HomeMy WebLinkAboutA3.0 Ceiling Plans V1APPROVED ,__ OW05,22 LEGEND MASONRY UNIT (CMU) WALL CONSTRUCTION TO REMAIN. J EXISTING CONSTRUCTION TO REMAIN. EXISTING CONSTRUCTION TO - - BE REMOVED. NEW FULL -HEIGHT PARTITION WAIL. NO WORK THIS AREA U.O.N. FIXTURE LEGEND EXISTING SUSPENDED ACOUSTICAL 0 EXISTING LIGHT FIXTURE TO $ $ EXISTING / NEW LIGHT SWITCH. TILE CEILING (SATC). REMAIN. EXISTING SUSPENDED ACOUSTICAL TOLE CEILING (SATC) TO BE F - - X REMOVE / RELOCATE EXISTING © EXISTING / NEW CEILING MOUNT REMOVED. L(D)- - -1 LIGHT FIXTURE. MOTION DETECTOR SWITCH. NEW SUSPENDED ACOUSTICAL TILE (N) RELOCATED OR NEW LIGHT FIXTURE. NEW TO MATCH EXISTING BUILDING CEILING (SATC). STANDARD. (N)w2 NEW EXTERIOR WALL MOUNT LIGHT EXIT EXISTING LIGHTED EXIT SIGN / Qnz FIXTURE. �' EMERGENCY LIGHTING FIXTURE WITH BATTERY BACKUP. �X� r 7 F '_ REMOVE AND OR RELOCATE HVAC o (E) EXISTING, RECESSED DOWN [EXIT; REMOVE AND RELOCATE LIGHTED EXIT SIGN / EMERGENCY LIGHTING J SUPPLY /RETURN DIFFUSER. Ni LIGHT. _ FIXTURE WITH BATTERY BACKUP. EXISTING SUPPLY / RETURN HVAC FEX-rrl RELOCATED OR NEW LIGHTED EXIT SIGN / EMERGENCY LIGHTING DIFFUSER. FIXTURE WITH BATTERY BACKUP. ® NEW OR RELOCATED HVAC SUPPLY / RETURN DIFFUSER. M EXISTING EXHAUST FAN. 1 DEMOLITION CEILING PLAN SCALE: 1/8" = 14" KEYNOTES O 1. EXISTING OCCUPIED TENANT AREA. NO CEILING WORK THIS AREA. NOTE: NOT 7. NEW SUSPENDED ACOUSTICAL TILE CEILING (SATC). PROVIDE 15/16 WHITE ALL CEILING FIXTURES OR NO CEILING FIXTURES SHOWN. T-BAR GRID (2'x4') WITH 2'x4' TILE (MATCH BUILDING STANDARD). SUSPENDED 2. EXISTING GWB CEILING TO REMAIN. PATCH AND REPAIR AS REQUIRED. CEILING HEIGHT TO BE +10'-0"f OR AS REQUIRED (MATCH EXISTING CEILING 3. EXISTING OPEN CEILING. REMOVE ABANDONED FIXTURES TO POINT OF HEIGHT). EXTEND CEILING CONTINUOUS ACROSS ALL WALLS PER FLOOR PLAN AND PER WALL BRACE DETAILS. ALL SUSPENDED CEILINGS ARE PER GENERAL ORIGINATION. RE -CONFIGURE HVAC EQUIPMENT AS REQUIRED. NOTE A AND DETAIL 3/43.0. 4. REMOVE FRAMED GWB CEILING. REMOVE ABANDONED FIXTURES TO POINT OF 8, ORIGINATION. PROVIDE COMMERCIAL GRADE EXTERIOR WALL MOUNT LED LIGHT FIXTURE (DESIGN -BUILD BY ELECTRICAL CONTRACTOR, OWNER TO APPROVE FIXTURE). A. REMOVE FRAMED CEILING / HVAC PLATFORM AND SUSPEND HVAC UNIT FROM STRUCTURE ABOVE. 5. REMOVE ALL CEILING FIXTURES TO POINT OF ORIGINATION. REMOVE SUSPENDED ACOUSTICAL TILE CEILING. 6. EXISTING CONTINUOUS SUSPENDED ACOUSTICAL TILE CEILING (SATC) TO REMAIN. REMOVE EXISTING CEILING TILES. REMOVED ALL ABANDONED FIXTURES TO THE POINT OF ORIGINATION. RE -LEVEL GRID AS REQUIRED. REPLACE DAMAGED TRACK AS REQUIRED. RELOCATE OR PROVIDE NEW CEILING FIXTURES FIXTURES AS SHOWN OR AS REQUIRED. ALL CEILING FIXTURES (LIGHTS, HVAC DIFFUSERS) ARE TO BE CLEANED AND REPAIRED SO THAT THEY ARE IN FULL WORKING ORDER. ANY NEW CEILING FIXTURES TO MATCH EXISTING BUILDING STANDARD. ALL MODIFICATIONS TO THE SUSPENDED CEILING SHALL BE PER GENERAL NOTE A AND DETAIL 3/A3.0. GENERAL NOTES 8 A. SUSPENDED ACOUSTICAL TILE CEILING SYSTEMS (SATC) SHALL [(N)WI(l) BE INSTALED OR MODIFIED PER MANUFACTURER'S (N)wz REQUIREMENTS AND IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS INCLUDING THE 2018 IBC 808.1, ASTM C 635 AND ASTM C 636. N L N Lt N L N Lt B. ALL PLUMBING IS DESIGN BUILD BY THE CONTRACTOR. THE CONTRACTOR WILL BE REQUIRED TO SECURE A PLUMBING 7c:� PERMIT. PLUMBING FIXTURES ARE SCHEMATIC FOR LOCATION ONLY. ALL NEW FIXTURES TO MATCH EXISTING BUILDING STANDARDS U.N.O. CONTRACTOR TO PROVIDE THE OWNER N Lt N Lt N Lt N Lt PLUMBING FIXTURE CUT SHEET INFORMATION FOR REVIEW. ALL 7 7 PLUMBING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS AND WITH ALL nP• NP• Z APPLICABLE CODES AND STANDARDS INCLUDING THE 2018 IBC Nu NLt Nu NLt o 1 CHAPTER 29 AND THE 2017 IDAHO STATE PLUMBING CODE / UPC). C. ALL HVAC IS DESIGN BUILD BY THE CONTRACTOR. THE ALL H / CONTRACTOR WILL BE REQUIRED TO SECURE A HVAC PERMIT IF N u ® N u N u ® N u ° NEW EQUIPMENT IS ADDED OR EXISTING EQUIPMENT MODIFIED. E)wt W (THE RELOCATION OF EXISTING SUPPLY AND RETURN GRILLS IN A SUSPENDED CEILING DOES NOT REQUIRE A PERMIT.) ALL ° u HVAC EQUIPMENT AND DIFFUSER LOCATION IS SCHEMATIC ONLY. 2 ALL NEW FIXTURES TO MATCH EXISTING BUILDING STANDARDS N Lt N u N u N u (E)RI (E)RI - U.N.O. CONTRACTOR TO PROVIDE THE OWNER HVAC FIXTURE CUT SHEET INFORMATION FOR REVIEW. ALL HVAC TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH i N Lt N Lt N u E)u E)u u t N u N u MANUFACTURER'S REQUIREMENTS AND WITH ALL APPLICABLE - CODES AND STANDARDS INCLUDING THE 2018 IBC 1202 & (E), (E)u ( 1203 AND THE 2018 IMC. D. VENTILATION SHALL BE PROVIDED PER 2018 IMC SECTION 402 N Lt N Lt N u (E)u (E)u 1 A / (E)u u u N u N _1 N u (NATURAL VENTILATION) OR SECTION 405 (MECHANICAL VENTILATION). MECHANICAL VENTILATION SYSTEMS SHALL BE DESIGNED TO HAVE THE CAPACITY TO SUPPLY THE MINIMUM OUTDOOR AIRFLOW RATE DETERMINED IN ACCORDANCE WITH 2018 IMC TABLE 403.3.1.1 BASED ON THE OCCUPANCY OF N Lt M N LtTYR.TYP N u E)u E)u (E)L / (E)u E)11 u N u N _1 N u THE SPACE AND THE OCCUPANT LOAD OR OTHER PARAMETER Z1 AS STATED THEREIN. THE VENTILATION SYSTEM SHALL BE DESIGNED TO SUPPLY THE REQUIRED RATE OF VENTILATION AIR °� THETHE IS OC INUOUSLY PIED, EXCEPT IAS OTHERWIE STATED INOTHERWISE OBUILDING THER N u N u N u (E)u (E)u (E (E)L / (E)u E)u PROVISIONS OF THE 2018 IMC. N u E. ALL ELECTRICAL (POWER AND LIGHTING) IS DESIGN BUILD BY yv Z ® ® ILL BE REQUIRED TO CONTRACTOR.THE ELECCTRICAL PE MITE. CTOR ALL SECUREELECTRICAL FIXTURES AND i / ( N Lt N Lt N u E)u E)u i (E) / AZI (E)uA N Lt N u LOCATIONS ARE SCHEMATIC ONLY. CONTRACTOR TO / j j 7 7 COORDINATE FINAL DESIGN LAYOUT AND SWITCHING WITH THE OWNER. ALL NEW FIXTURES TO MATCH EXISTING BUILDING / STANDARDS. CONTRACTOR TO PROVIDE THE OWNER LIGHTING FIXTURE CUT SHEET INFORMATION FOR REVIEW. ALL �® N Lt �� (E)u (E)u )u , / (E l (E) / 1 j ELECTRICAL TO BE DESIGNED AND INSTALLED IN ACCORDANCE , �� % j TO INC INCLUDING THE 2018 0 8 BC ALL APPLICABLE CODESNANDCSTANDARDS REQUIREMENTS 1013, TYP / / 1204, CHAPTER 27 AND THE 2017 NEC. TYP. N L1 E LI E � L1 t / I/ (E 1 (E)L / 1 ILL � F. NEW INTERNALLY ILLUMINATED EXIT SIGNS SHALL BE LISTED /LI AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND 2018 IBC SECTION SIGNS2702. EXIT ILLUMINATEDLNEW % (E 1 � (E)L / / (E)u E)u 1 u ( t / E)u INTERNALLY ILLUMINATED XITSIG SSHALL NOTEXCE D 5 WATTS PER SIDE. - G. ALL FIRE HARM SYSTEM WORK IS DESIGN BUILD BY THE � CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR � � � � j � � �� R L1 �® IDENTIFYING THE SCOPE OF WORK TO THE OWNER. IF MODIFICATIONS ARE REQUIRED, THE CONTRACTOR WILL BE 1 (E) (E)u (E)LI REQUIRED TO SUBMIT DESIGN SHOP DRAWINGS TO THE BOISE CITY FIRE DEPARTMENT FOR PERMIT. ALL WORK TO BE IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS AND ALL 6 APPLICABLE CODES AND STANDARDS INCLUDING THE 2018 IBC SECTION 907, 2018 IFC, 2019 NFPA-72 AND THE 2017 NEC. 2 REFLECTED CEILING PLAN ^ H. ALL PHONE AND DATA SYSTEMS TO BE PROVIDED BY TENANT. CONTRACTOR TO PROVIDE ALL CONDUIT AND J-BOXES AS SCALE:1/8" = 1'-0" REQUIRED. ALL PHONE DATA LOCATIONS ARE SCHEMATIC ONLY, COORDINATE FINAL LOCATIONS OF OUTLETS WITH TENANT NORTH AND OWNER. ALL SYSTEMS TO BE INSTALLED PER MANUFACTURER'S REQUIREMENTS AND ALL APPLICABLE CODES AND STANDARDS INCLUDING THE 2017 NEC. I. ALL NEW OR RELOCATED CONTROLS (SWITCHES, OUTLETS, THERMOSTATS, ETC.) SHALL BE INSTALLED WITHIN ICC-ANSI ACCESSIBLE REACH RANGES: THE TOP OF THE CONTROL SHALL IBC INSTALLATION REQUIREMENTS - CATEGORY C / SPLAY BRACING: SEISMIC USE GROUP 2. - 4 WIRE CLUSTER, STARTING NOT BE HIGHER THAN 48 INCHES ABOVE FINISH FLOOR, THE BOTTOM OF THE CONTROL SHALL NOT BE INSTALLED LOWER INSTALL IN ACCORDANCE WITH ASTM E580 LIGHT TO POINT, SPACING, CONNECTION THAN 15 INCHES ABOVE FINISH FLOOR. MODERATE CISCA ZONES 0-2. STRENGTH CONNECTIONS AND HANGER WIRES: - AND COMPRESSION POSTS NOT - MAX. CEILING WEIGHT: 2.5 Ib/SF REQUIRED UNLESS CEILING - INTERSECTION STRENGTH: 60 Ibs WEIGHT IS ENERGY CODE LIGHTING COMPLIANCE - HANGERS: #12 AT 4'-0" AND #10 AT 5'-0" - GREATER THAN 2.5 Ibs/SF - PLUMB 1 IN 6 THEN USE 3-4 STANDARD. - CONNECTION DEVICES MIN. 100 Ibs LIGHTING AND FIXTURES: PER 2018 IECC SECTION 101.4: EXISTING ELECTRICAL POWER AND LIGHTING SYSTEMS INTERIOR LIGHTING POWER ALLOWANCES (SPACE -BY -SPACE METHOD): - PERIMETER WIRES NOT APPLICABLE WITH SUPPORT - LIGHTS < 56 Ibs - 2 ARE NOT REQUIRED TO MEET THE 2018 IECC SECTION 505 REQUIREMENTS INCLUDING WATTS/S.F. WATTS (W) LEG OF MOLDING IS 7/8" CONNECTORS 2 SLACK WIRES "LIGHTING CONTROLS" AND "INTERIOR LIGHTING POWER REQUIREMENTS". - LIGHTS > 56 Ibs TO AREA TYPE AREA S.F. ALLOWED ALLOWED PERIMETER WALL CLOSURE. STRUCTURE ANY NEW AREAS CREATED BY THE TENANT IMPROVEMENT SHALL HAVE NEW LIGHTING - MECHANICALS < 20 Ibs < 56 CONTROLS PER 2018 IECC SECTION C 405.2. ANY NEW EXIT LIGHTING SHALL BE OPEN OFFICE 4A - OPEN PLAN 481 0.81 390 CROSS RUNNERS, MAIN Ibs 2 SLACK WIRES PER 2018 IECC SECTION C405.4. ANY NEW LIGHTING SHALL BE PER 2018 IECC 3/8" OPEN OFFICE 46 -OPEN PLAN 959 0.81 777 MEETING 1 & 2 - ENCLOSED 290 0.93 270 RUNNER AND WAIL - MECHANICALS > 56 Ibs TO SECTION C405.5 AND SHALL DEMONSTRATE THAT THERE WILL BE A REMOVAL OF CLOSURE AT TERMINAL STRUCTURE EXISTING LIGHT FIXTURES AND THAT THE NEW LIGHT FIXTURES WILL NOT ADD TO THE BREAK 2 542 0.62 336 ENDS. ALL CEILING PENETRATIONS BUILDING'S LIGHTING ENERGY USAGE. CONFERENCE 4 437 1.07 468 (COLUMNS, SPRINKLERS, ETC.) AND SWITCHING REQUIREMENTS: j ELECTRICAL 90 0.43 39 INDEPENDENTLY SUPPORTED 0 FIXTURES OR SERVICES ARE ROOM SWITCH TOTAL LIGHTING POWER ALLOWED: 2,280 CONSIDERED AS PERIMETER OPEN OFFICE 4A OCCUPANT SENSING DEVICE AT CEILING* CLOSURES THAT MUST ALLOW THE OPEN OFFICE 4B OCCUPANT SENSING DEVICE AT CEILING* PROPOSED INTERIOR LIGHTING POWER USED: 3/8" SPACER BARS OR OTHER NOTED CLEARANCES BY USING MEETING 1 & 2 OCCUPANT SENSING DEVICE ON SWITCH MIN. FIXTURE FIXTURE FIXTURE NUMBER OF WATTS SUITABLE SYSTEM TO KEEP SUITABLE ESCUTCHEONS OR BREAK 2 OCCUPANT SENSING DEVICE ON SWITCH* 7/8" CLOSURE DETAILS. ID TYPE WATTAGE FIXTURES USED PERIMETER COMPONENTS CONFERENCE 4 OCCUPANT SENSING DEVICE ON SWITCH* FROM SPREADING APART. DATA OCCUPANT SENSING DEVICE ON SWITCH L1* LED 28 51 1,428 cEILING DETAIL ELECTRICAL OCCUPANT SENSING DEVICEON SWITCH* FIXTURE L1 IS BASED A FIXTURE: LIGHTING WITH 15 FT. OF AN EXTERIOR WINDOW TO . CH BUTA ING2BLT4S / 4,000K 28W. MATCH BUILDING STANDARD. SCALE (DAYLIGHT ZONE) TO BE SWITCHED SEPARATELY.4,000E PRICE SANDERS RHEES RUBY ARCHITECTS 499 MAIN STREET (208) 343-2931 BOISE, IDAHO 83702 TAOIDAHO.COM PROJECT IN TIME TEC 580 E. CORPORATE DR. SUITE 100 MERIDIAN, ID 83642 SEAL LICENSED ARCHITECT AR-2154 r STATE of DAQHO This document is the property of THE ARCHITECTS OFFICE, PLLC and is not to be duplicated without written authorization. © THE ARCHITECTS OFFICE, PLLC A LE DATE JULY 12, 2022 FILE NO. 21-505 A3.0 DRAWN MATT RHEES REVISIONS SHEET A3mO CEILING PLANS