HomeMy WebLinkAboutElevations V1aERIDIA y_
APPROVED
U or o�2z
rux a=�
a
M
M
(V
(V
O
N
O
HIGH PAR.
122'-0"
LOW PAR)
120'-0"
B.O. C
110'-0'
LEVEL 1
1' 100'-0"
EAST ELEVATION
1/4" = V-0"
1/4" PER. FT. V EXTERIOR FINISH
MINIMUM SLOPE �� MATERIAL
PER CODE
J. R. SMITH 1770-4 NB
DOWNSPOUT NOZZLE
INSTALL PER MFR.
CD
CD
j
CAULK ALL AROUND O
7DISCHARGE NOZZLE
FROM ROOF DRAIN
SEE MECH. & PLUMBING PLANS
OVERFLOW DISCHARGE NOZZLE
I
GENERAL NOTES: ELEVATIONS
1. ALL DIMENSIONS ARE TO EXTERIOR FACE -OF -STUD (F.O.S.) UNLESS NOTED OTHERWISE
2. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN
3. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF
COLUMNS, BEAMS, SHEAR WALLS, ETC.
4. CONTRACTOR SHALL VERIFY THAT ALL GRADES SLOPE AWAY FROM BUILDING. GRADE SHALL SLOPE
6" MIN. IN FIRST 10'-0" AS PER IBC.
5. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE
6. PROVIDE WALL BLOCKING CAPABLE OF RESISTING VERTICAL & LATERAL LOADS W/ A SAFETY FACTOR
OF 2 FOR ALL EXTERIOR TENANT FURNISHED ITEMS. COORDINATE NECESSARY LOCATIONS W/ TI
DRAWINGS PRIOR TO CLOSING EXTERIOR WALLS
7. COORDINATE ALL ROUGH -IN WALL COUNDUITS, PLUMBING, & BLOCKING W/ TI DRAWINGS PRIOR TO
CLOSING WALLS
KEYNOTES: ELEVATIONS
OVERIFY LOCATION OF DOOR W/ T.I. DRAWINGS PRIOR TO FRAMING
O2 ELECTRICAL METER - TYP.
OROOFTOP ACCESS LADDER (FIXED ALUMINUM CHANNEL) w/ LOCKABLE ACCESS.
VERIFY LOCATION w/ TENANT PRIOR TO INSTALATION
O4 VERIFY LOCATION OF WINDOWS AND STOREFRONTS WITH TENANT
OCANOPY TO BE METAL TYPE GALVALUME MINIMUM 22-GAUGE STEEL IN
CONFORMANCE WITH ASTM A792 AZ50
OCOW TONGUE - ROOF LEADER OVERFLOW. SEE DETAIL 5 / A201
OFURRING STRIPS COVERED BY METAL SOFFIT TO MATCH CANOPY
MATERIAL LEGEND: ELEVATIONS
HATCH PATTERN DESCRIPTION
METAL TRIM
SHERWIN WILLIAMS - IRON ORE SW 7069
6" FIBER CEMENT LAP PANELS.
KNOTWOOD-CHARCOAL ASH
FIBER CEMENT BOARD & BATT SIDING WITH 1 1/2" BATTS AT 12" O.C.
SHERWIN WILLIAMS - PEPPERCORN SW 7674
1 1/2" EIFS
GLAZING CALCULATIONS
TOTAL FACADE SF
TOTAL GLAZING SF
PERCENTAGE
NORTH ELEVAITON
1,481 SF
466 SF
31
EAST ELEVAITON
831 SF
233 SF
28
SOUTH ELEVAITON
1,518 SF
540 SF
36
WEST ELEVAITON
811 SF
280 SF
35
"LMnt
ARCHITECTURE
Architecture
Landscape Architecture
Land Planning
Interior Design
Construction Management
HEED Consulting
9672 South 700 East Suite 203
Sandy Utah 84070
ph. 801.987.3911
www.Imntarch.com
The designs shown and described
within these documents, including all
technical drawings, graphic
representation & models, are
proprietary & can not be copied,
duplicated in whole or in part without
the express written permission from
LMnt Architecture.
SEAL:
Not for
constrgctlO
z
0
Q
m
�
�Q0
I
I
}�
L
CO
O
�
Q
>
Y
U
cn Z
wo
m
O ry
W
O
m 75
Q U)
project no:
21022
date:
22.06.30
revisions:
Schematic Design
sheet:
EXTERIOR
ELEVATIONS
A201
SHEET SIZE: 24" x 36"
GENERAL NOTES: ELEVATIONS
aVl
APPROVED
U or o�2z
ruxtn:a=�
WEST ELEVATION
1/4" =1'-0"
HIGH PARAPET
122'-U'
LOW PARAPET
Y 12o'-a'
y B.O. CANOPY
Y 110'-0"
11
M
(V
(V
O
N
LEVEL 1
1. ALL DIMENSIONS ARE TO EXTERIOR FACE -OF -STUD (F.O.S.) UNLESS NOTED OTHERWISE
2. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN
3. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF
COLUMNS, BEAMS, SHEAR WALLS, ETC.
4. CONTRACTOR SHALL VERIFY THAT ALL GRADES SLOPE AWAY FROM BUILDING. GRADE SHALL SLOPE
6" MIN. IN FIRST 10'-0" AS PER IBC.
5. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE
6. PROVIDE WALL BLOCKING CAPABLE OF RESISTING VERTICAL & LATERAL LOADS W/ A SAFETY FACTOR
OF 2 FOR ALL EXTERIOR TENANT FURNISHED ITEMS. COORDINATE NECESSARY LOCATIONS W/ TI
DRAWINGS PRIOR TO CLOSING EXTERIOR WALLS
7. COORDINATE ALL ROUGH -IN WALL COUNDUITS, PLUMBING, & BLOCKING W/ TI DRAWINGS PRIOR TO
CLOSING WALLS
KEYNOTES: ELEVATIONS
OVERIFY LOCATION OF DOOR W/ T.I. DRAWINGS PRIOR TO FRAMING
OELECTRICAL METER - TYP.
OROOFTOP ACCESS LADDER (FIXED ALUMINUM CHANNEL) w/ LOCKABLE ACCESS.
VERIFY LOCATION w/ TENANT PRIOR TO INSTALATION
OVERIFY LOCATION OF WINDOWS AND STOREFRONTS WITH TENANT
OCANOPY TO BE METAL TYPE GALVALUME MINIMUM 22-GAUGE STEEL IN
CONFORMANCE WITH ASTM A792 AZ50
OCOW TONGUE - ROOF LEADER OVERFLOW. SEE DETAIL 5 / A201
OFURRING STRIPS COVERED BY METAL SOFFIT TO MATCH CANOPY
MATERIAL LEGEND: ELEVATIONS
HATCH PATTERN DESCRIPTION
METAL TRIM
SHERWIN WILLIAMS - IRON ORE SW 7069
6" FIBER CEMENT LAP PANELS.
KNOTWOOD-CHARCOAL ASH
FIBER CEMENT BOARD & BATT SIDING WITH 1 1/2" BAITS AT 12" O.C.
SHERWIN WILLIAMS - PEPPERCORN SW 7674
1 1/2" EIFS
GLAZING CALCULATIONS
TOTAL FACADE SF
TOTAL GLAZING SF
PERCENTAGE
NORTH ELEVAITON
1,481 SF
466 SF
31
EAST ELEVAITON
831 SF
233 SF
28
SOUTH ELEVAITON
1,518 SF
540 SF
36
WEST ELEVAITON
811 SF
280 SF
35
" LMnt
ARCHITECTURE
Architecture
Landscape Architecture
Land Planning
Interior Design
Construction Management
LEED Consulting
9672 South 700 East Suite 203
Sandy Utah 84070
ph. 801.987.3911
www.lmntarch.00m
The designs shown and described
within these documents, including all
technical drawings, graphic
representation & models, are
proprietary & can not be copied,
duplicated in whole or in part without
the express written permission from
LMnt Architecture.
SEAL:
Not for
constfgcfio
z
0
Q
m
�
�Q0
I
I
} �
� E
CO
O
�
Q
>
Y
U
�z
U)
wo
m
O ry
W
U)
project no:
21022
date:
22.06.30
revisions:
Schematic Design
sheet:
EXTERIOR
ELEVATIONS
A202
0
a
NORTH ELEVATION
1/4" =1'-0"
SHEET SIZE: 24" x 36"