Loading...
HomeMy WebLinkAboutPLN C4.01 UTIL V1aERIDIAN;•- APPROVED 07/08/22 RIM=2687.61' I.E.(N/EIS)=2674.51' III III III III III III III III III III III III III III III III III III II III III III III III III III II ul III III II ul III III III III III III III III III III III III III III III III III II II III III III III E I /II W W S S III I — m z �I IRE FENCE ------ --- EX 111i 1 � ®Icv I ® c=====-------==---==---==--�==------------- I I° 11ia� �j1i -- — �I�---------- _ _ _ cl, —--------- --4 — — -- - -- __--- - O 15.9 WIDE INGRESS/ 13 GRE79EASEMENT I IF- -----J ' I ■— — SSMH III II ■ ��. RIM=2680.74' II \ LE.(SIE)=L678.14 I • , �, LL I I III ■ I I I-----_=C ���� I 1 II • I I f I I \ I I III I II°• I EXISTING FIRE HYDRANT TO REMAIN I I I 1 I I I VV I�I I p° J 1 •I I I I Ij1 I I R I I'I I II ml I,,I I I 1 illl r-.- L- f I� I I III I II � I° � a• `° 1 III ,1 I I ■ n I I I II I I° °1 °I° ; 1° I I I Iw I p• � a II"I I 1 I I• I II I__JI1 }J 11I � II 11 I I ------ill I III � � I I �_�_� I I•,I �I11I ■ I I I II I ° I I 1 1 I II I 9 I 4------- p ----- l co a � Ids I I I 4- ---- ��� I III I II I 1 . , •ej 1 30'WIDE SEWERS WATER MAIN EASEMENT, I I--------- EXISTING FIRE HYDRANT TO REMAIN PER INGLEWOOD PLACE I lii II ' a 1 1 I SUBDIVISION NO. 1------,ii i W W W W W f i I ■ SSMH I I RIM=P683.86' II — — — — )-------Li ' s s s s s s )------JI-- J-- s ILE.(NA^n=2677.36' -- ?------ -- III• I I — -- _--- _ _--- T � � I EXISTING FIRE HYDRANT TO REMAIN / -�--------I---- h I I LOT 1., BLOCK 1 - WII--I-------t----- - - I \I I I I 1 � 1 11 --------- INGL 11Y100D P ACE DIVISION -NO., I ------------- i 4---J ---I-------il I (PIPOS L ------i------- _______ ^i ■ � �� _ I- ' II I I 11 1I I I FUTURE I i i--------------1 IL======'i m J O i 4,550 S.F. i ________ _______) (_______�I ■ 11 \ \ • �� s I I BUILDING I I ------- I I � I I I• I�° ° I I I ------- I I n ■ I I II 1 ° • I° = I I - ------------- -- �� II 10 I I I`------- i I I � I 11 11 I I 11m I I •I I I I "I .III F r�-------------� IL------� 26.00' EX ACCESS I ■ � \\ ���------- - 1 )-------;'� 1 11 I I II - I I• I I 1 1 I II I EASEMENT-------���� ■ I�. I 1.'� IIII \ \ ps \ II n ■ 1 � < I I I X i I .I ®g 10 9 m I I I � I I I10 — 1I III I I II \ I ' I I I 11 I (•° \ -� ____ °��� I ■ IF I� v ii �vv I I I( J I q�-� :A • .� I I I I PROPOSED I ° I i I I BUILDING v u `I I I` L I I-V � ! , FIFE =2691.00' _ �,.BO II `— • 2.365SQ.FT.EXISTING FIRE REMAIN II'I 11 HYDRANT TO REMAIN—= --- —�i a T -- --- a-------- �� -- IT�� I -I IE@BLDG=2686.00 6. `IE@C0=2687.00070A1^E==_��/ �;_ —__ —__ \\ -I --- o ■ 7 S a SHERGAR LANE -— ___- o f CC I o� I f fl al ii ii 5 I uSw -------- --- ----------------------- (PRIVATE) T BRONDED�z.owsF_ v �I ��-----------------------��--------- LOTIOPQlsBACE 11 -� T REp 1.9s7sFlsxl \—________- - ' f ----- = g I---- 5 - SSIAI MARREfF ------ ----------t�--- Q �" 7 7IE@C0=2684.10--- -----4 \\\� CL MCDONALD LATERAL , ;I -- - - — - - — - - — - - — - - — - --- --- _------------- \\ 7 — — — I — — — _ — — — — — — — — — — o\ -- a - --- -- .- EDGE OF -- -- -- - -_ _-_ __ _= -_= _= _= _= _==J\ASPHALT 0� EX 1-12" WATER METER FROM PLAT IMPROVEMENT PLANS —•�_ _ i SSMH i i �- RIM=2693.13' i - - I.E.(NIUSNQ=2681.43' i W W W W W W W II W W W W W—�' —__—__------ —___ i_—________—_______—__—_____—__—__—__—__—__—__—__—_ _ ___------ — .. _ BA S S a- S S S S E VICTORY RD o (96.0' WIDE PAVED PUBLIC ROAD) _----------- — — — —- III III ,II S S S S j ,ra S S s SSMH RIM=2690.,6' I.E.(EIW/S)=2679.51' H IS Lu III Z I` ILJ 1III a 111I` � 1111 � 11I I z 1 II� �_ 1111I H III, I= 1111 M pl � y � I � I I � I II I, Ill II 1 11111 I I111I� IIII I I 111 I, IIII I I IIII III° I I IIII I I 1 \I 111 II � I- II II II I I� 1 111 I� III= 1111 Ipl III, Ipl Ipl III, IIII Ipl II I 1111 1I1I1 I I p� I I I� I I II I rt II II II I I Ir' I �I = IIII IZ IIII, Lu 11 I I I Q I111� � I111 I� I111 Z I11I, I� II11 � ICI 12 ICI` I I � IIII O I111� N I111 Iql, IIII IIII o N N _------------ SONTHWAR1 WRNEROFSECT10N21, nnn TONNSHIP 3 NORTH, RANGE I EAST, 41, BOISE MERIDIAN.(PER CPFBR ENT. 970093907) NORTH as SCALE: 1" = 30' 0 15' 30' 60' 90, GENERAL NOTES: CONTRACTOR IS TO COORDINATE ALL SITE UTILITIES WITH PLUMBING DRAWINGS ALL NEW WATER CONSTRUCTION TO BE DONE IN ACCORDANCE WITH LOCAL GOVERNING MUNICIPALITY STANDARDS 8 SPECIFICATIONS. ALL NEW SANITARY SEWER CONSTRUCTION TO BE DONE IN ACCORDANCE WITH LOCAL GOVERNING MUNICIPALITY STANDARDS 8 SPECIFICATIONS. CONTRACTOR SHALL FIELD VERIFY LOCATIONS AND INVERT ELEVATIONS OF EXISTING MANHOLES AND OTHER UTILITIES BEFORE STAKING OR CONSTRUCTING ANY SEWER LINES. FOUR FEET OF COVER IS REQUIRED OVER ALL SEWER LINES. MAINTAIN A MINIMUM OF 48INCHES OF COVER ON ALL WATER LINES. CONTRACTOR IS TO COORDINATE LOCATION AND DESIGN OF NEW COMMUNICATION / DATA FACILITIES TO BUILDING WITH UTILITY PROVIDER. CONTRACTOR IS TO COORDINATE LOCATION AND DESIGN OF NEW NATURAL GAS FACILITIES TO BUILDING WITH DOMINION ENERGY AND MECHANICAL PLANS. LOCATION OF ALL UNDERGROUND UTILITIES SHOWN ARE APPROXIMATE LOCATIONS. CONTRACTOR IS TO VERIFY CONNECTION POINTS WITH EXISTING UTILITIES. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE CAUSED TO EXISTING UTILITIES AND UTILITY STRUCTURE THAT ARE TO REMAIN. UTILITY PROVIDERS: WATER: MERIDIAN WATER SEWER: MERIDIAN SEWER NATURAL GAS: DOMINION ENERGY ELECTRICAL POWER: POWER PROVIDER TELEPHONE: CENTURY LINK KEYED NOTES: PROVIDE INSTALL Al CONSTRUCT THE FOLLOWING PER THE SPECIFICATIONS GIVEN OR REFERENCED AND THE DETAILS NOTED AND AS SHOWN ON THE CONSTRUCTION DRAWINGS OCONNECT ONTO EXISTING 1-1/2" WATER METER WITH 1-12" POLY PIPE TO THE BUILDING. MINIMUM 48" COVER OVER TOP OF PIPE. SEE PLUMBING PLANS FOR CONTINUATION INSIDE THE BUILDING. OSANITARY SEWER SAMPLING MANHOLE, PER MERIDIAN CITY SEWER STANDARDS. RIM: 2989.69 IE IN: 2684.89 IE OUT: 2684.64 O800 GALLON GREASE INTERCEPTOR, PER PER MERIDIAN CITY SEWER STANDARDS W RIM: 2689.87 E RIM: 2689.81 IE IN: 2685.28 IE OUT: 2684.95 CONTRACTOR TO FIELD VERIFY LOCATION, ELEVATION, AND SIZE OF STUBBED SEWER LATERAL OPRIOR TO CONSTRUCTION AND CONNECT ONTO EXISTING LATERAL PER MERIDIAN SEWER STANDARDS AND SPECIFICATIONS. IF SEWER LATERAL IS NOT DEEPER THAN 2683.80', CONTRACTOR TO CONTACT ENGINEER OF RECORD FOR ALTERNATIVE SEWER DESIGN. GREASE WASTE ONLY 6" PVC SDR-35 SANITARY SEWER LATERAL AT 2% MINIMUM SLOPE, INCLUDING O5 ALL FITTINGS. CLEANOUTS AT 100-FOOT MAXIMUM SPACING. SEE APWA PLANS NO.381 8 382 FOR TRENCHING. SEE APWA PLAN NO.431 FOR CLEANOUTS. O6"PVC SDR-35 SANITARY SEWER LATERAL, INCLUDING ALL FITTINGS AT 2%MINIMUM SLOPE. CLEANOUTS AT 100-FOOT MAXIMUM SPACING. TRENCHING AND BACKFILL PER MERIDIAN STDS. O7 SANITARY SEWER CLEANOUT, PER APWA PLAN NO.431. O8 LIGHT POLE. SEE ELECTRICAL PLANS FOR DETAILS. APPROXIMATE LOCATION OF NEW NATURAL GAS FACILITIES. CONTRACTOR TO COORDINATE SIZE, O9 DESIGN AND INSTALLATION BY DOMINION ENERGY WITH OTHER CONSTRUCTION. THE MINIMUM SERVICE SIZE IS 1-112" WITH LOW PRESSURE (7" WC OR LESS) 10 CONTRACTOR TO FIELD VERIFY POTENTIAL CASINGS UNDER CANAL AND REPORT TO ENGINEER OF RECORD. CAP CASINGS NOT IN USE. 11 CONTRACTOR TO FIELD VERIFY EXISTING VERTICAL 4" WHITE PVC PIPES AND REMOVE ANY UNDERGROUND UTILITY UNDER THE PROPOSED BUILDING FOOTPRINT. 12 APPROXIMATE LOCATION OF 400A MAIN ELECTRICAL PANEL. CONTRACTOR TO COORDINATE SIZE, DESIGN AND INSTALLATION BY IDAHO POWER WITH OTHER CONSTRUCTION. 01GLIN- c4a'ge~ ?poa 49* NOTICE, CALL 811 BEFORE YOU DIG! THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION, PROTECTION, AND RESTORATION OF ALL BURIED OR ABOVE GROUND UTILITIES, SHOWN OR NOT SHOWN ON THE PLANS. u au 3 Z" y s c 41 u(A �m W Y u oii i W 0 o a ao r 'jam ^. O- o i � 7 2 m !n J C o J to Z54 a y ■ Lu 5 ro NC I. O 4) W� OA W Z E b 'i N L. 0 LiLu Y a T b-0 7 N u U) u0 0 m W TA LLI � a 0�/ rn LA u■r 00 �J 0=0 VMN >Zo �QW LaILL OC O O W Ln���-I N H M W 2 H Z W Q u O J Z O F G PROJECT NO: 21070 DRAWN BY: CCW CHECKED BY: RJP DATE: FEBRUARY 7, 2022 PUBLIC UTI LITY PLAN C4.01