Loading...
HomeMy WebLinkAboutSite Plan V1APPROVED OW14,22 SEE SHEET C3.0 FUTURE I or(79.52CL) SETTLERS PARK + TOWNHOMES AI M SDI �(79.40SC) � U O 3+01 8313+83.64 .�� 00 (79r.13SC)3+14.62 .54 16.50'R 79.02C 79.33NC30 787.1+85.1165'R 78.87LIP o a5TVC 81d 7787NR20`(79.19CL Id +) 8.59LIP 8 m 4 o 0 .,.. 78.56LIP 78.89LIP 3 Xo o, pB 3+74.11 3+01.5� 78.665C9 6 78.68LIP 0.52% 09935CL 79.35+CL 709156CL 77.50LIP Z o "c, 3+90.44 77.79 CL 78.18 CL o o „� W. WIND DRIFT T. 78.77LIP 77.70 CL 00 2 7 3+00 2+00 1+00 I� 0+ 0 76.52NC 4+00 77.44LIP r77.54LIP 77.74LIP 7 78.70LIP 78.73LIP 0+00 O O 1 `� i 77.58LIP 77.84LIP r78.5DLIP 0.06% 7f 8.78LIP 79.04 CL 10 + + 78.66LIP Qy J (78.98CL) O O ` ~ 1.87%%0� 2.06% 4+14 54 6 + 76.04NC .o y - 77.70LIP� - 7854LIP - 6 _ 77684LI 77.57 CL - - - o - 76.04LIP "" -- of � g \ R20.00' .'76.10NC 1.28% 5+00.65 0- „� �78.81LIP 76.03LIP o0 1.29% 76.22LIP 77.10 CL= p ,t, 77.62LIP Z ,,1 - 111%--i2k00 �i � .NZZ o 78.SSLIF Z o Z Z o V 6 5 .- ` .o 78.07NC 79.02NC 0 A 78.35TVC °' `" 79.32NC s� 5 55 5+75.52 5+41.08 � 6,� Q, + N 6 �°��� 76.14 CL 76.58 CL �.`so. M 3+74.11 13.50'L ^ M+, ^ ± �o o 0 1.02% 76.24LIPoo. r 77 �(78.85CL) 76.26NC 76.11 LIP __ 2 V cO a>g o s>> ST. LUKES +4a% 7s.8auP 7s.12DP FUTURE SITE 76.33N2576 CJ 76.75NC] + SEE SHEET C3.0 I III WIND DRIFT ST PROFILE 5+89 5+00 4+00 3+00 2+00 1+00 0+00 2580 a 2575 2570 2565 5+89 + + FINISHED GRADE +� Fy9elFAyP�ST ST9 9" O x 0+17.63 Jx20 0012 GB 2578.81s� O 0 +� o " o o n _ _ + N _ --O:r2%- - - - - - =65L -0.52% 1.21% 1.90 0 0 00% 67% v'm - N � -0.55% -0.54% -0.54% -0.54% - ----- - _ - ----------- \ -1.28% `EXISTING GRADE -8%----------- ___--------------- 2 PIRR WITH l 4" -C-900 SLEEVE VERTICALS ALE 0 3' 6' SCALE 1" _ 5+00 4+00 3+00 2+00 1+00 �2580 2575 2570 2565 0+00 N 0 30' 60' W E SCALE 1" = 30' S KEYNOTES: 0 INSTALL NEW SDCB #2 - PER ISPWC AND ACHD SUPPLEMENTAL DRAWING SD-604A. 2576.04' NC. 12" INVERT OUT = 2572.85'. PIPE. (Q10D=1.92CFS) 0 INSTALL t5.51F 12" SDR-35 O 0.22%. INVERT MANHOLE SDCB #2 2572.85'. INVERT AT SAND AND GREASE TRAP #5 2572.83'. INSTALL 3-1500 GAL SAND AND GREASE TRAPS #1 FOR SETTLERS PARK DR., FUTURE TOWNHOMES DRIVELANES, PARKING, 3 SIDEWALKS, AND � OF BUILDING ROOF AREAS. SEE DETAILS ON SHEET C3.2. INSTALL ±19LF 12" SDR-35 ® 0.22%. STUBBED INVERT = 0 2572.88'. INVERT AT SAND AND GREASE TRAP #5 2572.83'. O INSTALL PRIVATE STORM DRAIN POND #1. SEE DETAILS ON SHEET C3.2. OINSTALL 4FT VALLEY GUTTER PER ISPWC STANDARD DRAWING SD-708. O7 INSTALL NEW STREET LIGHT INSTALL MIDBLOCK PEDESTRIAN RAMPS PER ISPWC SUPPLEMENTAL O DRAWING SD-712F. 0 INSTALL STOP SIGN PER MUTCD STANDARDS. 0 INSTALL MONITORING WELL PER ISPWC SUPPLEMENTAL DRAWING SD-627. 1 1 INSTALL STREET NAME SIGN PER MUTCD STANDARDS. NOTE: 1. ALL PEDESTRIAN FACILITIES SHALL HAVE A MAXIMUM CROSS SLOPE OF LESS THAN 2% WITHOUT DEVIATION. ALL PEDESTRIAN RAMPS SHALL HAVE TRUNCATED DOMES PER ACHD SUPPLEMENTAL STANDARD DRAWING SD-712. DOMES SHALL BE RIGID INSERTS WET -SET INTO THE CONCRETE (CONCRETE STAMP AND ADHESIVE MATS NOT ALLOWED) AND SHALL BE COLORED 'TRAFFIC YELLOW'. ALL PEDESTRIAN RAMPS TO BE PER ISPWC STANDARD DRAWING SD-712A, UNLESS OTHERWISE CALLED OUT. 2. ANY ABANDONED BUILDINGS, TEST PITS, TEMPORARY STORM DRAIN PONDS AND WATERWAYS LOCATED WITHIN CURRENT OR FUTURE RIGHT-OF-WAY SHALL BE REEXCAVATED TO NATIVE SOIL AND BACKFILLED WITH STRUCTURAL FILL PER ISPWC SPECIFICATIONS. PROVIDE SOIL DATA TO VERIFY NATIVE MATERIAL MEETS THE REQUIREMENTS FOR ENGINEERED FILL PER ISPWC SPECIFICATION AND A COPY OF THE COMPACTION TESTS. 3. COLLECTOR ROADWAYS SHALL BE SP-3, 0.50 INCH (J") MIX, PG-64-28 THREE INCHES (Y) THICK, AS A MINIMUM WITH 4" OF y" BASE AND 20" OF 6" MINUS PIT RUN. 4. PRIOR TO PLACEMENT OF ANY PAVEMENT MARKINGS CONTACT ACHD INSPECTION FOR VERIFICATION OF COMPLIANCE WITH POLICY AND EXISTING PAVEMENT MARKINGS. FOR SUBDIVISION SIGN INSTALLATION; OUTSIDE INSTALLERS MUST BE BONDED WITH ACHD AND OBTAIN A NO -CHARGE RIGHT OF WAY PERMIT. 5. ALL INTERIOR ROAD RADII ALONG SETTLERS PARK DRIVE ARE 15' UNLESS OTHERWISE CALLED OUT. Lo 00 Lo r i N co i O O 00 z 0 Q � w W w `z V J U z V Lu O LL LLI m O 0 O m Q Q EL � W LJ� Lw1 UT N m � N N O LLj 7N W � U Nol Z w-� c) aJN z��W cD W W z Y�o� m � mo U) Z w z Y Q 0 0 0 O G15TE Gl/ O 94122 LL s� C'T9 TE OF \D"Q' OS.KIN�� Z SHEET C3.1 APPROVED OW14,22 llmm � I a i IP 1 � N 68.99' + +- -7 ,-- - ---r- ,- -+ + + + + + + + + + + + 3 + + + + + + + + + + + + + 76.( + + + + + + + + + + + + + s N + + + + + + + + + + + + + + + + + 71.55BOT L + + + + + + 4 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + �+ + + + + + + + + + + + + + + + + + + + o + + --- + + + + + + + + + + + + + + + + + + 52.37' I I I I 71.55BOT - - - - - - I III I 71.55BOT- - - - - - - � 52.92' N \ W E S 0 10' 20' SCALE 1" = 10' m PIR - 75.15TOP T aid Hid 75.75TOP I 76.53�1 1 1 PRIVATE STORM DRAIN POND 1 SECTION VIEW - NTS - INSTALL 3- 1000 GAL S/G TRAP INSTALL t95SF OF 6" COBBLE FOR O1 #1. SEE DETAIL THIS SHEET. 3 O INFILTRATION. O12" INSTALL f15LF 18" SDR-35 @ 2.87% INV AT S/G TRAP #1 2571.98'. O INSTALL 1,200 SF OF SANDY LOAM MATERIAL FOR THE SAND WINDOW 12" INV AT POND 2571.55'. FOR VEGETATION. 2574.65' HW DESIGN VOLUME 2576.00' FG VREQDiRED-11,689 FT3 VPRQMDED=11,860 FT3 2571.55' FG �� i _� 2571.55' FG SAND WINDOW TO BE EXCAVATED INTO FREE DRAINING MATERIALS. IF OVER -EXCAVATION IS REQUIRED TO GET TO FREE o DRAINING MATERIALS, CLEAN PITRUN CAN BE USED AS BACKRLL. BOTTOM OF `? SAND FILTER SAND AREA = 1,200 SF. 2568.55' USE SANDY LOAM MATERIAL 2568.51' 7 THAT WILL ALLOW FOR A PERCOLATION GW a RATE OF 2.4"/HR AND FOR VEGETATION STORM DRAIN POND NOTE: 2575.15' FG CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY IF GROUNDWATER IS ENCOUNTERED WITHIN 3 FEET PER THE GROUNDWATER MONITORING OF THE BOTTOM DESIGN ELEVATION FOR ANY INFILTRATION FACILITY OR IF GROUNDWATER IS HIGHER THAN REPORT BY NATURAL RESOURCE THE EXPECTED ELEVATION. SOLUTIONS, LLC DATED OCTOBER 13, 2021. GROUNDWATER IS EXPECTED IF ROCK IS ENCOUNTERED, THE CONTRACTOR SHALL HAVE A PERCOLATION TEST PERFORMED BY THE TO BE LOCATED AT 6.50' BELOW SOILS ENGINEER AFTER THE POND IS FULLY EXCAVATED A PERCOLATION RATE OF 2 4"/ HR WILL BE EXISTING GROUND. USED FOR DESIGN BASED ON THE SOILS REPORT DONE BY ATLAS DATED MARCH 9, 2021. IF THE PERCOLATION RATE IS LESS THAN SPECIFIED BY THE SOILS REPORT AND ENGINEER, CONTRACTOR MAY NEED TO BLAST OR BORE TO CREATE CONDUIT FOR DRAINAGE TO OCCUR OR REDESIGN THE SYSTEM TO ACHIEVE THE REQUIRED INFILTRATION. PRIVATE STORM DRAIN POND 1 SECTION -NTS- U W 2 W 4- 0 2 O 0 0 0 0 h� 6S J� 4 5°R�3��pUs III III III III RAM S/�3S �N LOW PROFILE RING HS 25 RATED STRUCTURE LID TO BE FLUSH WITH AND COVER TYP. FINISHED SURFACE FG ±2576.00' 2572.73' TOP OF CONC. 20" 2572.83' dNV IN FROMB#212"OUT TOPOND #1INV. 2571.98' "MIN. 2570.55' 2570.55' 18" CONNECTING PIPE CONNECTING PIPE 3-1000 GAL. SAND/GREASE TRAP 1 - NTS - PER BMP-01 R.O.W 47'-0" 7'-0" 33'-0" 16'-6" 16'-6" I~ 14'-6" 14'-6" 2.00% SLOPE I 2.00% SLOPE I 'I [MIN 1' LEVEL LANDING BEHIND SIDEWALK (TYP) OKX OUS c� OPE 8' WIDE PLANTER STRIP (TYP) J J / EXTEND BASE MATERIAL 14" OF 6" MINUS PIT RUN 5' WIDE CONCRETE SIDEWALK PER ISPWC 6" BEHIND CURB (TYP) 3" OF ASPHALT PAVEMENT STANDARD VERTICAL CURB & GUTTER PER ISPWC SUPPLEMENTAL DRAWING SD-701 SUPPLEMENTAL DRAWING SD-709 (TYP) SP-3 0.50" MAX PG58-28 4" OF %4" MINUS CRUSHED GRAVEL PRIVATE ROAD - 4T ROW SECTION WITH 33' STREET SECTION -NTS - 00 L0 1 N 1 0 MO W 1 z r O I— u/ CL W Lu z_ J J J Q U C� `V V Lu O LL Lu m 0 N m � N N O Lu N Nol Z w-� aJN W W z � Yo m o V� m m m o � VJ'�//�� Z w z Y o Qw w.. E>' 0 0 0 O �S\oNAO F1 GIST G O 9412 A LL 6/08/22 C'STq I& of IOP��P yq0 S. I, O Z SHEET C3.2