Loading...
HomeMy WebLinkAboutG202_Trash Enclosure Details V1108'-0" T.O. CMU WORK FINISH FLOOR 100' - 0" SEE STRUCTURAL DRAWINGS 108'-0" T.O. CMU 109'-4" T.O. CMU 109'-4" T.O. CMU 108'-0" T.O. CMU INTEGRAL COLOR CONCRETE MASONRY UNIT- 8"x16"x8". COLOR TO MATCH BUILDING BLOCK ARCHITECTURAL PRECAST CONCRETE CAP ASPHALT AND/OR CONCRETE PAVING, SEE CIVIL DRAWINGS CONCRETE FOUNDATION, SEE STRUCTURAL DRAWINGS CONCRETE PAVING, SEE CIVIL DRAWINGS ENGINEERED FILL, SEE GEOTECHNICAL REPORT ______________ G202 9 HSS 4 X 2 X 3/16", ALL (4 SIDES), MITER AT CORNERS 2 X 2 X 3/16" LEDGER FRAME ALL 4 SIDES OF OPENING, MITER AT CORNERS HSS 4 X 2 X 3/16" MID RAIL 2" 6" 4' - 0" 4' - 0" B.O. TUBE B.O. TUBE B.O. TUBE 1 1/2" 18GA DECK, SPAN VERTICALLY PRIMED AND PAINTED STEEL 2 1/2" 1" 4" 4" NOTE: 1. SEE STRUCTURAL FOR CONNECTION/ PLACEMENT REQUIREMENTS FOR PRECAST CAPS 2. SEAL ALL JOINTS. COLOR TO MATCH BUILDING PRECAST SWING GATE. PRIME AND PAINT, ARCHITECT TO SELECT COLOR GATE DROP PIN(S) 1" INSIDE DIAMETER X 8" STEEL SLEEVE (1 OF 2) SET IN AND CONCRETE PAVING SLAB & PIER (COORDINATE PLACEMENT WITH STEEL GATE FABRICATOR. PROVIDE CAP AT BURIED END) PRECAST CAP 7 G202