HomeMy WebLinkAbout11_6PLEX w Garage_1st Floor Plan V1aERIDIANy-
APPROVED
ugh ovas�zz
FU
I I T
A-3.0
1
4 5 6 7
188' - 0"
I 24' - 6" I 45' - 0" I 45' - 0" I 24' - 6" I 24' - 6" I 24' - 6" I
FIRST FLOOR PLAN
1 1 /8" = -0"
KEYNOTES - FLOOR PLAN
#
NOTE
2.1
MULTIPLE WINDOWS FRAMED VERTICALLY- REFER TO
ELEVATIONS AND WINDOW TYPES.
2X6 WOOD FRAMING, CAVITY
FILLED W/ R-21 BATT INSULATION
"HARDI" SIDING (OR CEMENTITIOUS
EQ.) o/ TYVEK (OR OTHER APPROVED
EQ.) o/ min. 7/16" WALL SHEATHING -
REFER TO ELEVATIONS FOR
EXTERIOR FINISH TYPE
5/8" GYP @ INTERIOR LOCATIONS
(TYPE "X" TYP., NOT REQUIRED AT
NON RATED LOCATIONS)
W7 1-HR RATED EXTERIOR WALL
NOTE: FIRE RATED WALL PER UL U356 ALL
PENETRATIONS MUST BE FIRE CAULKED OR
OTHERWISE PROTECTED
2X6 WOOD FRAMING
5/8" GYP. B.D EA. SIDE PRIME
PAINT & FINISH, EACH SIDE.
ACOUSTIC BATT
INSULATION
W3 STANDARD 2X6 WALL
y.. 2X4 WOOD FRAMING
r
(2) LAYERS 5/8" GYP. B.D EA. SIDE
OF STUDS
r
ACOUSTIC BATT
h INSULATION
rt
r
W6 STANDARD SEPARATION WALL -
EXTERIOR
NOTE: FIRE RATED WALL PER GA FILE NO WP 3820.
ALL PENETRATIONS MUST BE FIRE CAULKED OR
OTHERWISE PROTECTED
2X4 WOOD FRAMING
5/8" GYP. B.D EA. SIDE PRIME,
PAINT & FINISH, EACH SIDE.
ACOUSTIC BATT
INSULATION
W2 STANDARD 2X4 WALL
1"
2X4 WOOD FRAMING
(2) LAYERS TYPE "X" 5/8" GYP. B.D
EA. SIDE OF STUDS PRIME, PAINT
& FINISH INT. SIDE.
ACOUSTIC BATT
INSULATION
W5 STANDARD SEPARATION WALL
NOTE: FIRE RATED WALL PER GA FILE NO WP 3820.
ALL PENETRATIONS MUST BE FIRE CAULKED OR
OTHERWISE PROTECTED
2
A-3.0
2X6 WOOD FRAMING, CAVITY
FILLED W/ R-21 BATT INSULATION
"HARDI" SIDING (OR CEMENTITIOUS
EQ.) o/ TYVEK (OR OTHER APPROVED
EQ.) o/ WALL SHEATHING - REFER TO
ELEVATIONS FOR EXTERIOR FINISH
TYPE
5/8" GYP @INTERIOR LOCATIONS
(TYPE "X" TYP., NOT REQUIRED AT
ff�_ NON RATED LOCATIONS)
W1 STANDARD EXTERIOR WALL
2X6 WOOD FRAMING
5/8" GYP. B.D EA. SIDE PRIME,
PAINT & FINISH, EACH SIDE.
ACOUSTIC BATT
INSULATION
W4 GARAGE 2X6 WALL
NOTE: FIRE RATED WALL PER GA FILE NO WP 3510.
ALL PENETRATIONS MUST BE FIRE CAULKED OR
OTHERWISE PROTECTED
Ed
GENERAL NOTES:
A. VERIFY ALL DIMENSIONS IN FIELD AND NOTIFY ARCHITECT OF DISCREPANCIES
PRIOR TO FABRICATION OR INSTALLATION
B. TYPICAL DIMENSION LOCATIONS ARE TO F.O. CONCRETE OR GRID LINES OR
LEFT/TOP SIDE OF F.O. STUD, U.N.O. (TO F.O. STRUCTURAL MEMBERS, NOT TO
F.O. FINISH MATERIALS
C. PROVIDE SOLID BLOCKING IN WALLS FOR ITEMS SUCH AS GRAB BARS, TOILET
PARTITIONS, PAPER DISPENSERS, WALL -HUNG TOILETS, AND ETC.
D. ALL STUD FRAMED INTERIOR PARTITIONS WALLS SHALL BE BRACED TO THE
UNDERSIDE OF DECK/STRUCTURE ABOVE
E. CONTRACTORS SHALL ADHERE TO ALL CODES, RULES AND REGULATIONS FOR
IBC AND SPECIFIC TRADE CODES
F. DO NOT SCALE DRAWINGS
G. LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS
U.N.O.
H. ALL EXPOSED GWB EDGES TO HAVE METAL EDGE TRIM, TYP.
I. LIGHTER LINES TYPICALLY INDICATE OWNER SUPPLIED ITEMS U.N.O.
J. ALL NOTES AND COMPONENTS TO BE CONSIDERED " OR EQUIVALENT" AS LONG
AS INTENT/QUALITY OF THE DESIGN IS MAINTAINED.
K. ANY NOTES STATED HEREIN SHALL BE SUPERCEDED BY NOTES PROVIDED IN
STRUCTURAL, MEP DRAWINGS (WHICH WILL TAKE HIGHER PRIORITY).
L. GRADES AT ENTRY DOORS TO BE NO MORE THAN 1.5 % IN ALL DIRECTIONS FOR
A MINIMUM DISTANCE OF 5' - O" PERPENDICULAR TO DOORS
FOUNDATIONS
A. PLACE ALL REINFORCING AS PER A.C.I. CODES AND STANDARDS
B. WATERPROOF BASEMENT/STEM WALLS BEFORE BACKFILLING.
C. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE
TREATED, REDWOOD OR PROTECTED WITH 55# FELT.
D. MUDSILLS TO BE 2 x PRESSURE TREATED WOOD OR REDWOOD.
E. 2" RIGID INSULATION TO BE ATTACHED TO FOUNDATION
PERIMETER WALLS.
FRAMING
A. UNLESS OTHERWISE NOTED ON PLANS, ALL EXTERIOR WINDOW AND
DOOR HEADERS ARE TO BE SIZED PER ENGINEER.
B. SOIL BEARING PRESSURE IS ASSUMED TO BE 1500 P.S.F. IF THIS VARIES,
CONTACT ARCHITECT PRIOR TO CONSTRUCTION.
C. NAILING SCHEDULE AS PER TABLE 25-0 I.B.C. TYPICAL PLYWOOD
NAILING WITH 8D NAILS @ 6" O.C. AT EDGES AND 12" O.C. ON INTERIOR.
D. WOOD FRAMING MEMBER GRADES ARE AS FOLLOWS UNLESS OTHERWISE NOTED ON THE PLANS:
POSTS, BEAMS, HEADERS, JOISTS & RAFTERS: NO. 2 & BETTER KD DOUGLAS FIR -LARCH
PLATES, BLOCKING & BRIDGING, ETC.: NO. 3 & BETTER KD DOUGLAS FIR -LARCH
STUDS: STUD GRADE KD DOUGLAS FIR -LARCH
POST & BEAM DECKING: UTILITY GRADE DOUGLAS FIR
PLY SHEATHING: CD DOUGLAS FIR PLY 7/16"
INSULATION
A. ALL EXPOSED INSULATION TO HAVE AFLAME SPREAD RATING OF LESS THAN 25 AND A SMOKE
DENSITY OF LESS THAN 450
Z+)
ARCHITECTURE
DESIGNS PLUS, P.A.
PROFESSIONAL SEAL
All
c�+n wnu�e
swewmvm
� o
I d
V 1
o3
0. �f
� o a
N
W W q 0000
W �qA
� O
(10
ILL]
I..L
J
O J
CN O
Q �
J
co LL
(o 0
O Q
Z LL
i
u w
Z W i
WQ O w
a
0
JOB NO: 20185
DATE:
DRAWN BY: BPB
SHEET NUMBER:
A-2.0
PLOT DATE:
2/25/2022 4:45:33 PM
w
0
z
O
rn
K
Mc-j
COPYRIGHT ALL RIGHTS RESERVED. THIS DRAWING AND ALL INFO. CONTAINED HEREIN, IS THE PROPERTY OF ARCHITECTURE DESIGNS PLUS P.A., AND MAY NOT BE REUSED WITHOUT THE WRITTEN PERMISSION OF THE ARCHITECT