Groundwater Report V1APPROVED
DATE: 06/22/22
FILE NUMBER: H-2D21-D01D
ATERIALS
=STING &
ISPECTION
12/22/2020
B191818g_gwmonitoring
AN ATLAS COMPANY
;I Services > eotechnical Fngineerinq J J
AllTerra Consulting, LLC
849 East State Street, Suite 104
Eagle, ID 83616
(208) 484-4479
Re:
Dear Mr. Walker:
Groundwater Letter
Linder Holdings Subdivision
2365 Victory Road
Meridian, ID
This letter has been prepared to verify seasonal high groundwater as determined through regular
monitoring unavailable at the time of the previously issued MTI Geotechnical Engineering Report
(13191818g). Descriptions of general site characteristics and the proposed project are available in the
previous report. Unless otherwise noted in this letter, all initial recommendations, limitations, and
warranties expressed in the previous report must be adhered to.
The following table represents groundwater data collected for the site. It should be noted that these
levels will fluctuate from year to year, and are limited to the data collected.
MTI will continue to monitor these wells on a bi-weekly basis. MTI appreciates this opportunity to
be of service to you and looks forward to working with you in the future. If you have questions,
please call (208) 376-4748.
Respectfully Submitted,
Materials Testing & Inspection
Jacob Schlador, P.E.
Geotechnical Engineer
Enclosures:
Groundwater Data
Qao I L
f
Reviewed by: Monica Saculles, P.E.
Senior Geotechnical Engineer
2791 S Victory View Way • Boise, ID 83709 • (208) 376-4748 • Fax (208) 322-6515
www.mti-id.com • mti0oti-id.com
ATERIAIS
E IDR IAN,_- ESTING
\J SPECTION
APPROVED AN ATLAS COMPANY
osizzizz I Services ❑ Geotechnical
DATE
FILE NUMBER: -D -omo
12/22/2020
B191818g_gwmonitoring
❑ Construction Materials Testing ❑ Special Inspections
Groundwater Depth (Feet bgs)
Date Monitored TP-1 TP-6 TP-9 TP-10
10/28/2019
Dry A
Dry A
Dry A
Dry A
12/20/2019
Dry
Dry
Dry
Dry
1/3/2020
Dry
Dry
Dry
Dry
1/17/2020
Dry
Dry
Dry
Dry
2/1/2020
Dry
Dry
Dry
Dry
2/14/2020
Dry
Dry
Dry
Dry
2/28/2020
Dry
Dry
Dry
Dry
3/14/2020
Dry
Dry
Dry
Dry
3/26/2020
Dry
Dry
Dry
Dry
4/11/2020
Dry
Dry
Dry
Dry
4/25/2020
Dry
Dry
Dry
Dry
5/7/2020
Dry
Dry
Dry
Dry
5/22/2020
Dry
Dry
Dry
Dry
6/3/2020
Dry
Dry
Dry
Dry
6/20/2020
Dry
Dry
Dry
Dry
7/3/2020
Dry
Dry
Dry
Dry
7/18/2020
Dry
Dry
Dry
Dry
8/2/2020
Dry
Dry
Dry
Dry
8/15/2020
Dry
Dry
Dry
Dry
8/30/2020
Dry
Dry
Dry
Dry
9/12/2020
Dry
Dry
Dry
Dry
9/25/2020
Dry
Dry
Dry
Dry
10/9/2020
Dry
Dry
Dry
Dry
10/25/2020
Dry
Dry
Dry
Dry
11/7/2020
Dry
Dry
Dry
Dry
11/19/2020
Dry
Dry
Dry
Dry
12/5/2020
Dry
Dry
Dry
Dry
12/18/2020
Dry
Dry
Dry
Dry
Legend:
A Initial reading/depth recorded at time of piezometer installation.
2791 S Victory View Way • Boise, I D 83709 • (208) 376-4748 • Fax (208) 322-6515