Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
R1_ldn6 V1
LDN6 6" Open and WallWash LED Non-IC New Construction Downlight ORDERING INFORMATION Example: LDN6 35/15 LO6AR LSS MVOLT EZ10 DOWNLIGHTING LDN6 Lead times will vary depending on options selected. Consult with your sales representative. Accessories: Order as separate catalog number. PS1055CP FMC Power Sentry batterypack, T20 compliant, field installable, 10w constant power EAC ISSM 375 Compact interruptible emergency AC power system EAC ISSM 125 Compact interruptible emergency AC power system GRA68 JZ Oversized trim ring with 8" outside diameter SCA6 Sloped Ceiling Adapter. Degree of slope must be specified (5D, 10D, 15D, 20D, 25D, 30D). Ex: SCA6 10D . Notes 1 Overall height varies based on lumen package; refer to dimensional chart on page 3. 2 Not available with finishes. 3 Not available with emergency options. 4 Must specify voltage 120V or 277V. 5 Available with clear (AR) reflector only. 6 12.5" of plenum depth or top access required for battery pack maintenance. 7 Specify voltage. ER for use with generator supply EM power. Will require an emergency hot feed and normal hot feed. 8 Fixture begins at 80% light level. Must be specified with NPS80EZ or NPS80EZ ER. Only available with EZ10 and EZ1 drivers. 9 Not available with CP, NPS80EZ, NPS80EZER, NPP16D, NPP16DER or N80 options. 10 NLTAIR2, NLTAIRER2 and NLTAIREM2 not recommended for metal ceiling installations. 11 Fixture height is 6.5" for all lumen packages with HAO. 12 Must specify voltage for 3000lm and above. 5000lm with marked spacing 24 L x 24 W x 14 H. Not available with emergency battery pack option. 13 Must specify D10 or D1 driver. Not available with nLight options. Not avail- able with CP. Not recommended for metal ceiling installation. Not for use with emergency backup power systems other than battery packs. 14 When combined with EZ1 or EZ10 drivers, can be used as a normal power sensing device for nLight AIR devices and lumiaires with EM options. Catalog Number Notes Type LDN6 Series Color temperature Lumens1 Aperture/Trim Color Finish Voltage LDN6 6" round 27/ 2700K 30/ 3000K 35/ 3500K 40/ 4000K 50/ 5000K 05 500 lumens 07 750 lumens 10 1000 lumens 15 1500 lumens 20 2000 lumens 25 2500 lumens 30 3000 lumens 40 4000 lumens 50 5000 lumens LO6 Downlight LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/03/22 LDN6 LDN6 35/10 LO6AR, input watts: 10.44, delivered lumens: 987.10, LM/W = 94.54, spacing criterion at 0= 1.02, test no. ISF 30716P262. LDN6 35/15 LO6AR, input watts: 17.52, delivered lumens: 1572.9, LM/W = 89.77, spacing criterion at 0= 1.02, test no. ISF 30716P265. LDN6 35/30 LO6AR, input watts: 34.75, delivered lumens: 3138.5, LM/W = 90.31, spacing criterion at 0= 1.02, test no. ISF 30716P274. PHOTOMETRY Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance Data at 30" Above Floor for a Single Luminaire 0° 20° 40° 60° 80° 200 400 600 800 Ave Lumens 0 5 15 25 35 45 55 65 75 85 90 876 905 971 720 330 110 1 1 0 0 0 89 269 322 214 87 4 1 0 0 Zone Lumens % Lamp 0° - 30° 0° - 40° 0° - 60° 0° - 90° 90° - 120° 90° - 130° 90° - 150° 90° - 180° 0° - 180° 680.7 LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/03/22 LDN6 Notes • Tested in accordance with IESNA LM-79-08. • Tested to current IES and NEMA standards under stabilized laboratory conditions. • CRI: 80 typical. * All dimensions are inches (centimeters) unless otherwise noted. LDN6 Nominal Lumens Lumens Wattage Lm/W 500 527.9 5.8 90.5 750 758.1 8.9 85.1 1000 950.1 10.4 91.0 1500 1514 17.5 86.4 2000 2006 22.5 89.1 2500 2504 28.3 88.6 3000 3021 34.8 86.9 4000 4008 44.3 90.6 5000 4975 57.7 86.3 LUMEN OUTPUT MULTIPLIERS - FINISH Clear (AR) White (WR) Black (BR) Specular (LS) 1.0 N/A N/A Semi-specular (LSS) 0.950 N/A N/A Matte diffuse (LD) 0.85 N/A N/A Painted N/A 0.87 0.73 LUMEN OUTPUT MULTIPLIERS - CCT 2700K 3000K 3500K 4000K 5000K 80CRI 0.950 0.966 1.000 1.025 1.101 HOW TO ESTIMATE DELIVERED LUMENS IN EMERGENCY MODE Use the formula below to estimate the delivered lumens in emergency mode Delivered Lumens = 1.25 x P x LPW P = Ouput power of emergency driver. P = 10W for PS1055CP LPW = Lumen per watt rating of the luminaire. This information is available on the ABL luminaire spec sheet. The LPW rating is also available at Designlight Consortium. LDN6 CP 21 5 16 (54.1) 16 13 16 (42.7) 9 1 16 (23.0) 14 9 16 (11.6) Aperture: 6-1/4 (15.9) Ceiling Opening: 7-1/8 (18.1) Overlap Trim: 7-1/2 (19.1) 11 3 16 (28.4) 9 7 16 (24.0) 11 LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/03/22 LDN6 ADDITIONAL DATA Capable Luminaire This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning. • All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency • This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background* • This luminaire is part of an A+ Certified solution for nLight control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control options marked by a shaded background* To learn more about A+, visit www.acuitybrands.com/aplus. *See ordering tree for details COMPATIBLE 0-10V WALL-MOUNT DIMMERS MANUFACTURER PART NO. POWER BOOSTER AVAILABLE Lutron® Diva® DVTV Diva® DVSCTV Nova T® NTFTV Nova® NFTV Leviton® AWSMT-7DW CN100 AWSMG-7DW PE300 AMRMG-7DW Leviton Centura Fluorescent Control System IllumaTech® IP7 Series Synergy® ISD BC SLD LPCS RDMFC Digital Equinox (DEQ BC) Douglas Lighting Controls WPC-5721 Entertainment Technology Tap Glide TG600FAM120 (120V) Tap Glide Heatsink TGH1500FAM120 (120V) Oasis 0A2000FAMU Honeywell EL7315A1019 EL7305A1010 EL7315A1009 (optional) HUNT Dimming Preset slide: PS-010-IV and PS-010-WH Preset slide: PS-010-3W-IV and PS-010-3W-WH Preset slide, controls FD-010: PS-IFC-010-IV and PS-IFC- 010-WH-120/277V Preset slide, controls FD-010: PS-IFC-010-3W-IV and PS-IFC-010-3W-WH-120/277V Remote mounted unit: FD-010 Lehigh Electronic Products Solitaire PBX PDM Electrical Products WPC-5721 Starfield Controls TR61 with DALI interface port RT03 DALInet Router WattStopper® LS-4 used with LCD-101 and LCD-103 The Sensor Switch JOT enabled solution offers a wireless, app-free approach to single room lighting control. JOT enabled products use Bluetooth® Low Energy (BLE) technology to enable wire- less dimming and switching. Diagram LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/03/22 LDN6 Choose Wall Controls nLight offers multiple styles of wall controls - each with varying features and user experience. Push-Button Wallpod Traditional tactile buttons and LED user feedback Graphic Wallpod Full color touch screen provides a sophisticated look and feel EXAMPLE Group Fixture Control* *Appiication diagram applies for fixtures with eldoLED drivers only. nPS 80 EZ Dimming/Control Pack (qty: 2 required) nPODM 2P DX Dual On/Off/Dim Push-Button WallPod nCM ADCX Daylight Sensor with Automatic Dimming Control nCM PDT 9 Dual Technology Occupancy Sensor Description: This design provides a dual on/off/dim wall station that enables manual control of the fixtures in Row A and Row B separately. Additionally, a daylight harvesting sensor is provided so the lights in Row B can be configured to dim automatically when daylight is available. An occupancy sensor turns off all lights when the space is vacant. nLight® Wired Controls Accessories: Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlight for complete listing of nLight controls. WallPod Stations Model number Occupancy sensors Model Number On/Off nPODM (Color) Small motion 360º, ceiling (PIR/dual Tech) nCM 9 / nCM PDT 9 On/Off & Raise/Lower nPOD DX (Color) Large motion 360º, ceiling (PIR/dual tech) nCM 10 / nCM PDT 10 Graphic Touchscreen nPOD GFX (Color) Wide View (PIR/dual tech) nWV 16 / nWV PDT 16 Photocell controls Model Number Wall Switch w/ Raise/Lower (PIR/dual tech) nWSX LV DX / nWSX PDT LV DX Dimming nCM ADCX Cat-5 cables (plenum rated) Model Number 10', CAT5 10FT CAT5 10FT J1 15, CAT5 15FT CAT5 15FT J1 B OPTIONAL nPS 80 EZ nPS 80 EZ nCM ADCX nCM PDT 9 nPODM 2P DX A A A C B C CAT-5e Cable Line Power Low Voltage Dimming Wires A B C WIRING KEY A B 08/18/22 A-2022-0120 LDN6 DOWNLIGHTING: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) www.lithonia.com © 2014-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/03/22 LDN6 UL924 Sequence of Operation The below information applies to all nLight AIR devices with an EM option. • EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds. • Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts. • Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing. nLight® AIR Control Accessories: Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlightair. Wall switches Model number On/Off single pole rPODB [color] On/Off two pole rPODB 2P [color] On/Off & raise/lower single pole rPODB DX [color] On/Off & raise/lower two pole rPODB 2P DX [color] On/Off & raise/lower single pole rPODBZ DX WH1 Notes 1 Can only be ordered with the RES7Z zone control sensor version. nLight AIR nLight AIR is the ideal solution for retrofit or new construction spaces where adding communication is cost prohibitive. The integrated nLight AIR rPP20 Power Pack is part of each Lithonia LDN Luminaire. These individually addressable controls offer the ultimate in flexibility during initial setup and for space repurposing. nLight AIR rPODB 2P DX Mobile Device 1. Install the nLight® AIR fixtures with embedded smart sensor 2. Install the wireless battery-powered wall switch 3. With CLAIRITY app, pair the fixtures with the wall switch and if desired, customize the sensor settings for the desired outcome Simple as 1,2,3 08/18/22 A-2022-0120