Loading...
HomeMy WebLinkAboutBriar Ridge Offsite CONSTRUCTION DRAWINGS V1GENERAL 1. All construction work shall be done in accordance with the current version of the Idaho Standards for Public Works Construction (ISPWC), the City of Meridian Supplemental Specifications to the ISPWC (and any addendums), Meridian Design Standards and the requirements of the Ada County Highway District (ACHD). The more stringent of any of these standards shall be the controlling standards or specifications. 2. The Contractor shall have a copy of the latest City of Meridian Standard Specifications and Drawings on site or readily accessible at all times during construction (available on the website). Failure to have access to a current copy of the Standard Specifications on site could be grounds for a stop work order until the situation is resolved. 3. The Contractor shall have plans stamped "Approved for Construction" by the City of Meridian on site at all times. 4. All Contractors, Subcontractors, and Utility Contractors shall attend a pre -construction conference prior to start of work. 5. Contractors shall notify the appropriate agency when materials are on site or inspection of the work is required. No work may begin on any project without Twenty Four (24) hour prior notice. 6. Contactor shall notify the Public Works Inspector 48 hours prior to the required testing. The Contractor may not open or close water valves. 7. All material furnished on, or for the project must meet the minimum requirements of the approving agencies. At the request of the approving agency or the Design Engineer, Contractors shall furnish proof that all materials installed on this project meet the specification requirements set forth in General Construction Note No. 1. 8. Work subject to approval by any governmental agency must be approved prior to (A) backfilling trenches for pipe; (B) placing of aggregate base; (C) placing of concrete; (D) placing of asphalt paving. 9. Inspection, approval and final acceptance of all water and sewer construction shall be by the Public Works Department, and their decision shall be final. Such inspections shall not relieve the contractor from the responsibility of performing the work in an acceptable manner in accordance with the DEQ/QLPE approved construction plans. 10. Any deviation from the approved plans and specifications must have the applicable agency approval in writing prior to construction. 11. Prior to beginning installation of street lights, the electrical contractor shall obtain an Electrical Permit from the Building Division of the Meridian Public Works Department. Any deviation in street light locations from the approved plans must be approved in writing from the City Engineer. 12. All lot, block street, right-of-way and easement dimensions shall be taken from the final plat of: Briar Ridge Subdivision No. 1. 13. The Contractor shall maintain all existing drainage facilities within the construction area until the drainage improvements are in place and functioning. 14. All Contractors working within the project boundaries are responsible for compliance with all applicable safety laws of any jurisdictional body. The Contractor shall be responsible for all barricades, safety devices and control of traffic within and around the construction area. 15. The locations of existing underground utilities are shown in an approximate way only. The Contractor shall determine the exact location of all existing utilities before commencing work. The Contractor assumes all responsibility for any and all damages caused by his failure to exactly locate and preserve any and all underground utilities. Digline # 1-800-342-1585. 16. All Contractors working within the public road right-of-way are required to secure a right-of-way construction permit from ACHD at least forty-eight (48) hours prior to any construction. 17. Locate subsurface stormwater disposal facilities (including infiltration beds and drywells) at least 25 feet from water mains. This requirement does not apply to catch basins or sand and grease vaults. 18. The Contractor(s) shall remove all obstructions, both above and below ground, as required for the construction of the proposed improvements. This shall include clearing and grubbing which consists of clearing the ground surface of all trees, stumps, brush, undergrowth, hedges, heavy growth of grass or weeds, fences, structures, debris, rubbish, and such material which, in the opinion of the Engineer, is unsuitable for the foundation of pavements. All material not suitable for future use on site shall be disposed of off site. 19. Survey control points which are critical to the construction of the project are located within the limits of work. The Contractor shall take precaution to protect the points in place. 20. All costs of retesting for previously failed tests shall be back charged to the Contractor by the Owner. All costs to the Contractor incurred in correcting deficient work shall be to the Contractors account. Failure to correct such work will be cause for a stop work order and possible termination. 21. The Contractor is to field verify all existing curb & gutter, storm drain, channel crossings, and sewer elevations or inverts prior to construction. When discrepancies occur between plans and specifications, the Contractor shall immediately notify the Engineer. Untimely notification shall negate any Contractors claim for additional compensation. 22. Each Contractor shall be responsible for acquiring any necessary NPDES Permits, filing any NOI's, and preparing a Pollution Prevention Plan (PPP) in accordance with the Environmental Protection Agency. Contact the EPA at 208-378-5746 for the required information. 23. The pipe Contractor shall replace all pavement and concrete removed for the installation of water, sewer, or irrigation pipe. All pavement shall be replaced within seven calendar days from the time the pavement and/or concrete is removed. Concrete and pavement shall be replaced per ISPWC Standards. 24. The Contractor shall field verify all existing curb and gutter, storm drain, channel crossings and all storm drain and sewer elevations or inverts prior to construction and notify the engineer when elevations or inverts do not match plans. ROADWAY 1. All contractors working within the public road right-of-way are required to secure a right-of-way construction permit from ACHD or ITD at least forty-eight (48) hours prior to any construction. 2. ACHD or ITD will inspect all work within the public rights -of -way to include utility trenches above the pipe zone. Contact ACHD Inspection Services at 387-6284. 3. Meridian Public Works will inspect storm drainage improvements serving private roads and parking lot improvements outside the public right-of-way. 4. All construction in the public right-of-way shall conform to the current edition of the ISPWC and the ACHD Supplemental Specifications. No exception to District Policy, Standards, and the ISPWC will be allowed unless specifically and previously approved in writing by the District. 5. Set the tops of all valve boxes and sewer manholes flush with the slope of the finished street grades. The roadway contractor shall install and adjust all spacers, grade rings, manhole rings and lids. 6. Place all water valves, blow -offs and manholes so that they do not conflict with any concrete curb and gutter, valley gutter or sidewalk improvements. 7. Existing A.C. pavement shall be cut to a neat straight line (2' minimum cutback) parallel or perpendicular to the street centerline and the exposed edge shall be tacked with emulsion prior to paving. Actual field conditions during trenching may require additional pavement repair beyond the limits shown on the plans. Refer to conditions listed in the ACHD Policy Manual. 8. All water meters are to be located outside of the public right-of-way. All fire hydrants are to be located within the road right-of-way. There must be at least a one (1) foot separation between the back of sidewalk (or curb if no sidewalk) and the leading edge of any fire hydrant. 9. Over excavation and additional granular backfill may be required in high groundwater areas which are to be determined by the field inspector. 10.All materials placed as fill or backfill shall be placed and compacted in accordance with Section 306 of the current edition of ACHD Supplemental Specifications. 11.Roodwoy construction will meet specific details and requirements of the following Idaho Standards for Public Works Construction Standard Drawings (Current Edition): 1. Street Section, ACHD SD-801 and sections as shown on Street Details Sheet 2. Asphalt repair for street cuts: SD-301, ACHD SD-303, ACHD SD-806. 3. 4.0' Concrete Valley Gutter, ACHD SD-708 4. Rolled Curb and Gutter, ACHD SD-702 5. Pedestrian Ramp for Handicapped, SD-712C, SD 712G 6. Tactile warning surface (TWS) colored a standard color of yellow as per ACHD SD-712 7. Sidewalks, ACHD Supplemental Drawing SD-709 8. Not Utilized 9. Standard Drop Inlet Type IV w/ 12" Sump, ACHD Supplemental SD-604A 12. For subdivision sign installation; outside installers must be bonded with ACHD and obtain a no -charge right-of-way permit. 13. Prior to placement of any pavement markings contact ACHD Inspection for verification of compliance with policy and existing pavement markings. DRAINAGE 1. For any drainage facilities within a public Right -of -Way, ACHD or ITD shall be responsible for inspection. For any private drainage facilities the project engineer or architect shall be responsible for inspection and certification of drainage facilities; however any roof drainage and piping to the facilities will be inspected by the Meridian plumbing official under the appropriate permit. SEWER 1. Construction of the sewer system shall conform to the standards in the Wastewater Rules (IDAPA 58.1.16) as well as the standards and specifications referred to in General Construction Note No. 1. 2. The horizontal separation of potable water mains and non -potable water mains (sanitary sewer, storm drain, and irrigation) shall be a minimum of ten (10) feet. Where it is necessary for a potable water main and non -potable water main to cross with less than eighteen (18) inches of vertical separation, the crossing shall be constructed in accordance with Section 542.07 of the Idaho Rules for Public Drinking Water Systems (IDAPA 58.01.08) and Section 430.02 of the Wastewater Rules (IDAPA 58.01.16). 3. The horizontal separation of non -potable services and potable water services or potable water mains shall be a minimum of six (6) feet. Where it is necessary for a potable water main and non -potable water main to cross with less than eighteen (18) inches of vertical separation, the crossing shall be constructed in accordance with Section 542.07 of the Idaho Rules for Public Drinking Water Systems (IDAPA 58.01.08) and Section 430.02 of the Wastewater Rules (IDAPA 58.01.16). 4. Place sewer service lines in a six (6) inch diameter water class pipe sleeve wherever the service line crosses a storm water treatment facility (i.e., seepage beds, drainage swales). WATER 1. Construction of the water system shall conform to the standards in the "Idaho Rules for Public Drinking Water Systems (IDAPA 58.01.08)" as well as the standards and specifications referred to in General Construction Note No. 1. 2. The horizontal separation of potable water mains and non -potable water mains (sanitary sewer, storm drain, and irrigation) shall be a minimum of ten (10) feet. Where it is necessary for a potable water main and non -potable water main to cross with less than eighteen (18) inches of vertical separation, the crossing shall be constructed in accordance with Section 542.07 of the Idaho Rules for Public Drinking Water Systems (IDAPA 58.01.08) and Section 430.02 of the Wastewater Rules (IDAPA 58.01.16). 3. The horizontal separation of non -potable services and potable water services or potable water mains shall be a minimum of six (6) feet. Where it is necessary for a potable water main and non -potable water main to cross with less than eighteen (18) inches of vertical separation, the crossing shall be constructed in accordance with Section 542.07 of the Idaho Rules for Public Drinking Water Systems (IDAPA 58.01.08) and Section 430.02 of the Wastewater Rules (IDAPA 58.01.16). 4. Place water service lines in a two (2) inch diameter pipe sleeve wherever the service line crosses a storm water treatment facility (i.e. seepage beds, drainage swales). 5. The Contractor shall be responsible for providing continuous water service to all existing water users affected by construction. If water service must be interrupted, the contractor shall coordinate with the Public Works Inspector. GENERAL LEGEND SS EXISTING SEWER LINE W EXISTING WATER LINE SD NEW STORM DRAIN W NEW WATER LINE S NEW SEWER LINE PI NEW PRESSURE IRRIGATION LINE W/SERVICE x x x x x x EXISTING FENCE Ep EXISTING EDGE OF PAVEMENT EP NEW EDGE OF PAVEMENT SAW CUT LINE ----- BOUNDARY LINE ROADWAY CENTER LINE ROADWAY RIGHT-OF-WAY - - - - - - - - - - EASEMENT BOUNDARY LOT LINE - - -- EXISTING CONTOUR ��600 -� FINAL GRADE CONTOUR ELEVATION ® STATION STATION POINT (TOP BACK OF ROLLED ELEVATION CURB UNLESS OTHERWISE NOTED) TVC = TOP BACK VERTICAL CURB TRC = TOP BACK ROLLED CURB TRLC = TOP REVERSE LIP CURB PC = POINT OF CURVATURE PT = POINT OF TANGENCY FL = GUTTER FLOW LINE GB = GRADE BREAK GC = GRADE CHANGE HP = HIGH POINT LP = LOW POINT El = END INVERT SEWER SERVICE SANITARY SEWER MANHOLE 00 EXISTING SANITARY SEWER MANHOLE --------- 4" SEWER SERVICE LINE TYPICAL DOUBLE WATER SERVICE PROPOSED FIRE HYDRANT PER o EXISTING FIRE HYDRANT OLOT NUMBER HE CATCH BASIN - ISPWC PER PLANS DIRECTION OF DRAINAGE FLOW t-* STREET LIGHT EXISTING DECIDUOUS TREE (CALIPER) EXISTING POWER LINE & POLE DEVELOPMENT PLANS FOR BRIAR RIDGE SUBDIVISION OFFSITE LOCATED IN THE E 1/2 OF SECTION 36, TOWNSHIP 3 NORTH, RANGE 1 WEST, BOISE MERIDIAN, MERIDIAN, ADA COUNTY, IDAHO 2022 CONSTRUCTION I AREA I I PREVAIL SUBDIVISION C\NS a I CD z McBIRNEY I 0 LATERAL 00 FUTURE m z BRIAR RIDGE m W v SUBDIVISION SHAFER Q ESTATES N� W LAKE HAZEL JW - NAVD 1988 DATUM VICINITY M A P 1 " = 600' SHEET DESCRIPTION 1 - COVER SHEET, INDEX, VICINITY MAP, & NOTES 2 - SEWER PLAN & PROFILE 3 - WATER AND SEWER PLAN & PROFILE THE ENGINEER OF RECORD CERTIFIES THAT THE PLANS ARE PREPARED IN SUBSTANTIAL CONFORMANCE WITH THE ACHD POLICY MANUAL AND STANDARDS IN EFFECT AT THE TIME OF PREPARATION. THE ENGINEER ACKNOWLEDGES THAT ACHD ASSUMES NO LIABILITY FOR ERROR OR DEFICIENCIES IN THE DESIGN. ALL VARIANCES FROM ACHD POLICY SHALL BE APPROVED IN WRITING. THE FOLLOWING VARIANCES, LISTED BY DATE AND SHORT DESCRIPTION, WERE APPROVED FOR THE PROJECT: - NONE. Plans Are Accepted For Public Street Construction By stamping and signing the improvement plans, the Registered Engineer ensures the District that the plans conform to all District policies and standards. Variances or waivers must be specifical- ly and previously approved by the District in writing. Acceptance of the improvement plans by the District does not relieve the Registered Engineer of these responsibilities BYDATE: ADA COUNTY HIGHWAY DISTRICT ENGINEER BAILEY ENGINEERING, INC. 1119 E STATE ST, SUITE 210 EAGLE, ID 83616 TEL: 208-938-0013 EVELOPER T LOGY DEVELOPMENT, INC. 9839 W CABLE CAR ST, SUITE 101 BOISE, ID 83709 TEL: 208-895-8858 NOT APPROVED FOR CONSTRUCTION C� p `" o V � �wv Z_ ~a di Z 3 p Z .= la o � � W Z w W F LIJ w 'ccad C'S W a� �o J �- ui w V w 5g\ONAL FNc O\ST/11/2022 FR�o LF F N 882 F 9TF OF S. CRP\ CHECKED BY: DAVID A. BAILEY P.E. 0 F V) 0 ON a 1n C, LJ z k W 0 LLW IV L. 1L L.L 0 Z 0 m� W D V) (W V L.L Z W d 0 J W i W 0 PREVAIL SUBDIVISION NO. 2 n 41 +I ® -� EX SEWER MANHOLE-1 [LOCATED OFF OF PLAN SHEET IN 3� PREVAIL SUBDIVISION NO. 2. Iddl APPROX 314-FT EAST OF EX -SEWER MANHOLE-21 N RIM: 2726.12 w INV E (12"):2708.29 INV W (12"):2708.39 MERIDIAN RD. (HWY 69) SSMH OFFSITE-2 / � PROTECT EXISTING CMP '2732_ / 1 / / ���>� RECONSTRUCT LOR RECONSTRUCT TO RECONSTRUCT PROTECT EXISTING CMP MAILBOX �To EXISTING CONDITIONS [IF °' DITCH TO EXISTING EXISTING OR RECONSTRUCT TO 2 — i r — EXISTING CONDITION CONDITIONS DISTURBED] CONDITIONS [IF r--------------------- -d3-- - i - -- - DISTURBED] -- - - - - - 7 i — d3 d3 a3 as a3 __ da-------- ' — 00 9O TOP LOP— — _ TOFTOP — — — TiiP TOP_ — — — — SDP— — — TOP d3—d3� 3— d3 — d3 _ _ — d3 W PROTECT 30" CMP`---- —c_�—------- —— — TOP d3 IN PLACE —------------ o— --- Q — -- o _— TOP— Toa roa —row d ow To 'dEOE-1-29oe + n � �—doy doy � doy doy �y' � — r` o TOE o TOE TOE Cp M d01 p = OL — — — doy doy Oy d doy doy U —0 T d0 --- d0 _ — - ---- - do a6- ---� do --- --- eo - -- -- - -- -- --- --- -- --- Q H 1 ed—C——-----—--_ /� do do _ V Q _"_OP 179° — oP�� P — — — PROTECT EX SSMH OFFSITE-1 PROTECT EX PROTECT EX POWER POLE IN PROTECT EX TELEPHONE PROTECT EX PLACE PROTECT EX BOX IN PLACE 274 272 272 272 272 272 272 27: 271 271 271 27C RIGHT-OF-WAY POWER POLE IN DITCH OR LINE PLACE RECONSTRUCT TO PROTECT EX TELEPHONE BOX IN OVERHEAD POWER PROTECT EX I POWER POLE IN TELEPHONE BOX IN PLACE EXISTING I PLACE RIGHT-OF-WAY PLACE I CONDITIONS [IF PROTECT EXISTING PVC RECONSTRUCT LINE PROTECT EX IRR DISTURBED] OR RECONSTRUCT TO DITCH TO EXISTING PROTECT EX BOX EX SEWER MANHOLE-2 51236141820 EXISTING CONDITIONS [IF CONDITIONS 51236141 g00 DITCH OR I 1 RIM: 2726.57 PERCY FARMS LLC DISTURBED] p INV E (12"):2710.75 INV W (12"):2710.85 5385 S MERIDIAN RD I PERCY RENTAL LLC EXISTINSGTRUCT TO S1236141820 30 0 15 30 60 5385 S MERIDIAN RD CONDITIONS [IF PERCY FARMS LLC DISTURBED] 5385 S MERIDIAN RD SCALE IN FEET 1 "=30' W N N N N — Z ^_^_00 (nN I W MHO (V� 000� O O F) M N N H ~ O 2NN��0 LT i0 q 'D r, NF�>>> Z Z OO (N� U)fnKZ 2(0NZ0 !n m > > 219' LF TYPE 'C' SUR ACE REPAIR 27' LF TYPE 'SURFACE REPAIR !n N Z Z PER ISPWC SD 303 — 421' LF TYPE 'C' S RFACE REPAIR EXISTING GRADE PER ISPWC SD-303 — PER ISPWC D-303 — — — — — —— — — — --- — — — — —— ----------------------------------------- - — — — — — — — — — r - - - _ ----------- ---------- -------------------- ---- EX 12' 0. ------------------- 7%-------------- - ----- --- --- --- ------------- --- ---------- -------- l �� STA: 7t INV: 272 5.26 .38 _PVC_® - STA: 6+40.61 A 7+52.41 EX 12" --------- - --------- -------------------- INV: 2728.58 I 2728.72 CMP 0.04% 7 STA 3+87.42 STA: 5+95. 2 INV: 2727.36 INV: 2728. EX 12" CM ® -0.22% P7 O �7 oW L_ +� 00 = �Q " PVC 0.24% 392 LF C-C) 395 LF 12" PVC 00 24% (3 9 LF C-C) 7 OFFSITE SEWER PROFILE H R: 1 "= 0' ER: 1 " ' 270 +80 2+10 2+40 2+70 3+00 3+30 3+60 3+90 4+20 4+50 4+80 5+10 5+40 5+70 6+00 6+30 6+60 6+90 7+20 7+50 7+80 8+10 8+40 !739 !736 !733 !730 1727 '724 1721 1718 '715 '712 '709 8+70 06 KEYNOTES O INSTALL NEW SEWER MANHOLE OVER EXISTING SEWER MAIN PER ISPWC SECTION 502.3.5.B.2. O APPROX MAX SAWCUT LINE SHOWN. SEE MERIDIAN RD. REPAIR SECTION, THIS SHEET. SAWCUT AT LOCATION SHOWN IS BASED ON TRENCHING APPROXIMATIONS AND MAY NOT BE NECESSARY FOR CONSTRUCTION DEPENDENT ON TRENCHING TECHNIQUE(S) AND SITE CONDITIONS. COORDINATE ANY SAWCUT WITH ITO. NOTE: ALL SEWER MANHOLES ARE TO BE 60" INNER DIAMETER, CONSTRUCTED PER ISPWC SD-501. THE SLOPE AND LENGTH OF SEWER MAIN IS CALCULATED FROM INSIDE FACE OF MANHOLE TO INSIDE FACE OF MANHOLE. THECITYOF MERIDIAN REQUIRES 5 FEET OF COVER OVER WATER MAINS THAT RUN ON MID -SECTION LINES. ALL WATER MAIN IS TO BE BLUE ANSI/AWWA C-900 DR18, PER CITY OF MERIDIAN SUPPLEMENTAL SPECIFICATIONS. BENCH MARKS 6MTBM TBM #1 - 2726.57 - RIM OF EX SEWER MANHOLE-2. LOCATED APPROX STA 2+00 ON EXISTING SEWER MAIN. SEE SHEET 2. TBM #2 - 2730.45 - BRASS CAP [HIGHWAY MONUMENT] LOCATED APPROX STA 5+20. SEE SHEET 2. 4" ASPHALT PAVEMENT (SP-3, 1/2" MIX, PG 64-28) 4" - 3/4" MINUS CRUSHED GRAVEL �OO 17" - 6" MINUS PIT RUN MERIDIAN ROAD TYPICAL REPAIR SECTION NOT TO SCALE -USE THIS SECTION OR MATCH EXISTING ROAD SECTION - WHICHEVER IS GREATER. -SECTION BASED ON R>20 W/ TI=10; REFER TO SITE GEOTECHNICAL BY SITE CONSULTING, LLC DATED NOVEMBER 30, 2018. NOT APPROVED FOR CONSTRUCTION �o w Z_ ~� W Z 3 = a zw W fZ' � W ~ w Z w 'cc m Z W <o J N- V w 5g\ONAL FNc C,\STFR�o GF 2 02/11//20022 �f H Z F�TF OFQ) CHECKED BY: DAVID A. BAILEY P.E. ON W Q N o Q Izl W J LL 0 1� R z Q J 274 27: 272 272 272 27[ 272 27: 271 271 271 27C PREVAIL SUBDIVISION NO. 1 SSMH OFFSITE-3 - - - O - - - - C7 W d3 — — _ d3 d3 d3 \ _ CD Ld -TOP—TOPTo _ V) S------0----- -- - 16 oo = TOE —TOE 3C! 3( - -—Tori Tna = - � PROTECT EX — PROTECT EXISTING CMP DITCH OR OR RECONSTRUCT TO RECONSTRUCT TO EXISTING CONDITIONS [IF EXISTING DISTURBED] CONDITIONS [IF DISTURBED] S1131233820 JOSE ASEGUINOLAZA 5570 S MERIDIAN RD N, 0' cf) m Q LLJ ILLJ 0� m� R7824220044 SHAFER VIEW NORTH LLC E SHAFER VIEW DR. / p TOP II MERIDIAN RD. (HWY 69) ICI P i 12" WATER MAIN 1 ICI J_ L da � — — _ TOP— — — TOP de Tov— A �\ ai -- -_I_-I _ —roP Y C a - - - - - r�-rF-��� 5�-� ��•� Toe - - - - - Tee_ - �� _ woe- T-ei�Toe�=TKO .O / - - - 3oi a3 eoi-ei — —nor- _ — — eoi- - - - - ---� PROTECT EX-1 XDITCH OR RECONSTRUCT TO SSMH 0FFSITE-4 II EXISTING CONDITIONS [IF S1236141820 DISTURBED] IT Ell a � _ _ PERCY FARMS LLC - SEE BRIAR RIDGE SUBDIVISION 5385 S MERIDIAN RD DEVELOPMENT PLANS. PLAN DEMARCATION AT SEWER S1236141820 BLOCK —OUT & WATER PERCY FARMS LLC BLOW —OFF. 5385 S MERIDIAN RD IIL II 0 !I If 29' L TYPE 'P' SURFACE REPAIR 496' LF TYPE 'C' SURFACE REPAIR PER ISPWC SD 303 4' LF ­YPE 'C' SURFACE REPAIR PER ISPWC SD-303 ER ISPWC SD- 03 SSMH OFFSITE-4 RIM:2735.40 INV IN:2 13.51 12"W Z [B OCKOUT W] (n N INV OUT:2 13.41 12"N �N �pNn _ O)�NH r +,z0 EXISTING GRADE ate>> tSIA: 12" WATER— 9+21.40 INV* 2729.44 7 EX 12- CMP ® 0.04% o� oW Lo _ +N 00 = Q � N < O 381 F 12" PVC 0.247 88 LF 12" PVC ®0.24% 385 LF C- ) OFFSITE SEWER PROFILE H R: 1 "= 0' ER: 1 +40 8+70 9+00 9+30 9+60 9+90 10 20 10 50 10 80 11 10 11 40 11 70 12 00 12 30 12 60 12 90 13 20 13 50 13 80 14 2742 1739 1736 1733 '730 !727 '724 '721 1718 '715 '712 I� 1 \ I 30 0 15 30 60 I SCALE IN FEET 1 "=30' KEYNOTES O APPROX MAX SAWCUT LINE SHOWN. SEE MERIDIAN RD. REPAIR SECTION, SHEET 2. SAWCUT AT LOCATION SHOWN IS BASED ON TRENCHING APPROXIMATIONS AND MAY NOT BE NECESSARY FOR CONSTRUCTION DEPENDENT ON TRENCHING TECHNIQUE(S) AND SITE CONDITIONS. COORDINATE ANY SAWCUT WITH ITD. O REMOVE EXISTING BLOW -OFF ASSEMBLY & CONNECT TO EX. 12" WATER MAIN. Q3 CONST. 2" BLOW -OFF ASSEMBLY (FUTURE WATER MAIN EXTENSION) PER MERIDIAN W13. ® POTABLE/NON-POTABLE MAIN CROSSING. REFER TO WATER NOTE 2 ON COVER SHEET 1.0. ALL SEWER MANHOLES ARE TO BE 60" INNER DIAMETER, CONSTRUCTED PER ISPWC SD-501. THE SLOPE AND LENGTH OF SEWER MAIN IS CALCULATED FROM INSIDE FACE OF MANHOLE TO INSIDE FACE OF MANHOLE. THECITYOF MERIDIAN REQUIRES 5 FEET OF COVER OVER WATER MAINS THAT RUN ON MID -SECTION LINES. ALL WATER MAIN IS TO BE BLUE ANSI/AWWA C-900 DR18, PER CITY OF MERIDIAN SUPPLEMENTAL SPECIFICATIONS. BENCH MARKS 61 TBM #1 - 2726.57 - RIM OF EX SEWER MANHOLE-2. LOCATED APPROX STA 2+00 ON EXISTING SEWER MAIN. SEE SHEET 2. TBM #2 - 2730.45 - BRASS CAP [HIGHWAY MONUMENT] LOCATED APPROX STA 5+20. SEE SHEET 2. NOT APPROVED FOR CONSTRUCTION � oN Q �d V w Z_ ~� 3 Z 3 z a_ C3 Zw W W ~ w Z w lf W <o J N- V w 5g\ONAL FNc � C,\STFR�o GF 2 02/11//20022 � �8� F- OF F N S. CRP CHECKED BY: DAVID A. BAILEY P.E. ON w a fN 0 Ld z W J I 0 1� R w V! ILL ILL 0 Z 0 _V) mQ W D rw V