Loading...
HomeMy WebLinkAboutACHD Commentsa~ - ~ ~ ~~~~ ~. ___ --- C H D (/Of11.-11M1~~0 Sfi~iV'LGG March 2$, 2006 To: Sea 2 Sea LLC 757 W. Bankside Drive Eagle, Idaho 83616 Subject: Knight Sky Estates/MPP-06-004/MAZ-06-005 Knighthill Center/MPP-06-005/MAZ-06-006 John 5. Franden, President Carol A. McKee, 1st Vice President Dave Bivens, 2nd Vice President Sherry R. Huber, Commissioner Rebecca W. Arnold, Commissioner j~,ECEIVED MAY 1 Z 2006 GITY OF MERIDIAN CITY CLERK OF~IrF On March 22, 2006, the Ada County Highway District Commission acted on your applications for the above referenced projects. The attached report lists site-specific requirements, conditions of approval and street improvements, which are required. If you have any questions, please feel free to contact me at 208-387-6171. Sincerely, Lori Den Hartog Planning Review Supervisor Right-of-way 8~ Development Services, Planning Division CC: Project file, Utilities City of Meridian SLN Planning, Inc. 839 E. Winding Creek Drive, Suite 201 Eagle, Idaho 83616 ~~a3 ~~y~~s~y c~~ Ada County Highway District • 3775 Adams Street • Garden City, TD • 83714 • PH 208-387-6100 • FX 345-7650 • www.achd.ada.id.us ~~ t ~~~~~ CHD ~~~x~ :w Project/File: Lead Agency: Site address: Commission Approval: Right-of--Way & Development Department Planning Review Division Knight Sky Estates/MPP-06-004IMAZ-06-005 City of Meridian n/w/c Linder Road and Chinden Boulevard (US 20/26) March 22, 2006 at 6:30 p.m. Applicant: Sea 2 Sea, LLC 757 W. Bankside Drive Eagle, Idaho 83616 Representative: SLN Planning, Inc. 839 E. Winding Creek Dr., Ste. 201 Eagle, ID 83616 Staff Contact: Lori Den Hartog Phone: 3$7-6171 E-mail: Idenharto achd.ada.id.us Tech Review: March 10, 2006 Application Information: Acreage: 5$.56 Current Zoning: RR Proposed Zoning: R-4 (32.86-acres), TN-C (14.54 acres) and C -C (11.16-acres) Residential lots: 126 lots (24 townhouses and 102 detached single-family lots) Commercial lots: 7 Common Lots: 26 1 Knight Sky Estates! MPP-06-004/MAZ-06-005 T_~ ~ ~ • ~ A. Findin s of Fact Existing Conditions Site Information: The site is currently used for agricultural purposes. 2. Description of Adjacent Surroundin Area: Direction Land Use Zonin North Lar a-lot Residential RR South Proposed Knight Hill Commercial Center & Residential Proposed C-G & R-4 Lochsa Falls Subdivision East Linder Road & a ricultural east of Linder Road RUT West Spurwing Golf Course RR 3. Existing Roadway Improvements and Right-of-Way Adjacent To and Near the Site • Linder Road is currently improved with 2 traffic lanes, and no curb gutter or sidewalk abutting the site. There is 50-feet of right-of-way existing for Linder Road (25-feet from centerline). • Chinden Boulevard (US 20/26) is currently improved with 2 traffic lanes, and no curb, gutter or sidewalk abutting the site; east of Linder, Chinden has tyvo traffic lanes and a center turn lane. There is approximately 80-feet of right-of-way existing for Chinden Boulevard. Chinden Boulevard is under the jurisdiction of the Idaho Transportation Department 4. Existing Access: There are two existing gravel driveways on Linder Road to the site, and no defined access to Chinden Boulevard (US 20/26). 5. Site History: This site was platted in 1991 as one of the open space lots within anon- Farm subdivision, Brandt Subdivision. Development Impacts 6. Trip Generation: This development is estimated to generate 3,858 additional vehicle trips per day based on the submitted traffic impact study. 7. Impact Fees: There will be an impact fee that is assessed and due prior to issuance of any building permits. The assessed impact fee will be based on the impact fee ordinance that is in effect at that time. 8. Traffic Impact Study: A traffic impact study was required with this application. Below are the principal conclusions of the submitted TIS prepared by Washington Group International. • The proposed development is project to generate an average daily traffic (ADT) volume of 3,858 vehicles of which the a.m. peak hour traffic is 209 vehicles per hour (vph) and the p.m. peak hour traft'ic is 363 vph. • As a result of the site build-out, traffic on the roadways in the project vicinity are expected to increase. Traffic on Chinden Boulevard may increase by 390 vpd west of Linder Raad and 1,930 vpd east. Traffic on Linder Road may increase by 390 vpd north and 1,160 vpd south of Chinden Blvd., respectively. Traffic on Meridian Road may increase 40 vpd north and 200 vpd south of Chinden Blvd., respectively. • The intersection of Linder Road and Chinden Boulevard is signalized with a single thru/right lane and separate left turn bay an each leg. The intersection currently operates at level of service (LOS) E in both the a.m. and p.m. peak hours. Far the 2011 Background condition, the intersection is forecast to operate at LOS F in both the a.m. and p.m. peak hours. Improvements to the intersection are needed to accommodate the Background traffic volumes. 2 Knight Sky Estates! MPP-06-004/MAZ-O6-005 • With improvements, the Linder Road/Chinden Blvd. intersection is forecast to operate at LOS E in both the a.m. and p.m. peak hours far the 2011 Background and Build Out conditions. No additional improvements are needed to accommodate the Build Out condition. • The intersection of Meridian Road and Chinden Boulevard is signalized with a single thru/right lane and separate left turn bay on each leg. The intersection currently operates at LO5 C in both the a.m. and p.m. peak hours. For the 2011 Background condition, the intersection is forecast to operate at LOS E in both the a.m. and p.m. peak hours. For the 2011 Build Out condition, the intersection is forecast to operate at LOS E in both the a.m. and p.m. peak hours. No improvements are needed to accommodate the Build out condition. • The site approach with Linder Road was assumed to be two-way STOP controlled on the minor approaches. For the 2011 Build Out condition, the intersection is forecast to operate at LOS B in the a.m. peak hour and LOS C in the p.m. peak hour. A left turn bay and improved curb radii are warranted at the site. • The site approach with Chinden Boulevard is signalized with one thru/right turn lane and a separate left turn bay on each leg. For the 2011 Build Out condition, the intersection is forecast to operate at LOS D in the a.m. peak hour and LOS B in the p.m. peak hour. No Improvements are needed to accommodate the Build Out condition. • The average daily traffic (ADT) volumes for both Linder Road and Meridian Road are below COMPASS thresholds. • The average daily traffic (ADT) volumes for Chinden Boulevard meet or exceed COMPASS thresholds for the Background condition. Capacity improvements to Chinden Blvd. are needed for the Background conditions. • ITD is currently studying Chinden Boulevard (US 20/26). If widened to a five lane section, the roadway will have adequate capacity for the Build Out condition. • The internal site roadways meet local requirements for a maximum of 1,000 vpd on local roads with front-on housing. TIS Recommendations: • A second eastlwest bound thru lane should be added to the Linder Road/Chinden Blvd. intersection. (This recommendation was also part of the Lochsa Subdivision Traffic Impact Study). • The Linder Road site approach warrants a left turn bay on Linder Road for vehicles entering the site. The curb radii should be 30 feet or greater to accommodate right turning traffic. • Additional lanes are needed to increase capacity along Chinden Boulevard. A five-lane section would have enough capacity to accommodate the Build Out traffic volumes. 9. Impacted Roadways: Roadway Frontage Functional Traffic Count Level of Speed Classification Service* Limit Linder Road 550' Minor Arterial 9,854 north of Chinden on Better 50 MPH 4/19/05 than "C" 6,437 south of Chinden on 4/21 /04 Chinden 2,500' Principal 17,426 west of Linder on "E" 55 MPH Arterial 4/19/05 19,592 east of Linder on 6/8/05 *Acceptable level of serv ice for atwo-lane minor arterial roadway is "D" (14,000 VTD ). *Acceptable level of serv ice for a three lane principal arterial roadway is "E" (18,500 VTD). 3 Knight Sky Estates/ MPP-06-004/MAZ-06-005 ,. • • 10. Capital Improvements Plan/Five Year Work Program The intersection of Linder Road and Chinden Boulevard is identified in the current Capital Improvements Plan to be widened. The ongoing update for the CIP proposes that Linder Road be widened to a 5-lane arterial roadway standard from Floating Feather to Overland Road. 11. Neighborhood Concerns District staff has been contacted by a few surrounding property owners that have concerns related to the development of this site. The concerns include the proposed local street intersection with Linder Road, the current traffic volumes on Linder Road, the current traffic volumes at the intersection of Linder Road and Chinden Boulevard, and the internal location of the local/commercial frontage street. B. Findin s for Consideration 1. Linder Road Right-of--Way Policy: District policy requires 96-feet of right-of-way on arterial roadways (Figure 72-F1 B). This right-of--way allows for the construction of a 5-lane roadway with curb, gutter, 5-foot concrete detached sidewalks and bike lanes. Sidewalk Policy: District policy requires 7-foot wide attached (or 5-foot detached) concrete sidewalk on all collector roadways and arterial roadways (7204.7.2). Staff Comment/Recommendation: In order to accommodate a 5-lane roadway section on Linder Road and an additional right-turn lane at the intersection of Linder Road and Chinden Boulevard, the District will require a total of 60-feet of right-of-way be dedicated abutting the site along Linder Road. Dedicate a total of 60-feet of right-of-way from the centerline of Linder Road abutting the parcel by means of a warranty deed. The right-of-way purchase and sale agreement and deed must be completed and signed by the applicant prior to scheduling the final plat far signature by the ACRD Commission or prior to issuance of a building permit (or other required permits), whichever occurs first. Allow up to 30 business days to process the right-of-way dedication after receipt of all requested material. The owner will be paid the fair market value of the right-of-way dedicated which is an addition to existing ACRD right-of-way. The applicant will also be required to construct a 5-foot detached concrete sidewalk abutting the site. The sidewalk should be located a minimum of 53-feet from the centerline of Linder Road. The applicant will be required to construct a left turn bay on Linder Road for vehicles entering the site at Knights Park Drive, in accordance with the submitted Traffic Impact Study. The curb radii should be 30 feet or greater to accommodate right turning traffic at the site entrance. 2. Chinden Boulevard Chinden Boulevard is under the jurisdiction of the Idaho Transportation Department. The applicant has coordinated with ITD in relation to the right-of-way proposed to be preserved (100-feet from centerline) and the proposed access point. The applicant has proposed access at the half-mile in alignment with Long Lake and the signal that was installed with Lochsa Falls Subdivision. Chinden Boulevard is a Type IV access controlled highway with access points allowed at the half-mile. All signal modifications including relocation of utilities and irrigation at the intersection of Long Lake Way and Chinden Boulevard, will be the responsibility of this applicant. 4 Knight Sky Estates! MPP-06-004/MAZ-06-005 3. Internal Commercial Streets Right-of-Way Policy: District policy requires 54-feet of right-of-way on industrial/commercial roadways (Figure 72-F18). This right-of-way allows for the construction of a 3-lane roadway with curb, gutter and 5-foot wide concrete sidewalks. Section Policy: District policy 7202.8 and 72-F1A, requires roadways abutting commercial developments to be constructed as a 40-foot street section with curb, gutter and 5-foot concrete sidewalk within 54-feet of right-of-way. Island Policy: District policy 7202.7 and 7207.5 require islands to be constructed a minimum of 4- feet wide with a minimum area of 100-square feet and designed to safely channel traffic. The roadway on either side of the traffic island should maintain a minimum of a 21-foot street section. District policy also requires any proposed landscape islands/medians within the public right-of-way dedicated by this plat should be owned and maintained by a homeowners association. Notes of this should be required on the final plat. The design should be reviewed and approved by ACHD's Development staff. Tree Planter Width Policy: The applicant should also comply with the District's Tree Planter Width Interim Palicy which prohibits all trees in planters less than 6-feet in width. In addition to prohibiting trees in planters less than 6-feet in width, the policy requires a minimum planter width of 6-feet for class II tress with the installation of root barriers on both sides of the planter strip or a minimum planter width of 8-feet without the installation of a root barrier. The policy also requires Class I and Class III trees to provide a minimum planter width of 10-feet. Applicant Proposal: The applicant has proposed to construct a commercial street that parallels Chinden Boulevard as a frontage road to serve the commercial lots and the townhouse lots within this development. The street, Knights Park Drive, is proposed to be constructed as a boulevard style with center landscaped medians. The applicant is proposing a 40-foot street section where there are no islands, and 21-foot street sections on either side of the islands where they are located in the center of the street. The applicant is proposing vertical curb, gutter, and 5-foot detached sidewalks along this boulevard style roadway. Staff Comment/Recommendation: The applicant's proposal meets District policy and should be approved with this application. 4. Internal Residential Streets Right-of-way: District policy 7204.4.1 and Figure 72-F1A requires 50-feet of right-of-way on local streets. This right-of-way allows for the construction of a 2-lane roadway with curb, gutter and 5-foot wide concrete sidewalks. Street Section: District policy 72-F1A, allows local residential public roads with a 33-foot street section with parking on both sides of the roadway, if the amount of vehicle trips per day on the street does not exceed 1,000 and the appropriate 1•ire department reviews and approves the street section. The proposed density of development that will utilize the internal local residential streets is anticipated to generate less than 1,000 vehicle trips per day. Applicant Proposal: The applicant has proposed 33-foot street sections with rolled curb, gutter, and 5-foot concrete sidewalks throughout the residential areas of the development. Staff CommentlRecommendation: The applicant's proposal meets District policy. The reduced street section requires Fire Department approval and typically the Meridian Fire Department prefers a 34-foot street section, rather than the 33-foot street section. 5 Knight Sky Estates/ MPP-06-004/MAZ-06-005 5. Private Streets Policy: District policy 7205.6, other jurisdictions in Ada County establish the requirements for private streets. The District retains authority and will review the proposed intersection of a private and public street for compliance with District intersection policies and standards. Applicant Proposal: The applicant is proposing to construct private streets, that intersect the main commercial street, to serve the proposed townhouses. Staff CommentlRecommendation: The City of Meridian and the Meridian Fire Department will review and approve the design of the proposed private streets. The proposed locations of the private streets meet District offset policy. 6. Stub Streets Stub Street Policy: District policy 7203.5.1 states that the street design in a proposed development shall cause no undue hardship to adjoining property. An adequate and convenient access to adjoining property for use in future development may be required. If a street ends at the development boundary, it shall meet the requirements of sub section 7205, "non-continuous streets." District policy 7205.5 states that stub streets will be required to provide intro-neighborhood circulation or to provide access to adjoining properties. Stub streets will conform with the requirements described in Section 7204.5, 7204.6 and 7204.7, except a temporary cul-de-sac will not be required if the stub street has a length no greater than 150-feet. A sign shall be installed at the terminus of the stub street stating that, "THIS ROAD WILL BE EXTENDED IN THE FUTURE." In addition, a stub street must meet the following conditions: 1. A stub street shall be designed to slope towards the street intersection and drain surface water toward that intersection, unless a satisfactory storm drain system is installed. 2. The District may require appropriate covenants guaranteeing that the stub street will remain free of obstructions. Applicant Proposal: The applicant has not proposed to construct any stub streets to the surrounding properties. Staff Comment/Recommendation: In review of the site layout, District staff is recommending that the applicant construct a local stub street to the 2.99-acre out-parcel located at the northwest corner of the development. This parcel is currently undeveloped. District staff also recommends that a stub street be constructed to the Spurwing property to the west. This stub street should intersect the entrance road, Long Lake Way, without changing the current configuration of that entrance road (see attached sketch). This requirement would provide for the possibility of the Spurwing development to have access to the half-mile signal on Chinden Boulevard if the roadways are connected in the future. In addition, if the Spurwing development ties into this development in the future, there is the possibility of closing the existing Spurwing access on Chinden Boulevard which is located approximately 600-feet west of the half-mile signal. District staff is not recommending that a stub street be constructed to the north property line due to the anticipated development pattern. The properties adjacent to the north are located within the Impact Area for the City of Eagle and are anticipated to be developed with densities of 1 unit per 2 acres. Currently the properties to the north are 5-acre parcels. With the zoning in effect through the City of Eagle, these properties would only be able to subdivide one time. The District does not anticipate being able to have a nexus for requiring the extension of a full public street for one additional lot, if the properties to the north re-develop. g Knight Sky Estates/ MPP-06-004/MAZ-Ofi-005 ~~ 7. Roadway Offsets Roadway Offset Policy; District policy 7204.11.6, requires local roadways to align or offset a minimum of 300-feet from an arterial roadway (measured centerline to centerline). District policy 7204.11.6, requires local roadways to align or offset a minimum of 125-feet from another local roadway (measured centerline to centerline). Applicant Proposal: The applicant is proposing to construct the entrance road on Linder Road, Knights Park Drive, approximately 550-feet north of Chinden Boulevard (centerline to centerline). The internal residential roadways are proposed to meet District offset policy. Staff Comment/Recommendation: The applicant's proposal meets District offset policy. The applicant has proposed the internal commercial street to intersect Linder Road at the site's furthest north property line. 8. Driveways Offset Policy: District policy 72-F4 (1) and 72-F4 (2), requires driveways located on commercial/industrial roadways to offset a controlled and/or uncontrolled intersection a minimum of 50-feet (measured near edge to near edge). Width Policy: District policy 7207.9.3 restricts commercial driveways with daily traffic volumes aver 1,000 vehicles to a maximum width of 36-feet. Curb return type driveways with 15-foot radii will be required for driveways accessing collector and arterial roadways. Paving Policy: Graveled driveways abutting public streets create maintenance problems due to gravel being tracked onto the roadway. In accordance with District policy, 7207.9.1, the applicant should be required to pave the driveway its full width and at least 30-feet into the site beyond the edge of pavement of the roadway and install pavement tapers with 15-foot radii abutting the existing roadway edge. Applicant Proposal: The applicant is proposing to locate the commercial driveways along Knights Park Drive, at the shared property lines of the commercial lots. The driveways are spaced more than 300-feet apart. The driveways are proposed to be 40-feet wide. Staff CommentlRecommendation: The proposed locations of the commercial driveways meet District policy and should be approved as proposed. The driveways will be restricted to a maximum of 36-feet in width. 9. Turnarounds Policy: District policy 7205.2.1 requires turnarounds to be constructed to provide a minimum turning radius of 45-feet. The applicant should also be required to provide a minimum of a 29-foot street section on either side of any proposed center islands within the turnarounds. The medians should be constructed a minimum of 4-feet wide to total a minimum of a 100-square foot area. Applicant Proposal: The applicant has proposed to construct the cul-de-sac turnarounds with center islands and parking spaces within the islands. Staff Comment/Recommendation: The applicant shall coordinate the proposed parking within the cul-de-sac turnarounds with District Development Review staff. 7 Knight Sky Estates/ MPP-06-004/MAZ-O6-005 10. Unopened Right-of-Way/Easement Policy: District policy 7203.4.2 states that if a proposed development abuts an unpaved street or streets, the developer shall canstruct full one-half street improvements, including curb, gutter, and sidewalk, plus additional pavement widening beyond the centerline established for the street to provide a minimum 24-foot wide paved surface. Staff Comment/Recommendation: There is a 25-foot roadway easement along the site's north property line identified on the original subdivision plat, Brandt Subdivision. The applicant will be required to vacate or exchange the un-opened roadway easement through a separate public hearing process. 11. Other Access Linder Road is classified as a minor arterial roadway. Other than the access specifically approved with this application, direct lot access is prohibited to this roadway and should be noted on the final plat. C. Site Specific Conditions of Approval 1. Dedicate a total of 60-feet of right-of-way from the centerline of Linder Road abutting the parcel by means of a warranty deed. The right-of-way purchase and sale agreement and deed must be completed and signed by the applicant prior to scheduling the final plat far signature by the ACHD Commission or prior to issuance of a building permit (or other required permits), whichever occurs first. Allow up to 30 business days to process the right-of-way dedication after receipt of all requested material. The owner will be paid the fair market value of the right-of-way dedicated which is an addition to existing ACRD right-of-way. NOTE: The right-of-way will taper beyond the intersection to the north. The applicant shall coordinate the taper length and total right-of-way needs with Development Review staff. 2. Construct a 5-foot detached concrete sidewalk abutting the site on Linder Road located a minimum of 53-feet from the centerline of the roadway. 3. Comply with the requirements of the Idaho Transportation Department for right-of-way, access, and improvements to Chinden Boulevard (US 20/26). All signal modifications including relocation of utilities and irrigation at the intersection of Long Lake Way and Chinden Boulevard, will be the responsibility of this applicant. 4. Construct Knights Park Drive, the frontage road paralleling Chinden Boulevard, as a 40-foot commercial street section with vertical curb, gutter, and 5-foot detached sidewalks. Provide a minimum 21-foot street section on each side of the proposed center islands. Any landscape islands/medians within the public right-of-way dedicated by this plat shall be owned and maintained by a homeowners association. Notes of this are required on the final plat. The design should be reviewed and approved by ACHD's Development staff. 5. Construct the internal residential roadways as 33-foot street sections (or 34-feet if required by the Meridian Fire Department) with rolled curb, gutter, and 5-foot concrete sidewalks. The applicant shall obtain Fire Department approval for the reduced street width. 6. canstruct the proposed private streets in accordance with the standards set forth by the City of Meridian. The private streets shall be required to meet the minimum offset standard of 125-feet centerline to centerline at their intersections with the public street system. 8 Knight Sky Estates/ MPP-06-004/MAZ-06-005 7. Construct a local stub street to the 2.99-acre out-parcel that is currently undeveloped and is located at the northwest corner of the development. Install a sign at the terminus of the stub street stating that, "THIS ROAD WILL BE EXTENDED IN THE FUTURE." 8. Construct a stub street to the Spurwing property to the west. This stub street shoal) intersect the entrance road, Long Lake Way, without changing the current configuration of that entrance road (see attached sketch). 9. Construct the entrance road on Linder Road, Knights Park Drive, approximately 550-feet north of Chinden Boulevard (centerline to centerline). Construct a left turn bay on Linder Road for vehicles entering the site at Knights Park Drive, in accordance with the submitted Traffic Impact Study. The curb radii shall be 30 feet or greater to accommodate right turning traffic at the site entrance. 10. Locate the commercial driveways along Knights Park Drive, at the shared property lines of the commercial lots, as proposed. The driveways are restricted to a maximum width of 36-feet. 11. Construct the residential turnarounds to provide a minimum turning radius of 45-feet. Provide a minimum of a 29-foot street section on either side of any proposed center islands within the turnarounds. The medians shall be constructed a minimum of 4-feet wide to total a minimum of a 100-square foot area. The applicant shall coordinate with District Development Review and Traffic Services staff on the design of the parking within the center islands within the turnarounds. 12. Vacate or exchange the 25-foot wide un-opened roadway easement along the site's north property line through a separate public hearing process. 13. Other than the access specifically approved with this application, direct lot access is prohibited to Linder Road and shall be noted on the final plat. 14. Comply with all Standard Conditions of Approval. D, Standard Conditions of A royal 1. Any existing irrigation facilities shall be relocated outside of the right-of-way. 2. Private sewer or water systems are prohibited from being located within any ACHD roadway or right-of-way. 3. All utility relocation costs associated with improving street frontages abutting the site shall be borne by the developer. 4. Replace any existing damaged curb, gutter and sidewalk and any that may be damaged during the construction of the proposed development. Contact Construction Services at 3$7-6280 (with file number) for details. 5. Comply with the District's Tree Planter Width Interim Policy. 6. Utility street cuts in pavement less than five years old are not allowed unless approved in writing by the District. Contact the District's Utility Coordinator at 387-6258 (with file numbers) for details. 7. All design and construction shall be in accordance with the Ada County Highway District Policy Manual, ISPWC Standards and approved supplements, Construction Services procedures and all g Knight Sky Estates/ MPP-06-004/MAZ-06-005 applicable ACHD Ordinances unless specifically waived herein. An engineer registered in the State of Idaho shall prepare and certify all improvement plans. 8. The applicant shall submit revised plans for staff approval, prior to issuance of building permit (or other required permits), which incorporates any required design changes. 9. Construction, use and property development shall be in conformance with all applicable requirements of the Ada County Highway District prior to District approval far occupancy. 10. Payment of applicable road impact fees are required prior to building construction in accordance with Ordinance #200, also known as Ada County Highway District Road Impact Fee Ordinance. 11. It is the responsibility of the applicant to verify all existing utilities within the right-of-way. The applicant at no cost to ACHD shall repair existing utilities damaged by the applicant. The applicant shall be required to call DIGLINE (1-800-342-1585) at least two full business days prior to breaking ground within ACRD right-of-way. The applicant shall contact ACHD Traffic Operations 387-6190 in the event any ACRD conduits (spare or filled) are compromised during any phase of construction. 12. No change in the terms and conditions of this approval shall be valid unless they are in writing and signed by the applicant or the applicant's authorized representative and an authorized representative of the Ada County Highway District. The burden shall be upon the applicant to obtain written confirmation of any change from the Ada County Highway District. 13. Any change by the applicant in the planned use of the property which is the subject of this application, shall require the applicant to comply with all rules, regulations, ordinances, plans, or other regulatory and legal restrictions in force at the time the applicant or its successors in interest advises the Highway District of its intent to change the planned use of the subject property unless a waiver/variance of said requirements or other legal relief is granted pursuant to the law in effect at the time the change in use is sought. E. Conclusions of Law The proposed site plan is approved, if all of the Site Specific and Standard Conditions of Approval are satisfied. 2. ACRD requirements are intended to assure that the proposed use/development will not place an undue burden on the existing vehicular transportation system within the vicinity impacted by the proposed development. Attachments 1. Vicinity Map 2. Site Plan 3. Request for Reconsideration Guidelines 4. Development Process Checklist 10 Knight Sky Estat®s/ MPP-06-004/MAZ-O6-005 Proposed Knight Sky Estates Proposed Knighthill Center o.s :_T~ ~~.~~~~ 11 Knight Sky Estates/ MPP-Ofi-004/MAZ-06-005 I i ~~ ~~ SJ--+--s---4 C _n. .;yam---o-~,:F-~'-`J~%~~':f ~ic.w G2 ar ~ _i4 y _.._._..._. s _._. ._ ,~~~~~ I- `0' . I I ~`t {'{ I' C.'.~ r,. I f , ~, ~ f ~ y~„ I I ' F ~ I ~f i 1~ s - ; I I ~ II 5 !~ ~---~::{ ~ ! I -- I y Y ~ I 1 f ~ I - ~ - ~ I t f f. j v y I i ~~ ~,~ i i~ ~ ........M......._- ~ i ~ ~ ~~. _ o .~ ~ ~I ~ a --- __..~._ pf ~ ~ ~~~ ~ ~ - ~ ~ q ;a ~ ~ ~ _ i ~1 d s ~i~~rt r• I ~ ~ ~~~~~~ - 'I ~S~f~F I.. i ~ ~ I ' g~ ~ i- ' iy; - - - ~---- rv= a ~~ ~I fi a B ~ ~ ~~~ ~1jS[f"' j r~1 r q.;l• ! I~ ~ , r 12 C~ ~ !, ,z f ;~ ~ ~ . . 1 ~1 •.. iii , ~....~.~_,-,- . -' •----- i _ ' _ y 41• ~ ICI ~, ~ .~ ~~ i ~~ 1 is Ig G lq _ w~ I ^~Z O =q L. "~ f ~ I ~1 11 . - VG ]~~1 f. •L~ .1 ~e la 4 .p to ..- ..-~_,_. ~- i - ~~ r ip ~ ~ ee F~ b le ~ ~~ 1, • I x r b .~r~ r~ ~' ~ 1p ~o ~ i i I ~ Im ~ , i la;E,~: ~ :i; ~ z y ~e , ~s to ~ ~ ~ I! ~ ( o ~'~ io ~e ~v E ~~ ~•, d~v I~ ~ .~ z ;~ ,e ~ 1 ' ~ ` ~ ~ `1~ o b e~ .• ;a ~ v i ~ ~ r ~ 2 • ~ , ~.~ , `• Fo ;. A.,... ;Q ~ ~ a ! f7' i ~ ~ - 1 9 ,a r I• _Zj .;~ 1m. ~ I '~ ;~ :~ 1 a i~ Im .~ i ~ Ip .o ~ ~ ® ! .' tp ~ 1. i ' p ~ Q 1 ~ Io 5, 1 ~ Ie , io .. ~ C O . ~ y ~~pp ~I_<<~ qf~ `4 I ' ` _ . .e • , ,o 1 I• , t ,~ ~ to Ra ip ~° ~ ~a ` ~ --- , ~ f-~ ... - - ~ =a - . - f ~.._. _.. _..._.._ _ .... -- ------1 -__~__ .._. Knight Sky Estates/ MPP-06-004/MAZ-06-005 • Concept Sketch of Stub to Spurwing S~I 1 1 1 ~ tv wJ1~IK Lwl[~1 ~/ 1 M1 Rwr~~~ •C Mewl; ~I ,,.. ~ 1~ 1 .. .. ~ "." .. .. Ii w~. r..~-I w ~irv .rwwv a.rar 1 1 1 ~ r ^lM-ri 4~~a d \a T\m r r r 1 1 1 1 1 1 I r I ~ i ~~ 1 ~ r. ; rl ~' I ~ ~', I- t 1• ~ ~ ~i •N ..¢~ulrr ~"+A 1 • y ~. T~ x 1 MMl R11~ =vrM On+[IL ~. f/ 1 Cf ~'. r ~ f I. . .. ~~ -, ~ " I _T ~u ur 4I~1 .~i w 4a' Wb+ UtYK "".". ~ q s /at7 w ~r.v=--~....- CrrrfLl p C~7 rrr ~ ..... .. - 1]' Mf~V ~~ -.M f • ~.A • .. .. ~'ais cu+u ~` 13 Knight Sky Estates/ MPP-06-004/MAZ-OG-005 -~ * ~ Request for Reconsideration of Commission Action Request for Reconsideration of Commission Action: A Commissioner, a member of ACRD staff or any other person objecting to any final action taken by the Commission may request reconsideration of that action, provided the request is not for a recansideration of an actian previously requested to be reconsidered, an action whose provisions have been partly and materially carried out, or an action that has created a contractual relationship with third parties. a. Only a Commission member who voted with the prevailing side can move far reconsideration, but the motion may be seconded by any Commissioner and is voted on by all Commissioners present. If a motion to reconsider is made and seconded it is subject to a motion to postpone to a certain time. b. The request must be in writing and delivered to the Secretary of the Highway District no later than 3:00 p.m. on the day prior to the Commission's next scheduled regular meeting following the meeting at which the action to be reconsidered was taken. Upon receipt of the request, the Secretary shall cause the same to be placed on the agenda for that next scheduled regular Commission meeting. c. The request for reconsideration must be supported by written documentation setting forth new facts and information not presented at the earlier meeting, or a changed situation that has developed since the taking of the earlier vote, or information establishing an error of fact or law in the earlier action. The request may also be supported by oral testimony at the meeting. d. If a motion to reconsider passes, the effect is the original matter is in the exact position it occupied the moment before it was voted on originally. It will normally be returned to ACRD staff for further review. The Commission may set the date of the meeting at which the matter is to be returned. The Commission shall only take action on the original matter at a meeting where the agenda notice so provides. e. At the meeting where the original matter is again on the agenda for Commission action, interested persons and ACRD staff may present such written and oral testimony as the President of the Commission determines to be appropriate, and the Commission may take any action the majority of the Commission deems advisable. If a motion to reconsider passes, the applicant may be charged a reasonable fee, to cover administrative costs, as established by the Commission. 14 Knight Sky Estates/ MPP-Ofi-004/MAZ-06-005 v • Development Process Checklist ®Submit a development application to a City or to the County ®The City or the County will transmit the development application to ACHD ®The ACHD Planning Review Division will receive the development application to review ®The Planning Review Division will do one of the following: ^Send a "No Review" letter to the applicant stating that there are no site specific requirements at this time. ^Send a "Comply With" letter to the applicant stating that if the development is within a platted subdivision or part of a previous development application and that the site specific requirements from the previous development also apply to this development application. ^Write a Staff Level report analyzing the impacts of the development on the transportation system and evaluating the proposal for its conformance to District Policy. ®Write a Commission Level report analyzing the impacts of the development on the transportation system and evaluating the proposal far its conformance to District Policy. ®The Planning Review Division will hold a Technical R®view meeting for all Staff and Commission Level reports. ^For ALL development applications, including those receiving a "No Review" or "Comply With" letter: • The applicant should submit two (2) sets of engineered plans directly to ACHD for review by the Development Review Division for plan review and assessment of impact fees. (Note: if there are no site improvements required by ACHD, then architectural plans may be submitted for purposes of impact fee calculation.) • The applicant is required to get a permit from Construction Services (ACHD) far ANY work in the right-0f-way, including, but not limited to, driveway approaches, street improvements and utility cuts. ^Pay Impact Fees prior to issuance of building permit. Impact fees cannot be paid prior to plan review approval. DID YOU REMEMBER: Construction (Zone) ^ Driveway or Property Approach(s) • Submit a "Driveway Approach Request" form to Ada County Highway District (ACHD) Construction (for approval by Development Services & Traffic Services). There is a one week turnaround for this approval. ^ Working in the ACHD Right-of-Way • Four business days prior to starting work have a bonded contractor submit a "Temporary Highway Use Permit Application" to ACHD Construction -Permits along with: a) Traffic Control Plan b) An Erosion & Sediment Control Narrative & Plat, done by a Certified Plan Designer, if trench is X50' or you are placing X600 sf of concrete or asphalt. Construction (Subdivisions) ^ Sedim®nt ~ Erosion Submittal • At least one week prior to setting up a Pre-Con an Erosion & Sediment Control Narrative i~i Plat, done by a Certified Plan Designer, must be turned into ACHD Construction -Subdivision to be reviewed and approved by the ACHD Drainage Division. ^ Idaho Power Company • Vic Steelman at Idaho Power must have his IPCO approved set of subdivision utility plans prior to Pre-Con being scheduled. ^ Final Approval from Development Services ACHD Construction -Subdivision must have received approval from Development Services prior to scheduling aPre-Con. 15 Knight Sky Estates/ MPP-06-004/MAZ-O6-005