TY OF MERIDIAN STANDARD NOTES
GENERAL NOTES
LEGEND
a
APPROVED
oA1E 07MM2
GENERAL CONSTRUCTION
ALL CONSTRUCTION WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT VERSION OF
1.1 COMPLIANCE
1. ALL WORK TO CONFORM TO GOVERNING MUNICIPALITY'S STANDARDS, SPECIFICATIONS AND
NEW
EXISTING
NEW
EXISTING
L
`
N
O
THE IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION (ISPWC), THE CITY OF MERIDIAN
REQUIREMENTS.
FUNOMBFN
SUPPLEMENTAL SPECIFICATIONS TO THE ISPWC (AND ANY ADDENDUMS), MERIDIAN DESIGN
STANDARDS, THE REQUIREMENTS OF THE ADA COUNTY HIGHWAY DISTRICT (ACHD), AND/OR THE
REQUIREMENTS OF THE IDAHO TRANSPORTATION DEPARTMENT (ITD). THE MORE STRINGENT OF
2. ALL CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THESE CONTRACT
DOCUMENTS AND THE MOST RECENT, ADOPTED EDITIONS OF THE FOLLOWING: INTERNATIONAL
BUILDING CODE (IBC), THE INTERNATIONAL PLUMBING CODE, STATE DRINKING WATER
- - - -
- -
- - MONUMENT LINE
SECTION CORNER (FOUND)
v
^�
;
V V)
j 2
ANY OF THESE STANDARDS SHALL BE THE CONTROLLING STANDARDS OR SPECIFICATIONS.
REGULATIONS, APWA MANUAL OF STANDARD PLANS AND SPECIFICATIONS, ADA ACCESSIBILITY
GUIDELINES.
CENTER LINE
c
la Y
L ab
a o0
2. THE CONTRACTOR SHALL HAVE A COPY OF THE LATEST CITY OF MERIDIAN STANDARD
3. ALL CONSTRUCTION SHALL BE AS SHOWN ON THESE PLANS. ANY REVISIONS MUST HAVE PRIOR
WRITTEN APPROVAL.
- - - -
- -
- - SUBJECT PROPERTY LINE
SECTION CORNER (NOT FOUND)
0
I
o
n
_
SPECIFICATIONS AND DRAWINGS ON SITE OR READILY ACCESSIBLE AT ALL TIMES DURING
a
>-
O.
CONSTRUCTION (AVAILABLE ON THE WEBSITE). FAILURE TO HAVE ACCESS TO A CURRENT COPY
ADJACENT PROPERTY LINE
Id 4)OF
THE STANDARD SPECIFICATIONS ON SITE COULD BE GROUNDS FOR A STOP WORK ORDER
1.2 PERMITTING AND INSPECTIONS
Q
STREET MONUMENT
Z
N
N
UNTIL THE SITUATION IS RESOLVED.
1. PRIOR TO STARTING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING
- - - - - - -
- - - - -
- - EASEMENT LINE
2
•O L
SURE THAT ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN OBTAINED. NO
0
0
BRASS CAP MONUMENT
c
O
O
3. THE CONTRACTOR SHALL HAVE PLANS STAMPEDAPPROVED FOR CONSTRUCTION" BY THE CITY
CONSTRUCTION OR FABRICATION SHALL BEGIN UNTIL THE CONTRACTOR HAS RECEIVED
DITCH FLOWLINE
w
O
o
OF MERIDIAN ON SITE AT ALL TIMES.
THOROUGHLY REVIEWED PLANS AND OTHER DOCUMENTS APPROVED BY ALL OF THE
PERMITTING AUTHORITIES.
X
X
FENCE LINE
$
8
POWER POLE
6_
a
o
�
_3a
C
2. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING AND NOTIFYING ARCHITECT/ENGINEER OR
8
$
UTILITY POLE
J
4. ALL CONTRACTORS, SUBCONTRACTORS, AND UTILITY CONTRACTORS SHALL ATTEND A
INSPECTING AUTHORITY 48 HOURS IN ADVANCE OF COVERING UP ANY PHASE OF
ATMS
atms
ATMS CABLE
Z
a0
=
PRE -CONSTRUCTION CONFERENCE PRIOR TO START OF WORK.
CONSTRUCTION REQUIRING OBSERVATION.
GUY
GUY
GUY ANCHOR
w41
j
3. ANY WORK IN THE PUBLIC RIGHT-OF-WAY WILL REQUIRE PERMITS FROM THE APPROPRIATE,
N
tv
CABLE TV LINE
bQ
5. CONTRACTORS SHALL NOTIFY THE APPROPRIATE AGENCY WHEN MATERIALS ARE ON SITE OR
CITY, COUNTY OR STATE AGENCY CONTROLLING THE ROAD AND WITH APPROPRIATE
®
®
POWER TRANSFORMER
W
INSPECTION OF THE WORK IS REQUIRED. NO WORK MAY BEGIN ON ANY PROJECT WITHOUT
INSPECTIONS.
C
c
COMMUNICATIONS LINE
TRANS
TRANS
b
= L
TWENTY FOUR (24) HOUR PRIOR NOTICE.
®
®
TRAFFIC SIGNAL CABINET
r^
O W
W
1.3 COORDINATION & VERIFICATION
Fo
fo
FIBER-OPTIC CABLE
=
6. CONTACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR 48 HOURS PRIOR TO THE REQUIRED
1. ALL DIMENSIONS, GRADES &UTILITY DESIGNS SHOWN ON THE PLANS SHALL BE VERIFIED BY
LIGHT POLE
N
V °bA
TESTING. THE CONTRACTOR MAY NOT OPEN OR CLOSE WATER VALVES.
THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY
F
f
FIRE LINE
-a
W
,d,
_
ARCHITECT/ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH CONSTRUCTION
❑TR
❑TR
TELEPHONE RISER
b
r'n
= W
FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE
IBB
im
IRRIGATION LINE
°�
7. ALL MATERIAL FURNISHED ON, OR FOR THE PROJECT MUST MEET THE MINIMUM REQUIREMENTS
CONTRACTOR FOR WORK HAVING TO BE REDONE DUE TO DIMENSIONS OR GRADES SHOWN
T
T
TELEPHONE MANHOLE
E
m
L
OF THE APPROVING AGENCIES. AT THE REQUEST OF THE APPROVING AGENCY OR THE DESIGN
INCORRECTLY ON THESE PLANS, IF NOT VERIFIED AND NOTIFICATION OF CONFLICTS HAVE NOT
G
9
NATURAL GAS LINE
0
;
N =
ENGINEER, CONTRACTORS SHALL FURNISH PROOF THAT ALL MATERIALS INSTALLED THIS
BEEN BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER.
®
®
TRAFFIC SIGNAL BOX
. ■
V
0
"m
= �+
U
PROJECT MEET THE SPECIFICATION REQUIREMENTS SET FORTH IN GENERAL CONSTRUCTION
2. CONTRACTOR MUST VERIFY ALL EXISTING CONDITIONS BEFORE BIDDING AND BRING UP ANY
OHc
ohc
OVERHEAD COMMUNICATIONS
rL
a00
NOTE N0. 1.
QUESTIONS BEFOREHAND. NO ALLOWANCE WILL BE MADE FOR DISCREPANCIES OR OMISSIONS
WATER MANHOLE
_
THAT CAN BE EASILY OBSERVED.
OHP
ohp
OVERHEAD POWER LINE
m
41
11J N
8. WORK SUBJECT TO APPROVAL BY ANY GOVERNMENTAL AGENCY MUST BE APPROVED PRIOR TO
3. CONTRACTOR TO COORDINATE WITH ALL OTHER DISCIPLINES, INCLUDING BUT NOT LIMITED T0:
®
®
WATER VALVE
rn
°>
(A) BACKFILLING TRENCHES FOR PIPE; (B) PLACING OF AGGREGATE BASE; (C) PLACING OF
LANDSCAPE PLANS, SITE ELECTRICAL SITE LIGHTING PLANS AND ELECTRICAL SERVICE TO THE
OHT
oht
OVERHEAD TELEPHONE LINE
CONCRETE; (D) PLACING OF ASPHALT PAVING.
BUILDING(S), MECHANICAL PLANS FOR LOCATION OF SERVICES TO THE BUILDING(S), INCLUDING
®
®
WATER METER
0
V
FIRE PROTECTION, ARCHITECTURAL SITE PLAN FOR DIMENSIONS, ACCESSIBLE ROUTES, ETC.,
OHTV
ohty
OVERHEAD TELEVISION LINE
1
FIRE HYDRANT
9. INSPECTION, APPROVAL AND FINAL ACCEPTANCE OF ALL WATER AND SEWER CONSTRUCTION
NOT SHOWN ON CIVIL PLANS.
SHALL BE BY THE PUBLIC WORKS DEPARTMENT, AND THEIR DECISION SHALL BE FINAL. SUCH
4. CONTRACTOR IS TO COORDINATE LOCATION OF NEW TELEPHONE SERVICE, GAS SERVICE,
P
P
POWER LINE
9
SANITARY SEWER MANHOLE
i
m
INSPECTIONS SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF
CABLE, ETC. TO BUILDING WITH THE APPROPRIATE UTILITY COMPANY. FOR TELEPHONE,
PERFORMING THE WORK IN AN ACCEPTABLE MANNER IN ACCORDANCE WITH THE DEQ/QLPE
CONTRACTOR TO FURNISH CONDUIT, PLYWOOD BACKBOARD, AND GROUND WIRE, AS REQUIRED.
PIC
Plc
POWER/COMMUNICATIONS LINE
APPROVED CONSTRUCTION PLANS.
0SSCO �SSCO SANITARY SEWER CLEANOUT
Prt pft POWERRELEPHONE LINE
1.4 SAFETY AND PROTECTION
®
®
STORM DRAIN MANHOLE
10. ANY DEVIATION FROM THE APPROVED PLANS AND SPECIFICATIONS MUST HAVE THE APPLICABLE
1. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION,
Prt/C
p/Uc
POWER/TELEICOMMLZNE
[ONA
L P
N
AGENCY APPROVAL IN WRITING PRIOR TO CONSTRUCTION.
2. CONTRACTOR IS RESPONSIBLE FOR THE SAFETY OF THE PROJECT AND SHALL MEET ALL OSHA
REQUIREMENTS.
®
®
STORM DRAIN CURB INLET
cgs G\$T f
3. CONTRACTOR IS RESPONSIBLE FOR CONFORMING TO LOCAL AND FEDERAL CODES GOVERNING
RD
rd
ROOF DRAIN LINE
11. PRIOR TO BEGINNING INSTALLATION OF STREET LIGHTS, THE ELECTRICAL CONTRACTOR SHALL
®
®
STORM DRAIN CATCH BASIN
OBTAIN AN ELECTRICAL PERMIT FROM THE BUILDING DIVISION OF THE MERIDIAN PUBLIC WORKS
SHORING AND BRACING OF EXCAVATIONS AND TRENCHES , AND FOR THE PROTECTION OR
SW
sw
SECONDARY WATER LINE
DEPARTMENT. ANY DEVIATION IN STREET LIGHT LOCATIONS FROM THE APPROVED PLANS MUST
WORKERS AND PUBLIC.
4. CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT ALL EXISTING PUBLIC AND
®D
®
STORM DRAIN CLEANOUT
BE APPROVED IN WRITING FROM THE CITY ENGINEER.
PRIVATE PROPERTY, ROADWAYS, AND UTILITY IMPROVEMENTS. DAMAGE TO EXISTING
S
s
SANITARY SEWER LINE
STORM DRAIN COMBO BOX
P
WATER
IMPROVEMENTS CAUSED BY THE CONTRACTOR MUST BE REPAIRED BY THE CONTRACTOR AT
ST
st
STEAM LINE
G
HIS/HER EXPENSE TO THE SATISFACTION OF THE OWNER OF SAID IMPROVEMENTS.
MB
MB
MAILBOX
1. CONSTRUCTION OF THE WATER SYSTEM SHALL CONFORM TO THE STANDARDS IN THE "IDAHO
5. CONTRACTOR IS REQUIRED TO KEEP ALL CONSTRUCTION ACTIVITIES WITHIN THE APPROVED
SD
sd
STORM DRAIN LINE
RULES FOR PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08)" AS WELL AS THE STANDARDS
PROJECT LIMITS. THIS INCLUDES, BUT IS NOT LIMITED TO, VEHICLE AND EQUIPMENT STAGING,
SIGN
AND SPECIFICATIONS REFERRED TO IN GENERAL CONSTRUCTION NOTE NO. 1. MATERIAL STORAGE AND LIMITS OF TRENCH EXCAVATION.
T t TELEPHONE LINE
6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN PERMISSION AND/OR EASEMENTS FROM
o-
o-
FLOW DIRECTION
2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON -POTABLE WATER MAINS
THE APPROPRIATE GOVERNMENT AGENCY AND/OR INDIVIDUAL PROPERTY OWNER(S) FOR
T/C
tic
TELEPHONE/COMM LINE
(SANITARY SEWER, STORM DRAIN, AND IRRIGATION) SHALL BE A MINIMUM OF TEN (10) FEET.
WORK OR STAGING OUTSIDE OF THE PROJECT LIMITS.
44.00
44.00
WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON -POTABLE WATER MAIN TO
7. CONTRACTOR SHALL PROVIDE BARRICADES, SIGNS, FLASHERS, OTHER EQUIPMENT AND FLAG
UD
ud
UNDERDRAIN
TOC
EX TOG
SPOT ELEVATION
CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL SEPARATION, THE CROSSING
PERSONS NECESSARY TO INSURE THE SAFETY OF WORKERS AND VISITORS. ALL
o
SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR
PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE WASTEWATER
CONSTRUCTION SIGNING, BARRICADING, AND TRAFFIC DELINEATION SHALL CONFORM TO THE
"MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES", LATEST EDITION.
UGC
u9c
UNDERGROUND COMMUNICATIONS
CONIFEROUS TREE
m
RULES (IDAPA 58.01.16).
8. CONTRACTOR SHALL COMPLY WITH LOCAL NOISE ORDINANCE STANDARDS.
UGP
ugp
UNDERGROUND POWER LINE
LIj
9. CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL ACCORDING TO GOVERNING AGENCY
3. THE HORIZONTAL SEPARATION OF NON -POTABLE SERVICES AND POTABLE WATER SERVICES OR
POTABLE WATER MAINS SHALL BE A MINIMUM OF SIX (6) FEET. WHERE IT IS NECESSARY FOR A
STANDARDS.
10. CONTRACTOR SHALL TAKE ALL NECESSARY AND PROPER PRECAUTIONS TO PROTECT
UGT
ugt
UNDERGROUND TELEPHONE
LINE
DECIDUOUS TREE
74
W
ADJACENT PROPERTIES FROM ANY AND ALL DAMAGE THAT MAY OCCUR FROM STORM WATER
UGry
ugty
UNDERGROUND TELEVISION
POTABLE WATER MAIN AND NON -POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN
RUNOFF AND/OR DEPOSITION OF DEBRIS RESULTING FROM ANY AND ALL WORK IN CONNECTION
z
(18) INCHES OF VERTICAL SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN
WITH CONSTRUCTION. SUBMIT A STORM WATER POLLUTION PREVENTION PLAN, IF REQUIRED.
W
w
WATER LINE
Q
ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER
11. WORK IN PUBLIC STREETS, ONCE BEGUN, SHALL BE PROSECUTED TO COMPLETION WITHOUT
Q
SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16).
DELAY AS TO PROVIDE MINIMUM INCONVENIENCE TO ADJACENT PROPERTY OWNERS AND TO
[l2[- -�
- _ _4512-
- CONTOUR LINE
THE TRAVELING PUBLIC.
Z
4. PLACE WATER SERVICE LINES IN A TWO (2) INCH DIAMETER PIPE SLEEVE WHEREVER THE
12. CONTRACTOR SHALL PROVIDE ALL NECESSARY HORIZONTAL AND VERTICAL TRANSITIONS
CURB & GUTTER (STD)
SERVICE LINE CROSSES A STORM WATER TREATMENT FACILITY (I.E. SEEPAGE BEDS, DRAINAGE
SWALES).
BETWEEN NEW CONSTRUCTION AND EXISTING SURFACES TO PROVIDE FOR PROPER DRAINAGE
AND FOR INGRESS AND EGRESS TO NEW CONSTRUCTION.
13. NATURAL VEGETATION AND SOIL COVER SHALL NOT BE DISTURBED PRIOR TO ACTUAL
CURB & GUTTER (OUTFALL)
r
d
=
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONTINUOUS WATER SERVICE TO
CONSTRUCTION OF A REQUIRED FACILITY OR IMPROVEMENT. MASS CLEARING OF THE SITE IN
O
Lei
ALL EXISTING WATER USERS AFFECTED BY CONSTRUCTION. IF WATER SERVICE MUST BE
ANTICIPATION OF CONSTRUCTION SHALL BE AVOIDED. CONSTRUCTION TRAFFIC SHALL BE
J
>- 00 Z
INTERRUPTED, THE CONTRACTOR SHALL COORDINATE WITH THE PUBLIC WORKS INSPECTOR.
LIMITED TO ONE APPROACH TO THE SITE. THE APPROACH SHALL BE DESIGNATED BY THE
OR ING AGENCY.
`
SEWER
14. THEER
SHALL TAKE REASONABLE MEASURE TO PROTECT EXISTING IMPROVEMENTS
0
O 0
FROM DAMAGE AND ALL SUCH IMPROVEMENTS DAMAGED BY THE CONTRACTOR'S OPERATION
1. CONSTRUCTION OF THE SEWER SYSTEM SHALL CONFORM TO THE STANDARDS IN THE
SHALL BE REPAIRED OR RECONSTRUCTED TO THE ENGINEER/OWNER'S SATISFACTION AT THE
WASTEWATER RULES (IDAPA 58.01.16) AS WELL AS THE STANDARDS AND SPECIFICATIONS
REFERRED TO IN GENERAL CONSTRUCTION NOTE NO. 1.
EXPENSE OF THE CONTRACTOR.
rl
V 0 fV
1.5 AMERICAN DISABILITIES ACT
[
Z
2. THE HORIZONTAL SEPARATION OF POTABLE WATER MAINS AND NON -POTABLE WATER MAINS
1. PEDESTRIAN / ADA ROUTES SHALL MEET THE FOLLOWING SPECIFICATIONS:
\/
> O
(SANITARY SEWER, STORM DRAIN, AND IRRIGATION) SHALL BE A MINIMUM OF TEN (10) FEET.
'ROUTES SHALL HAVE A 2.08%(1:48) MAXIMUM CROSS SLOPE.
WHERE IT IS NECESSARY FOR A POTABLE WATER MAIN AND NON -POTABLE WATER MAIN TO
*ROUTES SHALL HAVE A 5.00%(1:20) MAXIMUM RUNNING SLOPE.
Q V
CROSS WITH LESS THAN EIGHTEEN (18) INCHES OF VERTICAL SEPARATION, THE CROSSING
SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR
*RAMPS SHALL HAVE A 8.33%(1:12) MAXIMUM RUNNING SLOPE.
2. ADA PARKING STALLS AND ADJACENT ROUTES SHALL HAVE A 2.08% (1:48) MAXIMUM SURFACE
W
V / Q N
PUBLIC DRINKING WATER SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE WASTEWATER
58.01.16).
SLOPE IN ANY DIRECTION.
3. THE CONTRACTOR SHALL ADHERE TO THE ABOVE SPECIFICATIONS. IN THE EVENT OF
ILL.
DISCREPANCY
DISCREPANCY IN THE CONSTRUCTION DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE
W w O
3. THE HORIZONTAL SEPARATION OF NON -POTABLE SERVICES AND POTABLE WATER SERVICES OR
ARCHITFCT/ENGINEER PRIOR TO ANY CONSTRUCTION.
Q
W
POTABLE WATER MAINS SHALL BE A MINIMUM OF SIX (6) FEET. WHERE IT IS NECESSARY FOR A
O
POTABLE WATER MAIN AND NON -POTABLE WATER MAIN TO CROSS WITH LESS THAN EIGHTEEN
L
(18) INCHES OF VERTICAL SEPARATION, THE CROSSING SHALL BE CONSTRUCTED IN
N
ACCORDANCE WITH SECTION 542.07 OF THE IDAHO RULES FOR PUBLIC DRINKING WATER
SYSTEMS (IDAPA 58.01.08) AND SECTION 430.02 OF THE WASTEWATER RULES (IDAPA 58.01.16).
H
M W
4. PLACE SEWER SERVICE LINES IN A SIX (6) INCH DIAMETER WATER CLASS PIPE SLEEVE
WHEREVER THE SERVICE LINE CROSSES A STORM WATER TREATMENT FACILITY (I.E., SEEPAGE
Z
BEDS, DRAINAGE SWALES).
ROADWAY
W
1. ALL CONTRACTORS WORKING WITHIN THE PUBLIC ROAD RIGHT-OF-WAY ARE REQUIRED TO
SECURE A RIGHT-OF-WAY CONSTRUCTION PERMIT FROM ACHD OR ITO AT LEAST TWENTY-FOUR
Q
(24) HOURS PRIOR TO ANY CONSTRUCTION.
a
2. ACHD OR ITD WILL INSPECT ALL WORK WITHIN THE PUBLIC RIGHTS -OF -WAY TO INCLUDE UTILITY
0
_
I
TRENCHES ABOVE THE PIPE ZONE.
N
PRESSURIZED IRRIGATION
1. THE PRESSURIZED IRRIGATION SYSTEM MUST BE BUILT TO THE STANDARDS OF THE IRRIGATION
DISTRICT IN WHICH IT IS BEING CONSTRUCTED.
2. INSTALL A REDUCED PRESSURE BACKFLOW PREVENTER IN ANY CONNECTION BETWEEN THE
POTABLE WATER SYSTEM AND THE PRESSURE IRRIGATION SYSTEM. THE DEVICE MUST BE
APPROVED BY THE IDAHO DEPARTMENT OF ENVIRONMENTAL QUALITY (DEQ) AND THE CITY OF
ABBREVIATIONS
O
MERIDIAN WATER DEPARTMENT.
N
(_
Z
a
a
DRAINAGE
AC
ADA
ACRE
AMERICANS WITH DISABILITIES ACT
DIP
DTREE
DUCTILE IRON PIPE
DECIDUOUS TREE
GM
GMH
GAS METER
GAS MANHOLE
FCC
PI
POINT OF COMPOUND CURVE
POINT OF INTERSECTION
T
TBC
TOWNSHIP
TOP BACK OF CURB
Q
w
U
FOR COMMERCIAL SUBDIVISIONS OR COMMERCIAL PROJECTS WITH PUBLIC MAINS THAT HAVE
ATMS
ADVANCED TRAFFIC MGMT. SYSTEM
DYL
DOUBLE YELLOW LINE
GUY
GUY WIRE
PM
PARKING METER
TELE
TELEPHONE
W
G
ON -SITE DRAINAGE.
B&C
BAR & CAP
E
EAST
GV
GAS VALVE
PP
POWER POLE
TFC
TOP FACE OF CURB
N
o�
BC
BUILDING CORNER
EB
ELECTRIC BOX
HOPE
HIGH DENSITY POLYETHYLENE
PRC
POINT OF REVERSE CURVE
TFG
TOP FINISH GRADE
>
1. FOR ANY DRAINAGE FACILITIES WITHIN A PUBLIC RIGHT OF WAY, ACHD OR ITD SHALL BE
BFG
BOTTOM FINISH GRADE
EGL
ENERGY GRADE LINE
HG
HEADGATE
PRK
PARKING STRIPE
TL
TREE LINE
W
v
RESPONSIBLE FOR INSPECTION. FOR ANY PRIVATE DRAINAGE FACILITIES THE PROJECT
BLUE
BLUE STAKED ELECTRIC
ELEV
ELEVATION
HGL
HYDRAULIC GRADE LINE
POC
POINT OF CONNECTION
TMH
TELEPHONE MANHOLE
ENGINEER OR ARCHITECT SHALL BE RESPONSIBLE FOR INSPECTION AND CERTIFICATION OF
BLUFO
BLUE STAKED FIBER OPTIC
EM
ELECTRIC METER
HP
HIGH POINT
PT
POINT OF TANGENCY
TOA
TOP OF ASPHALT
�I
DRAINAGE FACILITIES; HOWEVER ANY ROOF DRAINAGE AND PIPING TO THE DRAINAGE
BLUG
BLUE STAKED NATURAL GAS
EMH
ELECTRIC MANHOLE
HW
HEADWALL or HIGH WATER
PWR
POWER
TOC
TOP OF CONCRETE
FACILITIES WILL BE INSPECTED BY THE MERIDIAN PLUMBING OFFICIAL UNDER THE APPROPRIATE
BLUIRR
BLUE STAKED IRRIGATION
EOA
EDGE OF ASPHALT
HWY
HIGHWAY
PVC
POLYVINYL CHLORIDE PIPE
TOF
TOP OF FOOTING
W
=
PERMIT.
BLUSD
BLUE STAKED STORM DRAIN
EOC
EDGE OF CONCRETE
ICO
IRRIGATION CLEANOUT
R
RANGE
TOG
TOP OF GRATE
Q
a
BLUSS
BLUE STAKED SANITARY SEWER
EOG
EDGE OF GRAVEL
ICV
IRRIGATION CONTROL VALVE
RCP
REINFORCED CONCRETE PIPE
TOE
TOE OF SLOPE
G
BLUFF
BLUE STAKED TELEPHONE
EOL
EDGE OF LAWN
IE
INVERT ELEVATION
RD
ROOF DRAIN
TOP
TOP OF SLOPE or TOP OF PIPE
W
a
BLUW BLUE STAKED WATER EX or EXIST EXISTING IRR IRRIGATION REV REVISION TOW TOP OF WALL
d
BM
BENCHMARK
F
FIRE
LF
LINEAR FEET
ROW
RIGHT-OF-WAY
TR
TELEPHONE RISER
1Y
a
a
a
a
a
a
i
BOF
BOTTOM OF FOOTING
FC
FOUNDATION CORNER
LIP
LIP OF GUTTER
RR
RAILROAD
TV
TELEVISION
PROJECT NO: 21070
BOB BOTTOM OF BOX FD FOUND or FOUNDATION DRAIN LP LOW POINT or LIGHT POLE S SOUTH TW FINISH GRADE AT TOP OF WALL
9
BOIL
BOLLARD
FDC
FIRE DEPT. CONNECTION
MAX
MAXIMUM
SAD
SEE ARCHITECTURAL DRAWINGS
TRANS
TRANSFORMER
DRAWN BY: CCW
BOT BOTTOM FDMN FOUND MONUMENT MIN MINIMUM SD STORM DRAIN TSP TRAFFIC SIGNAL POLE
o
BOV
BLOW -OFF VALVE
FDSC
FOUND SECTION CORNER
MON
MONUMENT
SDCB
STORM DRAIN CATCH BASIN
TSB
TRAFFIC SIGNAL BOX
CHECKED BY: RJP
BOW
BACK OF WALK
FFE
FINISHED FLOOR ELEVATION
MP
METAL PIPE
SDCO
STORM DRAIN CLEOUNOUT BOX
LID
UNDERDRAIN
BW
FINISH GRADE AT BOTTOM OF WALL
FG
FINISHED GRADE
MW
MONITORING WELL
SDMH
STORM DRAIN MANHOLE
UGC
UNDERGROUND COMMUNICATIONS
DATE: FEBRUARY
7, 2022
o
FL
CENTERLINE
FH
FIRE HYDRANT
N
NORTH
SEC
SECTION
UGP
UNDERGROUND POWER
rr
�?
CAN CABLE TELEVISION FL FLOW LINE NG NATURAL GROUND SPECS SPECIFICATIONS UGT UNDERGROUND TELEPHONE
CBR
CONCRETE BARRIER
FNC
FENCE
NGRET NG AT RETAINING WALL
SLB&M
SALT LAKE BASE & MERIDIAN
UGTV
UNDERGROUND TELEVISION
FNCCL CHAIN LINK FENCE NR NAIL & RIBBON SO SQUARE U.N.O. UNLESS NOTED OTHERWISE
cc CURB T
COL
COLUMN
FNCIRN
IRON FENCE
NW
NAIL & WASHER
SOFT
SQUARE FEET
UP
UTILITY POLE
GENERAL
NOTES,
COMM
COMMUNICATIONS
FNCVYL
VINYL FENCE
NTS
NOT TO SCALE
SQYD
SQUARE YARD
VCP
VITRIFIED CLAY PIPE
CONC
CONCRETE
FNCWD
WOOD FENCE
OG
ORIGINAL GROUND
SS
SANITARY SEWER
VP
VERTICAL PIPE
LEGEND
A N D
i
CONST
CONSTRUCTION
FNCWR
WIRE FENCE
OH
OVERHANG
SSCO
SANITARY SEWER CLEANOUT
W
WEST or WATER
`
CMP
CORRUGATED METAL PIPE
FO
FIBER OPTIC
OHC
OVERHEAD COMMUNICATIONS
SSMH
SANITARY SEWER MANHOLE
WM
WATER METER
ABBREVIATIONS
CP
CONTROL POINT
FOW
FRONT OF WALK
OHP
OVERHEAD POWER
ST
STEAM
WMH
WATER MANHOLE
CTREE
CONIFEROUS TREE
FT
FEET
OHT
OVERHEAD TELEPHONE
STA
STATION
WS
WATER SURFACE
CUFF CUBIC FOOT G NATURAL GAS OHTV OVERHEAD TELEVISION STD STANDARD WTR WATER
CUYD
CUBIC YARD
GAR
GARAGE
R
PROPERTY LINE
STM
STORM
WV
WATER VALVE
DEL
DELINEATOR
GB
GRADE BREAK
PB
POWER BOX
SYL
SOLID YELLOW LINE
WW
WATERWAY
DIA or 0
DIAMETER
GL
GROUND LIGHT
PC
POINT OF CURVATURE
SWL
SOLID WHITE LINE
•