Loading...
HomeMy WebLinkAboutCivilPlan2 V1I2 C h i n d e n B I v d 58 -- --------------------- 58 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------------------------------------------------ - - - - 59 - - - - - - - 59 5959.21 SW 59.31 SW Q 9 - h ro 58 58 58 5 55.85 SW _ � 57 �55.85 Sg SW 58.53 SW 58.30 BW 56 58.95 TW 55.90 BW 55.46 FL 58.95 TW S5.41 FL 55.06 FIL -- \� 55.96 FL 56.05 FL STM-1 54.92 TG 55.49 FL ° C5558 FL 55.64 fL SINGLE CURB INLET (24X 35.5") ssst FL �I 56.16 FL RIM= 2554.92 \\�s 55.67 FL T� I 55.27FL r' \^ S5.60 FL j 55.87 FL 56.14 FL b\ rn 56.08 FL m ' 0 _ 5 55.48 FL 3 J oy ® 56.21 FL 55.44 FL 55.20 fL STM-3 J 56.29 OR 56.2 1 BR 4" CLEANOUT 156.27 FL - 56.71 TR CONNECT TO ROOF DRAIN N� 2.00% 56.79 TR 1.50% 56.91 SW 2.26% RIM= 25a5.89 I 4" HDPE-5.54 _ LF 0 7.78% x ce STM-4 0 4" CLEANOUT _ 1,367 2.09% CONNECT TO ROOF DRAIN RIM_= 2556.95 10. a 5e 54.68 TG 4" HDPE-18.04 LF 0 7.78% STM-6 STM-2 5ss7 sw �� SINGLE CURB INLET (24" X 35.5") RIM= 2552.00 56.55 FL 56.15 FL RIM= 2554.68 s6s7 sw 56.06 FL LOST RAPIDS I 57.00 TW 56.50 GB PROPOSED 56.46 GB 56.00 FL DEVELOPMENT II LLC 57.00 BW rn - 0.50% o STRUCTURE 56.34 GB 3.00% 561.E FL 56.02 FL �_ PARCEL 5330760600 56.38 GB 56.50 GB 3,103 SF �PE-40.78 FF=2557.00 a. 1.67% O I I 55.94 FG 55.13 FL 54.89 FL 10" H LF 0 , 96% - -� { 55.25 FL 5 =.1 1s7% I I 1.71% H 55.27 FL 4" HIPE-17.34 LF 0 14.34% STM-1 h TT -. I 55.15 FL 54.75 FL o sssa FG NULL STRUCTURE STM-11 RIM= 2551.20 A 1.42% 4' CLEANOUT o 55.94 FG o0 CONNECT TO ROOF DRAIN 56.33 FL RIM= 2556.93 2. 50z 1.33% 10 2.11� STM 10" HDPE-61.65 LF 0 1,96% SINGLELE CURB INLET (24" X 35.5") � �o ® e - RIM= 2555.88 5 .26 fL 56.78 SW 0.00% 56.83 SW 1,50% - 56.83 SW 0 56.83 SW s6 I o - 56.70 SW I 56.74 SW 56.24 FL I 56.24 FL ® O ® I I B 41 56.18 FL 56.00 FL 56 56.03 FL I 56 55.93 FSTM-14 55.99 FIL O MH-ECCENTRIC (4' 0) 55.98 FL 56.02 FL 55.61 FL I .RIM= 2555.77" 1.os% 10" HDPE-48.59 LF 0 5.54% STM-10 MH-ECCENTRIC (4' 0) 11 ml RIM= 2555,31 O I --------- 55.47FL - -�O'• 55.40 FL 55.49FL 55.42 FL 55.74 fL 55.83 FL 56.23 FG 1 55.24 FL STM-13 ti 10" HDPE-25.23 LF 0 15.65% 55.12 FL MH-ECCENTRIC (4' 0) STM 5 RIM= 2555.55 55.87 SW 5 .Bs sw , 55.97 FL SINGLE CURB INLET (24" X 35.5") ®vy+ 55.16 FL 55.96 FL RIM= 2554.82 \ 54.82 TG 55.16 FL 9/0 55.18 TG 55.53 FL _ - - / 55.96 SW - - - - STM-9 / / 5s.02 SW SINGLE CURB INLET (24" X 35.5") STM-8 RIM= 2555.89 SINGLE CURB INLET (24' X 35.5") ti55 RIM= 2555.18 10" HDPE-20.30 LF 0 9.10% U COSTCO WHOLESALE CORP PARCEL- 5330760300 GRADING LEGEND --------5460-------- EXISTING MAJOR CONTOUR 52 EXISTING MINOR CONTOUR 5465 PROPOSED MAJOR CONTOUR 66 PROPOSED MINOR CONTOUR PROPOSED GRADE BREAK 15.00 PROPOSED SPOT ELEVATION 15.00 FF FINISHED FLOOR 15.00 FL FLOWLIINE 15.00 GB GRADE BREAK 15.00 ME MATCH EXISTING ® 15.00 SW SIDEWALK N15.00 15.00 fG FINISHED GRADE TR TOP Of RAMP 15.00 BR BOTTOM OF RAMP 0 10 20 SCALE: 1"=20' I 1 I I I _J r 75 56.96 SW ® o Sfi.46 FL s� 56.96 TR � 56.46 FL 0 56.46 BR 2.25% 56.46 BR 56.46 FL .99 � ~ 56.96 TR O RAMP DETAIL SCALE: 1" = 10' GRADING NOTES SITE LEGEND PROPERTY BOUNDARY LINE RIGHT OF WAY BOUNDARY LINE EXISTING EASEMENT UNE SETBACK UNE EXISTING TO REMAIN PROPOSED NEW FUTURE NEW EXISTING SIGN EXISTING UTILITY STUB MARKER EXISTING PAD MOUNTED TRANSFORMER ' EXISTING LIGHT POLE EXISTING SANITARY SEWER MANHOLE EXISTING STORM DRAIN MANHOLE - EXISTING STORM DRAIN INLET EXISTING WATER METER EXISTING WATER VALVE EXISTING IRRIGATION VALVE EXISTING CURB AND GUTTER OO ® PROPOSED SANITARY SEWER STRUCTURE ® PROPOSED STORM DRAIN STRUCTURE ® PROPOSED STORM DRAIN CATCH BASIN -SD PROPOSED STORM DRAIN T PROPOSED SIGN ® PROPOSED ADA PARKING SYMBOL ,m PROPOSED BIKE RACK PROPOSED CURB AND GUTTER PROPOSED RETAINING WALL I 56.56 FG 56.08 FL 56.13 EOC I56.00 FL I I55.97 FL IO� 55.96 FL I I55.95 FL 56.00 EOC I s�9 o 56.53 FG ,V�� 55.96 EOC I 56.05 EOC 55.97 EOC I I56.00 EOC I 55.87 FL 55.95 FL 1,\ 55.94 FL 55.85 FL 55.97 EOC I55,92 FL 55.96 EOC 55.97 EOC I I55.91 EOC 55.93 EOC 55.90 EOC 56.00 EOC - 55.93 EOC - 55.98 EOC - O TRASH ENCLOSURE DETAIL SCALE: 1" = 10' 1. REQUIREMENTS SHOWN ON SITE PLAN SHALL GOVERN. DRAWINGS AND SPECIFICATIONS SHOWING OTHERWISE NOThWTHSTANDING. CONTRACTOR TO POINT OUT ANY DISCREPANCIES TO THE ENGINEER OF RECORD PRIOR TO BID. 2. NO WORK IS TO BEGIN UNTIL ALL PERMITS HAVE BEEN OBTAINED. CONTRACTOR MUST HAVE COPIES OF ALL STATE AND LOCAL STORMWATER DISCHARGE AND EROSION CONTROL PERMITS ON SITE PRIOR TO ANY DISTURBANCE AND/OR GRADING ACTIVITY. 4. THIS DESIGN IS BASED ON A SOIL AND FOUNDATION INVESTIGATION. A COPY OF THIS REPORT IS AVAILABLE FOR INSPECTION BY THE CONTRACTOR. 5. ALL LANDSCAPING AREAS SHALL BE GRADED WITHIN 0.10' OF DESIGN WITH APPROVED TOP SOIL TO A MINIMUM DEPTH AS SPECIFIED BY THE LANDSCAPE ARCHITECT AND CITY SPECIFICATIONS. 6. ALL SPOT GRADES SHOWN ARE TO FLOWLINE UNLESS OTHERWISE NOTED. 7. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR MINIMIZING DEPOSITION OF ONSITE SEDIMENTS ONTO SURROUNDING PUBLIC STREETS DURING CONSTRUCTION, REFER TO EROSION CONTROL PLANS AND DETAILS FOR INFORMATION. 8. GENERAL CONTRACTOR SHALL PROVIDE BARRICADE PROTECTION AS REQUIRED BY THE CITY AROUND ALL FOOTINGS, EXCAVATIONS AND ALL OFFSITE WORK. 9. THE PROPOSED STORM SEWER SYSTEM ON -SITE IS PRIVATELY OWNED AND MAINTAINED. 10. ANY FILL MATERIAL REQUIRED TO BRING THE SITE TO GRADE SHALL BE CLEAN FILL DIRT APPROVED BY GEOTECHNICAL ENGINEER AND SHALL BE PLACED AND COMPACTED PER GEOTECHNICAL REPORT RECOMMENDATIONS. 11. TOP OF GRATE (TOG) AND FLOWLINE (FL) SPOT GRADES AT INLETS DO NOT INCLUDE GUTTER DEPRESSION. CAUTION - NOTICE TO CONTRACTOR 1. ALL UTIUTY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTIUTY COMPANY AND FIELD SURFACE 0 EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY To FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIESTO THE KnowwhaYsbelow. ENGINEER PRIOR TO CONSTRUCTION. Call before you dig. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. Gall"lowayIII 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 GallowayUS.com J �� p�'P o, QZ�p -PPP COPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF GALLOWAY. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 4 0 Cn 0 Q C U) 4LU m Z � W 0 0 0 O O = z � � z W W Q Q J O 0:� W 0) of co W M # 1 Date 4120/22 Issue / Description 1st CUP Submittal Init. DJS Project No: Drawn By: KSB Checked By: DJS Date: 2022.04.14 GRADING PLAN C2.0