HomeMy WebLinkAboutGN-1, General Notes V1NRE HAS BEEN MADE IN THE CONSTRUCTION DOCUMENTS TO PROVIDE A
COPE OF WORK.MINOR DISCREPANCIES IN THE DRAWINGS AND/OR
NS SHALL NOT EXCUSE CONTRACTORS FROM COMPLETING THE PROJECT AND
TS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS.
ALL RE ENCES TO OWNER HEREIN SHALL BE CONSTRUED TO MEAN THE CARRIER OR
ATED REPRESENTATIVE.
BIDDING REQUIREMENTS
a. PRIOR TO THE SUBMISSION OF BIDS, VISIT THE JOB SITE TO BECOME FAMILIAR WITH
ALL CONDITIONS AFFECTING THE PROPOSED PROJECT. VISIT THE SITE WITH THE
CONSTRUCTION DOCUMENTS TO VERIFY FIELD DIMENSIONS AND CONDITIONS TO
CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN.
b. PROVIDE NOTIFICATION TO OWNER IN WRITING OF ANY CONFLICTS, ERRORS, OR
OMISSIONS PRIOR TO SUBMISSION OF PRICE PROPOSAL. IN THE EVENT OF
DISCREPANCIES, PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED
OTHERWISE.
c. WHEN TOWER IS OWNED BY A THIRD PARTY, CONTACT TOWER OWNER REPRESENTATIVE
FOR PARTICIPATION IN BID WALK.
d. WHERE ANCHORING TO A CONCRETE ROOF SLAB, CONFIRM (PRIOR TO SUBMITTING
BID) THE PRESENCE OF POST TENSION TENDONS. INCLUDE PROVISIONS FOR X—RAY
PROCEDURES TO LOCATE THE TENDONS PRIOR TO CONSTRUCTION.
4. DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS TAKE PRECEDENCE.
CONSTRUCTION DOCUMENTS ARE INTENDED FOR DIAGRAMMATIC PURPOSES ONLY, UNO.
5. FIELD VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS PRIOR TO
BEGINNING ANY MATERIALS ORDERING, FABRICATION OR CONSTRUCTION WORK ON THIS
PROJECT. BRING ANY DISCREPANCIES IMMEDIATELY TO THE ATTENTION OF THE OWNER
AND RESOLVE BEFORE PROCEEDING WITH THE WORK.
6. FURNISH ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS NECESSARY TO
COMPLETE PROJECT AS DESCRIBED IN THE CONSTRUCTION DOCUMENTS.
7. SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONSTRUCTION DOCUMENTS.
PROVIDE ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND
PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT.
8. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT
ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GIVE ALL
NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL
ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS,
AND LOCAL AND STATE JURISDICTIONAL CODES APPLICABLE TO THE WORK.
9. CONSTRUCTION COORDINATION REQUIREMENTS
0. NOTIFY OWNER OF ANY DISCREPANCIES PRIOR TO START OF WORK.
b. OBTAIN ALL PERMITS. SCHEDULE AND COORDINATE ALL INSPECTIONS.
C. PROVIDE, AT THE PROJECT SITE, A FULL, CURRENT SET OF CONSTRUCTION
DOCUMENTS FOR USE BY ALL PERSONNEL INVOLVED WITH THE PROJECT.
d. RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO
STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION
DOCUMENTS.
e. PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL
BUSINESS.
f. PROVIDE FALL PROTECTION IN ACCORDANCE WITH FEDERAL, STATE, LOCAL, AND
OWNER REQUIREMENTS.
g. IF FAA LIGHTING AND MARKING IS PRESENT ON SITE AND IS POWERED BY
ELECTRICAL SERVICE THAT IS TO BE INTERRUPTED, MAINTAIN THE NECESSARY LIGHTS
DURING CONSTRUCTION AND NOTIFY THE PROPER AUTHORITIES IN THE EVENT OF A
DISRUPTION.
h. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2—A
OR 2—A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA
DURING CONSTRUCTION.
I. STRUCTURAL COMPONENTS OF ADJACENT FACILITIES SHALL NOT BE ALTERED BY THIS
CONSTRUCTION PROJECT, UNO. ENSURE THAT EXCAVATION DOES NOT AFFECT
ADJACENT STRUCTURES.
j. SEAL ALL PENETRATIONS THROUGH FIRE —RATED AREAS WITH U.L. LISTED OR FIRE
MARSHALL—APPROVED MATERIALS, IF APPLICABLE.
k. BURIED UTILITIES MAY EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT
BE COMPLETE. CONTACT THE UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS
PRIOR TO CONSTRUCTION.
I. COORDINATE ALL POWER INSTALLATION WITH POWER COMPANY AS REQUIRED. REPORT
POWER INSTALLATION COORDINATION SOLUTION(S) TO OWNER.
- PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING
CONSTRUCTION. UPON COMPLETION OF WORK, REPAIR ANY DAMAGE THAT MAY HAVE
OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY.
n. KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND
DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. REMOVE EQUIPMENT NOT SPECIFIED
AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN
CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE.
0. MAINTAIN THE INTEGRITY OF THE BUILDING ENVELOPE AND CONSTRUCT BARRIERS IN
THE AREA OF WORK TO PREVENT DAMAGE FROM WEATHER AS WELL AS FROM
CONSTRUCTION DUST AND DEBRIS.
10. INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S SPECIFICATIONS,
UNO, OR WHERE LOCAL CODES OR ORDINANCES DIRECT OTHERWISE.
11. PROPOSED CELLULAR EQUIPMENT AND FIXTURES WILL BE FURNISHED BY OWNER AND
INSTALLED BY CONTRACTOR, UNLESS NOTED OTHERWISE.
12. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY OWNER.
13. DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP THE APPROVED
CONSTRUCTION DRAWINGS AND SUBMITTING THE REDLINED SET TO OWNER UPON
COMPLETION. DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS TO BE SUBMITTED
WITH REDLINED CONSTRUCTION DRAWINGS.
14. PROVIDE SUPPORTS FOR CABLES TO THE ELEVATION OF ALL INITIAL AND FUTURE
ANTENNAS IN ACCORDANCE WITH ALL MANUFACTURER'S REQUIREMENTS.
15. CONFIRM THAT THE REQUIREMENTS OF THE STRUCTURAL ANALYSIS, MOUNT ANALYSIS AND
ANY ASSOCIATED MODIFICATIONS HAVE BEEN FOLLOWED AND COMPLETED AS REQUIRED TO
SUPPORT THE EQUIPMENT ASSOCIATED WITH THIS PROJECT.
A/C
ABBREVIATIONS
AIR CONDITIONING
MGR
MANAGER
AFF
ABOVE FINISHED FLOOR
MIN
MINIMUM
AGL
ABOVE GROUND LEVEL,
MISC
MISCELLANEOUS
ABOVE GRADE LEVEL
NA
NOT APPLICABLE
AWS
ADVANCED WIRELESS SERVICE
NIC
NOT IN CONTRACT
BBU
BATTERY BACKUP UNIT
NO
NUMBER
BLDG
BUILDING
NTS
NOT TO SCALE
BLK
BLOCKING
OC
ON CENTER
CLG
CEILING
OD
OUTSIDE DIAMETER
CUR
CLEAR
PCS
PERSONAL COMMUNICATION SERVICE
CONIC
CONCRETE
PDU
POWER DISTRIBUTION UNIT
CONE
CONTINUOUS
PROJ
PROJECT
D
DEPTH
PROP
PROPERTY
DBL
DOUBLE
PT
PRESSURE TREATED
DEG
DEGREE
PVC
POLYVINYL CHLORIDE
0, DIA
DIAMETER
RE Q
REQUIRED
DIAG
DIAGONAL
RE
RADIO FREQUENCY
ON
DOWN
RM
ROOM
DET
DETAIL
RO
ROUGH OPENING
DWG
DRAWING
RRH
REMOTE RADIO HEAD
E
EXISTING
SHT
SHEET
EA
EACH
SIM
SIMILAR
ELEV,
EL ELEVATION
SPEC
SPECIFICATION
ELEC
ELECTRICAL
SF
SQUARE FOOT
EQ
EQUAL
SS
STAINLESS STEEL
EQUIP
EQUIPMENT
STL
STEEL
EXT
EXTERIOR
SUSP
SUSPENDED
FIF
FIBER INTERFACE FRAME,
TMA
TOWER MOUNTED AMPLIFIER
FACILITY INTERFACE FRAME
TND
TINNED
FIN
FINISH
TYP
TYPICAL
FLUOR
FLUORESCENT
UMTS
UNIVERSAL MOBILE
FLR
FLOOR
TELECOMMUNICATION SERVICE
FT
FOOT, FEET
UNO
UNLESS NOTED OTHERWISE
GA
GAUGE
VERT
VERTICAL
GALV
GALVANIZED
W/
WITH
GC
GENERAL CONTRACTOR
W/O
WITHOUT
GRND
GROUND
WCS
WIRELESS COMMUNICATION
GSM
GLOBAL SYSTEM MOBILE
SERVICE
GYP
GYPSUM BOARD
WP
WATER PROOF
HORZ
HORIZONTAL
AR
HOUR
HE
HEIGHT
ID
INSIDE DIAMETER
IN
INCH, INCHES
INSUL
INSULATION
INT
INTERIOR
L
LENGTH
LEIS
POUNDS
LTE
LONG TERM EVOLUTION
MAX
MAXIMUM
MECH
MECHANICAL
MTL
METAL
MFR
MANUFACTURER
I PROJECT NOTES
1. THE FOLLOWING INFORMATION HAS BEEN PROVIDED BY CROWN CASTLE FOR
THIS PROJECT AND HAS NOT BEEN FIELD VERIFIED AS PART OF THIS
PROJECT.
0. SITE LAYOUT INFORMATION AND ORIENTATION
b. EXISTING TOWER, MOUNT AND EQUIPMENT ELEVATIONS
c. DESIGN PACKAGE BASED ON THE APPLICATION #: PENDING YO
2. A STRUCTURAL ANALYSIS TO DETERMINE THE TOWER CAPACITY TO SUPPORT
THIS PROPOSED EQUIPMENT WAS PERFORMED FOR CROWN CASTLE OUTSIDE
THE SCOPE OF THIS PROJECT.
0. STRUCTURAL ANALYSIS BY: OTHERS
b. DATED: PENDING
c. RESULTS: PENDING
3. A MOUNT ANALYSIS TO DETERMINE THE MOUNT CAPACITY TO SUPPORT THIS
PROPOSED EQUIPMENT WAS PERFORMED FOR CROWN CASTLE OUTSIDE THE
SCOPE OF THIS PROJECT.
0. MOUNT ANALYSIS BY: INFINIGY GROUP
b. DATED: 04/06/2022
c. RESULTS: T—ARM IS SUFFICIENT
4. CONFIRM THAT THE REQUIREMENTS OF THE STRUCTURAL ANALYSIS AND ANY
ASSOCIATED MODIFICATIONS HAVE BEEN FOLLOWED AND COMPLETED AS
REQUIRED TO SUPPORT THE EQUIPMENT ASSOCIATED WITH THIS PROJECT.
AT&T
161 INVERNESS DRIVE
WPST ENGLEWOOD, CO 80112
ccCROWN
CASTLE
2055 S. STEARMAN DRIVE
CHANDLER AL 85296
O
rTElr VT`
TNFR Ic.es
3950 N HIGLEY RD - SUITE 102, R V
MESA AZ 85215
AT&T SITE NUMBER:
ML02324
BU #: 839266
1776 NORTH AVEST LANE
MERIDIAN, ID 83642
EXISTING 100'-0" MONOPOI
r
ISOM
Q
sEwxFE"s.m�a�
SIIAETNUMBER: REVISION:
GN-1 0