HomeMy WebLinkAboutC-101 Detailed Site Plan V1SITE PLAN
�NOTES
ESEE PRESENT
LETOTHEENGINEER AT
SIGN. THE CONTRACTOR
PRIOR TO CONSTRUCTION
APPROVED TING CONDITIONS RELATED
RK FOR THIS PROJECT.
2. Mh' DDER, COAX PORT, AND
NIENUMNA:a2oas WN FOR REFERENCE ONLY.
CONFIRM THE EXACT
50-9"
RITWO AND EXISTING
EQUIPMENT AND STRUCTURES DEPICTED ON
THIS PLAN. BEFORE UTILIZING EXISTING CABLE
SUPPORTS, COAX PORTS, INSTALLING NEW
2
PORTS OR ANY OTHER EQUIPMENT,
m 2
CONTRACTOR SHALL VERIFY ALL ASPECTS OF
PROPOSED T-MOBILE METER 7RN I`
THE COMPONENTS MEET THE ATE
TO BE INSTALLED ON EXISTING
12'-B" GATE
SPECIFICATIONS.
SHARED METER BANK
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR
TO COORDINATE WITH THE T-MOBILE
ePROPOSED UNDERGROUND MD
C50 TELCO CONDUIT ROUTED IN
j.
EXISTING CMU WALL
��
REPRESENTATIVE AND LOCAL UTILITY COMPANY
TRENCH 5
I
V
FOR THE INSTALLATION OF CONDUITS,
PROPOSED T-MOBILE EQUIPMENT
OR CONDUCTORS, BREAKERS, DISCONNECTS,CE
ANY OTHER EQUIPMENT REQUIRED FOR
ei PAD WITHIN A 10' X 15' LEASE AREA
=
ELECTRICAL SERVICE. ALL ELECTRICAL WORK
SHALL BE PERFORMED IN ACCORDANCE WITH
PROPOSED T-MOBILE
-
LATEST EDITION OF THE STATE AND NATIONAL
ej
NT SHE
10 X 13 EQUIPMENT SHELTER
H
CODES, ORDINANCES AND REGULATIONS
WITHIN A 10' X 15' LEASE AREA
PROPOSED UNDERGROUND
APPLICABLE TO THIS PROJECT.
POWER CONDUIT ROUTED Gyp
e
N THE
8" PROPOSED T-MOBILE
4' X B' STOOP
3
PROPOSED T-MOBILE
(3)6244AWG HYBRID TRUNKS
°
Cb01
(ROUTED PER TOWER NOTE 2)
(REFER TO PROPOSED CABLE
LEGEND
LENGTH NOTE ON THIS PAGE)
® GROUNDINGTESTWELL
ATS AUTOMATIC TRANSFER SWITCH
B BOLLARD
CSC CELL SITE CABINET
D DISCONNECT
1 PROPOSED ICE BRIDGE
j
E ELECTRICAL
G50 (LENGTH 13'-W!)Lj
'
F FIBER
GEN GENERATOR
3 PROPOSED
G GENERATOR RECEPTACAL
Q{ GPS ANTENNA
HH, V HAND HOLE, VAULT
IS ICE BRIDGE
K KENTROX BOX
LC LIGHTING CONTROL
EXISTING 100,
M METER
CONCEALMENT TOWER
E
G
PB PULL BOX
PP POWER POLE
T TELCO
EXISTING ICE BRIDGE
�
TRN TRANSFORMER
BY OTHERS (TYP.)
`GRAVEL
CHAINLINK FENCE
SUREn
EXISTING 11'-5" X 20'-0"
EQUIPMENT SHELTER
BY OTHERS
PROPOSED CABLE LENGTH:
1. ESTIMATED LENGTH OF PROPOSED CABLE IS 10m.
ESTIMATED LENGTH OF CABLE WAS PROVIDED BY
CUSTOMER OR CALCULATED BY ADDING THE RAD
CENTER AND THE DISTANCE FROM THE SHELTER
ENTRY PLATE TO THE TOWER (ALONG THE ICE
BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF
15% (OF THE TWO PREVIOUS VALUES), COS DEFER
TO GREATEST CABLE LENGTH.
2. ROUTE PROPOSED CABLES ALONG SAME PATH AS
EXISTING CABLES AND IN ACCORDANCE WITH
STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE
DETAILED SITE PLAN
EXISTING CABLE SUPPORT STRUCTURES AS
PROVIDED FOR CARRIER TO ADEQUATELY SECURE
I SCALE: 1" =10'
CABLES, USING EITHER APPROPRIATELY SIZED
STAINLESS STEEL SNAPINSOR MOUNTING
0 10,
HARDWARE AND BRACKETS AS SPECIFIED BY CABLE
MANUFACTURER. OTHERWISE, ATTACH CABLES TO
HORIZONTAL OR DIAGONAL TOWER MEMBERS
SCALE: 1-10' (11X17)
USING PROPOSED STAINLESS STEEL ADAPTERS (DO
1"=5' (22X34)
NOT ATTACH TO TOWER LEG).
AMERIGAN TOWEM
1
.i
ANN
��
IQ EN61mi11G PROfES90NALS
326 TRYON ROAD
RALEIGH, NC 276033530
OFFICE: (919) 66W51
www.lepgroup.net
REV. DESCRIPTION BY DATE
AA PRELIMINARY SSK 04/1822
A 90%CONSTRUCTION SSP 06/09/22
0 100%CONSTRUCTION SRZ O6/23122
0
ATC SITE NUMBER:
415255
ATSITE NAME:
BOI FOXTAIL ID
T-MOBILE SITE NAME:
ATC F TAIL
SITEA E.
630 M IAN RD
MERI N D 36465902
SEAL:
�D L F�c
N
Q
v
p
15814
G1p�r�TE OF
�yAM M. PNO
0623M
T Mobile
DATE DRAWN:
06/2322
ATC JOB NO:
14049009
CUSTOMER NAME:
ATC FOXTAIL
CUSTOMER ID:
SLO3609A
DETAILED SITE PLAN
SHEETNUMBER:
REVISION:
C-101