Loading...
HomeMy WebLinkAboutA-2022-0081 Design Review Reply - 6-15-2022 V1CUEIDR IAy APPROVED AIGHTLINE DATE 06/29/22 FILFNUMBER:A-zozz -o 11 k ARCHITECTS June 17T", 2022 RE: NEW BUILDING - JK QUILTS DESIGN REVIEW REPLY Dear Design Review, Below are responses to the following design review comments. Attached are the revised sheets reflecting any modifications or comments. REVISED SHEETS ATTACHED: ELEVATION 1 ELEVATION 2 LANDSCAPE PLAN SITE PLAN FRONT ELEVATION Q: Un-textured concrete panels and prefabricated steel panels are prohibited as field materials for building facades except when used with a minimum of two other qualifying field materials and meeting all other standard fenestration and material requirements. Please give calculations of south and west elevations. All metal panels count. If you are going to use metal paneling, you need to provide at least two other qualifying field materials (>20% each). Please provide this calculation on the south and west (visible from street) elevations. A: The Front (south) elevation has been revised for material percentages. Windows & Stucco are to be considered the other two qualifying materials above 20%. The Side (West) elevation has been revised for material percentages. Stone & Stucco are to be considered the two 20% materials. MATERIAL CALCULATIONS: (FRONT SOUTH ELEVATION) MATERIAL SF. STONE: 500 sf 16.3 STUCCO: 693 sf 22.3 WINDOWS: 1,039 sf 33.6 METAL PANELS: 862 sf 28.0 TOTAL: 3,094 sf 100 MATERIAL CALCULATIONS: (WEST ELEVATION) MATERIAL SF. STONE: 317 sf 20.1 STUCCO: 420 sf 26.5 WINDOWS: 85 sf 5.4 METAL PANELS: 763 sf 48.2 TOTALS: 1,583 sf 100 WEST ELEVATION Q: This is a very visible elevation. How does it meet ASM 3.3D and or 3.3E in regard to fenestration or fenestration alternative? West side is very visible from street. See comments on elevation 1 regarding metal paneling. It cannot be used as afield material unless there are at least two other field materials (>20% each) or a design exception granted. Please provide % calculations, revise to meet standards or request design exception. A: West elevation has been modified to address material percentages. 3.3E shall be used for material changes. Please note that due to the building shape (see floor plan) the left half and right half of the west elevation drawing are on substantially different planes. Viewing the building `straight on' as shown in the elevation will not be optically perceived in reality. Very visible elevation. Consistently incorporate at least two (2) architectural STRAIGHTLINE ARCHITECTS 1 4521 S. Cloverdale Road, Ste. 102 1 Boise, Idaho 83709 1 P: 208-991-0855 1 www.StraightlineArchitects.com CUEIDR IAN,-- APPROVED DATE 06/29/22 FILE NUMBER: ^-2D22-1 to the building design that are scale, to include: fenestration rchitectural elements such as ledges, canopies; material or pattern banding, or detailing (see Pedestrian Scale definition). - How is this met at the west? A: Fenestration patterns and lighting have been added to address pedestrian scale. For at least 30% of applicable facades use any combination of concrete, masonry, stone, or unique variation of color, texture, or material, at least 10-inches in height, around the base of the building. May alternatively incorporate other architectural features such as ledges, fagade reveals, ground level fenestration, raised planters, or landscaping elements within 3-feet of finished grade. How is this met on this elevation? A: Stone wainscot has been added to address requirement. LANDSCAPE PLAN 11-38-5. Lawn and turf areas shall not comprise more than fifty (50) percent of the total landscaped areas and shall consist of water conserving grasses, including, but not limited to, buffalo grass, blue gamma grass, compact fescue, Xerilawn, turf type tall fescue and/or rhizomatous tall fescue" Please indicate the percentage of lawn on the landscape table. A: Total Planted ratios have been calculated and placed on the Landscape Plan. The planted area along the north side of the building has been changed from grass sod to planters as required to adhere to the 'Less than 50%' overall planted area. How are ground mounted equipment being screened? A: The equipment will be screened by a solid half wall faced with metal panels. Keyed note '9' has been changed to address this. Provide a five-foot wide minimum landscape buffer adjacent to parking, loading, or other paved vehicular use areas, including driveways, vehicle sales areas, truck parking areas, bus parking areas, and vehicle storage areas. The perimeter landscape buffer shall be planted with one Class 11 or Class III tree per thirty-five (35) linear feet and shrubs, lawn, or other vegetative ground cover. Is the minimum landscape density (trees) being met at the east? A: Trees & shrubs have been added to the 5' wide perimeter landscape buffer along the east property line. What does the stippling represent? Not shown in legend. A: Keyed note V indicates vision triangle. SITE PLAN When a bumper overhangs onto a sidewalk or landscape area, the parking stall dimensions may be reduced two (2) feet in length if two (2) feet is added to the width of the sidewalk or landscaped area planted in ground cover. Minimum width of sidewalk is 5' and you cannot provide parking spaces less than 17' in length A: Parking Stalls have been expanded to 19' deep. See revised siteplan. Respectfully, Scott Marshall, AIA-NCARB Principal — Straightline Architects Idaho — Oregon - Montana STRAIGHTLINE ARCHITECTS 1 4521 S. Cloverdale Road, Ste. 102 1 Boise, Idaho 83709 1 P: 208-991-0855 www.StraightlineArchitects.com