HomeMy WebLinkAboutConstruction Drawings C-001 V1V z W W z z W m 1 Aq LEGEND EXISTING PROPOSED PERMANENT EASEMENT BOUNDARY LINE SECTION LINE — s — — — — — SANITARY SEWER LINE a+ w WATER LINE • — IRR — GRAVITY IRRIGATION PIPE ea — — — PIPE — PRESSURE IRRIGATION LINE_PM_ — — — Sr STORM DRAIN LINE +o — — CENTERLINE PUBLIC RIGHT OF WAY LINE -- P/L LOT LINE 6" VERTICAL CURB AND GUTTER 6" VERTICAL CURB (NO GUTTER) ROLLED CURB & GUTTER 5' SIDEWALK Os SEWER MANHOLE C) STORM DRAIN MANHOLE O GRAVITY IRRIGATION MANHOLE 0 DITCH FLOW LINE PRESSURE IRRIGATION SERVICE STREET LIGHT QO FIRE HYDRANT i EDGE OF GRAVEL OVERHEAD POWER o,o FENCE LINE -----■ ----- ■- -a— STREET SIGN T SINGLE WATER SERVICE DOUBLE WATER SERVICE WATER VALVE H CONCRETE SIDEWALK ASPHALT ROADWAY ABBREVIATIONS ACHD ADA COUNTY HIGHWAY DISTRICT BC BARRIER CURB BFE BASE FLOOD ELEVATION CB CATCH BASIN CL CENTER LINE 0 o EG EXISTING GROUND FG FINISH GRADE o FL FLOWLINE o GB GRADE BREAK w GWE GROUND WATER ELEVATION x a HP HIGH POINT 5 IRR IRRIGATION 00 ISPWC IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION PC POINT OF CURVE PCC POINT OF COMPOUND CURVE o PRC POINT OF REVERSE CURVE a PIRR PRESSURIZED IRRIGATION z PT POINT OF TANGENCY z SD STORM DRAIN �z SS SANITARY SEWER w SDMH STORM DRAIN MANHOLE a SSMH SANITARY SEWER MANHOLE �¢ Y z STA STATION m U o SW SIDEWALK o U TES THICKENED EDGE SIDEWALK N N NC TOP BACK OF VERTICAL CURB N VOL VOLUME W WATER o� a o WSE WATER SURFACE ELEVATION GORILLA MIND r 0 500 1,000 SCALE IN FEET BASIS OF COORDINATES AND ELEVATIONS ADA COUNTY GIs COORDINATE SYSTEM, MODIFIED ID WEST TRANSVERSE MERCATOR PROJECTION ORIGIN LATITUDE N41'40' ORIGIN LONGITUDE W115°45' FALSE NORTHING: 0 FT FALSE EASTING: 2625138.999 FT SCALE FACTOR (TRIMBLE) 1.0001132803 UNITS: US SURVEY FEET HORIZONTAL DATUM: NAD83(CORS) VERTICAL DATUM: NAVD88/GEOID09 HORIZONTAL & VERTICAL COORDINATES ARE BASED ON IDTD CORS EPOCH 2O02 (PID:AJ3346) N43'39' 10.57391 " W 1 16° 17' 00.21354" Ht: 2589.227 N: 724441.996 E: 2483948.698 EL: 2644.859 The Engineer of Record certifies that the plans are prepared in substantial conformance with the ACHD policy and standards in effect at the time of preparation. The Engineer acknowledges that ACHD assumes no liability for errors or deficiencies in the design. all variances from ACHD policy shall be approved in writing. The following variances, listed by date and short description, were approved for this project: NONE. MERIDIAN, ID E. FRANKIUN ROAD PROJECT NO. 10-21-127 J-U-B ENGINEERS, INC. 2760 West Excursion Lane, Suite 400, Meridian, Idaho 83642 p 208 376 7330 w www.jub.com THE GATEWAY OTHER J - U - B COMPANIES ® LANGDON �.;� MAPPING GROUP ' INC. Sheet List Table Sheet Number Sheet Title C-001 COVER SHEET C-002 NOTES SHEET C-100 EXISTING CONDITIONS AND DEMOLITION PLAN C-200 GRADING PLAN C-300 PARKING LOT PLAN C-301 DRAINAGE PLAN C-400 WATER AND SEWER PLAN C-500 SITE DETAILS DEVELOPER: POWER: HANSEN-RICE IDAHO POWER JUSTIN TOUCHSTONE ARLIN SMITH 1717 E CHISHOLM DR 10790 FRANLIN ROAD NAMPA, ID 83687 BOISE, ID 83709 PHONE (208) 442-4240 PHONE: (208) 388-2167 EMAIL: JTOUCHSTONE@HANSEN-RICE.COM ROADWAYS ADA COUNTY HIGHWAY DISTRICT 3775 ADAMS STREET GARDEN CITY, ID. 83714 PHONE : (208) 387-6100 REUSE OF DOCUMENTS IRRIGATION DISTRICT: SETTLERS IRRIGATION DISTRICT 1910 N GARDEN ST. BOISE, IDAHO 83706 PHONE : (208) 343-5271 J-U-B grants to CLIENT a nonexclusive, non -transferable license to use the Drawings, Specifications and/or Contract Documents (Documents) as follows: CLIENT may make and retain copies of the Documents for reference, but J-U-B shall retain all common law, statutory and other reserved rights, including the copyright thereto, and the same shall not be reused on this Project or any other Project without J-U-B's prior written consent. Distribution of Documents to meet regulatory or permitting requirements, or for similar purposes, in connection with the Project, including but not limited to distribution to contractors or subcontractors for the performance of their work, is not to be construed as publication adversely affecting the reserved rights of J-U-B. The Documents are not intended for use in creating dtm for grading or earthwork, survey staking layout (unless specifically identified as such in the documents), or property boundary layouts. Any reuse without written consent by J-U-B, or without verification or adoption by J-U-B for the specific purpose intended by the reuse, will be at CLIENT's sole risk and without liability or legal exposure to J-U-B. The CLIENT shall release, defend, indemnify, and hold J-U-B harmless from any claims, damages, actions or causes of action, losses, and expenses, including reasonable attorneys' and expert fees, arising out of or resulting from such reuse. If the Documents are provided in electronic format, the electronic documents are subject to the provisions of J-U-B's "electronic document/data limited license" found at edocs.jub.com. (Jew J-U-B ENGINEERS, INC. U Z — J N C/J M IY • LD C) � 00 ° E W W U ��O cfl o 0 W Z3 a 3� Z (tt § 3 c 3 LU 00 co a N AGENCY REVIEW jF 9rF OF \Q S�F/G H M MPSS NOT FOR CONSTRUCTION p � w Z zW m AZ a p � afwo¢o Ir U m W a= Q OHW�� U p m 0>fa.Ema O ui��x H O w ' t9HZ0 } zF3am- 3 U N z z K 2 p➢ W o ZO Z, I) oz=�°� w z o o W H 0 Z Vl�wO W ¢] a_ Il W O E jF�CLF U 2W 2_7 LU Z F N 7 2 p Fw-Ox3 W K W O W [➢ J QWoU,Y = K Z 0 0 n (if W W Of m = ¢ > W �Om Qm O z0 � W �z W Q Q to am= Fr Cc O /O w U `J 2 • • e FILE: 10_22_019_C-00 JUB PROJ. # : 10-21-127 DRAWN BY: KMM Know VVws below. DESIGN BY: KMM Call before ym dig. I CHECKED BY: KHM CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, AT FULL SIZE, IF NOT LAST UPDATED: 5/12/2022 SHEET NUMBER: GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES —00 J I