Loading...
HomeMy WebLinkAboutConstruction Drawings C2.20 V1APPROVED 05/Da22 _..vna:a•o OR qS WOVEN WIRE FENCE (MIN. 14-1/2 GAUGE, 50' MIN DICTgD _ MAX. 6•' MESH SPACING) EXISTING BY LppAl REQUIREM,�• PAVEMENT �5:1 yvell 6' MIN. f O O°a e D o oe00000 A MOUNTABLE BEAM 'S OPTIONAL �• M/ PROFILE `LA N• Q OVERLAP GEOTEXTILE AND/OR WOVEN EXISTING Z COMPACTED BACKFILL WIRE FENCE ACROSS TWO STAKES GROUND O WHEN NECESSARY TO CONTINUE a FENCE � 5 F 18 50' MIN o U m INC HES(AIA CI (MN) SECURELY FASTEN FENCE MATERIAL °o °o v — m TO BOTH STAKES WITH TIES OR ° 0 0 0 0 e ° o III—�I OTHER FASTENERS o° oe ;�� 10• EXISTING4;' w F II—���j1��� III,. o°i o IN oo`eg AVEMENT o A _ ° - o 0 0 0 0 0 0 0 0 3:1 SLOPE TO MATCH _ ,vo?, Po GRADE. TYP. TO INSIDE a —I i (— ELEVATION AND OUTSIDE SLOPE. COMPACTED BACKFILL STANDARD -N�n SYMBOL :::°:o=='=*^ ; PLAN VIEW WOVEN WIRE FENCE (MIN. 14 1/2 GAUGE, POSTS: STEEL EITHER T OR U TYPE. MAX. 6" MESH SPACING) WITH GEOTEXTILE COVER �' } _ FENCE: WOVEN WIRE, 14-1/2 GA. 6" MAX m MESH OPENING N Lm FABRIC: 1. AMOCO 1198 N �\NE U 0 2. BELTECH 810 a o 3. MIRAFI 130X GRO NOTES: 27, 1' IN O ppMMEpAq� EE 4. LING GTF 190 FINISH GRADE CBACKFILLD 5. SI 915 SC 1. STONE SIZE -USE 2" STONE OR RECLAIMED OR RECYCLED CONCRETE EQUIVALENT. 2. LENGTH -AS REQUIRED, BUT NOT LESS THAN 50 FEET (EXCEPT ON A SINGLE RESIDENCE LOT WHERE A 30 I � MIN. MIN. + d z FOOT MINIMUM LENGTH WOULD APPLY). I, FLOW ELEVATION 3. THICKNESS -NOT LESS THAN 6 INCHES. 4. WIDTH-10 FOOT MINIMUM, BUT NOT LESS THAN THE FULL WIDTH AT POINTS WHERE INGRESS OR EGRESS o io OCCURS. 5. FILTER CLOTH -WILL BE PLACED OVER THE ENTIRE AREA PRIOR TO PLACING OF STONE. FILTER WILL NOT BE IMPERVIOUS LINER 3' MIN. DEPTH COMPACTED SOIL UNDISTURBED EXTEND `WIRE FENCE A REQUIRED ON A SINGLE FAMILY RESIDENCE LOT. BERM ai .o GROUND MIN. OF 2' INTO TRENCH 6. SURFACE WATER -ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE 00 v PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL. A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE 6' X 6" TRENCW ' EMBEDDED GEOTEXTILE FABRIC \ PERMITTED. 7. MAINTENANCE -THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OF SECTION A -A \� MIN. 6" INTO GROUND W/ 6" LAID ALONG BOTTOM FLOWING OF SEDIMENT ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ICU=' W5 A -A -SECTION OF TRENCH ADDITIONAL STONE AS CONDITIONS DEMAND AND REPAIR AND OR CLEANOUTS OF ANY MEASURES USED TO / TRAP SEDIMENT. ALL SEDIMENT SPILLED PROPPED. WASHED OR TRACKED ONTO PUBLIC RIGHTS -OF -WAY MUST NOTES � 1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES. BE REMOVED IMMEDIATELY. 8. WASHING -WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTRANCE ONTO PUBLIC 1. IMPERVIOUS LINER SHOULD BE A MINIMUM OF 10 MIL POLYETHYLENE in 2. GEOTEXTILE TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY RIGHT-OF-WAY. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITH STONE AND SHEETING AND SHOULD BE FREE OF HOLES, TEARS, OR OTHER DEFECTS THAT COMPROMISE 0 24 AT TOP AND MID SECTION. WHICH DRAINS INTO APPROVED SEDIMENT TRAPPING DEVICE. THE IMPERMEABILITY OF THE MATERIAL. - 3. WHEN TWO SECTIONS OF GEOTEXTILE ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY SIX INCHES AND FOLDED. 9. PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. m 4. MAINTENANCE SHALL BE PERFORMEQ AS NOTED IN THE EROSION CONTROL PLAN. COLLECTED MATERIAL 0 SHALL BE REMOVED WHEN BULGES' DEVELOP IN THE SILT FENCE. m 5. ALL SILT FENCE SHALL INCLUDE WIRE SUPPORT UNLESS INDICATED OTHERWISE E 3 SEDIMENTATION/SILT FENCE WITH WIRE SUPPORT SCALE: NTS 2 SILT FENCE OVERLAP DETAIL SCALE: NTS 3 VEHICLE TRACKING CONTROL SCALE: NTS 4 CONCRETE WASHOUT DETAIL SCALE: NTS ^ L/ DANDY SACK TM STORM SEWER �� O GRATE 000000�0000�0 00 00 00 00 00000�00 LIFT 00 STRAPS INFORCED CORNER OPTIONAL OVERFLOW PORT It MANAGEABLE 2 FOOT CONTAINMENT AREA DUMPING STRAPS STORM INLET S DETAIL OF INLET SEDIMENT CONTROL DEVICE PROJECT: DR.BY: CITY/STATE: DATE: I DR. NO: J CY) N Q r^ LU v W co C0 00 Lw O (n O z ELI (n ILL > Of Z 0 LU ILL m 2 O J=)E U U LLU) LL Z L= W O �v_> V) Q O �o LU N O 04 O 04 O Z 7 7 04 7 O (h (h (h DO DO LU Q U 2 In ¢ DO O o m co 00 Z W m LU F LU Z> 0 y CD m ¢ DANDY SACK- ¢ In LU LU O 0 ❑ E CL SPECIFICATIONS NOTE: THE DANDY SFCK` WILL E MANUFACTUREDRI U.S.A. FROM A WOKEN 0 o c> a SEAL _ � � MONOFILAMENT FABRIC THAT MEETS OR EXCEEDS EDS THE HE FOLLOWING SPECIFICATIONS: REGULAR ROW DANDY SACK"' (BLACK) N LL Mechanical Propertlee Test Melh°d 7 _ } a Grab Tensile Strength ASTM D4632 G•abTa"suaek" 1- AB71AD4632 ENr, re R1r g,h ABTM D 4833 g5\ ENS ENS "•a1 Slre"gm ABTM D 3786 ok ?' �(n w rsp ear SIe gth ABTM D 4533 OUV _ Resistance ABTM D4355 en, Opening Rl ABTM D4)51 ABTM D 4491 /m (gal/min/H) 8670 m a Y a ABTM D 4491 0 HI—FLOWND DAY SACK"'' (SAFETY ORANGE) Mechancal Properties Test Method In 03/09/2022r0 '9T pP P OF \ ,9 � ejGA ¢ o t IL HP� % 3 N U o ❑ — v m /m (gal/ml"/H) SHEET n� E *Note: All Dandy Sacks TM' can be ordered with our optional oil absorbent pillows /'\ /'� -,6 ❑ D5 L L O . DROP INLET PROTECTION DETAIL SCALE: NTS 6 NOT USED SCALE: NTS 7 NOT USED SCALE: NTS 8 NOT USED SCALE: NTS