HomeMy WebLinkAboutPRIOR APPROVALS 2 - 2100 S. Silverstone Way V1E IDIAN —
APPROVED
DATE 05/17/22
FILE NUMBER:^-2022 00e
FILE NUMBER: A-2022-1
Planning Division
El Community Development Department
D A H O 33 E. Broadway Avenue, Suite 102
Meridian, Idaho 83642
CERTIFICATE OF ZONING COMPLIANCE REPORT
Project Number
A-2022-0037
Project Name
Crown Castle For Verizon @ 2100 S.
Silverstone Way CZC
Project Address
2100 S. Silverstone Way
Project Description
Eligible Facility Request to modify an existing
Verizon wireless facility on 7.061 acres of land
in the C-G zoning district:
Remove (3) antennas
Install (6) antennas
Install (3)is
Applicant
Gary Abrahams, GMA Network Services
Assigned Planner
Stacy Hersh
Expiration Date
February 28, 2023
Note: This is not a building permit. Please contact Building Services at (208) 887-2211
to verify if you need a building permit and/or inspection. If you do need a building
permit, you must complete that process before you commence the use or construction.
Please contact Building Services for additional details about building permits and
inspections.
I. DECISION
The applicant's request for Certificate of Zoning Compliance is approved with the conditions
listed below.
Site Specific Conditions of Approval
I . The applicant shall construct all proposed fencing and/or any fencing required by the UDC,
consistent with the standards as set forth in UDC 11-3A-7 and 11-3A-6B.
2. No signs are approved with this application. Prior to installing any signs on the property, the
applicant shall submit a sign permit application consistent with the standards in UDC Chapter
3 Article D and receive approval for such signs.
3. The applicant shall complete all improvements related to public life, safety, and health as set
forth in UDC 11-5C-3B. A surety agreement may be accepted for other improvements in
accord with UDC 11-5C-3C.
4. The applicant shall pay any applicable impact fees prior to the issuance of a building permit.
5. If any changes must be made to the site plan to accommodate ACHD requirements, the
applicant shall submit a new site plan to the City of Meridian Planning Division for approval
prior to issuance of the building permit.
6. The applicant shall complete all required improvements prior to issuance of a Certificate of
Occupancy. It is unlawful to use or occupy any building or structure until the Building
Official has issued a Certificate of Occupancy.
11Page
E IDIAN —
APPROVED
DATE 05/17/22
FILE NUMBER:^- Doz 00e
FILE NUMBER: ^-zozzu0a�
Conditions of Approval
The applicant and/or assigns shall have the continuing obligation to provide irrigation that
meets the standards as set forth in UDC 11-313-6 and to install and maintain all landscaping
as set forth in UDC 11-313-5, UDC 11-313-13 and UDC 11-313-14.
2. The issuance of this CZC does not release the applicant from any previous requirements of
the other permits issued for the site.
3. The applicant and/or property owner shall have an ongoing obligation to prune all trees to a
minimum height of six feet above the ground or sidewalk surface to afford greater visibility
of the area.
4. The applicant has a continuing obligation to comply with the outdoor lighting provisions as
set forth in UDC 11-3A-11.
5. The applicant and/or property owner shall have an ongoing obligation to maintain all
landscaping and constructed features within the clear vision triangle consistent with the
standards in UDC 11-3A-3.
6. The applicant and/or assigns shall have the continuing obligation to meet the specific
use standards for the proposed use as set forth in UDC 11-4-3-43, wireless
communication facility.
II. CITY COUNCIL REVIEW
The applicant or a parry of record may request City Council review of a decision of the Director.
All requests for review shall be filed in writing with the Planning Division on or before March 15,
2022, within fifteen (15) days after the written decision is issued, and contain the information
listed in UDC 11-5A-6B.
If City Council review of the decision is not requested, the action of the Director represents a
final decision on a land use application. You have the right to request a regulatory taking analysis
under Idaho Code 67-8003.
2 1 Page
(�j�ERO)IAN}-
APPROVED
CAM. W17M2
FUN-
VERIZON SITE NUMBER: 167122
VERIZON SITE NAME:
SITE TYPE:
TOWER HEIGHT:
SITE INFORMATION
CROWN CASTLE USA INC.
BOISE CALL CENTER
SITE NAME:
SITE ADDRESS:
2100 S SILVERSTONE WAY
MERIDIAN, ID 83642
COUNTY:
ADA
MAP/PARCEL #:
276000023873000
AREA OF CONSTRUCTION:
EXISTING
LATITUDE:
43' 35' 8.44"
LONGITUDE:
-1160 20' 58.42"
LAT/LONG TYPE:
NAD83
GROUND ELEVATION:
2722 FT
CURRENT ZONING:
O/I
JURISDICTION:
CITY OF MERIDIAN
OCCUPANCY CLASSIFICATION:
U
TYPE OF CONSTRUCTION:
II-C
A.D.A. COMPLIANCE:
FACILITY IS UNMANNED AND NOT FOR
HUMAN HABITATION
PROPERTY OWNER:
ELMWOOD PARK, THE VILLAGE OF
3131 TAYLOR AVE
RACINE, WI 53405
TOWER OWNER:
CROWN CASTLE
2000 CORPORATE DRIVE
CANONSBURG, PA 15317
CARRIER/APPLICANT:
VERIZON WIRELESS
3245 158TH AVENUE MS 231
BELLEVUE, WA 98008
ELECTRIC PROVIDER: IDAHO POWER
(800)488-6151
TELCO PROVIDER: CENTURY LINK
PROJECT TEAM
A&E FIRM:
CROWN CASTLE USA INC.
2000 CORPORATE DRIVE
CANONSBURG, PA 15317
CRO WNAE.APPRO VAL@CRO WNCASTLE. C OM
CROWN CASTLE
2055 S. STEARMAN DRIVE
USA INC. DISTRICT
CHANDLER, AZ 85286
CONTACTS:
---- - PROJECT MANAGER
---- - CONSTRUCTION MANAGER
VERIZON ANDREW LEONE
CONTACT: ALEONE@STRUCTURECONSULTING.NET
veri
MAVERICK
MONOPOLE
110'-0"
zc)nv
BUSINESS UNIT #: 822731
2100 S
SITE ADDRESS: MERIDIAN, SILVERSTONE ID 83642 WAY
COUNTY: ADA
JURISDICTION: CITY OF MERIDIAN
VERIZON FUZE PROJECT #: 16586623
DRAWING INDEX
SHEET #
SHEET DESCRIPTIOi
T-1
TITLE SHEET
T-2
GENERAL NOTES
C-1
SITE PLAN
C-2
TOWER ELEVATION
C-3
ANTENNA PLANS
C-4
EQUIPMENT SCHEDULES
C-5
EQUIPMENT DETAILS
C-6
PLUMBING DIAGRAM
G-1
GROUNDING DETAILS
G-2
GROUNDING DETAILS
ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR
FULL SIZE. CONTRACTOR SHALL VERIFY ALL PLANS AND
EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE
AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN
WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING
WITH THE WORK OR BE RESPONSIBLE FOR SAME.
APPROVALS
SIGNATURE 1);1TE
CONTRACTOR PMI REQUIREMENTS
PMI ACCESSED AT https://pmi.vxwsmart.com
SMART TOOL VENDOR
PROJECT NUMBER 16586623
VzW LOCATION CODE (PSLC) 167122
I *** PMI AND REQUIREMENTS ALSO EMBEDDED IN MOUNT I
ANALYSIS REPORT
MOUNT MODIFICATION REQUIRED I N
VzW APPROVED SMART HIT VENDORS
IREFER TO MOUNT MODIFICATION DRAWINGS PAGE FOR I
VzW SMART KIT APPROVED VENDORS
LOCATION MAP
15
W-SILVERKING ST
N
F N43° 35.14r
W I l6' 20974'
�E GOLDS,�QZIE.DR
E COPPER POWT DR
Rr/ty�.rr /! �rayi/
Ridrirauo
-EBEN CANYD_ N_OR
-
L---
�IJd'�uz�r
NO SCALE
DRIVING DIRECTIONS FROM BOISE INTERNATIONAL AIRPORT: HEAD WEST ON W AIRPORT WAY TOWARD S OWYHEE ST. SLIGHT RIGHT ONTO S OWYHEE ST.
TURN LEFT ONTO W WRIGHT ST. TURN RIGHT ONTO S ORCHARD ST. USE THE LEFT 2 LANES TO TURN LEFT TO MERGE WITH I-84 W TOWARD NAMPA/CALDWELL.
MERGE WITH I-84 W. TAKE EXIT 46 FOR ID-55 N TOWARD EAGLE/MCCALL. KEEP LEFT AT THE Y JUNCTION TO CONTINUE TOWARD ID-55/S EAGLE RD. USE ANY
LANE TO TURN LEFT ONTO ID-55/S EAGLE RD. KEEP LEFT TO CONTINUE ON S EAGLE RD. TURN LEFT ONTO E GOLDSTONE DR. SHARP RIGHT.
TURN LEFT. TURN RIGHT.
APPLICABLE CODES/REFERENCE
DOCUMENTS
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH
THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL
GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT
WORK NOT CONFORMING TO THESE CODES:
CODE TYPE CODE
BUILDING 2018 IBC
MECHANICAL 2018 IMC
ELECTRICAL 2017 NEC
REFERENCE DOCUMENTS:
STRUCTURAL ANALYSIS:
DATED:
MOUNT ANALYSIS:
DATED:
RFDS REVISION:
DATED:
ORDER ID:
REVISION:
CROWN CASTLE
01/07/2022
MASER CONSULTING
12/02/2021
1
6/29/2021
597816
0
e
CALL IDAHO ONE CALL
(800) 342-1585 0 .
CALL 3 WORKING DAYS's0
BEFORE YOU DIG!
PROJECT DESCRIPTION
THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND
CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE
WIRELESS FACILITY.
TOWER SCOPE OF WORK:
• REMOVE (3) ANTENNAS
• INSTALL (6) ANTENNAS
• INSTALL (3) RRHs
NOTE:
PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT
THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION
MANAGER
'
verizonv
3245 158TH AVENUE MS 231
BELLEVUE, WA 98008
lddl' �
CROWN
v CASTLE
1505 WESTLAKE AVENUE NORTH, SUITE 800
SEATTLE, WA 98109
TOWER ENGINEERING PROFESSIONALS
4710 E ELWOOD ST, STE 9
PHOENIX, AZ 85040
OFFICE: (480) 285-0036
www.tepgroup.net
VERIZON SITE NUMBER:
167122
BU #: 822731
BOISE_CALL_CENTER
2100 S SILVERSTONE WAY
MERIDIAN, ID 83642
EXISTING 110'-0" MONOPOLE
14
ISSUED FOR:
REV
DATE
DRWN
DESCRIPTION
DES./Q
0
01/19/22
ORG
CONSTRUCTION
HMM
01/19/22
Graham M. Andres, P.E.
Professional Engineer License: #15814
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER
REVISION:
T-1
0
No Text
APPROVED
.-- 05M7,22
(E) VERIZON EQUIPMENT
TO BE REMOVED
(3) ANTENNAS
MOUNTED ON EXISTING MOUNTS
(E) VERIZON EQUIPMENT TO REMAIN
(9) ANTENNAS
(6) RRUS
(3) OVP BOX
MOUNTED ON EXISTING MOUNTS
VERIZON EQUIPMENT
ANTENNA CL: 81'-0'
Ilk MOUNT CL: 79'-0"
TOP OF APPURTENANCE
ELEV. = 112'-0"
HEIGHT OF STRUCTURE
ELEV. = 110'-0"
EXISTING MCL h
ELEV. = 108'-0"
EXISTING MCL
ELEV. = 95'-0"
EXISTING MCL
ELEV. = 86'-0"
EXISTING VER170N ACT
ELEV. = 81'-0"
EXISTING VERIZON MCL
ELEV. = 79'-0"
(E) VERIZON FEEDLINE TO REMAIN
(3) HYBRID CABLE (602)
(E) 110'-0" MONOPOLE
I EXISTING TOWER ELEVATION
1/8"=1'-0" (FULL SIZE)
SCALE:
8' 6' 4' 2' 0 8' 1/16"— V-0" (llxl7)
(N) VERIZON EQUIPMENT
(3) COMMSCOPE / NHHSS-65C—R2B
(3) ERICSSON / AIR 6449
(3) ERICSSON / RADIO 4408
INSTALLED ON EXISTING MOUNTS
(E) VERIZON EQUIPMENT
(9) ANTENNAS
(6) RRUS
(3) OVP BOX
MOUNTED ON EXISTING MOUNTS
VERIZON EQUIPMENT
ANTENNA CL: 81'-0"
MOUNT CL: 79'-0"
(E) VERIZON FEEDLINE
(3) HYBRID CABLE (6xl2)
(E) 110'-0" MONOPOLE
NEW TOWER ELEVATION
L SCALE: 1/8"-1'-0" (FULL SIZE)
8' 6' 4' 2' 0 8' 1/16"—V-0" (11xl7)
TOP OF APPURTENANCE OIL
ELEV. = 112'-0"
HEIGHT OF STRUCTURE OL
ELEV. = 110'-0"
EXISTING MCL h
ELEV. = 108'-0"
EXISTING MCL
ELEV. = 95'-0"
EXISTING MCL
ELEV. = 86'-0"
NEW VERIZON ACL
ELEV. = 81'-0"
EXISTING VERIZON ACL
ELEV. = 81'-0"
EXISTING VERIZON MCL a
ELEV. = 79'-0"
verizonv'l
3245 158TH AVENUE MS 231
BELLEVUE, WA 98008
CROWN
CASTLE
1505 WESTLAKE AVENUE NORTH, SUITE 800
SEATTLE, WA 98109
TOWER ENGINEERING PROFESSIONALS
4710 E ELWOOD ST, STE 9
PHOENIX, AZ 85040
OFFICE: (480) 285-0036
www.tepgroup.net
VERIZON SITE NUMBER:
167122
BU #: 822731
BOISE_CALL_CENTER
2100 S SILVERSTONE WAY
MERIDIAN, ID 83642
EXISTING 110'-0" MONOPOLE I
14
ISSUED FOR:
REV
DATE
DRWN
DESCRIPTION
DES./QA
0
01/19/22
ORG
CONSTRUCTION
IIYL'VI
01/19/22
Graham N1. Andres, P.L.
Professional Engineer License: #15814
1T 1S A VIOLATION OF LAW FOR ANY PERSON,
UNLESS TIILY ARE ACTING UNDER TIIE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER TI IIS DOCUMENT.
14
SHEET NUMBER: REVISION:
C-2 0
J
APPROVED
.__ 0 M722
(E) 110'-0" MONOPOLE
(E) VERIZON ANTENNA TO BE REMOVED
COMMSCOPE — NHH-65B—R28
(3 TOTAL, 1 RER SECTOR)
(E) PLATFORM MOUNT TO REMAIN
(3 TOTAL, 1 PER SECTOR)
(E) VERIZON RAYCAP TO REMAIN
(3) RFS/CELWAVE — DBB1-6C-12AB-0Z
(E) VERIZON RRH TO REMAIN
ERICSSON RADIO 4449 313/B5
(3 TOTAL, 1 PER SECTOR)
(E) PLATFORM MOUNT
(3 TOTAL, 1 PER SECTOR)
(E) VERIZON RAYCAP
(3) RFS/CELWAVE — DBB1-6C-12AB—OZ
(E) 110'-0" MONOPOLE
(E) VERIZON RRH TO REMAIN
ERICSSON RADIO 8843 B2/B66A
(3 TOTAL, 1 PER SECTOR)
EXISTING ANTENNA PLAN
SCALE: . .
m
O �Q'
ti P�
�,) NEW ANTENNA PLAN
L SCALE: 1/2"=1'—O" (FULL SIZE) L
2' 1' 0 2' 1/4"=1'—O" (11x17) IV
(E) VERIZON ANTENNA TO REMAIN
ERICSSON — AIR 5331
(3 TOTAL, 1 PER SECTOR)
(E) VERIZON RRH TO REMAIN
ERICSSON RADIO 4449 B13/B5
(3 TOTAL, 1 PER SECTOR)
(E) VERIZON RRH TO REMAIN
ERICSSON RADIO 8843 B2/B66A
(3 TOTAL, 1 PER SECTOR)
(E) VERIZON ANTENNA TO REMAIN
COMMSCOPE — NHH-65B—R2B
(3 TOTAL, 1 PER SECTOR)
(E) VERIZON ANTENNA TO REMAIN
ANTEL — BXA-80063/4CF
(3 TOTAL, 1 PER SECTOR)
— (E) VERIZON ANTENNA
ANTEL — BXA-80063/4CF
(3 TOTAL, 1 PER SECTOR)
—NEW VERIZON ANTENNA
(3) ERICSSON — AIR 6449 B77
(3 TOTAL, 1 PER SECTOR)
—(E) VERIZON ANTENNA
COMMSCOPE — NHH-6513—R2B
(3 TOTAL, 1 PER SECTOR)
NEW VERIZON ANTENNA
(3) COMMSCOPE — NHHSS-65B—R2B
(3 TOTAL, 1 PER SECTOR)
NEW VERIZON RRH
ERICSSON — RADIO 4408
(3 TOTAL, 1 PER SECTOR)
(E) VERIZON ANTENNA
ERICSSON — AIR 5331
(3 TOTAL, 1 PER SECTOR)
verizon%'
3245 158TH AVENUE MS 231
BELLEVUE, WA 98008
CROWN
CASTLE
1505 WESTLAb�E AVENUE NORTH, SUITE 800
SEATTLE, WA 98109
TOWER ENGINEERING PROFESSIONALS
4710 E ELWOOD ST, STE 9
PHOENIX, AZ 85040
OFFICE: (480) 285-0036
www.tepgroup.net
VERIZON SITE NUMBER:
167122
BU #: 822731
BOISE_CALL_CENTER
2100 S SILVERSTONE WAY
MERIDIAN, ID 83642
EXISTING 110'-0" MONOPOLE I
14
ISSUED FOR:
REV
DATE
DRWN
DESCRIPTION
DES./QA
0
01/19/22
ORG
CONSTRUCTION
IIYL'VI
U 1119122
Graham N1. Andres, P.E.
Professional Engineer License: #15814
1T IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER TI IIS DOCUMENT.
SHEET NUMBER: REVISION:
C-3 0
No Text
APPROVED
.-- 05M7,22
0
00
FRONT
0
ro
SIDE
TOP
ro
PROPOSED COMMSCOPE
— NHHSS-65C—R2B
(TYP OF 3)
COMMSCOPE — NHHSS-65C—R2B
I SCALE: NOT TO SCALE
;_�e
RADIO POLE
MOUNTING
BRACKET (TYP)
PROPOSED LESSEE
RADIO. SEE THIS
SHEET FOR DETAILS.
PROPOSED ANTENNA.
SEE THIS SHEET
FOR DETAILS.
MOUNT PIPE
PROPOSED MOUNTING
BRACKET SUPPLIED
W/ ANTENNA (TYP)-
EXISTING/PROPOSED
MOUNT PIPE
4 EQUIPMENT MOUNTING DETAIL
SCALE: NOT TO SCALE
ANTENNA
FRONT
SIDE
TOP
N
1 1 " PROPOSED ERICSSON — AIR6449
B77 (TYP OF 3)
�-� ERICSSON — AIR6449
L SCALE: NOT TO SCALE
5 NOT USED
SCALE: NOT TO SCALE
FRONT
ro
SIDE
(z� ERICSSON / RADIO 4408
�SCALE: NOT TO SCALE
6 NOT USED
SCALE: NOT TO SCALE
TOP
PROPOSED RRUS 4408
1 (TYP OF 3)
verizon%'
3245 158TH AVENUE MS 231
BELLEVUE, WA 98008
CROWN
CASTLE
1505 WESTLAKE AVENUE NORTH, SUITE 800
SEATTLE, WA 98109
TOWER ENGINEERING PROFESSIONALS
4710 E ELWOOD ST, STE 9
PHOENIX, AZ 85040
OFFICE: (480) 285-0036
www.tepgroup.net
VERIZON SITE NUMBER:
167122
BU #: 822731
BOISE_CALL_CENTER
2100 S SILVERSTONE WAY
MERIDIAN, ID 83642
EXISTING 110'-0" MONOPOLE
14
ISSUED FOR:
REV
DATE
DRWN
DESCRIPTION
DES./QA
0
01/19/22
ORG
CONSTRUCTION
IIILM
01/19/22
Graham M. Andres, P.E.
Professional Engineer License: #15814
IT IS A VIOLATION OE LAW FOR ANY PERSON,
UNLESS TI IEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTERTIIIS DOCUMENT.
SHEET NUMBER: REVISION:
C-5 0
DERIDIAN
APPROVED
O511],22
`3ertci.4
aM AIR6449 AIR5331
x x x x x x x Y,
X x x X x X X x x FD-
x FD-A11MO x x x X X X x MIMO
x x x x X x x x
m �,.,
a:
RM1!
coax/port colors
�700/850�
�850�
700
PCs
-AWS1/3�
CBRS
Sector B
certr.l C:
_ AIR6449 AlR5331 =AIR6449
x x x x X x x X
X x K X X X x x
X X x x x X x x x x K x X X x x
x F= ;11'v'O x x x x x X7--
V A9 : x FD Pd11P 1 x x K x X X x x
X. x x X x x X X x x K x X X x
In uio u
CNS"U
y* ew I I T -s7 I I I
,� LE: NOT TOPLUMBING DIAGRAM
SCASCALE
L
TOWEW
AIR5331
FD-
1vi I mo
' J
verizon
3245 158TH AVENUE MS 231
BELLEVUE, WA 98008
CROWN
(-.�ASTLE
1505 WESTLAKE AVENUE NORTH, SUITE 800
SEATTLE, WA 98109
'-4�
TOWER ENGINEERING PROFESSIONALS
4710 E ELWOOD ST, STE 9
PHOENIX, AZ 85040
OFFICE: (480) 285-0036
www.tepgroup.net
VERIZON SITE NUMBER:
167122
BU #: 822731
BOISE_CALL_CENTER
2100 S SILVERSTONE WAY
MERIDIAN, ID 83642
EXISTING 110'-0" MONOPOLE I
IN
ISSUED FOR:
REV
DATE
DR"
DESCRIPTION
DES./Q
0
01/19/22
ORG
CONSTRUCTION
HAM
01/19/22
Graham M. Andres, P.E.
Professional Engineer License: #15814
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER REVISION:
C-6 0
APPROVED
.__ 05M7,22
TO ANTENNA COAX
COPPER/GALVANIZED GROUND BAR
• o • oT • f • • • • • • • • • • • • • •
• 0 • i • 0 • • • • • • • • • • • • • •
TWO HOLE LONG BARREL
COMPRESSION LUG (TYP)
NOTES:
1. DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED.
2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS.
3. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO ANTENNA MOUNT STEEL.
ANTENNA SECTOR GROUND BAR DETAIL
SCALE: NOT TO SCALE
TO TOWER MOUNTED EQUIPMENT
(TYP)
TO ANTENNA MONOPOLE
Al
r
ANTENNA GROUND BAR
LOCATED AT MCL
(BONDED TO TOWER STEEL)
STANDARD COAX %
2 HOLE LUG (TYP)
CABLE GROUND KIT /
(TYP)
#6 STRANDED CU WIRE WITH
GREEN, 600V, THWN
INSULATION (OR AS PROVIDED
WITH GROUND KIT) (TYP)
TO ANTENNA COAX
COPPER/GALVANIZED GROUND BAR
a ao�o�00000000000000
a0o0o00000000000000
�00000000000000000 Oo
TWO HOLE LONG BARREL COMPRESSION LUG
(TYP)
#2 SOLID TINNED COPPER
CONDUCTOR TO TOWER/SHELTER
GROUND RING (2 TYP. FOR
BOTTOM GROUND BAR ONLY)
NOTES:
1. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS.
2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY).
3. GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER.
TOWER/SHELTER GROUND BAR DETAIL
SCALE: NOT TO SCALE
2-HOLE CRIMP/
COMPRESSION
CONNECTOR
QTAINL— STEEL BOLT
TYP)
STAINLESS STEEL
FLAT WASHER
(TYP)
] GROUND
BAR
STAINLESS STEEL
FLAT WASHER
STAINLESS STEEL `\ (TYP)
BELLVILLE WASHER STAINLESS STEEL NUT
(TYP) (TYP)
SINGLE CONNECTOR AT GROUND BARS
STAINLESS STEEL BOLT
MECHANICAL CONNECTION
(TYP)
STAINLESS STEEL
FLAT WASHER
COAX GROUND BAR WITH
COAX CABLE INSULATORS, CONNECTED
(TYP FOR ALL) DIRECTLY TO THE BOTTOM
DRAGON TOOTH WASHER
OF MONOPOLE. SEE NOTE 1.
(TYP)
STEEL
TO BTS EQUIPMENT VIA -- ---
2/0 TINNED BARE
COPPER WIRE
TRAY OR ICE BRIDGE I I
2-HOLE CRIMP/
MONOPOLE PIER
COMPRESSION
STAINLESS STEEL
FLAT WASHER
i�
CONNECTOR
, GROUND WIRE
(TYP)
1 SEE NOTE 3
STAINLESS STEEL /
STAINLESS STEEL NUT
GROUND WIRE
NOTE 3 �_
BELLVILLE WASHER
(TYP)
(TYP)
- -----� i-��
SINGLE CONNECTOR
AT STEEL OBJECTS
INSPECTION WELL EXOTHERMIC WELD (TYP)
NOTES:
STAINLESS STEEL
SELF -DRILLING
STAINLESS STEEL
1. NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA
METAL SCREW
FLAT WASHER
LOCATIONS AND CONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE
(TYP)
(TYP)
TOWER SHALL HAVE GROUND KITS AT THE MIDPOINT. PROVIDE AS REQUIRED.
1
2. ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC.
2-HOLE CRIMP/
TOWERS. ALL MECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI -OXIDANT COATING.
COMPRESSION
CONNECTOR
3. ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE
RECOGNIZED EDITION OF ANSI/TIA 222 AND NFPA 780.
DRAGON TOOTH
METALLIC OBJECT
WASHER
(TYP)
SINGLE CONNECTOR AT
METALLIC/STEEL OBJECTS
TYPICAL ANTENNA CABLE GROUNDING
FOR
EXTERIORCONNECTIONS
(�)S1CARDWAFR10FTDFTAS1L
4
SCALE: NOT TOSCALE
ALE: NTO CALE
8" PVC PLUG
8" PVC PLUG CPLG. (THRD.)
T/FINISH GRADE
00
SUBGRADE
w
o #2 SOLID (TEST LOOP)
z
z o NOTCH SIDES OF 8" PVC SCH 40 PIPE
TO ALLOW EXIT/ENTRANCE OF
o EXOTHERMIC WELD GROUND RING WIRE
w
III —III— III1 ��I I—
TRENCH BOTTOM
/ 2/0 TINNED CU EXTERNAL
CADWELD TEST LOOP TO TOWER GROUND RING WIRE
GROUND RING WIRE
NOTES: 5/8" 0 x 10'-0" LONG COPPER CLAD GROUND ROD
1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE
VERTICAL
2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE.
(WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D)
M
(
INSPECTION WELL DETAIL
SCALE: NOT TO SCALE
6" WIDE METALLIC HTEL
GRADE WARNING/LOCATOR TAPE AT
12" DEPTH
0 0 0 ��-
LAVIr1LM1V1. VVLLU
I
1 1
GROUND RING #2 COPPER WIRE
SOLID, TINNED FOR CARRIER AND ICE
BRIDGE GROUND LOOP
GROUND RING 2/0 FOR
TOWER GROUND LOOP
GROUND ROD COPPER
CLAD STEEL ROD W/MIN.
5/8 0 x 10'-0" LONG
NOTES:
1. GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE
VERTICAL
2. GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE.
(WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D)
GROUND ROD DETAIL
SCALE: NOT TO SCALE
verizon%l
3245 158TH AVENUE MS 231
BELLEVUE, WA 98008
CROWN
CASTLE
1505 WESTLAKE AVENUE NORTH, SUITE 800
SEATTLE, WA 98109
TOWER ENGINEERING PROFESSIONALS
4710 E ELWOOD ST, STE 9
PHOENIX, AZ 85040
OFFICE: (480) 285-0036
www.tepgroup.net
VERIZON SITE NUMBER:
167122
BU #: 822731
BOISE_CALL_CENTER
2100 S SILVERSTONE WAY
MERIDIAN, ID 83642
EXISTING 11W-0" MONOPOLE
14
ISSUED FOR:
REV
DATE
DRWN
DESCRIPTION
DES./QA
0
01/19/22
ORG
CONSTRUCTION
IIYL'VI
01/19/22
Graham M. Andres, P.E.
Professional Engineer License: #15814
1T IS A VIOLATION OP LAW FOR ANY PERSON,
UNLESS TIIEY ARE ACTING UNDER TIIE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER TI IIS DOCUMENT.
SHEET NUMBER:
REVISION:
G-1
0 11
N -
APPROVED o WIRE SIZE BURNDY LUG BOLT SIZE
o5, ,z2 J
`,I,I R4LL1 #6 AWG GREEN INSULATED YA6C-2TC38 3/8" - 16 NO S 2 BOLT verizon
TYPE HS TYPE 2-YA-2 TYPE XA TYPE YA-2 TYPE GY #2 AWG SOLID TINNED YA3C-2TC38 3/81, - 16 NO S 2 BOLT
#2 AWG STRANDED YA2C-2TC38 3/8', - 16 NO S 2 BOLT 3245 158TH AVENUE NIS 231
BELLEVUE, WA 98008
V #2/0 AWG STRANDED YA26-2TC38 3/8" - 16 NO S 2 BOLT
#4/0 AWG STRANDED YA28-2N 1/2" - 16 NO S 2 BOLT
TYPE W TYPE VN TYPE NO TYPE SS TYPE GR BURNDY GROUND LUG W/ — -HEAT SHRINK CROWN
LONG BARREL
(SEE CHART) (CLEAR) CASTLE
NUT _ GROUNDING
(TYP) A CONDUCTOR 1505 WESTLAb�E AVENUE NORTH, SUITE 800
LOCK WASHER- / SEATTLE, WA 98109
(TYP)
TYPE VS TYPE VB TYPE PT TYPE GT'
1
NOTE: \ GROUND BAR 1 BOLT
1. ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC -(SEE CHART)
MOLDS TO BE USED FOR THIS PROJECT. (TYP)
2. MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD.
BURNDY TWO HOLE LUG W/
O LONG BARREL
(SEE CHART) TOWER ENGINEERING PROFESSIONALS
(DCADWELD GROUNDING CONNECTIONS 4710 E ELWOOD ST, STE 9
I BARE WIRE TO BE PHOENIX, AZ 85040
SCALE: NOT TO SCALE No—ox AT BOTH ENDS OFFICE: (480) 285-0036
www.tepgroup.net
STRANDED (GREEN INSULATED) ONLY FOR #6 AWG IN
TO ANTENNAS (SEE CHART)
WEATHERPROOFING KIT
(SEE NOTE 3) (TYPICALLY)
ANTENNA CABLE _ 12" TO 24" VERIZON SITE NUMBER:
120" MAX. RX2 TX1/RX1 WEATHERPROOFING
KIT
(TYP) NOTES: 167122
GROUND KIT 1. ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
' I COAX JUMPER (TYP.) (TYP) ALL HARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL BU #: 822731
HARDWARE ARE TO BE AS FOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, �+
FLAT WASHER AND NUT. BOISE CALL CEN -ENTER
coNNEcroR #6 AWG MECHANICAL LUG CONNECTION
x WEATHERPROOFING KIT �T
#6 AWG STRANDED COPPER GROUND WIRE �� (TYP. SEE NOTE 2)
(GROUNDED TO GROUND BAR). SEE NOTE 1 & 2 COPPER/GALVANIZED SCALE: NOT TO SCALE 2101/nn ��r� S SILVERSTONE WAY
1
p2 N / COAX
BONDEDROUND D RECTLLYRTOWER MERIDIAN, ID OJ642
CABLE GROUND KIT
i
/ CABLE CONNECTOR ANTENNA CABLES �� #6 AWG MIN. FROM ANTENNA_ EXISTING 1101-011 MONOPOLE
TO BTS EQUIPMENT (TYP.) CABLE GROUND KIT
NOTES: ( A
1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND
WIRE DOWN TO GROUND BAR.
NOTES:
2. GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR
RECOMMENDED BY CABLE MANUFACTURER. 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND
WIRE DOWN TO ANTENNA GROUND BAR.
GROUND BAR ON SHELTER. ICE
3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT
BRIDGE, OR ON ANTENNA TOWER
BE USED. 2. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE
USED.
GROUND KIT CONNECTION
�� DO DO � 0 O
(�)CABLE
ESCM
SCALE: NOT TO SCALE
OO0 S
GROUND CABLE CONNECTION
O
O
, ,
14
ISSUED FOR:
REV
DATE.
DRWN
DESCRIPTION
DES./( A
0
01/19/22
ORG
CONSTRUCTION
IIYL'VI
7 SCALE: NOT TO SCALE
0 *TWO HOLE LUG, OR GROUNDING SHALL BE
3/8-1 1 xl" TAMPER EXOTHERMIC WELD TO BE USED ELIMINATED WHEN GROUND BAR
RESISTANT BOLT WITH #2 AWG BARE CONDUCTOR IS ELECTRICALLY BONDED TO
(TYP) WIRE TO BUILDING SERVICE METAL TOWER
INSULATORS T, , GROUND OR GROUND RING
SEE NOTE 2.
(TYP)
® �� GROUNDWIRE INSTALLATION
WALL BRACKET
®
(TYP) �� ® ® NOTE: MINIMUM OF S/S NUT SCALE: NOT TO SCALE
® ® 3 THREADS TO BE (TYp)
VISIBLE
0 ® ® (TYP)
® ® ` SPLIT
WAS
® / wasHER
®\ 2 HOLE LONG (TYp) #2 TINNED SOLID IN 3/4" LIQUID TIGHT PIPE
BARREL TINNED UNIVERSAL COPPER CONDUIT FROM 24" BELOW GRADE TO
SOLID COPPER
WITHIN 3" TO 6" OF CAD -WELD
® GROUND BAR (4"x20") LUG S/S FLAT
LOCK WASHER (TYP) / WASHER TERMINATION POINT. EXPOSED END OF 01/19/22
THE LIQUID TIGHT CONDUIT MUST BE
P/N MID (nP) SEALED WITH SILICONE CAULK.
(TYR)
TWO -HOLE CADWELD
COMPRESSION LUG TIN COATED SOLID
COPPER BUS BAR S/S(TYR) GrahamN1Andres, P.L.
NOTES: WAS E R ( Professional Engineer License: #15814
WASHER
1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE CHERRY INSULATOR (TYP) 1T IS A VIOLATION OP LAW FOR ANY PERSON,
USA INC. TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO INSTALLED IF REQUIRED UNLESS TIIEYARE ACTING UNNDERTIIEDIRECTION
MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, S/S BOLT TIE INTO EXISTING GROUND RING OF A LICENSED PROFESSIONAL ENGINEER,
CAD -WELDING ON THE TOWER AND/OR IN THE AIR ARE NOT PERMITTED. (TYP) TO ALTER TI IIS DOCUMENT.
2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEEL
USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. SHEET NUMBER: REVISION:
6 GROUND BAR DETAIL 7 LUG DETAIL 8 TRANSITIONING GROUND DETAIL G-2
O
SCALE. NOT TO SCALE SCALE. NOT TO SCALE SCALE. NOT TO SCALE