Loading...
HomeMy WebLinkAboutLandscape Plan V1 (2)1^ ° 0 000 @i 3250 S EAGLE RD ( BURLEY WEST INVESTMENTS APN- R7877770020 KAN CD U, ° W SD SO SO SO SO S SDCD SD G G G G G—G —G G G G G G G ( G G G G GG G G I I I I CD a_ — — — — -- -- — — — — — — — — — ---A CD __J I PLANT SCHEDULE DECIDUOUS TREES BOTANICAL / COMMON NAME SIZE CONTAINER CITY GI GLEDITSIA TRIACANTHOS INERMIS ' SKYCOLE' TM / SKYLINE THORNLESS HONEY LOCUST 2" CAL. B&B 4 TR TILIA AMERICANA 'REDMOND' / REDMOND AMERICAN LINDEN 2" CAL. B&B 3 ZV ZELKOVA SERRATA 'VILLAGE GREEN' / SAWLEAF ZELKOVA 2" CAL. B&B 1 FLOWERING TREES BOTANICAL / COMMON NAME SIZE CONTAINER I CITY MP MALLS X ' PRAIRIFIRE' / PRAIRIFIRE CRAB APPLE 2" CAL. I B&B 13 SHRUBS BOTANICAL/ COMMON NAME SIZE CONTAINER OTY CK CALAMAGROSTIS X ACUTIFLORA ' KARL FOERSTER' / FEATHER REED GRASS 2 GAL 10 CR CORNUS SERICEA / RED TWIG DOGWOOD 5 GAL 3 JB2 JUNIPERUS SCOPULORUM 'BLUE ARROW / BLUE ARROW JUNIPER 5 GAL. 10 LA LAVANDULA ANGUSTIFOLIA / ENGLISH LAVENDER 2 GAL 5 PB PENNISETUM ALOPECUROIDES 'LITTLE BUNNY / LITTLE BUNNY FOUNTAIN GRASS 2 GAL 18 PS PINUS MUGO 'SLOWMOUND' / MUGO PINE 5 GAL 13 RF ROSA X ' NOARE' / FLOWER CARPET RED GROUNDCOVER ROSE 2 GAL 9 RG RHUS AROMATICA ' GRO-LOW' / GRO-LOW FRAGRANT SUMAC 2 GAL 3 SG SPIRAEA JAPONICA ' GOLDMOUND' / SPIREA 2 GAL 2 SL SPIRAEA X BUMALDA ' LIMEMOUND' TM / LIMEOUND SPIREA 2 GAL 10 I I I W W W W IN W _ W IN WIN I W W— CD • I i I PS (3 (5) LA II (1 3) PS PB (10 + + + + + �- cs + + + + {r + + U, + + + + + + + + + H�O — + I _ _ + + + +1 + + + \,01 - + + + + + + — Material Legend: SOD TURF 3" DEPTH, MINUS ANGULAR GRAVEL MULCH, COLOR:TAN EXISTING LANDSCAPE RETAIN AND PROTECT. Landscape Notes: A. CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPER EXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK. B. FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN. REMOVE RIDGES AND FILL DEPRESSIONS, AS REQUIRED TO MEET FINISH GRADES. PLACE 4" OF ROCK MULCH OVER SUBGRADE SOIL TO ACHIEVE FINISH GRADE. FINISH GRADE RELATED TO ADJACENT SITE ELEMENTS SHALL BE: B.A. 1-INCH BELOW TOP OF ADJACENT PAVEMENT, VALVE BOX, VAULT, ETC. B.B. 3-INCHES BELOW TOP OF CURB UNLESS NOTED OTHERWISE. C. ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 18" OF TOPSOIL, SOD AREAS A MINIMUM OF 12" OF TOPSOIL. SPREAD, COMPACT AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE. D. RE -USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OF SURFACE SOIL TO PRODUCE TOPSOIL MEETING REQUIREMENTS AND AMEND WHEN NECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHER FOREIGN MATERIAL AND A PH OF 5.5 TO 7.0. IF ON -SITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A) PROVIDE APPROVED IMPORTED TOPSOIL, OR B.) IMPROVE ON -SITE TOPSOIL WITH W _ W W W W - IN W W METHODS APPROVED BY LANDSCAPE ARCHITECT. SUPPLEMENT WITH IMPORTED TOPSOIL —� • WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS, PLANTS, SODS, STONES, `rs CK (5 CLAY LUMPS AND OTHER EXTRANEOUS MATERIALS HARMFUL TO PLANT GROWTH. GI (1 E. IF IMPORTED TOPSOIL FROM OFF -SITE SOURCES IS REQUIRED, PROVIDE NEW TOPSOIL THAT IS RG (3)� I FERTILE, FRIABLE, NATURAL LOAM, SURFACE SOIL, REASONABLY FREE OF SUBSOIL, CLAY _ l ' °01 CR( — - _ /�o\ + + + + + 0 I 3 I (L7 — — — — + + + + + + + + w MP (2 D ... + + + + + + I 1 ((�1�,� '""'P — SO SO + + + + + + > + + + + + + + + + I i* + + + + + + + + + + + + + + + + + + + + + + + + + w I I — PROPOSED BUILDING@} (6) RF j +: +: *+ + + + + + }r + + - - ° o . W W _W + V + �l + +++ ++ + q + + + N + C9 + + W + + + + + + ++ + ++ + ++ + ++ + ++ i , Landscape Plan Horizontal Scale: 1" = 10. + + + + + + + + + + + + +1 + +++�� +++++ +++++ ++++++++I +++++ + + + + + + + + + + W W W I + + + + + 1 ° W— + + + C + s° + + + + + + + 0 + + + + + +—T + + + H �0 + + + + + + + + + + + + + + + + + + + + + + [++++++4+1 + + 1 00 + + + + + + 0 + + + + + + + + + + + + + + + + [+++++ + + + +�+++++++ + + + + +++ +f++++ OI ++ + +++++++ +++ + + + + + + + + + + + + + + (} + +" @ +�+++ +++F+++++ + + + +1 + + + II + ++ ++ ++++0+++ 0 + + + + ++++ ++0+++ + + + + + + II + + + + + + + + + + II + + + + 1 o + + + + + + + +1 + + 1 +�+0++0000 + + � 0 + + + + + + + + + `�_0+ + +1 + + + 1 + +++++ ++++ C? W W N w w :1-5 (3) CK y� 0)ZV I . . E zy.......... :� ............ N**,*,*•*•*,*,*,*,*,*,*, ...... ........... .......... ...... .............. — — :f: : : : : : : : : O......... ............ o�.'.'.'.'.'.'.'.'.'.'.'. .,,........... , ...... .. ... �. .................. .... ......... . .. ....... . . r''''''''''':O ..... ......... ).*. , ... ...... .... ..... .... ....................... ...... . ... ............ (1) MP TR (3 I.'.'.'.'.'.'.'.'.'...') I* .a ...a Q.r.........r.r. a LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS, STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH. F. OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THAT FOUND AT PROJECT SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY, WELL -DRAINED SITES WHERE TOPSOIL OCCURS IN A DEPTH OF NOT LESS THAN 4 INCHES. - J G. ALL LANDSCAPE AREAS SHALL BE WEED FREE AT THE TIME OF LANDSCAPE INSTALLATION.REMOVE ALL ROOTS, WEEDS, ROCKS AND FOREIGN MATERIAL ON THE SURFACE. H. NEW TREE PLANTING, SEE DETAIL 1/11.50. CONTRACTOR SHALL STAKE ALL TREES DEEMED NECESSARY, LE..... FROM BEING BLOWN OVER, PLANTED WITH LOOSE ROOT BALL, ETC. CONTRACTOR'S OPTION. I. NEW SHRUB PLANTING. SEE DETAIL 2/1-1.50. J. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION. K. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE o DATE OF SUBSTANTIAL COMPLETION. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAME SIZE AND SPECIES AT NO COST TO THE OWNER. o L. TREE PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR TREE PIT BACKFILL AT THE FOLLOWING RATES. BLEND AMENDMENTS THOROUGHLY WITH SOIL BACKFILL. TREE PITS SHALL BE 5k&xl.5' (37.5 CF/ 1.5 CY). L.A. APPLICATION RATES: L.A.A. HUMIC ACID: 25 LBS PER TREE PIT L.A.B. COMMERCIAL GRADE COMPOST -10 CUBIC FEET PER TREE PIT L.A.C. PLANTING TABLET FERTILIZER - 4 TABLETS PER TREE PIT L.A.D. CALCIFIED DIATOMACEOUS EARTH - 75 LBS PER TREE PIT M. SHRUB PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR SHRUB PIT BACKFILL AT THE FOLLOWING RATES. BLEND AMENDMENTS WITH THOROUGHLY WITH SOIL BACKFILL. SHRUB PITS SHALL BE 2.5'x2.5M' (6.25 CF/ 0.25 CY). M.A. APPLICATION RATES: M.A.A. HUMIC ACID: 2 LBS PER SHRUB PIT 2 M.A.B. COMMERCIAL GRADE COMPOST - 2 CUBIC FEET PER SHRUB PIT M.A.C. PLANTING TABLET FERTILIZER - 2 TABLETS PER SHRUB PIT M.A.D. CALCIFIED DIATOMACEOUS EARTH -15 LBS PER SHRUB PIT N. IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY OFF SITE. I 0. CONTRACTOR SHALL SUBMIT MATERIAL SAMPLES FOR LANDSCAPE ROCK MULCH TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO PROCUREMENT. LANDSCAPE BOULDERS, I PHOTO SUBMITTAL IS ADEQUATE. FOR ROCK MULCH, SUBMIT 1 GALLON BAG SAMPLE TO OWNER. Automatic Underground Irrigation Notes: A. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICH ENSURES COMPLETE COVERAGE AND PROPERLY ZONED FOR REQUIRED WATER USES. B. EACH HYDROZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS. I C. POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 18" AT PLANTER BEDS, 6" I AT LAWN AREAS.. D. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEMS - WITH DRIP CONTROL ZONE KIT AND 150 MESH FILTER (MIN.). F E. ELECTRONIC WATER DISTRIBUTION/ TIMING CONTROLLERS ARE TO BE PROVIDED. MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS: E.A. PRECISE INDIVIDUAL STATION TIMING C/ E.B. RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES LL if E.C. AT LEAST ONE PROGRAM FOR EACH HYDROZONE E.D. SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF E.E. POWER FAILURE BACKUP FOR ALL PROGRAMMED INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE WI HYDRO -ZONES. F. INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE LLJ WATER TO RESPECTIVE HYDRO -ZONES. J G. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING AS APPROPRIATE. C� H. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES SUCH AS SIDEWALKS DRIVEWAYS AND PARKING AREA. n I. EACH VALVE SHALL BE INSTALLED IN A VALVE BOX LARGE ENOUGH TO ALLOW FOR mot' MAINTENANCE AND REMOVAL. ONLY ONE VALVE PER BOX. Tree Protection Notes: d. A. PKUIEUI IHE UHI IIUAL HUUI LUNE OF IHE IHEES I HE HE IAINEU UN 611 E: NUIL: UHI IIGAL 4,* *,*,*,*.*.*.*.*.I .*.� �?� '.'.'.',',',I m ROOT ZONE IS THE AREA DIRECTLY BELOW THE DRIP LINE OF THE TREE.) .i.. * .La...'.'*'*' _ _ * ... . A.A. CONSTRUCT PROTECTIVE FENCING OF CHAIN -LINK AROUND THE CRITICAL ROOT ZONE r'� g PRIOR TO DEMOLITION OR CONSTRUCTION. A.B. DO NOT ALLOW COMPACTION BYEQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING I DEMOLITION. A.C. DO NOT ALLOW CEMENT TRUCKS TO RINSE WITHIN THE PROTECTION AREA ANYWHERE I I THAT TREE ROOTS EXIST OR IN PLANNED PLANTING BEDS. I A.D. DO NOT STOCKPILE MATERIALS DEBRIS OR DIRT WITHIN THE TREE PROTECTION AREA. I I I A.E. MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF NOT LESS THAN THE — _ I EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK. A.F. DO NOT TRENCH, EXCAVATE, FILL OR OTHERWISE DISTURB THE SOIL WITHIN THE CRITICAL ROOT ZONE. • • I A.G. ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE x I 1 ROOTS. ® 1 B. PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED ON SITE: ii X y_ X I B.A. OPERATE EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR I BRANCHES. I B.B. PRUNING OF PUBLIC PROPERTY TREES SHALL BE PERFORMED BY A LICENSED ARBORIST. I f'11 BEG C. ALL TREES DAMAGED OR DESTROYED DURING CONSTRUCTION SHALL BE REPLACED USING THE AMENDED PLAT OF GOLDEN EAGLE ESTATES R2 I L tU FOLLOWING CRITERIA: — — — — — — — J EXISTING TREE REPLACEMENT T 1" TO 6" CALIPER .........................2X CALIPER OF TREE REMOVED 0 10, 20' 6" TO 12" CALIPER ......................1.5X CALIPER OF TREE REMOVED > 12" OR LARGER CALIPER.........1X CALIPER OF TREE REMOVED EXAMPLE., IF AN 8" CALIPER TREE IS REMOVED, AN ACCEPTABLE REPLACEMENT WOULD BE (3) 4" CALIPER TREES OR (4) 3" CALIPER TREES. .� iF•M, �� � r� LAND GROUP cc O C0 E W LU O C� y O cc o co COD Ir M a' °° w CZ) o a, Revisions U 1. o ccff�� —1 888 03/04/2022 Project No.: 122008 Date of Issuance: 03.04.2022 Project Milestone: Conditional Use Permit Conditional Use Permit Landscape Plan X&IIII.J NOTES: 1. THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR A MINIMUM OF 1 YEAR. ALL STAKING SHALL BE REMOVED AT THE END OF THE ONE YEAR WARRANTY PERIOD. 2. IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING. 3. LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TO INSTALLATION OF PLANT MATERIAL. 4. WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR FIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE. 5. WATER TREE TWICE WITHIN THE FIRST 24 HOURS. 6. IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. In SOIL LINE UTILIZE SOIL/ROOT PROBE AROUND TRUNK (APPROX. 3-4" AWAY FROM TRUNK) TO LOCATE HIGHEST ROOTS. HIGHEST ROOTS SHOULD BE POSITIONED AT OR SLIGHTLY ABOVE GRADE LEVEL. �� \ REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP Y OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTIC \ \ FROM FOOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TO A VA \ WRAP THE ROOTBALL, IT SHALL BE COMPLETELY REMOVED. ONLY BIODEGRADEABLE BURLAP SHALL BE LEFT ON THE BOTTOM OF THE ROOTBALL wx' v x' x, Deciduous Tree Planting Scale: NTS MULCH LAYER v �v v N/i✓i.� COMMERCIAL FERTILIZER TABLETS Shrub Planting Scale: NTS 2x FOOTBALL DIAMETER 3x ROOTBALL DIAMETER WATER RETENTION BASIN BACKFILL WITH SOIL PLANTING MIX. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. REMOVE DEAD/DAMAGED BRANCHES AND PRUNE TO INTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS; IMPROPERLY PRUNED TREES (AS DETERMINED BY THE LANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED. PREVAILING WIND DIRECTION TREE WRAP TRUNK PROTECTION, REMOVE AFTER INSTALLATION RUBBER CINCH TIE 2" x 2" x 8' CEDAR STAKE - DO NOT PENETRATE ROOTBALL. SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND. MULCH LAYER, KEEP MULCH 3" AWAY FROM TRUNK X. SEE ISPECIFICALL TIONS ITH IL PLANTING I FOR ADDITIONALINFORMATION. COMMERCIAL SLOW RELEASE FERTILIZER TABLETS SET FOOTBALL ON NATIVE UNDISTURBED SUBSOIL -� OF—� � 0Y*A0 too'; WE LAND =GROUP cc W W u a) O v y 0 C9 o co ElmoQ CC M �o ,_ = w� o m CZ) Revisions 1. 0E OF 888\ "Y4NDSCA4 03/04/2022 Project No.: 122008 Date of Issuance: 03.04.2022 Project Milestone: CondNonal Use Permit Conditional Use Permit Landcape Details L1.50