Loading...
HomeMy WebLinkAboutLandscape Plan V1PROPOSED BUILDING +/- 73,778 GSF OFFICE AREA 24,346 SF ( 1 3 AREA) 1 1 1 1 2 2 3 3 3 3 3 3 3 3 4 4 5 6 7 7 3 GT 5 QR 2 PC 10 TT 9 PC 4 TT 1 PC 5 GT 1 TT 14 QR 10 PC 3 GT 6 BN 4 BN 3 LANDSCAPE BUFFER REQUIREMENTS: NORTHERN PARKING BUFFER: N/A (SHARED LOT) 10'-0" BUFFER REQUIRED WITH ONE (1) TREE PER 35': @ 673' / 35 = 19 TREES REQUIRED 19 TREES PROVIDED. SOUTHERN PARKING BUFFER: N/A (ADJACENT COMMERCIAL) 10'-0" BUFFER REQUIRED WITH ONE (1) TREE PER 35': @ 523' / 35 = 15 TREES REQUIRED 15 TREES PROVIDED. WESTERN PARKING BUFFER: N/A (CANAL LOT) 10'-0" BUFFER REQUIRED WITH ONE (1) TREE PER 35': @414' / 35 = 12 TREES REQUIRED 12 TREES PROVIDED EASTERN STREET LANDSCAPE BUFFER (S INDUSTRIAL WAY - LOCAL): 10'-0" BUFFER REQUIRED WITH ONE (1) TREE PER 35': @ 403' / 35 = 12 TREES REQUIRED 12 TREES PROVIDED INTERIOR PARKING LANDSCAPING: ONE CLASS II TREE WITH GROUNDCOVER AND SHRUBS PROVIDED FOR EACH ROW OF PARKING. SITE ZONING: C-G ADJACENT ZONING: C-G SETBACKS: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES Call before you dig. Know what's below. R South Landscape Architecture P.C. Dba South Beck & Baird Landscape Architecture P.C. 2002 S. Vista Ave Boise, ID 83705 208.342.2999 Office info@sbbgo.com www.sbbgo.com All rights reserved. Reproduction or use in any form or by any means without written permission of South Landscape Architecture P.C. Dba South Beck & Baird Landscape Architecture P.C. is unlawful and subject to criminal prosecution. No. Date Description THE PROFESSIONAL SERVICES OF THE DESIGN PROFESSIONAL ARE UNDERTAKEN FOR AND ARE PERFORMED IN THE INTEREST OF "THE CLIENT" NO CONTRACTUAL OBLIGATION IS ASSUMED BY THE DESIGN PROFESSIONAL FOR THE BENEFIT OF ANY OTHER PERSON INVOLVED IN THE PROJECT. Design Review F O S C A P E A R C H I T E C T D N A L D E S N E C I L E T A T S I D A H O D . H O J O T E R R N S LA - 16827 L1.1 1. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICH INSURES COMPLETE COVERAGE AND PROPERLY ZONED FOR REQUIRED WATER USES. EACH HYDROZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS. 2. PLANTER BEDS AND LAWN AREAS ARE TO HAVE SEPARATE HYDRO-ZONES. 3. POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 4 INCHES AT LAWN AREAS AND 18" AT PLANTER BEDS. 4. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEM OR POP-UP SPRAY SYSTEM. 5. ELECTRONIC WATER DISTRIBUTION/ TIMING CONTROLLERS ARE TO BE PROVIDED. MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS: a. PRECISE INDIVIDUAL STATION TIMING b. RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES c. AT LEAST ONE PROGRAM FOR EACH HYDROZONE d. SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF e. POWER FAILURE BACKUP FOR ALL PROGRAMED INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO-ZONES. 6. INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO-ZONES. 7. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% HEAD TO HEAD COVERAGE WITH TRIANGULAR SPACING. 8. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES (BUILDINGS, SIDEWALKS, DRIVEWAYS, AND ASPHALT AREAS). 9. PROVIDE MINIMUM (1) QUICK COUPLER VALVE PER EACH (6) AUTOMATIC VALVE ZONES. APPROVE Q.C.V. LOCATIONS WITH LANDSCAPE ARCHITECT. 1. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION. ALL PLANT MATERIAL SHALL BE GRADE #1 OR BETTER. 2. ALL PLANTING BEDS AND TREE WELLS IN LAWN AREAS (WELLS TO BE 3' IN DIAMETER) SHALL BE COVERED WITH A MINIMUM OF 3" DEPTH OF BLACK AND TAN ROCK MULCH. SUBMIT SAMPLE FOR APPROVAL BY OWNER. 3. ALL LAWN AREAS SHALL BE SODDED WITH 100% TURF TYPE TALL FESCUE (FESTUCA ARUNDINACIA). CONTRACTOR SHALL VERIFY AND MATCH THE VARIETY EXISTING IN THE ADJACENT DEVELOPMENT. 4. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAME SIZE AND SPECIES AT NO COST TO THE OWNER. 5. PLANTING BACKFILL FOR TREES AND PLANTING BEDS SHALL BE 5 PARTS TOPSOIL AND 1 PART COMPOST WITH STRAW. STAKE ALL TREES PER DETAILS. 6. ALL LAWN AREAS SHALL HAVE 6" OF TOPSOIL AND ALL PLANTING BEDS SHALL HAVE 12" OF TOPSOIL (MINIMUM). TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS, OR OTHER FOREIGN MATERIAL LARGER THAN 1" IN ANY DIMENSION, A PH FROM 5.5 TO 7.0. TOP SOIL FROM SITE SHALL BE USED, IF MEETING THESE STANDARDS. PLACE 1/2" COMPOST OVER ALL LANDSCAPED AREAS AND ROTOTILL INTO TOP 4". SPREAD, COMPACT, AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE, 1" BELOW SURFACE OF WALKS AND CURBS IN AREAS TO BE SODDED AND 3" IN PLANTING BED AREAS. 7. FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM" PLANTING TABLETS, 21 GRAM. QUANTITY PER MANUFACTURER'S RECOMMENDATION. 8. PLANT MATERIAL SHALL NOT BE SUBSTITUTED WITHOUT THE WRITTEN PERMISSION OF OWNER. SUBMIT NAMES OF THREE SUPPLIERS CONTACTED IF SUBSTITUTION IS REQUESTED AND PLANT MATERIAL SPECIFIED IS NOT AVAILABLE. 9. SHRUB PLANTING BEDS SHALL BE SHOVEL EDGED TO CREATE A DISTINCT SEPARATION OF LANDSCAPE TYPES. 10. IMMEDIATELY CLEAN UP ANY TOPSOIL, OR OTHER DEBRIS ON SITE CREATED FROM LANDSCAPE OPERATION AND DISPOSE OF PROPERLY OFF SITE. 11. ALL LANDSCAPE AREAS SHALL HAVE AN STATE OF THE ART AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICH INSURES COMPLETE COVERAGE AND IS PROPERLY ZONED FOR REQUIRED WATER USES AND HAS A WEATHER STATION CAPABLE OF TURNING OFF FOR RAIN/FREEZE EVENTS. ALL SHRUB ZONES, SPRAY ZONES AND GEAR DRIVEN ZONES SHALL BE PLACED ON SEPARATE ZONES. DO NOT EXCEED A MAXIMUM OF 5 FPS IN ALL MAINLINE AND LATERAL LINES. 12. COORDINATE ALL DRAINAGE AREAS AND UTILITIES WITH TREE LOCATIONS AND ADJUST PER FIELD CONDITIONS. 13. ALL EXISTING TREES SHOWN TO REMAIN SHALL BE RETAINED AND PROTECTED THROUGH OUT CONSTRUCTION. 14. NO TREES SHALL BE PLANTED WITHIN THE 10 FOOT CLEAR ZONE OF ALL ACHD STORM DRAIN PIPE, STRUCTURES, OR FACILITIES. 15. STORM PONDS MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. 16. ALL TREES TO BE LOCATED A MINIMUM OF 5 FEET OR GREATER FROM THE BACK OF ANY SIDEWALK.. 17. TRIM ALL TREES WITHIN VISION TRIANGLES TO 8' ABOVE FINISH GRADE TO MEET ACHD STANDARDS. LANDSCAPE NOTES SHRUB PLANTING NOT TO SCALE 1. WATER SHRUB TWICE WITHIN FIRST 24 HOURS. 2. APPLY SPECIFIED PRE-EMERGENT PER MANUFACTURER'S RECOMMENDATIONS TO ALL GROUNDCOVER BEDS. KEEP GROUND LINE SAME AS NURSERY LINE REMOVE ANY PLASTIC, BURLAP, NAILS, OR OTHER MATERIALS FROM THE ROOTBALL WHICH MAY LIMIT ROOT GROWTH CONSTRUCT 2" EARTH BERM TO FORM A WATER RETENTION BASIN, FILL BERM WITH MULCH, AS SPECIFIED MULCH, PER PLANS, 3" DEPTH OVER ENTIRE BED. DO NOT COVER CROWNS OF PLANTS PROVIDE DEWITT PRO 5 WEED BARRIER FABRIC OR APPROVED EQUAL PROVIDE COMMERCIAL FERTILIZER TABLETS AND BIOSTIMULANT, AS SPECIFIED, FOR EACH SHRUB BACKFILL WITH APPROVED TOPSOIL AND SOIL AMENDMENTS, AS SPECIFIED. BACKFILL IN 6" LIFTS, WATER EACH LAYER, DO NOT TAMP OR OVER COMPACT. CONSTRUCT 6" MOUND OF TOPSOIL 6" 6" WIDTH OF ROOTBALL 6" 1 'B' 'A' 'A' 'A' 'A' PERENNIAL & GROUNDCOVER PLANTING NOT TO SCALE 1. ALL GROUNDCOVER PLANTS TO BE PLANTED ON CENTER AND IN A TRIANGULAR PATTERN. 2. APPLY SPECIFIED PRE-EMERGENT PER MANUFACTURER'S RECOMMENDATIONS TO ALL GROUNDCOVER BEDS. FINISH GRADE PER PLANS EDGING, PER PLANS AND DETAILS GROUNDCOVER PLANTING PER PLANTING PLAN MULCH, PER PLANS, 3" DEPTH OVER ENTIRE BED. DO NOT COVER CROWNS OF PLANTS SPLIT ALL ROOT BOUND ROOTS WITH 3 EQUAL SPACED VERTICAL CUTS. TILL SOIL TO A DEPTH OF 12", BACKFILL WITH APPROVED TOPSOIL AND SOIL AMENDMENTS, AS SPECIFIED. DEWITT PRO 5 WEED BARRIER FABRIC OR APPROVED EQUAL SUBGRADE A = LENGTH, AS SPECIFIED OR PER PLANT SCHEDULE B = 85% OF 'A' 12" 3" 2 6" 1 1 2" 2" HIGHEST ROOT SHALL BE 2" MAXIMUM BELOW SOIL LINE. UTILIZE SOIL/ROOT PROBE AROUND TRUNK (APPROX 1"-2" AWAY FROM TRUNK) TO LOCATE HIGHEST ROOTS. SOIL LINE ROOT FLARE/COLLAR (SWELLING AT SOIL LINE WHERE STEM TISSUE TRANSITIONS INTO ROOT TISSUE) TO BE AT SOIL LINE. ROOT PROBE WHEN PRESENT: BUD POINT (A MINOR CROOK IN THE TRUNK JUST ABOVE THE SOIL LINE) TO BE APPROXIMATELY 1 1 2" ABOVE THE SOIL LINE 1. THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR LENGTH OF WARRANTY PERIOD OR 1 YEAR AFTER SUBSTANTIAL COMPLETION WHICHEVER IS GREATER. ALL STAKING SHALL BE REMOVED AT THE END OF THE WARRANTY PERIOD. 2. IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING. 3. LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TO INSTALLATION OF PLANT MATERIAL. 4. WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR FIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE. 5. WATER TREE TWICE WITHIN THE FIRST 24 HOURS. 6. IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. 7. FOR TREES LOCATED WITHIN ROADSIDE PLANTERS LESS THAN 8'-0" IN WIDTH, PROVIDE TREE ROOT BARRIER (DEEPROOT #24-2 OR APPROVED EQUAL). LOCATE ROOT BARRIER AT BACK OF CURB AND EDGE OF SIDEWALK. EXTEND ROOT BARRIER TO 80% OF MATURE TREE CANOPY. ALL TREE INSTALLATIONS SHALL CONFORM TO ALL AGENCY APPROVAL REQUIREMENTS, CONTRACTOR SHALL VERIFY PRIOR TO ANY INSTALLATIONS. REMOVE DEAD/DAMAGED BRANCHES AND PRUNE TO INTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS; IMPROPERLY PRUNED TREES (AS DETERMINED BY THE LANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED. DO NOT REMOVE MAIN LEADER!! RUBBER CINCH TIE 2"x 2" WOOD STAKE (LENGTH AS REQUIRED)-DO NOT PENETRATE ROOTBALL. SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND. REMOVE TREE WRAP TRUNK PROTECTION, AFTER INSTALLATION CONSTRUCT 2" EARTH BERM AT EDGE OF ROOTBALL, FILL TREE RING W/ MULCH, AS SPECIFIED. 3" THICK MULCH LAYER, KEEP MULCH 3" AWAY FROM TRUNK. REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP 2 3 OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTIC FROM ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TO WRAP THE ROOTBALL, IT SHALL BE COMPLETELY REMOVED. ONLY BIODEGRADABLE BURLAP SHALL BE LEFT ON THE BOTTOM OF THE ROOTBALL. FINISH GRADE PREVAILING WIND DIRECTION DECIDUOUS TREE PLANTING NOT TO SCALE 5' MIN. CLEAR AS SPECIFIED TO BASE OF CROWN 5' MIN. DIA. TREE RING WIDTH OF BALL WIDTH OF BALL WIDTH OF BALL WIDTH OF BALL WIDTH OF BALL COMMERCIAL SLOW RELEASE FERTILIZER TABLETS SIDES OF HOLE ROUGH & UNEVEN BACKFILL WITH APPROVED TOPSOIL AND SOIL AMENDMENTS AS SPECIFIED. BACKFILL IN 6" LIFTS, WATER EACH LAYER, TAMP LIGHTLY AS REQUIRED, BACKFILL SOIL EVEN W/ TOP OF ROOTBALL, DO NOT OVER COMPACT!! SET ROOTBALL ON NATIVE, UNDISTURBED SOIL 4 IRRIGATION NOTES: APPROVED TOPSOIL AND SOIL AMENDMENTS AS SPECIFIED 3" DEPTH OF MULCH AT PLANTER BEDS CUT EDGE FINISH GRADE, PER PLANS (TYPICAL AT TREES IN TURF AREAS) PLANTER BED CUT EDGE 3 NOT TO SCALE 2' 3" 1' 2'-6" R5" 3' 7 16"Ø HOLE FOR 3 8" REBAR (BY INSTALLER) 2" SCH. 40 GALVANIZED STEEL PIPE (2 3 8" O.D.) POWDER COAT, COLOR PER ARCHITECT BIKE RACK Scale: 3/4"= 1'-0" 2'-6" 5 TREE PROTECTION NOTES: 1. PROTECT THE CRITICAL ROOT ZONE (THE AREA DIRECTLY BELOW THE DRIPLINE OF THE TREE) OF THE TREES TO REMAIN ON SITE BY: a. CONSTRUCTING A TEMPORARY CHAINLINK FENCE AROUND THE CRITICAL ROOT ZONE OF THE TREE TO BE PROTECTED PRIOR TO DEMOLITION, CONSTRUCTION, OR ANY SITE WORK. b. NOT ALLOWING COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING DEMOLITION. c. NOT ALLOWING CONCRETE TRUCKS TO RINSE WITHIN THE PROTECTION AREA, OR ANYWHERE NEAR EXISTING TREE ROOTS OR IN PLANNED PLANTING BEDS AREAS. SEE EROSION AND SEDIMENT CONTROL PLAN FOR APPROVED CONCRETE WASHOUT AREAS. d. NOT STOCKPILING MATERIALS, DEBRIS, OR DIRT WITHIN THE TREE PROTECTION AREA. e. WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF NOT LESS THAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK. f. NOT TRENCHING, EXCAVATING, FILLING, OR OTHERWISE DISTURBING THE SOIL WITHIN THE CRITICAL ROOT ZONE. g. ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE ROOTS. 2. PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED BY: a. OPERATING EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR BRANCHES. b. HAVING TREES PRUNED BY A LICENSED ARBORIST. 3. ALL TREES THAT ARE DAMAGED, DESTROYED OR REMOVED DURING CONSTRUCTION SHALL BE MITIGATED USING THE MITIGATION STANDARDS AS SET FORTH IN THE CURRENT CITY CODE. TREE PROTECTION DETAIL NOT TO SCALE OUTLINE OF TREE CROWN (EDGE OF DRIPLINE) CORRESPONDING WITH ROOT SPREAD. FENCE SHALL BE PLACED AT EDGE OF TREE CROWN (MINIMUM DISTANCE). EXISTING GRADE NOTE: MAINTAIN PROTECTION UNTIL CONSTRUCTION ACTIVITIES ARE COMPLETED. IF LOWER LIMBS INTERFERE WITH WORK, TIE UP WITH HEAVY JUTE CORD. ADJUST DIAMETER OF PROTECTIVE FENCE TO PREVENT ANTICIPATED DAMAGE BY EQUIPMENT. TREE TRUNK CROWN OF TREE. OUTLINE OF TREE CROWN (EDGE OF DRIPLINE) CORRESPONDING WITH ROOT SPREAD. FENCE SHALL BE PLACED AT EDGE OF TREE CROWN (MINIMUM DISTANCE). SECTION PLAN VIEW TREE CROWN FENCE LINE 6 06/15/22 A-2022-0090 FRONT: 0' REAR: 0' SIDE: 0' STREET: 25' STREET LANDSCAPE BUFFER: 10' (LOCAL) PARKING REQ. : ONE (1) SPACE FOR EVERY TWO THOUSAND (500) SQUARE FEET OF GROSS FLOOR AREA = 148 STANDARD STALLS @ 73,778 S.F.REQUIRED. 172 STANDARD AND 6 ADA STALLS PROVIDED. BICYCLE PARKING: 1 / 25 VEHICLE STALLS = 7 REQUIRED SPACES. TWO (5 STALL) RACKS PROVIDED LANDSCAPE REQUIREMENTS: SITE DATA: TREE MITIGATION NOTES: 1. ALL EXISTING TREES ON SITE TO REMAIN. 2. SEE TREE PROTECTION NOTES AND DETAIL 6/L1.1 FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 3. THE LANDSCAPE ARCHITECT WILL MEET WITH THE CITY ARBORIST TO ESTABLISH MITIGATION REQUIREMENTS BEFORE REMOVAL OF ANY EXISTING TREES. 10 JB PLANT SCHEDULE Betula nigra River Birch Gleditsia triacanthos inermis 'Skyline' Skyline Honeylocust Prunus cerasifera ‘Krauter Vesuvius’ Krauter Vesuvius Plum Quercus robur x alba Streetspire Oak Tilia tomentosa ‘Sterling’ Sterling Linden 2" B&B 2" B&B 2" B&B 2" B&B 2" B&B 35' hgt. 25' w 45' hgt. 30' w 20' hgt. 15' w 35' hgt. 15' w 45' hgt. 35' w CLASS II CLASS II CLASS I CLASS II CLASS II Euonymous alatus 'Compactus' Dwarf Burning Bush Cornus alba 'Bailhalo' Ivory Halo Dogwood Cotoneaster horizontalis Perpusillus' Prostrate Rock Cotoneaster Juniperus scopulorum 'Medora' Medora Juniper Potentilla fruticosa 'Gold Star' Gold Star Potentilla Rosa x 'Flower Carpet' Merlot Flower Carpet Rose Spiraea japonica 'Goldmound' Goldmound Spirea Perovskia atriplicifolia 'Blue Jean Baby' Blue Jean Baby Russian Sage Calamagrostis x. acutiflora 'Overdam' Dwarf Feather Grass Hemerocallis x 'Stella De Oro' Stella De Oro Daylilly Lavandula angustifolia 'Dilly Dilly' Dilly Dilly Lavender Pennisetum alopecuroides 'Little Bunny' Little Bunny Dwarf Fountain Grass 2 Gal. 5 Gal. 2 Gal. 5 Gal. 2 Gal. 2 Gal. 2 Gal. 2 Gal. 1 Gal. 1 Gal. 1 Gal. 1 Gal. 4' hgt. x 4' wide 6' hgt. x 6' wide 12" hgt. x 6' wide 10' hgt. x 4' wide 3' hgt. x 3' wide 3' hgt. x 4' wide 3' hgt. 3' wide 3 hgt. x 3' wide 3' hgt. x 2' wide 18" hgt. x 2' wide 12" hgt. x 18" wide 2' hgt. x 3' wide BOTANICAL NAME COMMON NAME BN GT PC QR TT KEY DECIDUOUS TREES . PLANTING MATURE SIZE CLASS SIZE SHRUBS . GROUND COVERS/ GRASSES/ PERENNIALS . (*NOTE: ALL TREES TO BE GRADE #1, SHOWN AT 80% MATURITY) QUANTITY PLANT IDENTIFICATION KEY PLANTS TO BE INSTALLED EXISTING TREES AND SHRUBS TO REMAIN PROPERTY LINE (VERIFY) CUT EDGE, SEE DETAIL 3/L1.1 RTF TURF TYPE TALL FESCUE SOD OVER APPROVED TOPSOIL AS SPECIFIED PROPOSED BUILDING LANDSCAPE LEGEND TRASH ENCLOSURE PER ARCHITECTURAL. EXISTING CANAL AND ACCESS ROAD TO REMAIN. EXISTING TURF TO REMAIN. CUT IN SOD TO PATCH BACK ANY DISTURBED AREAS AND MEET EXISTING. BICYCLE PARKING RACK, SEE DETAIL 5/L1.1. EXISTING SHELTER TO BE REMOVED. EXISTING HORSESHOE PITS TO REMAIN. PROPOSED CONCRETE PATHWAY CONNECTION TO EXISTING SITE AMENITIES. CALLOUT LEGEND 1 2 3 4 5 6 7 SEE DETAIL 4/L1.1 SEE DETAIL 1/L1.1 SEE DETAIL 2/L1.1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES Call before you dig. Know what's below. R South Landscape Architecture P.C. Dba South Beck & Baird Landscape Architecture P.C. 2002 S. Vista Ave Boise, ID 83705 208.342.2999 Office info@sbbgo.com www.sbbgo.com All rights reserved. Reproduction or use in any form or by any means without written permission of South Landscape Architecture P.C. Dba South Beck & Baird Landscape Architecture P.C. is unlawful and subject to criminal prosecution. No. Date Description THE PROFESSIONAL SERVICES OF THE DESIGN PROFESSIONAL ARE UNDERTAKEN FOR AND ARE PERFORMED IN THE INTEREST OF "THE CLIENT" NO CONTRACTUAL OBLIGATION IS ASSUMED BY THE DESIGN PROFESSIONAL FOR THE BENEFIT OF ANY OTHER PERSON INVOLVED IN THE PROJECT. Design Review F O S C A P E A R C H I T E C T D N A L D E S N E C I L E T A T S I D A H O D . H O J O T E R R N S LA - 16827 L1.0 SEE SHEET L1.1 FOR LANDSCAPE NOTES AND DETAILS. 06/15/22 A-2022-0090