E BINGLEY DRIVE-�
4"PI
Id"t,
_ —� r—
_ 30.00' COMMON BLOCK 2 I \
DRIVE/WATER/SEWER I I I — 7
EASEMENT
l 13 i i 12 11 I I 10
14 1 1
CONNECT TO EXISTING I I 9
5 SANITARY SEWER MANHOLE 8
CONNECT TO EXISTING
I I SANITARY SEWER MANHOLE
t—J L(1 /
L
I i
BLOCK 2
19
1
I
20
1
h
I
I I
To
21TI
1
__?
F---------
J.
I
2z
1
h
I
I
To
23
T
L--------J
_ ----------I
24 +
SEWER LINE 'A' J
SEE SHEET C5.0 1.
I
I
$,
oW
I
I1
L
_o
NC9
25
— —
—
NN '� \
V1510FUTURE PHASE
/ , 6
REMOVE EX. 8" BLIND
FLANGE AND CONNECT TO
EXISTING 8" GATE VALVE /
/
/
BLOCK 2
4
/
INSTALL CONCRETE PAD
/
FOR MAILBOXES. SEE
DETAIL 5 SHEET C9.0
3
a
co
OS // BLOCK /
/ 104 1/
REMOVE EX. 8" BLIND
FLANGE AND CONNECT TO
EXISTING 8" GATE VALVE
I
2
ACHD SEEPAGE BED #2
-----J
F---------I
3
I I
L-------- J
— — — r —T—� I� ^(-------� F--------,
I 1 I LJ � 1 \� I r 1 L-------- � 1 1 I
7 I v r--------� 4 I I
/ W BLOCKS I I I--------J
5
1 28 1 1 29 / / % _ \ ACHD SEEPAGE BED #3 I 1 F
—1 L----- --J I BLOCK
BLOCK2 / / 5
30 / / FN 6
/ / / / C�fHA fa
31 / / SEWER LINE 'A' /� - , • RT °° L
ORIVF 8^Ly ' ' . , ;,' — — — — — — — SEE —
/ SHEET C5.0
\ � �/ / / / / / I / / � SS 6
/ --,fir-4-
I
F_____
REMOVE EX!
FLANGE AND
8" BLIND I
CONNECT TO I
I I I
I I 1
EXISTING 12"x8"
REDUCER I
I
I I
1
1 2 I
I 3 I
I 4 I I I
I
00
3
I I
I I
I I
I 5
I I
I I
I I I 16,
L_ —J
L— —J
I
L BLOCK I
— — — — — — — — -
15
¢
--------J
7 I
°z
F---------
I I
¢
14
F---------
o
I I
1
L--------J
I I
8
I I
13
I
L--------J
r SEWER LINE 'B' 1
SEE SHEET C5.1
Al
I
1 9
F--------- A
BLOCK4 1
12 l
1
1
L--------
I IF---------
I
I
10 1
L I
ACHD SEEPAGE BED #1
/ CONNECT TO EXISTING
SANITARY SEWER MANHOLE
10
BLOCK 5
I 1 2 I
I I
+ 9 1 ' F--------,
I I I
FI -------- L--------J I
+ 8 I F SEWER LINE 'C',
I I I SEE SHEET C5.1
L — — — — — — — — J 4
I I
33 / / / / / / 1 <8"SS 8..
34
35
36 / I SEWER LINE
/ SEE SHEET C5.0 I I
37 b I f 38 1 1 39
40 I I 41
BLOCK 2 1 1 1 1
R4gTFR L � -- JI �-- --� L— _I I I 1
FUTURE PHASE — — 6"PI
OFFSITE PRESSURE
IRRIGATION. SEE SHEET C7.0.
�U-Too r,
STUB 8" WATER MAIN AND
INSTALL 2" BLOW -OFF
ASSEMBLY FOR FUTURE
WATER MAIN EXTENSION
STUB 8" SEWER MAIN AND
INSTALL T-TYPE CLEANOUT
FOR FUTURE SEWER MAIN
EXTENSION
IOFFSITE PRESSURE
IRRIGATION. SEE SHEET C7.0.
0 25 50 100 150
SCALE: 1" = 50'
KEYNOTES
lO INSTALL "NO PARKING FIRE LANE" SIGN WITH DOUBLE ARROWS IN ACCORDANCE
WITH MERIDIAN CITY CODE SECTION 7-2-8 AND 2015 IFC SECTIONS 503.3
AND D103.6. ALL STREET SIGNS AND HARDWARE MUST COMPLY WITH MUTCD
STANDARDS.
ENSFO
16970
6-2-22
OOST�TF OF \OP`�` �P�
E M.'�/
JWl
E
>�o
y
C
L) La
o�
x2
mw
�v
v
�rn
am
Ev
u
z
0
a
u
0
0
e
DESIGNED:
C. GRAHAM
DRAWN:
L. HAASE
CHECKED:
C. GRAHAM
APPROVED:
C. GRAHAM
Z
0
U
Z)
PREPARED FOR:
G20 LLC
PO BOX 593
EAGLE, ID 83616
Cn
Z
O
l
0
N
Z
0
Q
d
>
N
Z
Z
Q
Q
d
N
d
_
J
ZD
O
W
Lu
Z
Z:)
cn
>
cJ
Cn
W
Q
co
W
}
%
N
O
W
a
CSW PROJECT NO, 22001
DRAWING DATE 06/02/2022
C/■O