HomeMy WebLinkAboutFirenze Plaza Shops A - Landscape V1DWT
APPROVED
nh 07mi22
FU I-
8"SS
E. Mount Etna Dr.
8"SS a"ss o me
Landscape Plan
Horizontal Scale: 1" = 10
L_J
P Or WR
„% TH E
LAND
-GROUP
TLG PN: 122072
Sheet Notes:
A. REFER TO SHEET 1-1.50 FOR LANDSCAPE NOTES AND DETAILS.
B. NO EXISTING NATURAL FEATURES SUCH AS CANALS, CREEKS, DRAINS, PONAS, WETLANDS, FLOODPLAINS, HIGH
GROUNDWATER AREAS, AND ROCK OUTCROPPINGS EXIST ON SITE.
C. NO AREAS OF THE SITE ARE STEEPER THAN 20% SLOPE.
PLANT SCHEDULE
CLASS II TREES
BOTANICAL / COMMON NAME
SIZE
CONTAINER
QTY
LA
LIRIODENDRON TULIPIFERA 'ARNOLD' / TULIP TREE
2" CAL.
B&B
4
LF
URIODENDRON TULIPIFERA ' FASTIGIATA' / TULIP TREE
2" CAL.
B&B
3
SHRUBS
BOTANICAL/COMMON NAME
SIZE
CONTAINER
OTY
AL
ARONIA MELANOCARPA'UCONNAM165' TM / LOW SCAPE MOUND BLACK CHOKEBERRY
2 GAL.
10
BEG
BUXUS X 'GREEN GEM' / GREEN GEM BOXWOOD
5 GAL
3
CH
CORNUS ALBA ' BAILHALO' TM / IVORY HALO DOGWOOD
5 GAL
2
CX
CALAMAGROSTIS X ACUTIFLORA ' KARL FOERSTER' / FEATHER REED GRASS
2 GAL
15
FE
FESTUCA GLAUCA'ELIJAH BLUE' / ELIJAH BLUE FESCUE
1 GAL
3
HS
HEMEROCALLIS X ' STELLA DE ORO' / STELLA DE ORO DAYLILY
1 GAL
17
LM
LAVANDULA ANGUSTIFOLIA 'MUNSTEAD' / MUNSTEAD ENGLISH LAVENDER
1 GAL
17
PH
PANICUM VIRGATUM 'HEAVY METAL' / BLUE SWITCH GRASS
2 GAL
11
RG2
RHUS AROMATICA ' GRO-LOW ' / GRO-LOW FRAGRANT SUMAC
3 GAL
5
ROS
ROSA X ' RADCON' TM / PINK KNOCK OUT ROSE
3 GAL
2
SBL
SPIRAEA X BUMALDA ' LIMEMOUND' TM / LIMEOUND SPIREA
3 GAL
4
SM
SALVIA X SYLVESTRIS WAY NIGHT/ MAY NIGHT SAGE
2 GAL.
18
Material Legend
TURF SOD AS REQUIRED TO COMPLETE
3" DEPTH CRUSHED TAN ROCK MULCH
IMPROVEMENTS
RETAIN AND PROTECT EXISTING LANDSCAPE.
REMOVE LANDSCAPE -SEE KEYNOTE
� N0.3 FOR MORE INFORMATION.
MORE
; ~ )
LARGE SANDSTONE BOULDERS, 34DIA. TYP.
Keynotes:
# CALLOUT NUMBERS COORDINATED
TO NUMBERED NOTES BELOW.
1. CREATE A SMOOTH TRANSITION FROM EXISTING SOD TO NEW SOD.
2. 6-IN CONCRETE CURB
3. REMOVE EXISTING LANDSCAPING AS REQUIRED TO COMPLETE IMPROVEMENTS.
ADJUST IRRIGATION AS REQUIRED.
4. RETAIN AND PROTECT EXISTING TREE.
Landscape Calculations:
STREET TREES ALONG E MOUNT EFNA DR FRONTAGE ARE EXISTING:
1 TREE PER 35 LINEAR FEET REQUIRED.
116 LF OF FRONTAGE 13 TREES PROVIDED
PARKING LOT TREES PROVIDED PER END STALL:
1 TREE PER SINGLE ROW PARKING REQUIRED
3 REQUIRED 13 PROVIDED
Project Information:
PROJECT: PROPOSED RETAIL BUILDING
APPLICANT, OWNER
COMPANY: BROWMAN DEVELOPMENT COMPANY
CONTACT: AARONZUZACK
ADDRESS: 1556 PARKSIDE DRIVE
WALNUT CREEK, CA 94596
EMAIL: azuzack@browmandevelopment.com
CIVIL ENGINEER, LANDSCAPE ARCHITECT, LAND SURVEYOR
COMPANY: THE LAND GROUP, INC
CONTACT: JASON DENSMER, PE (PROFESSIONAL ENGINEER)
CONTACT: MICHAEL THOMAS, PLA (PROFESSIONAL LANDSCAPE ARCHITECT)
CONTACT: JAMES R. WASHBURN, PLS (PROFESSIONAL LAND SURVEYOR)
ADDRESS: 462 E. SHORE DR., SUITE 100
EAGLE, IDAHO 83616
PHONE: 208.939.4041
0 10, 20'
o0
o;
00
O
YCR
co
:Q C9
= C!
w
Q O
Cu
O
+ CD
O
N M
Q 00
o
o
t cc
a
U) 01
3 m
0
N
C
N
Q
7T
l0
3
'O
0
O
L
m
CC1
Ch
Cu
Cu
cn _
W z
J z 3 O cn
Q Q S H J Y
U W Q
U N Z= U z
07Z ~NNO
O O S U
WLd
ZO
CONSULTANT STAMP
NOT FOR
AOO OO
CONSTRUCTION
ARCHITECT STAMP
Q
0—
O
�`2^
VJ
J_
Lu
�/
Ld_
O
Z o
Q —
Q Q
c6
N
Q
CB
N
U
0
LL
W Lu
m
J
REVISIONS
NO.
REMARKS
CHECKED
JCD/MRT
DATE
06-09-22
DRAWN
TLG
JOB NO.
-
SHEET NUMBER
L100
N
I
CD
I
co
0
Lu
U)
U
U
APPROVED
0712„2
Landscape Notes:
A. CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPER
EXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK.
B. FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN.
REMOVE RIDGES AND FILL DEPRESSIONS, AS REQUIRED TO MEET FINISH GRADES. PLACE 3" OF ROCK MULCH OVER SUBGRADE SOIL
TO ACHIEVE FINISH GRADE. FINISH GRADE RELATED TO ADJACENT SITE ELEMENTS SHALL BE:
B.A. 1-INCH BELOW TOP OF ADJACENT PAVEMENT, VALVE BOX, VAULT, ETC.
B.B. 3-INCHES BELOW TOP OF CURB UNLESS NOTED OTHERWISE.
C. ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 18" OF TOPSOIL, SOD AREAS A MINIMUM OF 12" OF TOPSOIL. SPREAD, COMPACT
AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE.
D. RE -USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OF SURFACE SOIL TO PRODUCE TOPSOIL MEETING
REQUIREMENTS AND AMEND WHEN NECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC
MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHER FOREIGN MATERIAL AND A PH OF 5.5 TO 7.0. IF ON -SITE
TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A) PROVIDE APPROVED
IMPORTED TOPSOIL, OR B.) IMPROVE ON -SITE TOPSOIL WITH METHODS APPROVED BY LANDSCAPE ARCHITECT. SUPPLEMENT WITH
IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS, PLANTS, SODS, STONES, CLAY LUMPS AND
OTHER EXTRANEOUS MATERIALS HARMFUL TO PLANT GROWTH.
E. IF IMPORTED TOPSOIL FROM OFF -SITE SOURCES IS REQUIRED, PROVIDE NEW TOPSOIL THAT IS FERTILE, FRIABLE, NATURAL LOAM,
SURFACE SOIL, REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS, STUMPS,
STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH.
F. OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THAT FOUND AT PROJECT
SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY, WELL -DRAINED SITES WHERE TOPSOIL OCCURS IN A DEPTH OF NOT LESS THAN 4
INCHES.
G. ALL LANDSCAPE AREAS SHALL BE WEED FREE AT THE TIME OF LANDSCAPE INSTALLATION.REMOVE ALL ROOTS, WEEDS, ROCKS
AND FOREIGN MATERIAL ON THE SURFACE.
H. NEW TREE PLANTING, SEE DETAIL 1/11.50. CONTRACTOR SHALL STAKE ALL TREES DEEMED NECESSARY, LE..... FROM BEING
BLOWN OVER, PLANTED WITH LOOSE ROOT BALL, ETC. CONTRACTOR'S OPTION.
I. NEW SHRUB PLANTING. SEE DETAIL 2/1-1.50.
J. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL
BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION.
K. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF SUBSTANTIAL COMPLETION.
REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAME SIZE AND SPECIES AT
NO COST TO THE OWNER.
L. TREE PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR TREE PIT BACKFILL AT THE
FOLLOWING RATES. BLEND AMENDMENTS THOROUGHLY WITH SOIL BACKFILL. TREE PITS SHALL BE 5'x5'x1.5' (37.5 CF/ 1.5 CY).
L.A. APPLICATION RATES:
L.A.A. HUMIC ACID: 25 LBS PER TREE PIT
L.A.B. COMMERCIAL GRADE COMPOST -10 CUBIC FEET PER TREE PIT
L.A.C. PLANTING TABLET FERTILIZER - 4 TABLETS PER TREE PIT
L.A.D. CALCIFIED DIATOMACEOUS EARTH - 75 LBS PER TREE PIT
M. SHRUB PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR SHRUB PIT BACKFILL AT THE
FOLLOWING RATES. BLEND AMENDMENTS WITH THOROUGHLY WITH SOIL BACKFILL. SHRUB PITS SHALL BE 2.5'x2.5'x1' (6.25 CF/
0.25 CY).
M.A. APPLICATION RATES:
M.A.A. HUMIC ACID: 2 LBS PER SHRUB PIT
M.A.B. COMMERCIAL GRADE COMPOST - 2 CUBIC FEET PER SHRUB PIT
M.A.C. PLANTING TABLET FERTILIZER - 2 TABLETS PER SHRUB PIT
M.A.D. CALCIFIED DIATOMACEOUS EARTH - 15 LBS PER SHRUB PIT
N. IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSE OF
PROPERLY OFF SITE.
0. CONTRACTOR SHALL SUBMIT MATERIAL SAMPLES FOR LANDSCAPE ROCK MULCH TO LANDSCAPE ARCHITECT FOR APPROVAL
PRIOR TO PROCUREMENT. LANDSCAPE BOULDERS, PHOTO SUBMITTAL IS ADEQUATE. FOR ROCK MULCH, SUBMIT 1 GALLON BAG
SAMPLE TO OWNER.
Automatic Underground Irrigation Notes:
A. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICH ENSURES COMPLETE COVERAGE
AND PROPERLY ZONED FOR REQUIRED WATER USES.
B. EACH HYDROZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS.
C. POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 18" AT PLANTER BEDS, 6" AT LAWN AREAS..
D. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEMS - WITH DRIP CONTROL ZONE KIT AND 150 MESH FILTER (MIN.).
E. ELECTRONIC WATER DISTRIBUTION/ TIMING CONTROLLERS ARE TO BE PROVIDED. MINIMUM CONTROLLER REQUIREMENTS ARE AS
FOLLOWS:
E.A. PRECISE INDIVIDUAL STATION TIMING
E. B. RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES
E.C. AT LEAST ONE PROGRAM FOR EACH HYDROZONE
E. D. SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF
E. F. POWER FAILURE BACKUP FOR ALL PROGRAMMED INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND
INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO -ZONES.
F. INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO -ZONES.
G. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR
SPACING AS APPROPRIATE.
H. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES SUCH AS SIDEWALKS, DRIVEWAYS,
AND PARKING AREA.
I. EACH VALVE SHALL BE INSTALLED IN A VALVE BOX LARGE ENOUGH TO ALLOW FOR MAINTENANCE AND REMOVAL. ONLY ONE VALVE
PER BOX.
Tree Protection Notes:
A. PROTECT THE CRITICAL ROOT ZONE OF THE TREES TO BE RETAINED ON SITE: (NOTE: CRITICAL ROOT ZONE IS THE AREA DIRECTLY
BELOW THE DRIP LINE OF THE TREE.)
A.A. CONSTRUCT PROTECTIVE FENCING OF CHAIN -LINK AROUND THE CRITICAL ROOT ZONE PRIOR TO DEMOLITION OR
CONSTRUCTION.
A. B. DO NOT ALLOW COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING DEMOLITION.
A.C. DO NOT ALLOW CEMENT TRUCKS TO RINSE WITHIN THE PROTECTION AREA, ANYWHERE THAT TREE ROOTS EXIST OR IN
PLANNED PLANTING BEDS.
A. D. DO NOT STOCKPILE MATERIALS, DEBRIS OR DIRT WITHIN THE TREE PROTECTION AREA.
A. E. MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF NOT LESS THAN
THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK.
A. F. DO NOT TRENCH, EXCAVATE, FILL OR OTHERWISE DISTURB THE SOIL WITHIN THE CRITICAL ROOT ZONE.
A.G. ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE ROOTS.
B. PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED ON SITE:
B.A. OPERATE EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR BRANCHES.
B. B. PRUNING OF PUBLIC PROPERTY TREES SHALL BE PERFORMED BY A LICENSED ARBORIST.
C. ALL TREES DAMAGED OR DESTROYED DURING CONSTRUCTION SHALL BE REPLACED USING THE FOLLOWING CRITERIA:
EXISTING TREE REPLACEMENT
1 " TO 6" CALIPER .........................2X CALIPER OF TREE REMOVED
6" TO 12" CALIPER ......................1.5X CALIPER OF TREE REMOVED
> 12" OR LARGER CALIPER IX CALIPER OF TREE REMOVED
EXAMPLE: IF AN 8" CALIPER TREE IS REMOVED, AN ACCEPTABLE REPLACEMENT WOULD BE (3) 4" CALIPER TREES OR (4) 3"
CALIPER TREES.
NOTES:
1. THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR IS
RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN
STRAIGHT FOR A MINIMUM OF 1 YEAR. ALL STAKING SHALL BE REMOVED AT THE END OF THE ONE
YEAR WARRANTY PERIOD.
2. IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TO
NOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING.
3. LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TO
INSTALLATION OF PLANT MATERIAL.
4. WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE
STANDARD OR FIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITH
GALVANIZED NAILS TO PREVENT SLIPPAGE.
5. WATER TREE TWICE WITHIN THE FIRST 24 HOURS.
6. IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPE
ARCHITECT IMMEDIATELY.
ROOT PROBE
SOIL LINE
UTILIZE SOIUR00T PROBE AROUND TRUNK
(APPROX. 34" AWAY FROM TRUNK) TO LOCATE
HIGHEST ROOTS. HIGHEST ROOTS SHOULD BE
POSITIONED AT OR SLIGHTLY ABOVE GRADE LEVEL. L (� L. (� ✓.✓lug AL
REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP
Y OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTIC
FROM ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TO
WRAP THE ROOTBALL, IT SHALL BE COMPLETELY
REMOVED. ONLY BIODEGRADEABLE BURLAP SHALL BE
LEFT ON THE BOTTOM OF THE ROOTBALL.
Deciduous Tree Planting
Scale: NTS
MULCH LAYER
COMMERCIAL
FERTILIZER TABLETS
Shrub Planting
Scale: NTS
� n
3"
— 2x ROOTBALL DIAMETER -
- 3x ROOTBALL DIAMETER —
WATER RETENTION
BASIN
BACKFILL WITH SOIL PLANTING
MIX. SEE SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
SOIL PLANTING N
SPECIFICATIC
ADDITIONAL INFOR
REMOVE DEAD/DAMAGED BRANCHES AND PRUNE TO
INTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS,
IMPROPERLY PRUNED TREES (AS DETERMINED BY THE
LANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED.
PREVAILING WIND DIRECTION
TREE WRAP TRUNK PROTECTION,
REMOVE AFTER INSTALLATION
RUBBER CINCH TIE
2" x 2" x T CEDAR STAKE - DO NOT PENETRATE FOOTBALL.
SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND.
MULCH LAYER, KEEP MULCH 3" AWAY FROM
TRUNK
BACKFILL WITH SOIL PLANTING MIX. SEE
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
COMMERCIAL SLOW RELEASE FERTILIZER TABLETS
SET ROOTBALL ON NATIVE UNDISTURBED SUBSOIL
Concrete Edging
Scale: NTS
/��I. � III
LAND
GROUP
TLG PN: 122072
4" x 6" EXTRUDED
CONCRETE MOW STRIP
1/2" RADIUS
FINISH GRADE
TOP SOIL
COMPACTED
SUB -GRADE
W
�
E
o;
00
Y �
00
�Q C9
� C?
iQ co
CU
CV
0
+ m
C3
N Colo)o a �
�_ O
t
N 01
3 m
O
N
7
C
Q
7T
3
'O
c0
L
m
GO
C9
CU
CU
w z z
J o �
U U W Z I U Z
U�
a
m z o 1 �
z2U
=o Qa
w z CD
o
CONSULTANT STAMP
iEOF oiyo
\\\\0�PI��i
R. Ty
G �
2 LA-16888�
L9ADSCA4s\\\
/7Z//IIIII\\\06/09/2022
ARCHITECT STAMP
0-
O
2
(n
J_
W
N
Z 0
z
0 Q
O
z
-0
(0
N �
W �
C w
G
�
co
�
REVISIONS
NO.
REMARKS
CHECKED
JCD/MRT
DATE
06-09-22
DRAWN
TLG
JOB NO.
-
SHEET NUMBER
L150
N
CD
co
0
1—
/Wf^
VJ
U
N
U