27
EXISTING TYPE 2
STREET LIGHT
E BINGLEY DRIVE
EXISTING TYPE 2
STREET LIGHT
EXISTING TYPE 1
STREET LIGHT
16
13 12
14
1S
17
p
I
18
BLOCK 2
19
I
20
21
22
I
23
EXISTING TYPE 1
STREET LIGHT
24
25
I
I 26
N NO,t
SUBpl�I5I0 FUTURE PHASE \
SKYgREPK \ /
\ EXISTING TYPE 2 \ \
STREET LIGHT
BLOCK 2 \ \ \
11 10 \
9 \
8
7 EXISTING TYPE 2 \
STREET LIGHT
6
S \
4 BLOCK 2 \7�
28 29 \ \t
� BLOCK 2
\ 30
� 31
\ \ 32
\ 33
\ \ 34
\ \ 35
� 36
\ \ 37 38
FUTURE PHASE
\
1 / �
\ 3 /
/
i�
\ \RyURST 2// � Q
� -y
11
STORM DRAIN
SEEPAGE BED 1
1
10 BLOCK 5
� _ I
LA
Q
Q
z
z
F-
39
40
N
(I )
0 25 50 100 150
SCALE: 1" = 50'
STREET LIGHTING NOTES
1. ALL STREET LIGHT CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH THE CURRENT
VERSION OF THE ISPWC, THE MERIDIAN SUPPLEMENTAL SPECIFICATIONS TO THE ISPWC, AND
THE NATIONAL ELECTRIC CODE.
2. A STREET LIGHTING ELECTRICAL PERMIT SHALL BE OPENED PRIOR TO STARTING WORK. USE
THE ONLINE CITIZEN PORTAL AT HTTPS://CITIZENPORTAL.MERIDIANCITY.ORG/CITIZENACCESS/
TO OPEN A PERMIT AND REQUEST INSPECTIONS.
3. INSTALLATION WILL REQUIRE INSPECTIONS FOR THE CONCRETE BASE REINFORCING, BEDDING,
BACKFILL, AND FOR THE POLE AND ASSOCIATED WIRING.
4. STREET LIGHT BASES SHALL BE LOCATED 10' MIN. FROM TREES, 5' MIN. FROM FIRE
HYDRANTS AND 2' MIN. FROM WATER METERS.
5. KEEP ACCURATE NOTES OF CONDUIT, JUNCTION BOX LOCATIONS. ATTACH A REDLINED AS
BUILT DRAWING OF THIS PLAN SHEET TO THE STREET LIGHTING ELECTRICAL PERMIT, OR
SUBMIT A HARD COPY TO THE MERIDIAN PUBLIC WORKS DEPARTMENT PRIOR TO REQUESTING
FINAL INSPECTION.
6. CONTACT THE CITY TRANSPORTATION AND UTILITY COORDINATOR (208) 898-5500 FOR
QUESTIONS REGARDING UTILITY CONFLICTS, OR TO ACCESS LOCKED METER PEDESTALS.
KEYNOTES
O INSTALL TYPE 2 STREET LIGHT WITH 25' MOUNTING HEIGHT PER CITY
OF MERIDIAN STREET LIGHT DESIGN STANDARDS. LED FIXTURE TO BE
LEOTEK JR GCJ1 20H MV NW 2R DB 700 PCR7 WL SPB-DB OR
APPROVED EQUAL.
i
JW
E
>�o
6
m
�N3n
L"-
�^
o
�
v�
v�
c r
10 00rn
X 0
O
c
3�
m w
OU)
a O
N
uo
@1N
m
E�
m
r
m
rn
u
w
0
3
N
x
a
I
3
a
x
J
o
a
V
u
N
p
w
N
I
U
I
0
N
N
W
Z
J
O
Z
w
DESIGNED:
C.
GRAHAM
DRAWN:
L.
HAASE
CHECKED:
C.
GRAHAM
APPROVED:
C.
GRAHAM
z
PREPARED FOR:
0
G20
LLC
PO BOX 593
U
EAGLE,
ID 83616
Z)
c~
z
O
U
OLL
N
c
O
Lu
z
Z
Z
J
p
a
Q
Q
Lu
V
O
m
2
Z]
z
>
N
LuO
W
W
�
N
m
L
W
0-
CSW PROJECT NO.
22001
DRAWING DATE
06/02/2022
C8■0