HomeMy WebLinkAboutG202_Trash Enclosure Details V1108'-0"
T.O. CMU
WORK FINISH FLOOR
100' - 0"
SEE STRUCTURAL DRAWINGS
108'-0"
T.O. CMU
109'-4"
T.O. CMU
109'-4"
T.O. CMU
108'-0"
T.O. CMU
INTEGRAL COLOR CONCRETE
MASONRY UNIT- 8"x16"x8". COLOR
TO MATCH BUILDING BLOCK
ARCHITECTURAL PRECAST CONCRETE CAP
ASPHALT AND/OR CONCRETE PAVING,
SEE CIVIL DRAWINGS
CONCRETE FOUNDATION,
SEE STRUCTURAL DRAWINGS
CONCRETE PAVING, SEE CIVIL DRAWINGS
ENGINEERED FILL,
SEE GEOTECHNICAL REPORT
______________
G202
9
HSS 4 X 2 X 3/16", ALL (4 SIDES),
MITER AT CORNERS
2 X 2 X 3/16" LEDGER FRAME
ALL 4 SIDES OF OPENING,
MITER AT CORNERS
HSS 4 X 2 X 3/16" MID RAIL
2"
6" 4' - 0" 4' - 0"
B.O. TUBE
B.O. TUBE
B.O. TUBE
1 1/2" 18GA DECK, SPAN
VERTICALLY
PRIMED AND
PAINTED STEEL
2 1/2" 1"
4" 4"
NOTE:
1. SEE STRUCTURAL FOR CONNECTION/
PLACEMENT REQUIREMENTS FOR PRECAST CAPS
2. SEAL ALL JOINTS.
COLOR TO MATCH
BUILDING PRECAST
SWING GATE. PRIME AND PAINT,
ARCHITECT TO SELECT COLOR
GATE DROP PIN(S)
1" INSIDE DIAMETER X 8" STEEL SLEEVE (1 OF 2)
SET IN AND CONCRETE PAVING SLAB & PIER
(COORDINATE PLACEMENT WITH STEEL GATE
FABRICATOR. PROVIDE CAP AT BURIED END)
PRECAST CAP
7
G202