Loading...
HomeMy WebLinkAboutCivilPlan2 V1APPROVED os os 22 ----------------------- C h i n d e n B I v d GRADING LEGEND --------5460-------- EXISTING MAJOR CONTOUR 52 EXISTING MINOR CONTOUR 5465 PROPOSED MAJOR CONTOUR 66 PROPOSED MINOR CONTOUR PROPOSED GRADE BREAK 59 15.00 PROPOSED SPOT ELEVATION 15.00 FF FINISHED FLOOR 15.00 FL FLOWLIINE 15.00 GB GRADE BREAK 15.00 ME MATCH EXISTING ® 15.00 SW SIDEWALK N15.00 15.00 fG FINISHED GRADE TR TOP Of RAMP 15.00 BR BOTTOM OF RAMP 0 10 20 SCALE: 1"=20' 58 ----------------------1 58 59 - - 1 _ I 59.21 SW 59.31 SW Q 59 ---------------------------------------------------------------------------------------------� 59 58 55.85 SW 58 57 - 58.53 SW 55 85 SW 58.53 SW 58.30 BW 1 56 _ 58.95 TW 55.90 BW 55.46 FL 58.95 TW 55.41 FL 55.:Oa 55.96 FL 56.05 FL � 54.92 TG , 55.5E FL STM-1 � 55.64 fL Sg SINGLE CURB INLET (24" X 35.5") ssst FL ss.71 FL �I 56.16 FL 2554.92 55.67 FL 5s.23 FL XRIM= 55.27 FL s r' 55.60 FL i 55.87 FL 56.14 FL 56.08 FL m rn 56 _ (P 55.48 FL 3 S6.21 FL v, 55.44 FL 55.20 R 9 56.29 BR STM-3 J - 56.21 BR 4" CLEANOUT m 56.27 FL = 56.71 TR CONNECT TO ROOF DRAIN � 2.00% 5s.7s TR 1.50% 56.91 SW 2.26% RIM= 25a5.89 'N I� 4" HDPE-5.54 LF 0 7.78% STM-4 o to V VVVV 4" CLEANOUT ,367 2.os% CONNECT TO ROOF DRAIN RIM= 2556.95 aj 5e s4s8 TG 4, HDPE-18.04 LF 0 7.78% .... STM-6 STM-2 5ss7 sw O`' SINGLE CURB INLET (24" X 35.5") RIM= 2552.00 1 56.55 FL 56.15 FL RIM= 2554.68 . 56.97 SW 56.06 FL LOST RAPIDS 57,92 TW ss.5a ce PROPOSED 56.46 GB 56.00 FL DEVELOPMENT II LLC 57.00 BW fn 0.50% o STRUCTURE 56.34 GB 3.00% 56.26 FL 56.02 FL PARCEL• 5330760600 56.38 GB 56.50 GB 3,103 SF - 56.38 GB . FF=2557.00 a` 1.67% 00 0` 55.94 FG 55.13 FL 54.89 FL 10" HDPE-40.78 LF 05 96% = 55.25 FL 67% I -.1 1 71% 55.27 FL 4" HDPE-17.34 LF 0 14.34% STM-12- _ -_: I 55.15 FL moo° 55.58 FG 54.75 FL NULL STRUCTURE { O� o' STM-11 :j. RIM= 2551.20 A 1.42% 4' CLEANOUT 55.94 FG o CONNECT TO ROOF DRAIN 56.33 FL RIM = 2556.93 �tio 2'11% STM-7 10" HDPE-61.65 LF 0 1.96% SINGLE CURB INLET (24" X 35.5") �o ® ® RIM= 2555.88 5 .26 fL 56.78 SW 0,00% 56.83 SW 1,50% 56.83 SW 0 56.83 SW s6 _56.24 56.74 SW 56.24 FL rn FL ® O ® I B 51 56.18 FL 56.00 FL 56 56.03 FL 6 55.93 FSTM-14 55.99 FIL O MH-ECCENTRIC (4' 0) 55.98 FL 56.02 FL 55st FL _ RIM- 2555.7Y 1 1.09% 10" HDPE-48.59 LF 0 5.54% STM-10 MH-ECCENTRIC (4' 0) RIM= 2555.31 O O 55.47FL 55.49FL I > -_-_-____ 55.24 FL - -/O'• 55.40 FL 55.42 FL 55.74 FL 55.83 FL 56.23 FG ti STM-13 Oo� 10" HDPE-25.23 LF 0 15.65% ■ 55.12 FL MH-ECCENTRIC (4' 0) STM 5 RIM= 2555.55 ��� 5 55.87 SW .86 SW 0��° , 55.97 FL SINGLE CURB INLET (24" X 35.5") ®vy 55.16 FL 55.96 FL RIM= 2554.82 54.82 TG 55.16 FL 9�09 55.18 TG 55.53 FL _ ME 55.9s sW STM-9 56.02 SW SINGLE CURB INLET (24" X 35.5") STM-8 RIM= 2555.89 SINGLE CURB INLET (24" X 35.5") ti55 RIM= 2555.18 10" HDPE-20.30 LF 0 9.10% U COSTCO WHOLESALE CORP PARCEL- 5330760300 SITE LEGEND PROPERTY BOUNDARY LINE RIGHT OF WAY BOUNDARY LINE EXISTING EASEMENT UNE SETBACK UNE EXISTING TO REMAIN PROPOSED NEW FUTURE NEW EXISTING SIGN EXISTING UTILITY STUB MARKER EXISTING PAD MOUNTED TRANSFORMER ' EXISTING LIGHT POLE EXISTING SANITARY SEWER MANHOLE EXISTING STORM DRAIN MANHOLE EXISTING STORM DRAIN INLET EXISTING WATER METER EXISTING WATER VALVE EXISTING IRRIGATION VALVE EXISTING CURB AND GUTTER OO ® PROPOSED SANITARY SEWER STRUCTURE ® PROPOSED STORM DRAIN STRUCTURE ® PROPOSED STORM DRAIN CATCH BASIN -SD PROPOSED STORM DRAIN T PROPOSED SIGN ® PROPOSED ADA PARKING SYMBOL ,m PROPOSED BIKE RACK PROPOSED CURB AND GUTTER PROPOSED RETAINING WALL 56.96 SW 56.56 FG 156.99 SW 1 56.08 FL I I 56.13 EOC 56.00 FL I 1 55.97 FL 56.98 TR ® o Sfi.46 F® I I O� 55.96 FL I I s� 56.96 TR I 55.95 FL 56.00 EOC I s�9 I 56.46 FL \ h� 56.49 BR I56.46 BR o I 56.53 FG ,v�� 55.96 EOC 2.25% I 56.05 EOC o' I I 56.49 BR 56.46 FL I 56.00 EOC 55.97 EOC 56.46 BR 55.95 FL o 55.87 FL 55.94 FL I56.46 FL I 55.85 FL 55.97 EOC s 56 I 55,92 FL 55.96 EOC 55.97 EOC I 56.96 TR I 56.99 TR I 55.91 EOC 55.93 EOC L - - - - 55.90 EOC 55.93 EOC � 56.00 EOC 55.98 EOC O RAMP DETAIL O TRASH ENCLOSURE DETAIL SCALE: 1" = 10' SCALE: 1" = 10' Gall"ilowayIII 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 GallowayUS.com COPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. U) O 0 C 4LU m Z � W 0 0 0 0 O = z 0 0 z W W Q J O W CO W 2E M # Date Issue / Description Init. 1 4120/22 1st CUP Submittal DJS GRADING NOTES _ 1. REQUIREMENTS SHOWN ON SITE PLAN SHALL GOVERN. DRAWINGS AND SPECIFICATIONS SHOWING OTHERWISE NOThWTHSTANDING. CONTRACTOR TO POINT OUT ANY DISCREPANCIES TO - THE ENGINEER OF RECORD PRIOR TO BID. - 2. NO WORK IS TO BEGIN UNTIL ALL PERMITS HAVE BEEN OBTAINED. CONTRACTOR MUST HAVE - COPIES OF ALL STATE AND LOCAL STORMWATER DISCHARGE AND EROSION CONTROL PERMITS ON SITE PRIOR TO ANY DISTURBANCE AND/OR GRADING ACTIVITY. - 4. THIS DESIGN IS BASED ON A SOIL AND FOUNDATION INVESTIGATION. A COPY OF THIS - REPORT IS AVAILABLE FOR INSPECTION BY THE CONTRACTOR. - 5. ALL LANDSCAPING AREAS SHALL BE GRADED WITHIN 0.10' OF DESIGN WITH APPROVED TOP SOIL TO A MINIMUM DEPTH AS SPECIFIED BY THE LANDSCAPE ARCHITECT AND CITY SPECIFICATIONS. 6. ALL SPOT GRADES SHOWN ARE TO FLOWLINE UNLESS OTHERWISE NOTED. 7. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR MINIMIZING DEPOSITION OF ONSITE Project No: SEDIMENTS ONTO SURROUNDING PUBLIC STREETS DURING CONSTRUCTION, REFER TO EROSION Drawn By: KSB CONTROL PLANS AND DETAILS FOR INFORMATION. Checked By: DJS 8. GENERAL CONTRACTOR SHALL PROVIDE BARRICADE PROTECTION AS REQUIRED BY THE CITY CAUTION -NOTICE TO CONTRACTOR AROUND ALL FOOTINGS, EXCAVATIONS AND ALL OFFSITE WORK. Date: 2022.04.14 1. ALL UTIUTY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED 9. THE PROPOSED STORM SEWER SYSTEM ON -SITE IS PRIVATELY OWNED AND MAINTAINED. BY THE APPROPRIATE UTIUTY COMPANY AND FIELD SURFACE 0 EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN 0 GRADING PLAN 10. ANY FILL MATERIAL REQUIRED TO BRING THE SITE TO GRADE SHALL BE CLEAN FILL DIRT APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S APPROVED BY GEOTECHNICAL ENGINEER AND SHALL BE PLACED AND COMPACTED PER RESPONSIBILITY To FIELD VERIFY THE LOCATION OF ALL UTILITIES, GEOTECHNICAL REPORT RECOMMENDATIONS. PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIESTO THE KnowwhaYsbelOw. 11. TOP OF GRATE (TOG) AND FLOWLINE (FL) SPOT GRADES AT INLETS DO NOT INCLUDE GUTTER ENGINEER PRIOR TO CONSTRUCTION. Call before you dig. DEPRESSION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. C2.0