Loading...
HomeMy WebLinkAboutA1.0 Site and Demolition Plans V1".i S 89`51'22" W 1 3.23' 0 5' 1W-0" (12) STALLS AT 9'-0" EACH = 108-0" 9'-O° 26'-0"t 20'-0" 5' FUTURE o PARKING LOT 515'-0" 52'-0" 6 -0 (5) STALLS AT 9' 0" EACH = 45'- " 9'-O° 26'-0"t 20'-0" 5' CONCRETE PATIO COMPACT STALLS d I I o PROPOSED CONCRETE °D COVERED PATIO U EXISTING PARKING LOT 20'-0" 100'-0" 12'-2"1 26'-0" 20'-0" 0 o 0 0 0 EXISTING BUILDING ro � 0 0 IEXISTING PATIO I ---- EXISTING 7 PARKING LOT do, W__ 0 EXISTING n PARKING LOT 0 N 8T31'02" E 22.85 E, C OgP00gT h 1 SITE PLAN SCALE: 1" = 204" NORTH �' PATIO A B C D E 100'-0" 25'-0" 25'-0" 25'-0" ��25'-0" l.�lol 'DEMOLITION PLAN AFm SCALE: 1/8" = V-0" KEYNOTES 1. EXISTING OCCUPIED TENANT AREA TO REMAIN. NO WORK THIS AREA U.O.N. 2. EXISTING EQUIPMENT PREVIOUSLY REMOVED. 3. EXISTING ROOF LADDER TO REMAIN. RETAIN PORTION OF PARTITION WALL FOR WALL MOUNTED LADDER. ADD ADDITIONAL FRAMING IN WALL AS REQUIRED. 4. REMOVE AND RELOCATE WALL MOUNT FIRE EXTINGUISHER. 5. REMOVE OVERHEAD DOOR. 6. REMOVE EXTERIOR DOOR AND FRAME. 7. REMOVE PORTION OF EXTERIOR WALL FOR NEW DOOR AND WINDOW SYSTEM. NOTE: VERTICAL STRUCTURAL FRAMING TO REMAIN, REMOVE NON-STRUCTURAL FRAMING ONLY. ADD ADDITIONAL FRAMING AS REQUIRED FOR NEW OPENING (KING STUDS, HEADER, ETC.). 8. REMOVE DOOR AND FRAME. SALVAGE FOR RE -USE WHERE POSSIBLE. 9. REMOVE PARTITION WALL 10. AREA OF TENANT REMODEL REMOVE ALL FINISHES AND ABANDONED EQUIPMENT. PATCH AND REPAIR EXISTING GWB AS REQUIRED. PREP FLOOR AND FOR NEW FLOOR FINISH. PREP WALLS FOR NEW PAINT AND NEW WALL BASE. 11. EXISTING DAMAGED DOOR TO BE REMOVED AND REPLACED WITH NEW TO MATCH. FRAME TO REMAIN. SALVAGE EXISTING HARDWARE WHERE POSSIBLE. GENERAL NOTES A. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES WITH THE DRAWINGS TO THE ARCHITECT PRIOR TO THE BEGINNING OF CONSTRUCTION. B. ALL INTERIOR DIMENSIONS ARE TO FACE OF GWB UNLESS OTHERWISE NOTED. FIELD VERIFY ALL CRITICAL DIMENSIONS. C. AT ANY EXISTING WALL TO REMAIN: PROTECT FROM FURTHER DAMAGE. REMOVE ANY WALL FINISHES, PATCH & REPAIR AND PREP FOR NEW FINISH. PROVIDE NEW GWB AT DAMAGED AREAS. D. CONTRACTOR TO PROVIDE TEMPORARY DUST PARTITIONS AS REQUIRED. CONTRACTOR TO MAINTAIN BUILDING IN A WEATHER -TIGHT CONDITION. E. CONTRACTOR SHALL STOCKPILE AND PROTECT ALL MULLION, GASKETS, HARDWARE, WINDOWS AND DOORS FOR REUSE, OR RETURN ALL SALVAGEABLE PARTS TO THE OWNER. F. CLEAN AND REPAIR ALL EXISTING FIXTURES, EQUIPMENT AND CABINETRY TO BE REUSED, RETURN ALL SALVAGEABLE ITEMS TO THE OWNER. G. ANY THROUGH OR MEMBRANE PENETRATION OF FIRE -RESISTIVE CONSTRUCTION TO COMPLY WITH 2O18 IBC SECTION 714. TESTED AND LISTED ASSEMBLIES TO BE PROVIDED TO FIELD INSPECTOR. H. GYPSUM BOARD MATERIALS SHALL CONFORM TO THE APPROPRIATE STANDARDS LISTED IN 2018 IBC TABLES 2506.2 AND 2018 IBC CHAPTER 35. GYPSUM BOARD MATERIALS SHALL BE ASSEMBLED AND INSTALLED IN COMPLIANCE WITH THE APPROPRIATE STANDARDS LISTED IN 2018 IBC TABLES 2508.1 AND 2018 IBC CHAPTER 35. I. INSULATING MATERIALS, WHERE CONCEALED AS INSTALLED IN BUILDINGS OF ANY TYPE OF CONSTRUCTION, SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE —DEVELOPED INDEX OF NOT MORE THAN 450 AS DETERMINED BY ASTM E 84. J. WITHIN THIS TENANT SPACE, THE WALL AND CEILING FINISHES OF ROOMS SHALL HAVE A FLAME SPREAD OF 200 MAXIMUM AND A SMOKE —DEVELOPED INDEX OF 450 MAXIMUM AS ESTABLISHED BY ASTM E 84. K. EXIT DOORS TO BE OPENABLE FROM INSIDE WITHOUT A KEY OR SPECIAL KNOWLEDGE. SEE 2018 IBC SECTION 1010.1.9.4 FOR ANY EXCEPTIONS. L CONTRACTOR TO COORDINATE WITH OWNER FOR LOCATION OF ALL SPECIAL EQUIPMENT AND SPECIAL POWER REQUIREMENTS. M. ALL NEW AND EXISTING FIXTURES AND EQUIPMENT TO BE INSTALLED OR REINSTALLED ARE TO BE IN ACCORDANCE WITH THE MANUFACTURERS REQUIREMENT, ACCEPTED BUILDING STANDARDS AND CONFORM TO ALL BUILDING CODES. LEGEND EXISTING CONCRETE MASONRY UNIT (CMU) WALL CONSTRUCTION TO REMAIN. 77777TT EXISTING CONSTRUCTION TO REMAIN. EXISTING FF&E TO BE REMOVED BY TENANT. EXISTING CONSTRUCTION TO BE REMOVED. EXISTING OR NEW CONSTRUCTION ABOVE OR BELOW THE FLOOR PLAN. FORMER TENANT DEMISING WALL. / NO WORK THIS AREA U.O.N. TJ6 PRICE SANDERS RNEES RUBY THE ARCHITECTS OFFICE 499 MAIN STREET (208) 343-2931 BOISE, IDAHO 83702 TAOIDAHO.COM PROJECT IN TIME TEC 580 E. CORPORATE DR. SUITE 100 MERIDIAN, ID 83642 SEAL LICENSED ARCHREDT AR-2154 F Matlhew J. Rhees srwrE of IDAHO This document is the property of THE ARCHITECTS OFFICE, PLLC and is not to be duplicated without written authorization. © THE ARCHITECTS OFFICE, PLLC FILE DATE JULY 12, 2022 FILE NO. 21-505 A1.0 DRAWN MATT RHEES REVISIONS SHEET Al X DEMOLITION PLAN