HomeMy WebLinkAbout11_6PLEX Single Story_Floor Plan V129' El(IDIANg-
APPROVED
ChM. MlM2
FU NUMBFA:^-aa -
T
T
T
T
T
06 A-3.0 T
T
T
10
- - - _..
1 3/16" = 1'-0"
2X6 WOOD FRAMING, CAVITY
FILLED W/ R-21 BATT INSULATION
"HARDI" SIDING (OR CEMENTITIOUS
EQ.) o/ TYVEK (OR OTHER APPROVED
EQ.) o/ WALL SHEATHING - REFER TO
ELEVATIONS FOR EXTERIOR FINISH
TYPE
5/8" GYP @ INTERIOR LOCATIONS
(TYPE "X" TYP., NOT REQUIRED AT
NON RATED LOCATIONS)
W1 STANDARD EXTERIOR WALL
2X4 WOOD FRAMING ON 2X6
PLATE
(2) LAYERS 5/8" GYP. B.D EA. SIDE
PRIME, PAINT & FINISH, EACH SIDE.
ACOUSTIC BATT
INSULATION
W5 2X6 SEPARATION WALL
NOTE: FIRE RATED WALL PER GA FILE NO WP 3910.
ALL PENETRATIONS MUST BE FIRE CAULKED OR
OTHERWISE PROTECTED
2X4 WOOD FRAMING
5/8.'GYP. B.D EA. SIDE PRIME,
PAINT & FINISH, EACH SIDE.
ACOUSTIC BATT
INSULATION
W2 STANDARD 2X4 WALL
2X WOOD FRAMING -SEE PLAN
(2) LAYERS 5/8" GYP. B.D EA. SIDE
OF STUDS
ACOUSTIC BATT
INSULATION
W6 STANDARD SEPARATION WALL -
EXTERIOR
NOTE: FIRE RATED WALL PER GA FILE NO WP 3820.
ALL PENETRATIONS MUST BE FIRE CAULKED OR
OTHERWISE PROTECTED
2X6 WOOD FRAMING
5/8" GYP. B.D EA. SIDE PRIME,
PAINT & FINISH, EACH SIDE.
ACOUSTIC BATT
INSULATION
W3 STANDARD 2X6 WALL
2X4 OR 2X6 WOOD
FRAMING- SEE PLAN
(2) LAYERS 518" TYPE "X" GYP.
B.D EA. SIDE OF STUDS PRIME,
PAINT & FINISH INT. SIDE.
ACOUSTIC BATT INSULATION
"HARDI" SIDING (OR CEMENTITIOUS
EQ.) o/ TYVEK (OR OTHER APPROVED
EQ.) o/ DENSGLASS - REFER TO
ELEVATIONS FOR EXTERIOR FINISH
TYPE
W7 STANDARD SEPARATION WALL -
EXTERIOR 1 SIDE
NOTE: FIRE RATED WALL PER GA FILE NO WP 3820.
ALL PENETRATIONS MUST BE FIRE CAULKED OR
OTHERWISE PROTECTED. REFER TO FLOOR PLANS
FOR LOCATIONS
2X4 WOOD FRAMING
(2) LAYERS TYPE "X" 5/8" GYP. B.D
EA. SIDE OF STUDS PRIME, PAINT
& FINISH INT. SIDE.
ACOUSTIC BATT
INSULATION
W4 STANDARD SEPARATION WALL
NOTE: FIRE RATED WALL PER CA FILE NO WP 3820.
ALL PENETRATIONS MUST BE FIRE CAULKED OR
OTHERWISE PROTECTED
2X6 WOOD FRAMING, CAVITY
FILLED W/ R-21 BATT INSULATION
"HARDI" SIDING (OR CEMENTITIOUS
EQ.) o/ TYVEK (OR OTHER APPROVED
EQ.) o/ min. 7/16" WALL SHEATHING -
REFER TO ELEVATIONS FOR
EXTERIOR FINISH TYPE
5/8" GYP @ INTERIOR LOCATIONS
(TYPE "X" TYP., NOT REQUIRED AT
NON RATED LOCATIONS)
W8 1-HR RATED EXTERIOR WALL
NOTE: FIRE RATED WALL PER UL U356 ALL
PENETRATIONS MUST BE FIRE CAULKED OR
OTHERWISE PROTECTED
GENERAL NOTES:
A. VERIFY ALL DIMENSIONS IN FIELD AND NOTIFY ARCHITECT OF DISCREPANCIES
PRIOR TO FABRICATION OR INSTALLATION
B. TYPICAL DIMENSION LOCATIONS ARE TO F.O. CONCRETE OR GRID LINES OR
LEFT/TOP SIDE OF F.O. STUD, U.N.O. (TO F.O. STRUCTURAL MEMBERS, NOT TO F.O.
FINISH MATERIALS
C. PROVIDE SOLID BLOCKING IN WALLS FOR ITEMS SUCH AS GRAB BARS, TOILET
PARTITIONS, PAPER DISPENSERS, WALL -HUNG TOILETS, AND ETC.
D. ALL STUD FRAMED INTERIOR PARTITIONS WALLS SHALL BE BRACED TO THE
UNDERSIDE OF DECKISTRUCTURE ABOVE
E. CONTRACTORS SHALL ADHERE TO ALL CODES, RULES AND REGULATIONS FOR IBC
AND SPECIFIC TRADE CODES
F. DO NOT SCALE DRAWINGS
G. LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS
U.N.O.
H. ALL EXPOSED GWB EDGES TO HAVE METAL EDGE TRIM, TYP.
I. LIGHTER LINES TYPICALLY INDICATE OWNER SUPPLIED ITEMS U.N.O.
J. ALL NOTES AND COMPONENTS TO BE CONSIDERED " OR EQUIVALENT" AS LONG AS
INTENT/QUALITY OF THE DESIGN IS MAINTAINED.
K. ANY NOTES STATED HEREIN SHALL BE SUPERCEDED BY NOTES PROVIDED IN
STRUCTURAL, MEP DRAWINGS (WHICH WILL TAKE HIGHER PRIORITY).
L. GRADES AT ENTRY DOORS TO BE NO MORE THAN 1.5% IN ALL DIRECTIONS FOR A
MINIMUM DISTANCE OF 5' - 0" PERPENDICULAR TO DOORS
FOUNDATIONS
A. PLACE ALL REINFORCING AS PER A.C.I. CODES AND STANDARDS
B. WATERPROOF BASEMENT/STEM WALLS BEFORE BACKFILLING.
C. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE
TREATED, REDWOOD OR PROTECTED WITH 55# FELT.
D. MUDSILLS TO BE 2 x PRESSURE TREATED WOOD OR REDWOOD.
E. 2" RIGID INSULATION TO BE ATTACHED TO FOUNDATION
PERIMETER WALLS.
FRAMING
A. UNLESS OTHERWISE NOTED ON PLANS, ALL EXTERIOR WINDOW AND
DOOR HEADERS ARE TO BE SIZED PER ENGINEER.
B. SOIL BEARING PRESSURE IS ASSUMED TO BE 1500 P.S.F. IF THIS VARIES,
CONTACT ARCHITECT PRIOR TO CONSTRUCTION.
C. NAILING SCHEDULE AS PER TABLE 25-0 I.B.C. TYPICAL PLYWOOD
NAILING WITH 8D NAILS @ 6" O.C. AT EDGES AND 12" O.C. ON INTERIOR.
D. WOOD FRAMING MEMBER GRADES ARE AS FOLLOWS UNLESS OTHERWISE NOTED ON THE PLANS:
POSTS, BEAMS, HEADERS, JOISTS & RAFTERS: NO. 2 & BETTER KD DOUGLAS FIR -LARCH
PLATES, BLOCKING & BRIDGING, ETC.: NO.3 & BETTER KD DOUGLAS FIR -LARCH
STUDS: STUD GRADE KD DOUGLAS FIR -LARCH
POST & BEAM DECKING: UTILITY GRADE DOUGLAS FIR
PLY SHEATHING: CD DOUGLAS FIR PLY 7/16"
INSULATION
A. ALL EXPOSED INSULATION TO HAVE AFLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE
DENSITY OF LESS THAN 450
KEYNOTES - FLOOR PLAN
#
NOTE
2.1
MULTIPLE WINDOWS FRAMED VERTICALLY- REFER TO
ELEVATIONS AND WINDOW TYPES.
Z+)
ARCHITECTURE
DESIGNS PLUS, P.A.
PROFESSIONAL SEAL
LICENSED
,ARCHTI'ECT
.AR-818618
c�rvry anu�rz
co
SiA]E OF IDAHO
o
M h
M �
c
nn d
Wr^4 �
44 �y
1�
^144
u
CI W qco
00
n �
W Qq
�o
W
I..L
I
Z
Q
O J J
a
D < �W
LL c 0
O J Q
0 O — LL
Z
> 0 W
w W Q J —
Z w >
WQ O'w
0 U
a
JOB NO: 20185
DATE:
DRAWN BY: BPB
SHEET NUMBER:
A-2.0
PLOT DATE:
2/25/2022 4:39:31 PM
w
a
0
rn
z
O
to
w
a
O
z