Loading...
HomeMy WebLinkAbout122008 CZC C1.00 Site Plan V11 2 2 2 2 3 4 5 6 8 9 10 7 7 7 8 8 8 11 12 14 13 9 EXISTING SEEPAGE BED (PREVIOUSLY SIZED TO INCLUDE SITE DRAINAGE) EXISTING CATCH BASIN CONNECT TO EXISTING SANITARY SEWER SERVICE STUB 12 EXISTING SANITARY SEWER SERVICE STUB TO BE ABANDONED EXISTING 8" WATER MAIN EXISTING 8" SANITARY SEWER MAIN EXISTING 8" WATER MAIN 13 EXISTINGPARKING SITE PARKING EXISTING SITE 16 8888 17 PROPOSED ROOF STORM SYSTEM (SWALE) CONNECT TO EXISTING WATER METER 5' 27' 18' 9' 9' 12'9' 12' 12' R16' R30' R12' R12' R4' R8' R4' R12' File Location: g:\2022\122008\cad\_czc\122008 czc c1.00 site plan.dwg Last Plotted By: jason densmer Date Plotted: Wednesday, June 15 2022 at 05:15 PM C1.50 Site Details CONSTRUCTION NOT FOR 2 Bike Rack Scale: NTS 1. HOOP RACK IN STAINLESS STEEL FINISH BY DERO OR APPROVED EQUAL. 2. SURFACE MOUNT PER MANUFACTURER'S SPECIFICATIONS. 3. SPACING REQUIREMENTS PER MANUFACTURER'S SPECIFICATIONS. 6' 12'-8" 12'-8" 1' (TYP.) 6' LATCH STRUCTURAL 'B' DECK FULLY WELDED TO TUBE FRAME. PAINT TWO COATS, COLOR PER OWNER. STUCCO FINISH OVER CMU. COLOR PER OWNER. 3-HEAVY DUTY HINGES PER GATE COMMERCIAL GRADE DROP BOLT WITH PADLOCK AND SLEEVE EMBEDDED IN CONCRETE 5' x 5'-8" GATE (TYP. OF 2) GATE POST SEE DETAIL SLOPE 2% TRASH SLOPE 2% PRECAST CONCRETE CURB DOWELED TO SLAB (TYP. OF 3) TYPICAL WALL SECTION NTS STUCCO, COLOR PER OWNER CONCRETE CAP BOND BEAM WITH (1) #5 (1) #5 AT 4' O.C. 8" SMOOTH-FACE CMU GROUT SOLID SEALANT OVER 1/2" PERFORMED EXPANSION JOINT FILLER PRECAST CONCRETE CURB DOWELED TO SLAB 4" CONCRETE SLAB 4" GRAVEL (2) #5 TOP AND BOTTOM 3' Material Legend: Keynotes: Project Information: Project Calculations: Zoning Regulations: Keynotes: 1. EXISTING ACCESS ROAD. RETAIN AND PROTECT. 2. UTILITY STRUCTURE - SEE ELECTRICAL CALLOUT NUMBERS COORDINATED TO NUMBERED NOTES BELOW. Fence Legend: 3' CHAIN LINK FENCE 6' CHAIN LINK FENCE 10' CHAIN LINK FENCE HEAVY DUTY ASPHALT PAVING - SEE DETAIL ?/? . LIGHT DUTY ASPHALT PAVING - SEE DETAIL ?/? . LANDSCAPE AREAS. REFER TO LANDSCAPE SHEET **** FOR MORE INFORMATION. STANDARD CONCRETE FLATWORK - SEE DETAIL ?/? . REINFORCED CONCRETE FLATWORK - SEE DETAIL ?/? . TENNIS COURT ASPHALT SECTION WITH PLEXIPAVE SURFACING - SEE DETAIL ?/? . Material Legend: ROCK MULCH PER SPECIFICATION SECTION XX XX XX . LARGE BASALT BOULDERS, 3'-4' DIA. TYP. SEE DETAIL **** SPEC SECTION ****** EXISTING CHAIN LINK FENCE 5' CHAIN LINK FENCE 4' CHAIN LINK FENCE 8' CHAIN LINK FENCE # CONCRETE UNIT PAVERS AS SPECIFIED PLAYGROUND SURFACING OVER FILTER FABRIC AS SPECIFIED TURF SEED PER SPECIFICATION SECTION XX XX XX . TURF SOD PER SPECIFICATION SECTION XX XX XX . CATCH CURB AND GUTTER, SEE DETAIL ***** . REVERSE CURB AND GUTTER, SEE DETAIL ***** . Curb and Gutter Legend: CALLOUT NUMBERS COORDINATED TO NUMBERED NOTES BELOW. # HEAVY DUTY CONCRETE FLATWORK LANDSCAPE AREA - REFER TO L1.00 FOR ADDITIONAL INFORMATION STANDARD CONCRETE FLATWORK 1. EXISTING SIDEWALK - RETAIN AND PROTECT 2. EXISTING CURB AND/OR GUTTER - RETAIN AND PROTECT 3. EXISTING IRRIGATION VALVE - RETAIN AND PROTECT 4. EXISTING 2" WATER METER - RETAIN AND PROTECT 5. EXISTING FIRE HYDRANT - RETAIN AND PROTECT 6. EXISTING WATER MANHOLE - RETAIN AND PROTECT 7. EXISTING FENCE - RETAIN AND PROTECT 8. EXISTING LANDSCAPE - RETAIN AND PROTECT 9. EXISTING ASPHALT TO REMAIN 10. EXISTING SITE LIGHTING - RELOCATE 11. TRASH ENCLOSURE. SEE DETAIL 1/C1.50. 12. 4-INCH WIDE PAINTED ASPHALT MARKING (WHITE) 13. ADA PEDESTRIAN RAMP 14. PAINTED CROSSWALK STRIPING 15. ACCESSIBLE PARKING STALL AND ACCESS AISLE PER ADA GUIDELINES 16. BICYCLE RACK (2 EACH). SEE DETAIL 2/C1.50. 17. DRIVE-THRU READER BOARD & ORDER SPEAKER PROJECT: PROPOSED COFFEE SHOP APPLICANT, OWNER COMPANY: WHITE-LEASURE DEVELOPMENT COMPANY CONTACT: KEN LENZ ADDRESS: 8385 W. EMERALD ST. BOISE, IDAHO 83704 PHONE: 208.345.1842 CIVIL ENGINEER, LANDSCAPE ARCHITECT, LAND SURVEYOR COMPANY: THE LAND GROUP, INC CONTACT: JASON DENSMER, PE (PROFESSIONAL ENGINEER) CONTACT: MICHAEL THOMAS, PLA (PROFESSIONAL LANDSCAPE ARCHITECT) CONTACT: JAMES R. WASHBURN, PLS (PROFESSIONAL LAND SURVEYOR) ADDRESS: 462 E. SHORE DR., SUITE 100 EAGLE, IDAHO 83616 PHONE: PROPERTY4041 SIZE: 208.939.36,590 SF / ±0.84 ACRES PROPOSED BUILDING SIZE: +/- 1,975 SF / ±0.045 ACRES PARKING CALCULATIONS: REQUIRED PROPOSED PARKING STALLS: 4 (1 STALL PER 500 SF 17 GROSS FLOOR AREA) ACCESSIBLE PARKING STALLS: 1 (1-25 STALLS PROVIDED 1 PER ADA GUIDELINES) BICYCLE PARKING SPACES: 1 (1 SPACE PER 25 2 VEHICULAR PARKING STALLS) PARCEL #: R7877770010 CURRENT/PROPOSED ZONING: C-C FRONT SETBACK: N/A REAR SETBACK: N/A INTERIOR SIDE SETBACK: N/A LANDSCAPE BUFFERS: STREET: (NOT APPLICABLE TO SITE - ALREADY DEVELOPED) RESIDENTIAL USES: 25-FT ASPHALT PAVEMENT 1 2 2 2 2 3 4 5 6 8 9 10 7 7 7 7 8 8 8 8 11 12 14 13 9 EXISTING SEEPAGE BED (PREVIOUSLY SIZED TO INCLUDE SITE DRAINAGE) EXISTING CATCH BASIN CONNECT TO EXISTING SANITARY SEWER SERVICE STUB 12 EXISTING SANITARY SEWER SERVICE STUB TO BE ABANDONED EXISTING 8" WATER MAIN EXISTING 8" SANITARY SEWER MAIN EXISTING 8" WATER MAIN 13 EXISTINGPARKING SITE PARKING EXISTING SITE 16 8888 8 17 PROPOSED ROOF STORM SYSTEM (SWALE) CONNECT TO EXISTING WATER METER 5' 27' 18' 9' 9' 12'9' 12' 12' R16' R30' R12' R12' R4' R8' R4' R12' R10' R22' R8' R4' 12' 14.15' 8.92' 15 SERVICE RAMP 10.5' SEWER SERVICES Pressure Irrigation Note: DOMESTIC WATER WILL BE USED AS THE PRIMARY SOURCE FOR IRRIGATION. REQUIREMENTS TO USE SURFACE IRRIGATION WATER AS PRIMARY IRRIGATION WAIVED BY THE CITY OF MERIDIAN ON OCTOBER 15TH, 2015 (SEE ATTACHED APPROVAL LETTER IN APPLICATION). 07/06/22 A-2022-0134 MAN ACCESS MAN ACCESS SPLIT FACE CMU WALL 1 x 1 STEEL TUBE 2 WELDED x 2 FRAME TO 2 x 2 STL. TUB POST 1" METAL DECKING MECHANICALLY CONNECTED TO FRAME (4) # BARS (SOLID GROUTED CELL) 4" DIA. STEEL BOLLARD FILL W/ CONCRETE HEAVY DUTY HINGES 2 x 2 STL. ANGLE WELDED TO 2 x 2 FRAME 1/2" DIA. THREADED ROD W/ TURNBUCKLE WELDED TO 1-1/2" x 1-1/2" x 1/4" STL. 2"ANGLE x 2" x 3/8" STL. PLATE W/ ROUNDED EDGE, WELD TO 2" SQ. STL. POST. 3 PER POST. PROVIDE HOLES FOR CANE BOLTS PER PLAN 2" 2" 1/2" GATE POST DETAIL 120° MIN 1 Trash Enclosure Layout Scale: NTS 07/06/22 A-2022-0134 R10' R22' R8' R4' 12' 14.15' 8.92' 15 SERVICE RAMP 10.5' SEWER SERVICES Material Legend: Keynotes: Project Information: Project Calculations: Zoning Regulations: CALLOUT NUMBERS COORDINATED TO NUMBERED NOTES BELOW. # HEAVY DUTY CONCRETE FLATWORK LANDSCAPE AREA - REFER TO L1.00 FOR ADDITIONAL INFORMATION STANDARD CONCRETE FLATWORK 1. EXISTING SIDEWALK - RETAIN AND PROTECT 2. EXISTING CURB AND/OR GUTTER - RETAIN AND PROTECT 3. EXISTING IRRIGATION VALVE - RETAIN AND PROTECT 4. EXISTING 2" WATER METER - RETAIN AND PROTECT 5. EXISTING FIRE HYDRANT - RETAIN AND PROTECT 6. EXISTING WATER MANHOLE - RETAIN AND PROTECT 7. EXISTING FENCE - RETAIN AND PROTECT 8. EXISTING LANDSCAPE - RETAIN AND PROTECT 9. EXISTING ASPHALT TO REMAIN 10. EXISTING SITE LIGHTING - RELOCATE 11. TRASH ENCLOSURE. SEE DETAIL 1/C1.50. 12. 4-INCH WIDE PAINTED ASPHALT MARKING (WHITE) 13. ADA PEDESTRIAN RAMP 14. PAINTED CROSSWALK STRIPING 15. ACCESSIBLE PARKING STALL AND ACCESS AISLE PER ADA GUIDELINES 16. BICYCLE RACK (2 EACH). SEE DETAIL 2/C1.50. 17. DRIVE-THRU READER BOARD & ORDER SPEAKER PROJECT: PROPOSED COFFEE SHOP APPLICANT, OWNER COMPANY: WHITE-LEASURE DEVELOPMENT COMPANY CONTACT: KEN LENZ ADDRESS: 8385 W. EMERALD ST. BOISE, IDAHO 83704 PHONE: 208.345.1842 CIVIL ENGINEER, LANDSCAPE ARCHITECT, LAND SURVEYOR COMPANY: THE LAND GROUP, INC CONTACT: JASON DENSMER, PE (PROFESSIONAL ENGINEER) CONTACT: MICHAEL THOMAS, PLA (PROFESSIONAL LANDSCAPE ARCHITECT) CONTACT: JAMES R. WASHBURN, PLS (PROFESSIONAL LAND SURVEYOR) ADDRESS: 462 E. SHORE DR., SUITE 100 EAGLE, IDAHO 83616 PHONE: PROPERTY4041 SIZE: 208.939.36,590 SF / ±0.84 ACRES PROPOSED BUILDING SIZE: +/- 1,975 SF / ±0.045 ACRES PARKING CALCULATIONS: REQUIRED PROPOSED PARKING STALLS: 4 (1 STALL PER 500 SF 17 GROSS FLOOR AREA) ACCESSIBLE PARKING STALLS: 1 (1-25 STALLS PROVIDED 1 PER ADA GUIDELINES) BICYCLE PARKING SPACES: 1 (1 SPACE PER 25 2 VEHICULAR PARKING STALLS) PARCEL #: R7877770010 CURRENT/PROPOSED ZONING: C-C FRONT SETBACK: N/A REAR SETBACK: N/A INTERIOR SIDE SETBACK: N/A LANDSCAPE BUFFERS: STREET: (NOT APPLICABLE TO SITE - ALREADY DEVELOPED) RESIDENTIAL USES: 25-FT ASPHALT PAVEMENT Pressure Irrigation Note: DOMESTIC WATER WILL BE USED AS THE PRIMARY SOURCE FOR IRRIGATION. REQUIREMENTS TO USE SURFACE IRRIGATION WATER AS PRIMARY IRRIGATION WAIVED BY THE CITY OF MERIDIAN ON OCTOBER 15TH, 2015 (SEE ATTACHED APPROVAL LETTER IN APPLICATION). Horizontal Scale: 0 10' 20' 1" = 10' Site Plan File Location: g:\2022\122008\cad\_czc\122008 czc c1.00 site plan.dwg Last Plotted By: jason densmer Date Plotted: Wednesday, June 15 2022 at 05:15 PM C1.00 Site Plan Site Boundary Map: Scale: 1" = 50' CONSTRUCTION NOT FOR 07/06/22 A-2022-0134