD, OR BETTER THAN EXISTED PRIOR TO THIS PROJECT.
21. CONTRACTOR SHALL REPLACE, AT NO ADDITIONAL COST TO THE OWNER, PLANT MATERIALS
DAMAGED DURING EXECUTION OF THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS
FAILURE TO MAINTAIN OPERATION OF THE EXISTING SYSTEM DURING THE COARSE OF
CONSTRUCTION.
22. LANDSCAPE ARCHITECT IS NOT RESPONSIBLE FOR DISCREPANCIES BETWEEN DESIGN
DRAWINGS AND ACTUAL SITE CHARACTERISTICS. CONTRACTOR SHALL FIELD VERIFY ALL
INFORMATION PROVIDED ON DRAWINGS. CONTRACTOR SHALL STOP CONSTRUCTION AND
CONTACT THE OWNER IMMEDIATELY FOR FURTHER DIRECTION IF DISCREPANCIES OCCUR.
23. UPON COMPLETION, AND PRIOR TO FINAL PAYMENT, THE IRRIGATION CONTRACTOR SHALL
PROVIDE A NEAT AND LEGIBLE AS -CONSTRUCTED IRRIGATION PLAN, AN OPERATION AND
MAINTENANCE MANUAL, AND UP TO (8) HOURS OF ORIENTATION AND/OR TRAINING FOR THE
OWNERS MAINTENANCE AND OPERATIONS STAFF.
24. THE ENTIRE SYSTEM SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF
IT'S ACCEPTANCE. REPAIR OR REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THAT YEAR
SHALL BE COMPLETED PROMPTLY BY THE IRRIGATION CONTRACTOR AT NO ADDITIONAL COST TO
THE OWNER.
25. CONTRACTOR SHALL PROVIDE, AT NO ADDITIONAL COST TO THE OWNER, SPRING START UP AND
WINTERIZATION DURING THE GUARANTEE PERIOD.
PLANT SCHEDULE
SEE 11.1 FOR FULL PLANT SCHEDULE
TREES
QTY
BOTANICAL/COMMON NAME
SIZE
0
55
ACER TRUNCATUM'PACIFIC SUNSET'TM
2" CAL. B&B
PACIFIC SUNSET MAPLE
0
40
CARPINUS BETULUS
2" CAL. B&B
EUROPEAN HORNBEAM
C)
20
G LEDITSIA TRIACANTHOS'IMPERIAL'
2" CAL. B&B
IMPERIAL HONEYLOCUST
17
PYRUS CALLERYANA'REDSPIRE'
2" CAL. B&B
REDSPIRE CALLERY PEAR
GROUND COVERS QTY BOTANICAL/COMMON NAME CONT
43,781 SF TURF SOD RHIZOMATOUS SOD
RHIZOMATOUS TALL FESCUE
OTHER QTY BOTANICAL/COMMON NAME CONT
■ 7,538 SF SHRUBS AND PERENNIALS, OR GRASSES NA
.a' �EOFID •'�.
Q.
. 'SSA Ygy�
• 1.A-165.'7 • ���
••�•7 /28/22 ••' C
4ASCA4� •`�
a
0
w
0
z
z
O
N O
oa
m 0
v) z
�a
Lf) Q
Lu _
= Lu
G
O
z
x
Lu
0-
Q
km
E N G I N E E R I N G
5725 NORTH DISCOVERY WAY
BOISE, IDAHO 83713
PHONE (208) 639-6939
kmengllp.com
DESIGN BY:
KAC
DRAWN BY:
KAC
CHECKED BY:
AY
DATE:
FEBRUARY 2022
PROJECT:
21-023
SHEET NO
L1.0
CWT-,)-
APPROVED
0911X22
LANDSCAPE PLAN
0 40 80 120
Plan Scale: 1" = 40'
\
F
KEY NOTES (TYPICAL) (V
���..•�������.,,,�
.a �E0F1,D '•.
1.
INSTALL 3' DIAMETER SHOVEL CUT TREE RING, WITH BARE EARTH SURFACE AT ALL
` � . •••••• 9,
,•
O2.
TREES WITHIN TURF AREAS.
,SAY
CLEAR VISION TRIANGLE. NO TREES SHALL BE PLANTED WITHIN A CLEAR VISIONTRIANGLE.
4—n
THE MAXIMUM HEIGHT OF ANY VEGETATIVE GROUND COVER AT MATURITY
WITHIN THE CLEAR VISION TRIANGLE SHALL BE 3' FROM THE ADJACENT STREET GRADE.
• J.A-16S.'7
J�••••7/28/22•
3.
NOT USED.
%, - Q��.
�'4�9,Np„AQ�P``•
4.
TREES PLANTED IN PARK STRIPS TO BE CENTERED IN STRIP.
5.
10' ACHD FACILITY CLEAR ZONE. TREES SHALL NOT BE PLANTED WITHIN THE 10'
CLEAR ZONE OF ALL ACHD STORM DRAIN PIPES, STRUCTURES, OR FACILITIES.
6.
10' MULTI —USE PATHWAY. SEE CIVIL PLANS.
7.
EXISTING LANDSCAPING AND IRRIGATION TO REMAIN. RETAIN, PROTECT, AND OR
ADJUST AS SHOWN. CONTRACTOR SHALL FIELD VERIFY LIMITS OF DISTURBANCE AND
PATCH BACK ALONG PHASE BOUNDARY AS NECESSARY. TRANSITION BETWEEN NEW
AND EXISTING LANDSCAPE SHALL BE NON RECOGNIZABLE AND COHESIVE WHEN
FINISHED. CONTRACTOR IS RESPONSIBLE TO REPAIR ALL EXISTING LANDSCAPE
PLANTING AREAS AND IRRIGATION COMPONENTS DAMAGED AS A RESULT OF NEW
CONSTRUCTION. THE CONTRACTOR SHALL ENSURE THAT THE EXISTING IRRIGATION
SYSTEM REMAINS OPERABLE DURING CONSTRUCTION AND THAT FOLLOWING
o
ao
ti
o
ti
o
N
N
CONSTRUCTION, THE EXISTING IRRIGATION SYSTEM OPERATES AS GOOD, OR BETTER
THAN EXISTED PRIOR TO THIS PROJECT. CONTRACTOR SHALL REPLACE, AT NO
ADDITIONAL COST TO THE OWNER, PLANT MATERIALS DAMAGED DURING EXECUTION OF
THIS PROJECT OR DAMAGED DUE TO THE CONTRACTORS FAILURE TO MAINTAIN
OPERATION OF THE EXISTING SYSTEM DURING THE COURSE OF CONSTRUCTION.
1NT SCHEDULE
Z
z
�
�
S
QTY BOTANICAL/COMMON NAME SIZE MATURE HXW CLASS
N
z
a
z
U
U
U
55 ACER TRUNCATUM'PACIFIC SUNSET'TM 2" CAL. B&B 35'X30' CLASS II
Ln
z
o
F
w
w
w uu
PACIFIC SUNSET MAPLE
j
o
w
N
N
N w
~
o
0
o u
z0
-
-
- o
40 CARPINUS BETULUS 2" CAL. B&B 50'X40' CLASS II
o
z
0u
u
>
z
>
z
w z
EUROPEAN HORNBEAM
x
LL
z
r
o
u
a
v
20 GLEDITSIA TRIACANTHOS'IMPERIAC 2" CAL. B&B 40'X35' CLASS II
u
a
F
o
IMPERIAL HONEYLOCUST
x
a
17 PYRUS CALLERYANA'REDSPIRE' 2" CAL. B&B 40'X25' CLASS II
REDSPIRE GALLERY PEAR
JND COVERS QTY BOTANICAL/COMMON NAME
43,781 SF TURF SOD RHIZOMATOUS
RHIZOMATOUS TALL FESCUE
R
CONT
SOD
QTY BOTANICAL/COMMON NAME
CONT
7,538 SF SHRUBS AND PERENNIALS, OR GRASSES
NA
SHRUBS
SIZE
MATURE HXW
CARYOPTERIS X CLAN DON ENSIS'BLUE MIST'
2GAL.
3'X3'
BLUE MIST SHRUB
JUNIPERUS HORIZONTALIS'BLUE CHIP'
2 GAL.
1'X6'
BLUE CHIP JUNIPER
N
JUNIPERUS SCOPULORUM'BLUE ARROW'
6'-8'B&B
12'X3'
BLUE ARROW JUNIPER
PHYSOCARPUS OPULIFOLIUS'SUMMER WINE'
2 GAL.
5'X5'
O
SUMMER WINE NINEBARK
z
RHAMNUS FRANGULA'FINE LINE'
2 GAL.
6'X3'
FINE LINE BUCHTHORN
7
ROSA X'NOARE'
2 GAL.
3'X3'
L
FLOWER CARPET RED GROUNDCOVER ROSE
O
SPIRAEAX BUMALDA'GOLDFLAME'
2 GAL.
3'X3'
GOLDFLAME SPIREA
L)
O
z
ANNUALS/PERENNIALS
SIZE
MATURE HXW
>
=
Q
0
ECHINACEA PURPUREA
1 GAL.
5'X2'
Q
PURPLE CONEFLOWER
co
HEMEROCALLIS X'STELLA DE ORO'
1 GAL.
1'X2'
=
_
LJJ
STELLA DE ORO DAYLILY
a-
NEPETA X FAASSENII'JUNIOR WALKER'
1 GAL.
1.5' X 4'
Ln
Z
if
<
JUNIOR WALKER CATMINT
U
RUDBECKIA FULGIDA'GOLDSTRUM'
1 GAL.
2'X2'
CONEFLOWER
L )
Q
Lf)
SALVIA NEMOROSA'MAY NIGHT'
1 GAL.
2'X2'
MAY NIGHT SAGE
z
ZAUSCHNERIA GARRETTII'ORANGE CARPET'
1GAL.
.5'X2'
HUMMINGBIRD TRUMPET
J
GRASSES
SIZE
MATURE HXW
CALAMAGROSTIS X ACUTIFLORA'KARL FOERSTER'
1 GAL.
4'X2'
O
FEATHER REED GRASS
7
HELICTOTRICHON SEMPERVIRENS'BLUE OATS'
1GAL.
3'X3'
L
BLUE OAT GRASS
X
MISCANTHUS SIN ENSIS'MORNING LIGHT'
1 GAL.
5'X4'
EULALIA GRASS
PANICUM VIRGATUM'HEAVY METAL'
BLUE SWITCH GRASS
1 GAL.
4'X2'
Q
)—BVC WOOD TREE
3TAKES(MIN. 6' HT;
CHAINLOCK
TREE TIES
REMOVE TREATED
YNTHETIC BURLAP
COMPLETELY. REMOVE
ANY SOIL AND/OR
MULCH AWAY FROM
TREE CROWN AFTER
INSTALLATION
REMOVE DEAD/ DAMAGED
BRANCHES AND PRUNE TO
INTERNATIONAL SOCIETY OF
ARBORICULTURE STANDARDS;
IMPROPERLY PRUNED TREES
(AS DETERMINED BY THE
LANDSCAPE ARCHITECT)
SHALL BE REMOVED AND
REPLACE.
TRUNK FLARE. LOCATE PRIOR
TO PLANTING. FLARE SHALL
BE VISIBLE AFTER PLANTING.
MULCH PER PLAN KEEP
1"-2" AWAY FROM TRUCK
FLARE
FINISH GRADE
3" HT. WATERING BASING
BERM
FERTILIZER TABLETS
FOLD BACK BURLAP FROM
TOP j OF ROOTBALL.
REMOVE WIRE BASKET.
BACKFILL SOIL MIX GENTLY
PACK BACKFILL USING WATER
TO SETTLE SOIL AROUND
ROOTBALL
ROOTBALL ON UNDISTURBED
SOIL
THAN ROOTBALL AT BASE AND A
MIN. 3 TIMES WIDER THAN ROOTBALL
AT FINISH GRADE. DEPTH SHALL BE
NOTES: SAME AS THE ROOTBALL.
1. THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED
STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR. ALL
1 STAKING SHALL BE REMOVED AT THE END OF THE ONE YEAR WARRANTY PERIOD,
DECIDUOUS TREE PLANTING AND STAKING DETAIL
NTS
Im
E N G I N E E R I N G
5725 NORTH DISCOVERY WAY
BOISE, IDAHO 83713
PHONE (208) 639-6939
kmengllp.tom
DESIGN BY: KAC
DRAWN BY: KAC
CHECKED BY: AY
DATE: FEBRUARY 2022
PROJECT: 21-023
SHEET NO.
L2.0