Loading...
HomeMy WebLinkAboutLEVEL 1 FLOOR PLAN V1DWT—,)- FLOOR PLAN GENERAL NOTES: APPROVED 1. DRAWINGS &SPECIFICATIONS ARE COMPLIMENTARY ■ ■ COMPONENTS OF THE CONTRACT DOCUMENTS, REVIEW osrz7rzz ChM, ALL DRAWINGS AND SPECIFICATIONS FOR THE fuCOMPLETE SCOPE OF WORK. NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION IF INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE DISCOVERED. 2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION BEFORE Babcock Design PROCEEDING WITH CONSTRUCTION. 3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES, TO GRIDLINES OR TO FACE OF FRAMING UNLESS NOTED Boise OTHERWISE. 800 W MAIN STREET 4. UNLESS NOTED OTHERWISE CLEAR DIMENSIONS INDICATE DIMENSION BETWEEN FINISHES. SUITE 940 5. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF BOISE, ID 83702 DISCREPANCIES IN THE DOCUMENTS, AND OF ANY FIELD 208.424.7675 CONDITIONS THAT DEVIATE FROM THE DOCUMENTS. b. THE ARCHITECT'S APPROVAL MUST BE OBTAINED FOR ANY DEVIATIONS FROM THE CONSTRUCTION DOCUMENTS, Salt Lake City/ INCLUDING BUT NOT LIMITED TO CHANGES IN 52 Exchange Place DIMENSIONS, DESIGN, MATERIALS, PRODUCTS, AND Salt Lake City, UT 84111 FINISHES. IN NO CASE MAY THE CONTRACTOR MAKE 1 2 3 4 THESE CHANGES WITHOUT THE APPROVAL OF THE 801.531.1 144 ARCHITECT. 7. SHOP DRAWINGS AND OTHER SUBMITTALS ARE TO BE babcockdesign.com 86- 3" PRESENTED TO THE ARCHITECT FOR REVIEW PRIOR TO EXECUTION OF WORK. ALLOW APPROPRIATE TIME FOR 18'-31/2" 49'-0" 18'-111/2" REVIEW. sheet information: 8. SEE DOOR AND WINDOW SCHEDULES FOR SIZES, TYPES, revisions: 0 3'-53/4" 11'-4" 3'-53/4" 10,-11/2" 4'-4" 3'-81/2" 6'-4" 9'-6" 6'-4" 2'-8" 6'-0" 9'-0" 9'-111/2" AND FINISHES, HARDWARE, ETC. 11 9. FOR BUILDING CODE REQUIREMENTS OR FIRE/SMOKE num- description date 18'- 11 1/2" REQUIREMENTS, SEE'G' SHEETS. 2 10. ALL FIRE RATED WALLS TO BE LABELED AS FIRE RATED. 1 REVIEW COMMENT RESPONSES 4/26/22 LABEL TO BE PLACED ABOVE CEILING LINE. 5 1 /2 3' - 0 1/4-1 A301 DR002 3 11. SEE WALL TYPE CONSTRUCTION DETAILS ON SHEET A611 15 3' - 0 1 /4" 5 1 /2" A301 1� AND ADDITIONAL DETAILS ON SHEETS A612 AND A613 A561 7 HEM STOR CHEM STOR FOR WALL TERMINATIONS, ETC. 12. HINGE SIDE OF DOORS ARE LOCATED 4' FROM _ _ _ _ W4 _ _ _ _ _ _ _ _ _ _ A401 120 111 _� ADJACENT WALL UNLESS NOTED OTHERWISE. uo • 13. ANY COLUMN FURRING TO BE TIGHT TO COLUMN UNO. C L11 l C 14. ALL CONSTRUCTION SHALL CONFORM TO AND STRICTLY COMPLY WITH ALL APPLICABLE CODES, COVENANTS, o QA�103 0 b K6 RESTRICTIONS, AND OTHER REQUIREMENTS OF THE 11 m 2 o AUTHORITY HAVING JURISDICTION OVER THE PROJECT. C� A501 A503 15. IN NO EVENT SHALL THE CONTRACTOR SUBMIT A M RECEPTION I L121 J, I W6 STANDARD CONSTRUCTION DETAIL FOR A DETAIL 4 N SPECIFIED IN THESE DOCUMENTS WITHOUT THE / 117 _ ° 0 APPROVAL IN WRITING FROM THE ARCHITECT. THE date: 05.24.2022 9'-91/2" T-91/2" _ ° ' I � CONTRACTOR SHALL BRING ALL WORK INTO _ CONFORMITY WITH THE CONSTRUCTION DOCUMENTS, project number. 20511 K6 B 6 AS THE ARCHITECT ORDERS, BEFORE APPROVAL OF THAT project status: BID SET K6 FIRE RISER _ / W3 ADMIN ° o 6 PORTION OF THE PROJECT WILL BE GRANTED. original drawing s24•.38 121 ® - 9 A411 - 16. BRACE ALL CEILINGS AND NON -LOAD BEARING WALLS current as of: 5/25/20229:51:04 AM 128 "s co � I I / L112 AS REQUIRED. menf—tionnnocontemrepre tadh—i,1,e° d.,eabyl— A541 6 / 17 R POWER meo,chneas�°:mtmem:ot serr�ce o°do,emop, ,0y fB bcock 1 K6 B • POOL EQUIP SYSTEM LOCATIONS AND D�Ie°°° ey �e °Ce°mOe"d° a""e3 de" few°° bCeS COORDINATE WITH ELECTRICAL DRAWINGS FO nu DATA, AND OTHERco—1 t.c n c 9 9 d d° _ _ - A401 _ _ a 3 \ — _ / 6.1 personnel only1 ordan wilh this police. They intended for use o C, L.J o 112 REQUIREMENTS. only for mpproipctroeciepdpm°,,t°ocu:pdfor noome,ppmo;e« .�• U '� O O MpWincludin9addi,,,p°ormodificotianofine canplered project. 335 SF 18. THE FURNITURE AND OTHER F.F.E. SHOWN ON DRAWINGS WWp d,, pl, m,d, a iffadep,od ed, old, did,ophed o ired. o A411 4 - O anyBshed.uploodpd.eorsmined. diothera,:ola, dimtomed to pd,, 9 4 \ O z — — IS SCHEMATIC AND IS ONLY TO BE USED FOR REFERENCE len'o9B°bc°it gn,othe eu awmoutmepno, u28 � ONLY. THE CONTRACTOR SHALL COORDINATE THE FINAL O COPYRIGHT O 2019 BABCOCK DESIGN ^t _ _ _ I _ l LOCATION OF ELECTRICAL OUTLETS AND OTHER NEEDS A3 9 .I 1/8" / 12" n301 WITH THE OWNER AND ARCHITECT, PRIOR TO INSTALLATION. rtam p. I_ _ J UNISEX 1 00 -----_—_- - � 1T-6" I ♦♦ BED A/Z -. / I + 0 2 DR002 ♦♦ \G<r••• •,. T�♦♦♦ \ O FIRE RATING LEGEND •� :` ':.°� �w, o 6' 10 AR-98� i N W3 _> _ AMAZON LOCKERS _ ; •�� NON RATED tigFirr• ♦♦♦ ♦♦ .,tb oy�`` 9 - 9 1 /2'' ♦ WLAN ,.r O ♦1 OD ' 0AII '-` : -_ = co ED SMOKE PARTITION NON RATED 21 HALLWAY u3o ^ AMAZON LOCKERS M LL/l'/l'/l'(Llt(lGG7///////////i ( ) ♦♦�.rF pF' \pP♦♦♦♦ 130 1 HR FIRE BARRIER is v L �4iio00 J 51/2' 17-6" j �y LOBBY & LOUNGE aD 1 HR FIRE &SMOKE BARRIERproject information: zr 118 �� ,L133 0 6 `o Z 0000 DR001 2LO u 3 SHEET NOTES r oc v L/J _ _ _ - - - - J NOTE: THESE NOTES APPLY TO THIS SHEET ONLY. p w = U = H� Q z 0 0 2 19 i1#) Q z0 PACKAGES f \/ _ z z a o u 31 K6 133 / - - - - I 1 ROOF ACCESS LADDER J < LEASING K6 a b 131 '� o MAIL / Q 4 L J 2 TOP LOADING WASHER. CFCI. COORDINATE WITH �� O w > MECHANICAL W3 L132 � 124 I 5 L — — 3 DRYER, CFCI. COORDINATE WITH MECHANICAL. U z O b M v I b MAINTENANCE 4 JANITOR SINK - COORDINATE WITH MECHANICAL Z 3 IT � \ � � _ _ / I I • Mb 1 19 � 5 GOLF CART FOOT PRINT. SHOWN FOR CONTEXT. O °D A503 132 ' 12' - 0" 119 6 MAIL BOXES. c 7 AMAZON LOCKERS ° b 7 8 MBG-1 STEEL BAR GRATING, SUPPORT ANGLES AND v W2 124 W6 0 A542 3' DEEP SUMP PIT PER STRUCTURAL DRAWINGS. (H� � OD M I - — — — — — — — — — — - — `r i co n v v v ' L118 M � L UJ ------------- --------- ---- --- W5 -- ----- ------C?-- ------------ 3 W6 DR001 A301 (I� 2 v A301 z 3'-53/4" 11'-4" 3'-53/4" 2'-8" 6'-4" 9'-2" 6'-4" 9'-6" 6'-4" 2'-8" 6'-0" 51/2" 5-81/4" 6'-0" 6'-41/4" 51/2" Q 18'-31/2" 49'-0" 18'- 11 1/2" 7 86- 3" L z Q 1 2 3 4 0 NORTH IY W 0 1 LEVEL 1 - FLOOR PLAN / O J '__I J LU W w J A 112