C0.0_Cover Sheet V1m
SHEET INDEX
C0.0
COVER SHEET
C0.1
NOTES
C1.0
FINAL PLAT SHEET 1
C1.1
FINAL PLAT SHEET 2
C2.0
OVERALL SITE/UTILITY PLAN
C3.0
GRADING PLAN
C3.2
DRAINAGE PLAN
C4.0
AVERIL WAY/TINDARIS AVE PLAN AND PROFILE
C4.1
CEDARHURST DRIVE PLAN AND PROFILE
C4.2
PALATINO AVE/ENGLEHART DRIVE PLAN AND PROFILE
C5.0
SEWER LINE A PLAN AND PROFILE
C5.1
SEWER LINE B+C PLAN AND PROFILE
C6.0
WATER PLAN
C7.0
PRESSURE IRRIGATION PLAN
C8.0
STREET LIGHT PLAN
C9.0
ROADWAY DETAILS
C9.1
STORM DRAIN DETAILS
LEGEND
- -
SUBDIVISION BOUNDARY
PUBLIC RIGHT-OF-WAY
ROAD CENTERLINE
LOT LINE
3
LOT NUMBER
CURB AND GUTTER
8"SS>
SEWER MAIN
g"W
WATER MAIN
<12"Sp
STORM DRAIN PIPE
Pi
PRESSURE IRRIGATION MAIN
A
FIRE HYDRANT
SINGLE WATER METER/SERVICE
DOUBLE WATER METER/SERVICE
B.00
2" BLOW -OFF ASSEMBLY
®
GATE VALVE
% V rL ti I.
WATER FITTINGS
0
SEWER MANHOLE
®
CURB INLET
STORM DRAIN MANHOLE
-o
SAND AND GREASE TRAP
MONITORING WELL
STORM DRAIN SEEPAGE BED
sa
BARRICADES
r
STREET SIGNS
STREET LIGHT
PROPOSED MAJOR CONTOUR (5')
PROPOSED MINOR CONTOUR (1')
EXISTING MAJOR CONTOUR (5')
EXISTING MINOR CONTOUR (1')
2.00%
DRAINAGE ARROW WITH PERCENT SLOPE
CALL BEFORE YOU DIG
CALL DIGLINE INC.
PRIOR TO COMMENCING
UNDERGROUND WORK
r-wb.isbeluw' (208) 342-1585
Call berort you my.
SURVEY DATUM
HORIZONTAL DATUM BASED ON ADA COUNTY GIS.
ALL ELEVATIONS SHOWN ARE NORTH AMERICAN
VERTICAL DATUM OF 1988 (NAVD 88).
16
I
17
18
19
I BLOCK 2
20
0
a
0
cf
V
21
a
w
I
w
a
22
O
z
F-
JI
d
23
24
I
25
NOTICE TO CONTRACTORS
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME
SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF
CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY;
THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED
TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO
DEFEND, INDEMNIFY AND HOLD THE ADA COUNTY HIGHWAY DISTRICT, THE CITY OF
MERIDIAN, AND THE DESIGN CONSULTANT HARMLESS FROM ANY AND ALL LIABILITY, REAL
OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT.
UNAUTHORIZED CHANGES OR USES: THE DESIGN CONSULTANT PREPARING THESE PLANS
WILL NOT BE RESPONSIBLE FOR, OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES
OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE
APPROVED BY THE PREPARER OF THESE PLANS.
26
I \
27
28
BLOCK 2
29
IMPROVEMENT PLANS FOR
SKYBREAK SUBDIVISION NO. Z
LOCATED IN THE SE 1 /4 OF THE NW 1 /4 OF SECTION 4
TOWNSHIP 2 NORTH, RANGE 1 EAST, BOISE MERIDIAN
ADA COUNTY, IDAHO
2022
N
0 30 60 120 180
SCALE: 1" = 60'
------------------------ --
SUg����S�ON N�. --
14 13 12 1 1 1 0 9 \ CCFY�R/\ \\
15 8 BLOCK 2 \ F \ \
7
6
(1`__7 74
CFI /
2 3 a /3
��Ry�Rcr 2/ Al
7 Y05 BLOCK 3
// 104 / /
I
\ 30
31
32
33
\ � 34
35
� 1qqRR
Z:3
ACHD CERTIFICATE OF COMPLIANCE
38
BLOCK 2
39
DEVELOPER
G20 LLC
PO BOX 593
EAGLE, ID 83616
(208) 336-5355
LARENOCONGERGROUP.COM
CIVIL ENGINEER
CORINNE GRAHAM, PE
CIVIL SITE WORKS LLC
PO BOX 6059
BOISE, ID 83707
(208) 946-3874
CGRAHAMOCSWENGI NEERI NG.COM
SURVEYOR
JEFF BEAGLEY, PLS
SAWTOOTH LAND SURVEYING LLC
2030 S. WASHINGTON AVE.
EMMETT, ID 83617
(208) 398-8104
E. LAKE HAZEL RD
Uw
U
Q =
�o
00
m�
SKYBREAK
SUB N®
°a
0
V
w
UIELE. COLUMBIA
RD
9���
�
�j VICINITY MAP
(1) SCALE: 1"=1000'
SITE DATA
ADA COUNTY PARCEL #S1404233660
SITE AREA = t11.12 ACRES
PROPOSED LAND USE ZONE:
R-8
NUMBER
AREA
%
RESIDENTIAL LOTS
62
7.68 AC
69.1 %
COMMON DRIVES
2
0.15 AC
1.3%
LANDSCAPE COMMON LOTS
10
0.86 AC
7.7%
PUBLIC RIGHT-OF-WAY
N/A
2.43 AC
21.9%
TOTAL
74
1 1 .1 2 AC
1 00%
IDAHO POWER INFORMATION
PROJECT CONTACT: DIANNE JOSSIS
(208) 336-5355 EXT. 4
DJOSSISOCONGERGROUP.COM
FUTURE PHASES
PHASE
3 9.95
ACRES
51
LOTS
PHASE
4 6.60
ACRES
39
LOTS
PHASE
5 6.03
ACRES
32
LOTS
PHASE
6 3.07
ACRES
15
LOTS
PHASE
7 8.09
ACRES
21
LOTS
PRESSURE IRRIGATION PUMP STATION INSTALLED IN PHASE 1
NO POLE REMOVAL/RELOCATION REQUIRED
a
THE ENGINEER OF RECORD CERTIFIES THAT THE PLANS ARE
PREPARED IN SUBSTANTIAL CONFORMANCE WITH ACHD POLICY AND,p,,,�
�� a
STANDARDS IN PLACE AT THE TIME OF PREPARATION. THE
❑� >
ENGINEER ACKNOWLEDGES THAT ACHD ASSUMES NO LIABILITY FOR
�i'0
ERRORS OR DEFICIENCIES IN THE DESIGN. ALL VARIANCES FROM
";,r{; `
■ •� a
ACHD POLICY SHALL BE APPROVED IN WRITING. THE FOLLOWING
�'#�'��r4'Mr
VARIANCES, LISTED BY DATE AND SHORT DESCRIPTION, WERE
��= {' ;�
APPROVED FOR THIS PROJECT: NONE.
v
n
Ul
JWl
/ l 0
o
11
rn
L] U1
Ln o
-0m
o�
�o
a oo
�r
-
x�
0
CO w
�v
04
am
o
E�
�o
�v
U
w
0
3
0
x
a
0
U
O
U
I
U
o
�n
o
N
�
W
z
DESIGNED:
C.
GRAHAM
DRAWN:
L.
HAASE
CHECKED:
C.
GRAHAM
APPROVED:
C.
GRAHAM
Z
PREPARED FOR:
G20 LLC
PO BOX 593
U
Z)
EAGLE,
ID 83616
V)
Z
O
U
ne
O
N
0
O
>
Z
N
ce
CL
Q
Z
O
(J7
0
Z
QCL
Z
LLJ
w
LLJ
L.')
O
m
2
af
Z
LLJ
Q
LU
O
d
LLJ
O
U
N
LLJ
m
w
cn
d
CSW PROJECT NO. 22001
DRAWING DATE 06/02/2022
CO■O