HomeMy WebLinkAboutDrawings 10 V1EXISTING EXISTING
ILTE
AN ANPROPOSED
ANTENNA AEOK+AEQU ANTENNA
STACKED
ANTENNAS
APPROVED
M1E 0S/1822
EXISTING INTEGRATED
iIU NUMNA:^-�� WITHIN: EXISTING
RRH UNIT AIRSCALE RRH UNIT
MAA 64T64R
192AE N77
200W AEQK,
AEQU EXISTING
—
VC -PROPOSED
G \\ � V, DC9 RAVCA
� I G
G G G�
G G G G ,
G
� G � G G� cT
I I #2 AWG GREEN STRANDED
GROUND FROM DC9 TO
#2 AWG GREEN STRANDED SECTOR GROUND BAR
GROUND FROM RRH TO 0
SECTOR GROUND BAR (TYP) I I EXISTING SECTOR GROUND
BAR (TYR)
EXISTING#2AWGGROUND
LEADS (GC TO FIELD
VERIFY)
SSE EEEE ii EXISTING GROUND BAR AT
BASE OF TOWER
ER TOW
L7 �
EXISTING #2 AWG GROUND
LEADS IS TO FIELD
'n VERIFY)
11
EXISTING#2AWG GROUND WIRE
FROM EQUIPMENT TO MGB (TYP)
EXISTING UMTS
CABINET
EXISTING GROUND LEVEL
EXISTING EQUIPMENT MASTER
GROUND BAR (MGB)
EXISTING ARGUS
POWER PLANT
r EXISTING GSM
CABINET
EXISTING BBU (2 TOTAL, 1
SHOWN FOR CLARITY)
EXISTING (2) LTE
CABINETS (STACKED)
-'&
/-.-%
.04
\
�'
TYPE HS
TYPIIIE��E2-YA-2
TYPE XA
TYPE YA-2
TYPE GT
...
—I
1so-
TYPE TA
TYPE VN
TYPE NC
TYPE SS
p
Lj�T�'
TYPE GY
o.20'
DsgD'
U25'5
1.20'
2.000'
_V
TYPE W
TYPE VS
TYPES"
TYPE VB TYPE PT
SHOWN HERE ARE EXAMPLES.
LJ
TYPE OR
CONSULT WITH
I INS 415ON
IL INSULATION
NO. WBKT1
WALL BRACKET
2875'
3.500'
4.000
NOTE:
ERICO EXOTHERMIC'MOLD
PROJECT MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT.
EXOTHERMIC WELDING SNTTASLE. 4
1 12" & 18" GROUND BARS
FROM ANTENNA —
PROOFING
KIT (TYR)
FROM ANTENNA
FRAME SUPPORT
I
5G 20 (4)
437.00(26)
SCALE:
NTS I
APPROVED
RX GROUNDING
KIT (TYR)
ANTENNA CABLE TRAY
TO CABLE TRAY (TYR)
#6 AWG
#2 AWG BCW BONDED
TO GROUND WIRE
ALONG CABLE TRAY
#2 AWG BCW — t— GROUNDING BAR MOUNTED NEAR ANTENNAS
NOTE: DO NOT INSTALL CABLE GROUND KIT AT A BEND
NOT USED NTS 5 I COAX GROUNDING DETAIL NTS 2
WIRE SIZE
BURNDYLUG
BOLT SIZE
#2 AWG SOUDTINNHD
YA3C-M
3VJ6NCS2BOLT
42 AWG STRANDED
YA2C-M
3V-16 NC 2BOLT
4210AWGSTRANDED
YA26-f
aV-16 NC S 2 BOLT
WOAWGSTRANDED
YAWN
3VJ6NCS2BOLT
NOTES:
1. ALL HARDWARE BOLT, NUTS, LOCK
WASHERS SHALL BE STAINLESS STEEL. ALL
HARDWARE ARE TO BE AS FOLLOWS: BOLT,
FLAT WASHER, GROUND BAR, GROUND LUG,
FLAT WASHER AND NUT.
2. COPPER SHIELD, ANTIOX, CR NO-OX OR
EQUIVALENT SHALL BE PLACED WHERE ALL
DISSIMILAR METALS CONNECT.
3. ALL LUGS TO BE INSTALLED PER
MANUFACTURERS SPECIFICATIONS.
4. ALL RRH GROUND WIRES SHALL BE #2
GREEN STRANDED.
S. ALL GROUND LUGS SHALL BE 2-HOLE, LONG
BARREL.
6. OUTDOOR GROUND LUGS SHALL BE BLACK
HEAT SHRINK W/O INSPECTION HOLES.
7. INDOOR GROUND LUGS SHALL BE CLEAR
HEAT SHRINK W/ INSPECTION HOLES.
HEAT SHRINK (CLEAR)
BURNDY GROUND LUG
(SEE TABLE FOR SIZE
AND MODEL)
NUT (TYR)
LOCK
WASHER
(TYP)
GROUND BAR J / GROUNDING
BOLT(TYP) J CONDUCTOR
BURNDY TWO HOLE LUG W/ LONG
BARREL FOR #2 AWG STRANDED
OR EQUIVALENT
BARE WIRE TO BE NO-OX AT BOTH
ENDS
#2 AWG STRANDED
GREEN INSULATION
LTYPICAL GROUNDING SCHEMATIC NTS 7 I NOT USED NTS 6 I MECHANICAL LUG CONNECTION r I
NTS
Vaw
gsmartlink
Smart)ink LLC
Kn I a ue
TRILEAF
architecture I engineering
1516 DES PERES ROAD, STE 20D
SAINT LOUIS, M18SOURI 63131
xilata-w�-ettt rnn lata-x�-eox
694351
REVISIONS
oESCaiPnOx
Ew so%
c L
l' Q
1
n A
r0 �OF\OP
\R ALW4 �\
SITE INFORMATION
SITE #: IDLO2037
SITE NAME: MERIDIAN 2
FA #: 10115130
704 FRANKLIN ROAD WEST
MERIDIAN, ID 83642
SHEEP TITLE:
GROUNDING
DETAILS
SHEET NUMBER:
G-1