Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Photometric Plan V1
DWRIDIA )- APPROVED \ alre orvaorzz \\ ILLNU111FA:"-� \ \ \ 101 101 M l v � I \ 7�\ --- ----- 1L\� BLOCK 2 \ 1 -'-1------_--_------------------------------------------------- ------ ------I --- - _--_----_------- -- -_ \ \ \ \ = \o o..o-..o-..1 ..1 ooo-.o o o b.o b.o b.o b.o0 b. b.0 F- .b. \ \ \g' , b.6 b.0 b o b Q p \ b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.l b.l b.l b.o b.l b.l b.l b.l b.o b.o b.o b.1 b.o 1:1] b. b.1 b.l b^e�anen1 1 0. 0.1 .o b.o b.o b.o b � ' \\ 1st Gale 2nd cads \\ A + ��o b.o ` �. v.K a K 3 a fi\o 0 b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.1 b.1 b.z b.4 b.z b. 1 b.1 b b.1 b. b 1 .1 b b.1 .1 b.i b. b.1 b.1 b. \\ \ \ m.m Ili 1 \ b o\\ b.o b.o \ b.o \ b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b.o b b.1 b.1 b.z b.3 b o b.9 z b.z o b.1 b. z i. b. .2 .2 .z b.z z TPPT b. III b.1 b.1 b \ 12 b b.o b.0 b.h �o b.o b.o b.o b.o b.o b.o b.o b.o b b.1 b. b.3 b.s i i.a 2 s z. ® b 3 .4 .4 .4 3 b.3 b.z b. + \ \ z ram, olas r.�olas I 1 ' \ �cm® 1 \ \ + Q.o b.o b o g.o b.o b.0 b.0 b.0 b.0 b.0 b.o b.0 b.1 .1 b.z b.4 b.9 i.a 2.9 5.9 a.9 5 i. a 6 E�d� .7 b.7 b.s b. A V V®I ® PhaseIB ® - III 1 b.o b.o o.o b:o \ b.o b.o b.o b.o b.o b.o b.o b.1 b.1 b.z b.s i.l 2.o g (�2. s 6 i z tl o i. v i. i.z i.l i.s 9 i. i.s 3 i 6 i.a i.6 1.1 b.. ; \ \.. \ • • * _ 3k Gale mGratl-G�aEe' III 1 \ \ \ \ + 2 b\o b.o b.� b b o b.0 b.0 b.0 b.0 b.0 b.0 b.1 b.1 b.z b.s b.9 i.3 i.s i.e i.9 i.] i. b.6 2. L e 2. i.e 4%a a 2.a}� 2.] .3 v ` `\ A \ rm�,ic-p LLJ \ o b.o b: b.o- b\o b.o b.o b.o b.o b.o b.1 b. b.z b b.s b.] b.e b.e i.l '.4 b.8 ® b.8 i.I 2. 5.5 .0 5.2 _ 1 v 1 AV V o o o \ ��.o \ b.o b.o \ b.o \ b.a o b.o b.o b.o b.o b. b.1 b b.z b.3 b.3 b.a b.s b.6 '.o i.a z.o i s i i.�i. 2.0 5.z 5.s �e Y.O 2.O 5 1 5.7 5. 3 i.9 1.9 v 1 \ v A , \ \ \ \ o` )Q b.o b.o\ `b�'b.� b.o b.o b.o b. b.1 b b.1 b.z b.3 b.3 b.4 b.6 b.9 1.3 1.8 z.z z.3Phase 1lA.8 1.4 1.5 1.9 2.4 3�.4 2.0 .] '. _� 3--z-1- 2. -- -- � \\ \ \ \\b.o b.o .0 .0 b.o b. b.1 b b.1 b.z b.3 b.4 b.s b.s b.6 i.1 i.] 2.0 p9 L3 .6 2.3 2.0 2.0 2.z 2.9 2.z 1.a,.s i.6 i.a 2.1 2.3 2.1 i.9 i.9 i.9 i.a i.3 b.7 I \ - - - - --------------------- II \ V A\ �0.0\ b.o b.o \ .0 b.0 \b. b.o b b.1 b.z b.3 b.s b.8 b.8 b.8 b.7 1.0 1.6 .3 2.] 2.8 2.4 2.2 2. 2.5 2 .8 l.si' .8 2. 2.4 .1 1. 2.0 2.1 b. El BLOCK 2 p 0 ; � L � b.o b.4 b.0. .o\ b. b.1 b.1 b.3 b.s b.9 i.4 i.s i.4 i.o i.o i.3 1.9 2.3 2.6 2.3 0 2. 2.z .z i.s ;� .s z.3 .6 .s z. z.z i.q V �% vv A \ , \\ \ \ `\c.0 0.0 .0 0 1 0.1 0.2 0.4 0.7 1.4 2.1 2.0 1.] 1.3 1.0 1.3 1. 2.6 2.9 2 2.7 2.6 2.5 2.9 2. 1 1.7 } .9 �.3 2. 2.8 �.7 2. 2.7 2.2 2.9 \ .0\0.1 \ 0.1 0.2 0.4 0.8 l.s 1J L3 �. 2 3 2.6 2.2 2.0 1. l.s T.7 1.9 2.2 2.8 2.9 2.7 2.2 2.9 2.9 2 .� A L2 I 1 Ol\ 0.0 0 0 0.1 0. \ 0.2 0.4 0.8 l.s 2.0 1.8 1.9 1 .0 1.0 l.s 2.2 2.3 2 3 1.9 1.8 1.6 1. 1.3 } �.0 �.5 2. 2.0 �.8 2. 2.9 2.5 9. 2.6 ,� `\0.0 0.0 !).\ 1\ \1 0.3 0.6 1.1 1.6 1.2 l.s 1.1 0.8 0.8 1.1 1.4 1.9 2.0 1J 1.4 1.6 1. l.s .0 .6 2.0 L 2. 2.5 2.8 2.3 iq 1 \ \ \ \ 0.0 0.0 \ .1 \0.1 �0.2 0.4 0.7 0.9 0.6 .9 0.7 0.6 0.6 0.8 0.9 1.2 4 LO �.4 2. 2.7 .1 2. 2.5 2.9 2,O 1.3 I \ \ \\ + 0 0.0 0.1\ 0.1 0. \ 0.2 0.4 O.s 0.3 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.9 1. �. 2.1 2.5 11 2.0 }.9 2.1 2.5 2.8 2.2 2.9 2.9 2.5 2.6 6 \ �� 1 \.2 3 \ 0.0 0\ 0 0.2 0.3 0 0.6 0.8 0.9 1.0 0.9 0.7 0.6 0.8 1.2 1.8 2. 2.5 1.9 }.9 2.0 2.9 2.9 2.1 2.7 2. 2 2.9 2.8 2.9 l 0.0 0.1\ \.1 \.1 \ 0.2 0.2 0.3 0.7 .2 *.6 *.6 *.3 0.9 0.7 0.7 *.1 *.4 �.9 2.?1.3 1.] .0 2.5 2.1 2. 2.5 2.7 2 1J70 00 0.1 0.1 0. 0.2 0.4 9 1.6 1.9 2.1 1.] 1.1 0.7 0.6 0.7 0.9 1.2 1.1.3 } .0 �.9 2. .3 �.7 2. 2.9 2.9 2.4 9. 2.5 I \\ \ \\ \ +,\\o.o 0.1 0� 011 2 O.s 1.0 1.8 1. 1J 1.8 1.2 0.7 0.6 0.7 0.8 1.0 1. 1.1 1.2 }.s i.9 2.s 2.8 2.1 \\ \ \ \ \\18•0. 0.1 \ .\ 0.2 \ 10.4 0.9 l.s A2 L3 1.] �.6 1.1 0.7 0.6 0.8 1.0 1.2 1. 1.2 }.s 1.9 2.9 2.7 1.9 2.6 2.3 2.3 2.8 2 9 2.7 I \ \\ \ \\ ,,0\ 0\ 0.7 1.2 1.4 �.4 1.3 0.9 0.7 0.8 1.1 1. 1.6 2. 1.8 1.6 } .9 �.2 2. 2.2 �.8 2.3 2.2 2.6 2.8 2. 1�.4 I L 11 \\\ \ .0 0.1 0. 0. .4 0.7 o.e o.e o.9 o.e o.e i.o i.s 2. 2. L 2.6 2.0 �1\ .1 ".z 2.37.4-2.8 z. z.z 2.s 2.s z. i.l 1 2 � 4 0.4 0.6 0.9 1.1 1.2 l.s 2.9 .9 2.7 2.9 2.5 .9 2. .9 .1 2. 2.5 ,_------------_-------------------- --- -II \ \ \ \ \ \ 1 0.1 o.l\ .2\ 0.3 0.� 0.6 1.1 1.9 2.2 2.6 2.2 2.7 9.7 9.8 9.1 2.5 2.3 2.3 2.9 2.9 2.8 2.2 2.9 2.2 2.8 2.9 1 6 0.7 1 0.1 0:� .3 \0.6 1. 2 2 2. .6 9 1 9. 9 8 9. .9 9 2 £3. .8 8 .1 9 4 3,3 4 1.4 0. 0.1 0.1 z s:. o.s\ i.o .7 2 ' a i.o a s 1 b,1\0.3 o s\ 0.9 i.6 2.8 ®2.1 i.7 1Il 6 2.1 L2 .a 2.1 i.] 1.3 1.2 / :f 9 A L� o.s 0.z A 0.1 \ 0.1 0:1\ 0.. 0.3 O.s 0.9 0.8 0.7 O.s B.s 0.7 0.8 1.1 0.8 0.6 0.4 0. 4/� I` p� yq0.0\ 0. 0/ 0, \0.2 0.3 0.3 0.3 0.2 �1.2 0.3 0.4 W.QCIbF3 0.3 0.2 0.21 0.3 0.2 0.3 0.2 0.1 0.1 0.1 3 o.o o.\ o. fY 0. \ 0.1 0.1 0.2 0.1 1 1 0.2 0.1 0.1 0.2 0.1 0.1 o.y 0.1 0.1 0.1 0.1 0.1 0.0 0.0 \ +% .o o.o o.� o. 0`.1 1\ o.o 0.1 0.1 ro.1 0.1 0.1 f .1- oz o.i o4 0,1 b.1 o.o 0.1 0.1 \ �� o 1 \ \ o.o o.o b\0 b 0 Q.a o.a b.a b.1 o.1- ' o. o.1 o.o .o 1 o.0 o.0 o.o '� a l \ +, -, \ - --- \ o.o o.o Vo.o o.o o o - - - - - \ \ % A \ Oro o.o b o '.oy 48 �V `® o.o 0 0� BLOCK 54 / 49 BLOCK 1 50 1 \ v 46 51 II \ \ \\ 45 \; N. PHOTOMETRIC SITE PLAN Scale: 1" - 40'-0" b.z Ib.1 2 3 4 5 6 7 8 9 10 11 0 12 13 14 15 16 17 18 19 20 BLOCK 1 21 NOT FOR CONSTRUCTION 4co world wide web: e2co.com 800 S. industry way, suite 350 ineerin com an meridian, idaho 83642 electricalen g g p y phone:208.378.4450 fax: 208.378.4451 engineering 4 tomorrow e2co project #: 21043 IL V ARC HITEC T 8 2400 E RIVERWALK DRIVE BOISE,IDAHO 83706 WWW LKVARCHITECTS.COM 208.336.3443 L O\ cc M LL _ o � U N Z Q 70 o M 0- > T- o ca �U M J DATE: March 19, 2021 LKV PROJECT #. REVISIONS: DRAWN BY: JWVS CHECKED BY: JWVS Proposed Church Facility DRAWING NO. E1.1 LIGHTING FIXTURE SCHEDULE - CALVARY CHAPEL TREASURE VALLEY l.�l�l SITE PHOTOMETRIC SCHEDULE I DvANO MANUFACTURER CATALOG NUMBER MOUNTING LAMPS VOLTAGE REMARKS RE SOFT CORNER LITHONIA NO. RSX2-LED-P3-40K-R5-MVOLT LED APPROVED ASKETED LENS, POLE 22317 LMS ARM 40 K 120/277 1 Q41E: 06/30/22 rNGGA UTION MOUNTED 147 W LE W/ BASE COVER •e 1.,xx FRG NNnRR:A-2022-0130 RE SOFT CORNER LITHONIA NO. RSX2-LED-P3-40K-R3-MVOLT LED ASKETED LENS, POLE 21737 LMS AL2 LED ARM 40 K 120/277 1 TYPE V - WIUTION MOUNTED 147 W SINGLE HEALE W/ BASE COVER AREA LIGHT LITHONIA NO. RADPT-P540K-SYM-MVOLT-PT4-FAO-DDBXD POLE LED AL3 POST TOP FIXTURE - 20' POLE TOP 15541 LMS 120/277 1 ROUND 4" POLE - DARK BRONZE MOUNTED 40 K FOA (FIELD ADJUSTABLE OUTPUT) 86 W REMARKS 1. OR PRE -BID APPROVED EQUAL 2. PROVIDE WITH BODINE EMERGENCY DRIVER SUITABLE FOR LAMP TYPE AND HALF THE LAMP LUMEN OUTPUT, PROVIDE WITH SELF TEST LIGHT AND PUSHBUTTON, 3. SEE LIGHTING DRAWINGS AND LIGHITNG CONTROL PANEL SCHEDULES FOR ADDITIONAL INFORMATION INCLUDING NUMBER AND TYPE OF RELAYS THE ELECTRICAL CONTRACTOR SHALL INCLUDE FACTORY START-UP AND PROGRAMMING OF THE LIGHTING CONTOL SYSTEM AS WELL AS COMMISSIONING 4. WHEN INSTALLED IN AN INSULATED CEILING, FIXTURE TO BE INSTALLED WITH FIRE RATED OR IC RATED ENCLOSURE OR HAVE SHEET ROCK ENCLOSURE BUILT PER DETAIL NOTE TO BIDDERS: 1. BID ONLY PRODUCTS THAT ARE SPECIFIED OR APPORVED VIA ADDENDUM. SUBMITTED ITEMS NCT APPROVED VIA ADDENDUM WILL BE REJECTED 2. PACKAGING OF LIGHT FIXTURES WITH OTHER SYSTEMS IS NOT ALLOWED 3. WHEN ONLY ONE PRODUCT IS APPROVED FOR BIDDING, THE PRICE FOR THAT ITEM SHALL BE BROKEN OUT SEPERATELY WHEN SUBMITTING PRICING TO THE VARIOUS DISTRIBUTORS AND/OR CONTRACTORS AS REQUESTED. i,� � `/ E IDIAN APPROVED DATE: 06/30/22 FILE NLWBEkA-=0 130 Specifications EPA: 1.02 ftz (0.105 mz) Length: 24 (61 cm) Width: 24" (61 cm) H 1 4„ Luminaire Height: (10.16cm) H 2 26" Luminaire Height: (66.04cm) Weight: 38lbs (17.24Kg) Ordering Information RADIPTLED Radean Post Top LED Area Luminaire N St _ M-1 -0 RADPTLED P1 3,000[omens P2 5,000 Lumens 27K 2700K 30K 3000K SYM SymmetrictypeV ASY Asymmetric type IV P3 7,000 Lumens 35K 3500K PATH Pathway Type III P4 10,000 Lumens 40K 4000K P5 15,000 Lumensl 50K 5000K Shipped installed SF Single Fuse' Shipped installed NLTAIR2 nLightAIR2.0enabled DF Double Fuse' HS Housesideshield1° FIR Bi-level motion/sensor R90 Rotated optics9 (100%to 30%) 4A1 PE Button photocell I FAO Field adjustable output-' Catalog Number Notes Type -lit the Tab key or mouse over the page to see all interactive elements. Introduction The architecturally -inspired shape of the RADEANTM post top area luminaire embodies the grace and strength of the RADEAN family. The twin copper -core cast aluminum arms support the slender superstructure, creating a beautiful sculpture by day transforming into a beacon of comfort by night. Triangular arms redirect reflection maintaining its visually quiet appearance. With sleek lines and simple silhouettes, these LED luminaires use specialized lighting and visual comfort to transform common areas like courtyards, outdoor retail locations, universities and corporate campuses into pedestrian -friendly nighttime environments. EXAMPLE: RADPT LED P3 30K SYM MVOLT PT4 PIR DNAXD MVOLT' 2771 7 Slips inside a 4" 0D round metal pole 120' 347 RADPT20 Slips over a 2 3/8"diameter tenon 2081 480 RADPT25 Slips over a 2 7/8"diameter tenon 2401 DDBXD Dark bronze DDBTXD Textured dark bronze DBLXD Black DBLBXD Textured black DNAXD Natural aluminum DNATXD Textured natural aluminum DWHXD White DWHGXD Textured white fA L/THO/V/A COMMERCIAL OUTDOOR One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com RADPT LED L/GHT//VG 0 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 12/15/20 IDS IAN,_ APPROVED DATE: 06/30/22 FILE NUMBER: ^- D—D13D Expansior "® Ole (specify finish) ROAM online. PT4 RADPT20 or RADPT25 on Slipfitter `--+ 11 Control Options NLTAIR2 PIR (No visible change) NOTES 1 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). Single fuse (SF) requires 120, 277 or 347 voltage option. Double fuse (DF) requires 208, 240 or 480 voltage option. 2 Required nominal 4" round straight metal pole. 3 NLTAIR2 not available with PIR, PE or FAO. Must link to external nLight Air network. 4 PIR will work with FAO, if adjustable low -end trim is required. 5 PIR must specify 120V, 277V, 347V or 48OV. Not available in MVOLT, 208V or 240V. 6 PE and PIR are available together. 7 PIR for use only on luminaires mounted under 15'. 8 Field adjustable high -end trim. 9 For left rotation, select R90 and rotate luminaire 180* on pole. 10 Also available as a separate accessory; see Accessories information at left. HIS not available with R90. Shield is field rotatable shield in 180' increments. Acuity Part Number Description 1 For luminaires Used with Mounting RSS104BPTDDBXD 10' Round Straight Steel -4"O.D.-Open Top RADPTLED PT4 RSS124BPTDDBXD 12' Round Straight Steel -4"O.D.-Open Top RADPTLED PT4 RSS144BPTDDBXD 14' Round Straight Steel -4"O.D.-Open Top RADPTLED PT4 RSS164BPTDDBXD 16' Round Straight Steel -4"O.D.-Open Top RADPTLED PT4 RSS184BPTDDBXD 18' Round Straight Steel -4"O.D.-Open Top RADPTLED PT4 RSS204BPTDDBXD 20' Round Straight Steel -4"O.D.-Open Top RADPTLED PT4 RSS254BPTDDBXD 25' Round Straight Steel -4"O.D.-Open Top RADPTLED PT4 RSS104BT20DDBXD 10' Round Straight Steel -4"O.D.-Tenon Top RADPTLED RADPT20 RSS124BT20DDBXD 12'Round Straight Steel -4"O.D. -Tenon Top RADPTLED RADPT20 RSS144BT20DDBXD 14' Round Straight Steel -4"O.D.-Tenon Top RADPTLED RADPT20 RSS164BT20DDBXD 16' Round Straight Steel -4"O.D.-Tenon Top RADPTLED RADPT20 RSS 18 4B T20 DDBXD 18'RoundStraight Steel -4"O.D.-Tenon Top RADPTLED RADPT20 RSS 20 4B T20 DDBXD 20' Round Straight Steel -4"O.D.-Tenon Top RADPTLED RADPT20 RSS254BT20DOW 25' Round Straight Steel -4"O.D.-TenonTop RADPTLED RADPT20 * Customer must verify pole loading per required design criteria and specified wind speed. Consult pole specification sheet for additional details. FAO (No visible change) fA L/THON/A COMMERCIAL OUTDOOR One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com RADPT LED L/GHT/NG 0 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 12/15/20 C�6IDIA� ests performed in accordance with IESNA LM-79-08. Data is considered to be representative A D D D rll! G rl I factory for performance data on any configurations not shown here. /30/22 LFILENUMBER:-022-013D ASY 2,924 2 1 2 115 3,022 2 2 2 119 3,095 2 2 2 122 3,168 2 2 2 125 3,168 2 2 2 125 PATH 2,529 2 1 2 100 2,613 2 2 2 103 2,676 2 2 2 105 2,739 2 2 2 108 2,739 2 2 2 108 7 SYM 3,086 2 1 1 121 3,189 2 1 1 126 3,266 2 1 1 129 3,344 2 1 1 132 3,344 2 1 1 132 ASY 4,521 3 2 3 119 4,672 3 2 3 123 4,785 3 2 3 126 4,898 3 2 3 129 4,898 3 2 3 129 P2 38 PATH 3,909 2 2 2 103 4,040 2 2 2 106 4,137 2 2 2 109 4,235 3 2 3 111 4,235 3 2 3 111 SYM 4,772 2 2 1 126 4,931 3 2 1 130 5,050 3 2 1 133 5,169 3 2 1 136 5,169 3 2 1 136 ASY 6,387 3 2 3 119 6,600 3 2 3 123 6,760 3 2 3 126 6,919 3 2 3 129 6,919 3 2 3 129 P3 54 PATH 5,523 3 2 3 103 5,707 3 2 3 106 5,845 3 2 3 109 5,983 3 2 3 112 5,983 3 2 3 112 SYM 6,741 3 2 2 126 6,966 3 2 2 130 7,135 3 2 2 133 7,303 3 2 2 136 7,303 3 2 2 136 ASY 10,150 4 2 4 118 10,489 4 2 4 122 10,742 4 2 4 125 10,996 4 2 4 128 10,996 4 2 4 128 P4 86 PATH 8,777 3 2 3 102 9,070 3 2 3 106 9,289 3 2 3 108 9,509 3 2 3 111 9,509 3 2 3 111 SYM 10,713 3 2 2 125 11,071 3 2 2 129 11,338 3 2 2 132 11,606 3 2 2 135 11,606 3 2 2 135 ASY 14,250 4 2 4 116 14,724 4 2 4 120 15,081 4 3 4 123 15,437 4 3 4 126 15,437 4 3 4 126 PS 123 PATH 12,322 4 2 4 101 12,733 4 3 4 104 13,041 4 3 4 106 13,349 4 3 4 109 13,349 4 3 4 109 SYM 15,040 4 2 3 123 15,541 4 2 3 127 15,917 4 2 3 130 16,293 4 2 3 133 16,293 4 2 3 133 Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). 0`C 32"F 1.06 5"C 41OF 1.05 10"C 50OF 1.04 151C 59"F 1.02 20"C 68"F 1.01 250C 770F 1.00 30% 86T 0.99 35% 95-F 0.98 40% 1041 0.96 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the RADPT LED platform in a 25'C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Projected r Lumen Maintenance 0 25,000 50,000 100,000 P1 1.00 0.96 0.91 0.82 P2 1.00 0.96 0.91 0.82 P3 1.00 0.96 0.91 0.82 P4 1.00 0.96 0.91 0.82 P5 1.00 0.95 0.89 0.78 Electrical Load P1 500 42.8 21.4 Input Current 0.22 0.13 0.11 0.1 0.08 0.06 System Watts 26 26 26 27 25 26 P2 770 43 33.1 Input Current 0.33 0.19 0.16 0.14 0.11 0.08 System Watts 39 39 39 39 38 38 P3 1100 43.2 47.5 Input Current 0.46 0.26 0.23 0.2 0.16 0.12 System Watts 55 54 54 54 54 54 P4 900 87.3 78.6 Input Current 0.73 0.42 0.36 0.32 0.25 0.18 System Watts 87 86 86 86 86 86 PS 1250 88.2 110.2 Input Current 1 0.58 0.5 0.44 0.35 0.25 System Watts 120 119 119 119 120 120 fA L/THON/A COMMERCIAL OUTDOOR One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com RADPT LED LAGHT/NG 0 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. Rev. 12/15/20 RSX2 LED Area Luminaire APPROVED 06/30/22 - A DATL NIGHTTIME FRIENDLY nC ca US r mt 1 ' FILE NUTA"ILA-2M2 0130 Buy.. Specifications EPA 0.69 ft2 (0.06 m2 ) (ft2@0°): w Length: 29.3" (74.4 cm) ccm� (SPA mount) Width: 13.4" (34.0 cm) f ` Tr Height: 3.0" (7.6 cm) Main Body 7.2" (18.3 cm)Arm Weight: 30.0 Ibs (13.6 kg) (SPA mount) Number Notes Type ... a ie Tab key or mouse over the page to see all interactive elements. Introduction The new RSX LED Area family delivers maximum value by providing significant energy savings, long life and outstanding photometric performance at an affordable price. The RSX2 delivers 11,000 to 31,000 lumens allowing it to replace 250W to 1000W HID luminaires. The RSX features an integral universal mounting mechanism that allows the luminaire to be mounted on most existing drill hole patterns. This "no -drill" solution provides significant labor savings. An easy -access door on the bottom of mounting arm allows for wiring without opening the electrical compartment. A mast arm adaptor, adjustable integral slipfitter and other mounting configurations are available. • EXAMPLE: RSX2 LED P6 40K R3 MVOLT SPA DDBXD RSX2 LED RSX2 LED P1 P2 30K 3000K 40K 4000K R2 Type 2Wide R3 Type 3Wide JMVOLT (120V-277V)Z HVOLT (347V-48OV)3 P3 50K 5000K 113S Type 3Short VOLT (277V-48OV)" P4 R4 Type4Wide (use specific voltage for P5 114S Type 4Short options as noted) P6 R5 Type SWide ' 1201 2771 RSS Type 5 Short' 2081 3471 AFR Automotive Front Row 2403 4801 AFRR90 Automotive Front Row Right Rotated AFRL90 Automotive Front Row Left Rotated Shipped Installed HS House -side shield 7 PE Photocontrol, button style 1,9 PEX Photocontrol external threaded, adjustable 1,11 PER7 Seven -wire twist -lock receptacle only (no controls)'"•'2,` CE34 Conduit entry 3/4"NPT(Qty2) SF Single fuse (120, 277, 347) 1 DF Double fuse (208, 240, 480)1 SPD20KV 20KVSurge pack 10KVstandard) FAO Held adjustable output9,13 DMG 0-10V dimming extend out back of housing for external control (control ordered separate) 9,13 DS Dual switching 914 Shipped Installed PA Square pole mounting (3.0" min. SQ pole for 1 at 90° 3.5" min. SQ pole for 2 3 4 at 90°) RPA Round pole mounting (3.2" min. dia. RND pole fort, 3, 4at90°, 3.0" min. dia. RND pole for 1 at 90°, 2 at 180°, 3 at 120°) MA Mast arm adaptor (fits 2-3/8" OD horizontal tenon) IS Adjustable slipfitter (fits 2-3/8"CID tenon) 6 WBA Wall bracket' WBAS( Wall I bracket with surface conduit box AASP Adjustable tilt arm square pole mounting e AARP Adjustable tilt arm round pole mounting 6 AAWB Adjustable tilt arm with walIbracket b AAWSC Adjustable tilt arm wall bracket and surface conduit box *Standalone and Networked Sensors/Controls (factory default settings, see table page 9) NLTAIR2 AlghtAIR generation 2111sae PIRHN Networked, Bi-Level motion/ambient sensor (for use with NLTAIR2)13,14,17 BAA Buy America(n) Act Compliant *Note: PIRHN with nLight Air can be used as a standalone dimming sensor with out -of -box settings or as a wireless networked solution. See factory default settings table. Sensor coverage pattern is affected when luminaire is tilted. Shipped Separately (requires some field assembly) EGS External glare shield 6 EGFV External glare full visor (360'around light aperture) ' BS Bird spikes 18 DDBXD DBLXD DNAXD DWHXD DDBTXD DBLBXD DNATXD DWHGXD Dark Bronze Black Natural Aluminum White Textured Dark Bronze Textured Black Textured Natural Aluminum Textured White '. Llril /A One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www-acuitybrands.com Lithonia RSX2 Area LED Rev.05/11/21 L/GHT/NG © 2011-2021 Acuity Brands Lighting, Inc. All rights reserved. Page 1 of 9 COMMERCIAL OUTDOOR okE IDI� IA RS APPROVED ield(includes 2 shields) RS 06/30/22 d (specify finish) RS DAB' ields for AFR rotated optics (includes 2 shields) RS FILE NUMBER:^zozzoiao isor(spedfyfinish) RS pole adaptor plate (specify fi nish) RSXWBA (FI N ISH) U RSX WBA wall bracket(specifyfinish)' RSXS(B (FI N ISH) U RSX Surfaceconduit box (specifyfinish,for use with WBA, WBA not included) DLL127F 1.5A Photocell-SSL twist -lock (120-277V)" DLL347F 1.5 CUL1U Photocell-SSL twist-lock(347V)" DLL480F 1.5 CUL JU Photocell-SSL twist -lock (480V)" DSHORT SBKU Shorting cap" House Side Shield NOTES 1 Any Type 5 distribution, is not available with WBA. 2 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). 3 HVOLT driver operates on any line voltage from 347-480V (50/60 Hz). 4 XVOLT driver not available with P1. XVOLT driver operates on any line voltage from 277V-480V (50/60 Hz). XVOLT not available with fusing (SF or DF) and not available with PE or PEX. 5 Single fuse (SF) requires 120V, 277V or 347V. Double fuse (DF) requires 208V, 240V or 480V 6 Maximum tilt is 90" above horizontal. 7 It may be ordered as an accessory. 8 Requires MVOLT or 347V 9 Not available in combination with other light sensing control options (following options cannot be combined: PE, PEX, PER7, FAO, DMG, DS, PIRHN). 10 Requires 120V, 208V, 24OV, or 277V. External Glare Shield 11 Twistlock photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Shorting Cap included. Dimming leads capped for future use. 12 For units with option PERT, the mounting must be restricted to +/- 45° from horizontal aim per ANSI C136.10-2010. 13 Two or more of the following options cannot be combined including DMG, DS, PER7, FAO and PIRHN. 14 DS only available on performance package P5 and P6. 15 Must be ordered with PIRHN. 16 Requires MVOLT or HVOLT. 17 Must be ordered with NLTAIR2. For additional information on PIRHN visit here. 18 Must be ordered with fixture for factory pre -drilling. 19 Requires luminaire to be specified with PER7 option. Ordered and shipped as a separate line item from Acuity Brands Controls. External 360 Full Visor Accessories including bullhorns, cross arms and other adpaters are available under the accessories tab at Lithonia's Outdoor Poles and Arms product page. Click here to visit Accessories. HANDHOLE ORIENTATION C D B A Handhole RSX POLE DRILLING temp 2. RSX STANDARD ARM &ADJUSTABLE ARM 5 Round Tenon Mount - Pole Top Slipfitters 2-3/8" RPA, AARP AS3-5190 AS3-5280 AS3-5290 AS3-5320 AS3-539D AS3-5490 2-7/8" RPA,AARP AST25-190 AST25-280 AST25-290 AST25-320 AST25-390 AST25-490 4" RPA,AARP AST35-190 AST35-280 AST35-290 AST35-320 AST35-390 AST35-490 Drill/Side Location by Configuration Type 6 AIN&ANIMY M& + Head Location Side Side B&D Side B&C Round Pole Only Side B, C&D Side A,B,C&D #8 Drill Nomenclature DM19AS DM28AS DM29AS DM32AS DM39AS DM49AS RSX2 - Luminaire EPA *Includes luminaire and integral mounting arm. Other tenons, arms, brackets or other accessories are not included in this EPA data. r Mounting Ty e Ing Ty7pT171t SPA -Square Pole Adaptor 0. 0.69 1.22 1.27 1.8 1.61 2.39 ME 1JgTT 1.37 2.06 2.74 RPA - Round Pole Adaptor 0.74 1.27 1.37 1.9 1.71 2.49 1.42 2.16 2.84 MA - Mast Ann Adaptor 0.61 1.14 1.11 1.64 1.45 2.23 1.29 1.9 2.58 0. 0.69 1.22 1.27 1.8 1.61 2.39 1.37 2.06 2.74 10° 0.53 1.06 1.05 1.58 1.37 2.08 1.06 1.59 2.12 20° 0.52 1.02 1.03 1.52 1.33 2.02 1.03 1.55 2.07 0.64 1.11 1.18 1.63 1.45 2.21 1.27 1.91 2.54 I5- Integral Slipfitter [E40 0.81 1.21 1.35 1.74 1.65 2.39 1.62 2.43 3.23 AASP/AARP- Adjustable 45° 0.91 1.2S 1.5 1.81 1.75 2.48 1.82 2.73 3.64 Ann Square/Round Pole 50° 60° 1.34 1.83 2.17 2.61 2.56 3.62 2.68 4.02 5.36 2.2 2.97 357 4.24 4.17 5.89 4.41 6.61 8.82 70° 2.86 4.13 4.7 5.89 5.71 8.21 5.71 857 11.42 80° 3.4 5.13 5.67 7.34 7.09 10.21 6.79 10.19 13.59 90° 3.85 5.96 6.55 858 8.31 11.88 7.70 11.56 15.41 Lithonia RSX2 Area LED '. L/THON/A One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • WIAW.acuitybrands.com Rev.05/11/21 L/GHT/NG © 2011-2021 Acuity Brands Lighting, Inc. All rights reserved. Page 2 of 9 COMMERCIAL OUTDOOR To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting's RSX Area homepage. 'R TT;;1111��TT lam- 1 J E ID w LED P6 40K. Distances are in units of mounting height (30'). 0 1 2 3 4 4 3 2 1 0 1 2 3 4 4 3 2 1 0 1 2 3 4 4 3 2 1 0 1 2 3 APPROVED 1 1 4 3 DATE: 06/30/22 2 NLFN()tABERA-2022-0130 �� 1 0 -1 -1 -2 .2 -3 3 R2 ; 4 3 2 1 0 1 2 3 4 4 3 2 1 0 2 3 a I A1.1 Performance Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from 0-50°C (32-122°F). Ambient1 32OF Multiplier 1.05 SIC 41"F 1.04 10"C 50°F 1.03 1 SIC 59°F 1.02 200C 68°F 1.01 25"C 770F 1.00 30'C 86°F 0.99 35`C 95OF 0.98 40"C 104°F 0.97 45°C 1130F 0.% 50°C 1227 0.95 4 3 2 1 -2 .3 4 4 3 3 z z 1 1 4 i o .2 -2 -3 3 a R4 s 4 3 2 1 0 1 2 3 3 2 0 -, -2 3 Electrical Load 4 3 2 1 0 1 2 3 1 AFRR90 Performance Package System Watts (W) 120V 208V Current 240V (A) 277V 347V 480V P1 71 W 0.59 0.34 0.30 0.26 020 0.15 P2 111 W 0.93 0.53 0.46 0.40 032 0.23 P3 147W 1.23 0.70 0.61 0.53 0.42 0.31 P4 187W 1.55 0.90 0.78 0.68 053 0.38 P5 21OW 1.75 1.01 0.87 0.76 0.60 0.44 P6 244W 2.03 1.17 1.01 0.88 0.70 0.51 Projected LED Lumen Maintenance 50,000 75,000 100,000 >0.92 Values calculated according to IESNA TM-21-11 methodology and valid up to 40°C. '. LIMMIAIA One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www-acuitybrands.com Lithonia RSX2Area LED Rev.05/11/21 L/GHMUM © 2011-2021 Acuity Brands Lighting, Inc. All rights reserved. Page 3 of 9 COMMERCIAL OUTDOOR RSX2 LED Area Luminaire APPROVED 06/30/22 - A DATL NIGHTTIME FRIENDLY nC ca US r mt 1 ' FILE NUTA"ILA-2M2 0130 Buy.. Specifications EPA 0.69 ft2 (0.06 m2 ) (ft2@0°): w Length: 29.3" (74.4 cm) ccm� (SPA mount) Width: 13.4" (34.0 cm) f ` Tr Height: 3.0" (7.6 cm) Main Body 7.2" (18.3 cm)Arm Weight: 30.0 Ibs (13.6 kg) (SPA mount) Number Notes Type ... a ie Tab key or mouse over the page to see all interactive elements. Introduction The new RSX LED Area family delivers maximum value by providing significant energy savings, long life and outstanding photometric performance at an affordable price. The RSX2 delivers 11,000 to 31,000 lumens allowing it to replace 250W to 1000W HID luminaires. The RSX features an integral universal mounting mechanism that allows the luminaire to be mounted on most existing drill hole patterns. This "no -drill" solution provides significant labor savings. An easy -access door on the bottom of mounting arm allows for wiring without opening the electrical compartment. A mast arm adaptor, adjustable integral slipfitter and other mounting configurations are available. • EXAMPLE: RSX2 LED P6 40K R3 MVOLT SPA DDBXD RSX2 LED RSX2 LED P1 P2 30K 3000K 40K 4000K R2 Type 2Wide R3 Type 3Wide JMVOLT (120V-277V)Z HVOLT (347V-48OV)3 P3 50K 5000K 113S Type 3Short VOLT (277V-48OV)" P4 R4 Type4Wide (use specific voltage for P5 114S Type 4Short options as noted) P6 R5 Type SWide ' 1201 2771 RSS Type 5 Short' 2081 3471 AFR Automotive Front Row 2403 4801 AFRR90 Automotive Front Row Right Rotated AFRL90 Automotive Front Row Left Rotated Shipped Installed HS House -side shield 7 PE Photocontrol, button style 1,9 PEX Photocontrol external threaded, adjustable 1,11 PER7 Seven -wire twist -lock receptacle only (no controls)'"•'2,` CE34 Conduit entry 3/4"NPT(Qty2) SF Single fuse (120, 277, 347) 1 DF Double fuse (208, 240, 480)1 SPD20KV 20KVSurge pack 10KVstandard) FAO Held adjustable output9,13 DMG 0-10V dimming extend out back of housing for external control (control ordered separate) 9,13 DS Dual switching 914 Shipped Installed PA Square pole mounting (3.0" min. SQ pole for 1 at 90° 3.5" min. SQ pole for 2 3 4 at 90°) RPA Round pole mounting (3.2" min. dia. RND pole fort, 3, 4at90°, 3.0" min. dia. RND pole for 1 at 90°, 2 at 180°, 3 at 120°) MA Mast arm adaptor (fits 2-3/8" OD horizontal tenon) IS Adjustable slipfitter (fits 2-3/8"CID tenon) 6 WBA Wall bracket' WBAS( Wall I bracket with surface conduit box AASP Adjustable tilt arm square pole mounting e AARP Adjustable tilt arm round pole mounting 6 AAWB Adjustable tilt arm with walIbracket b AAWSC Adjustable tilt arm wall bracket and surface conduit box *Standalone and Networked Sensors/Controls (factory default settings, see table page 9) NLTAIR2 AlghtAIR generation 2111sae PIRHN Networked, Bi-Level motion/ambient sensor (for use with NLTAIR2)13,14,17 BAA Buy America(n) Act Compliant *Note: PIRHN with nLight Air can be used as a standalone dimming sensor with out -of -box settings or as a wireless networked solution. See factory default settings table. Sensor coverage pattern is affected when luminaire is tilted. Shipped Separately (requires some field assembly) EGS External glare shield 6 EGFV External glare full visor (360'around light aperture) ' BS Bird spikes 18 DDBXD DBLXD DNAXD DWHXD DDBTXD DBLBXD DNATXD DWHGXD Dark Bronze Black Natural Aluminum White Textured Dark Bronze Textured Black Textured Natural Aluminum Textured White '. Llril /A One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www-acuitybrands.com Lithonia RSX2 Area LED Rev.05/11/21 L/GHT/NG © 2011-2021 Acuity Brands Lighting, Inc. All rights reserved. Page 1 of 9 COMMERCIAL OUTDOOR okE IDI� IA RS APPROVED ield(includes 2 shields) RS 06/30/22 d (specify finish) RS DAB' ields for AFR rotated optics (includes 2 shields) RS FILE NUMBER:^zozzoiao isor(spedfyfinish) RS pole adaptor plate (specify fi nish) RSXWBA (FI N ISH) U RSX WBA wall bracket(specifyfinish)' RSXS(B (FI N ISH) U RSX Surfaceconduit box (specifyfinish,for use with WBA, WBA not included) DLL127F 1.5A Photocell-SSL twist -lock (120-277V)" DLL347F 1.5 CUL1U Photocell-SSL twist-lock(347V)" DLL480F 1.5 CUL JU Photocell-SSL twist -lock (480V)" DSHORT SBKU Shorting cap" House Side Shield NOTES 1 Any Type 5 distribution, is not available with WBA. 2 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). 3 HVOLT driver operates on any line voltage from 347-480V (50/60 Hz). 4 XVOLT driver not available with P1. XVOLT driver operates on any line voltage from 277V-480V (50/60 Hz). XVOLT not available with fusing (SF or DF) and not available with PE or PEX. 5 Single fuse (SF) requires 120V, 277V or 347V. Double fuse (DF) requires 208V, 240V or 480V 6 Maximum tilt is 90" above horizontal. 7 It may be ordered as an accessory. 8 Requires MVOLT or 347V 9 Not available in combination with other light sensing control options (following options cannot be combined: PE, PEX, PER7, FAO, DMG, DS, PIRHN). 10 Requires 120V, 208V, 24OV, or 277V. External Glare Shield 11 Twistlock photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Shorting Cap included. Dimming leads capped for future use. 12 For units with option PERT, the mounting must be restricted to +/- 45° from horizontal aim per ANSI C136.10-2010. 13 Two or more of the following options cannot be combined including DMG, DS, PER7, FAO and PIRHN. 14 DS only available on performance package P5 and P6. 15 Must be ordered with PIRHN. 16 Requires MVOLT or HVOLT. 17 Must be ordered with NLTAIR2. For additional information on PIRHN visit here. 18 Must be ordered with fixture for factory pre -drilling. 19 Requires luminaire to be specified with PER7 option. Ordered and shipped as a separate line item from Acuity Brands Controls. External 360 Full Visor Accessories including bullhorns, cross arms and other adpaters are available under the accessories tab at Lithonia's Outdoor Poles and Arms product page. Click here to visit Accessories. HANDHOLE ORIENTATION C D B A Handhole RSX POLE DRILLING temp 2. RSX STANDARD ARM &ADJUSTABLE ARM 5 Round Tenon Mount - Pole Top Slipfitters 2-3/8" RPA, AARP AS3-5190 AS3-5280 AS3-5290 AS3-5320 AS3-539D AS3-5490 2-7/8" RPA,AARP AST25-190 AST25-280 AST25-290 AST25-320 AST25-390 AST25-490 4" RPA,AARP AST35-190 AST35-280 AST35-290 AST35-320 AST35-390 AST35-490 Drill/Side Location by Configuration Type 6 AIN&ANIMY M& + Head Location Side Side B&D Side B&C Round Pole Only Side B, C&D Side A,B,C&D #8 Drill Nomenclature DM19AS DM28AS DM29AS DM32AS DM39AS DM49AS RSX2 - Luminaire EPA *Includes luminaire and integral mounting arm. Other tenons, arms, brackets or other accessories are not included in this EPA data. r Mounting Ty e Ing Ty7pT171t SPA -Square Pole Adaptor 0. 0.69 1.22 1.27 1.8 1.61 2.39 ME 1JgTT 1.37 2.06 2.74 RPA - Round Pole Adaptor 0.74 1.27 1.37 1.9 1.71 2.49 1.42 2.16 2.84 MA - Mast Ann Adaptor 0.61 1.14 1.11 1.64 1.45 2.23 1.29 1.9 2.58 0. 0.69 1.22 1.27 1.8 1.61 2.39 1.37 2.06 2.74 10° 0.53 1.06 1.05 1.58 1.37 2.08 1.06 1.59 2.12 20° 0.52 1.02 1.03 1.52 1.33 2.02 1.03 1.55 2.07 0.64 1.11 1.18 1.63 1.45 2.21 1.27 1.91 2.54 I5- Integral Slipfitter [E40 0.81 1.21 1.35 1.74 1.65 2.39 1.62 2.43 3.23 AASP/AARP- Adjustable 45° 0.91 1.2S 1.5 1.81 1.75 2.48 1.82 2.73 3.64 Ann Square/Round Pole 50° 60° 1.34 1.83 2.17 2.61 2.56 3.62 2.68 4.02 5.36 2.2 2.97 357 4.24 4.17 5.89 4.41 6.61 8.82 70° 2.86 4.13 4.7 5.89 5.71 8.21 5.71 857 11.42 80° 3.4 5.13 5.67 7.34 7.09 10.21 6.79 10.19 13.59 90° 3.85 5.96 6.55 858 8.31 11.88 7.70 11.56 15.41 Lithonia RSX2 Area LED '. L/THON/A One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • WIAW.acuitybrands.com Rev.05/11/21 L/GHT/NG © 2011-2021 Acuity Brands Lighting, Inc. All rights reserved. Page 2 of 9 COMMERCIAL OUTDOOR To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting's RSX Area homepage. 'R TT;;1111��TT lam- 1 J E ID w LED P6 40K. Distances are in units of mounting height (30'). 0 1 2 3 4 4 3 2 1 0 1 2 3 4 4 3 2 1 0 1 2 3 4 4 3 2 1 0 1 2 3 APPROVED 1 1 4 3 DATE: 06/30/22 2 NLFN()tABERA-2022-0130 �� 1 0 -1 -1 -2 .2 -3 3 R2 ; 4 3 2 1 0 1 2 3 4 4 3 2 1 0 2 3 a I A1.1 Performance Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from 0-50°C (32-122°F). Ambient1 32OF Multiplier 1.05 SIC 41"F 1.04 10"C 50°F 1.03 1 SIC 59°F 1.02 200C 68°F 1.01 25"C 770F 1.00 30'C 86°F 0.99 35`C 95OF 0.98 40"C 104°F 0.97 45°C 1130F 0.% 50°C 1227 0.95 4 3 2 1 -2 .3 4 4 3 3 z z 1 1 4 i o .2 -2 -3 3 a R4 s 4 3 2 1 0 1 2 3 3 2 0 -, -2 3 Electrical Load 4 3 2 1 0 1 2 3 1 AFRR90 Performance Package System Watts (W) 120V 208V Current 240V (A) 277V 347V 480V P1 71 W 0.59 0.34 0.30 0.26 020 0.15 P2 111 W 0.93 0.53 0.46 0.40 032 0.23 P3 147W 1.23 0.70 0.61 0.53 0.42 0.31 P4 187W 1.55 0.90 0.78 0.68 053 0.38 P5 21OW 1.75 1.01 0.87 0.76 0.60 0.44 P6 244W 2.03 1.17 1.01 0.88 0.70 0.51 Projected LED Lumen Maintenance 50,000 75,000 100,000 >0.92 Values calculated according to IESNA TM-21-11 methodology and valid up to 40°C. '. LIMMIAIA One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www-acuitybrands.com Lithonia RSX2Area LED Rev.05/11/21 L/GHMUM © 2011-2021 Acuity Brands Lighting, Inc. All rights reserved. Page 3 of 9 COMMERCIAL OUTDOOR