Loading...
HomeMy WebLinkAboutConstruction Drawings - C2.30 V1APPROVED DsAoa22 _..vna:aro 0111 R qS WOVEN WIRE FENCE (MIN. 14-1/2 GAUGE, D/CTgTED 50' MIN By - MAX. 6" MESH SPACING) LOC R1REQUIREM,,JJJJ���� EXISTING PAVEMENT GryTS + 3' _ 51 "ny 6' MIN.° A O O°O o 0 0 MOUNTABLE BEAM OPTIONAL M/ PROFILEAe Q OVERLAP GEOTEXTILE AND/OR WOVEN EXISTING z COMPACTED BACKFILL WIRE FENCE ACROSS TWO STAKES GROUND O WHEN NECESSARY TO CONTINUE a FENCE � 185 FEET (MAX) 50' MIN o U U) /NCHES (MIN) SECURELY FASTEN FENCE MATERIAL TO BOTH STAKES WITH TIES OR 0 e °o °o 2`3° o 0 0 0 0 0 0 0 •° e�°F� OTHER FASTENERS o o b 0` �� •�°ae 10' EXISTING eve �� IN AVEMENT o A qp e 00000Bo 00 0 0 ,e d:o�, 3:1 SLOPE TO MATCH GRADE. TYP. TO INSIDE AND OUTSIDE SLOPE. ELEVATION °obi q a COMPACTED BACKFILL STANDARD — g as°''�' """� SYMBOL N. PLAN VIEW°. WOVEN WIRE FENCE (MIN. 14 1/2 GAUGE, POSTS: STEEL EITHER T OR U TYPE. MAX. 6" MESH SPACING) WITH GEOTEXTILE COVER .'? FENCE: WOVEN WIRE, 14-1/2 GA. 6" MAX MESH OPENING V \NE FABRIC: 1. AMOCO 1198 N V O 2. BELTECH 810 o 3. MIRAFI 130X ��Q`� GRO y NOTES' 27 1' N O a 4. LING GTF 190 ppMMppqq�� EE 5. SI 915 SC FINISH GRADE CBACKFILLD 1. STONE SIZE -USE 2" STONE OR RECLAIMED OR RECYCLED CONCRETE EQUIVALENT. 2. LENGTH -AS REQUIRED, BUT NOT LESS THAN 50 FEET (EXCEPT ON A SINGLE RESIDENCE LOT WHERE A 30 3' MIN. MIN + z F FOOT MINIMUM LENGTH WOULD APPLY). 3. THICKNESS -NOT LESS THAN 6 INCHES. FLOW ELEVATION 4. WIDTH-10 FOOT MINIMUM, BUT NOT LESS THAN THE FULL WIDTH AT POINTS WHERE INGRESS OR EGRESS o OCCURS. 5. 5. FILTER CLOTH -WILL BE PLACED OVER THE ENTIRE AREA PRIOR TO PLACING OF STONE. FILTER WILL NOT IMPERVIOUS LINER 3' MIN. DEPTH COMPACTED SOIL m ❑ `o EXTEND WIRE FENCE A UNDISTURBED�� BE REQUIRED ON A SINGLE FAMILY RESIDENCE LOT. BERM y - MIN. OF 2' INTO TRENCH \ 6. SURFACE WATER -ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE TRENC" EMBEDDED GEOTEXTILE FABRIC \� PIPED ACROSS THE ENTRANCE . IF PIPING IS IMPRACTICAL. A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 7. MAINTENANCE -THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OF SECTION A -A o MIN. 6" INTO GROUND W/ 6" LAID ALONG BOTTOM FLOWING OF SEDIMENT ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH - A -A -SECTION OF TRENCH ADDITIONAL STONE AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUTS OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED PROPPED. WASHED OR TRACKED ONTO PUBLIC RIGHTS -OF -WAY MUST NOTES 1. WOVEN WIRE FENCE TO BE FASTENED SECURELY TO FENCE POSTS WITH WIRE TIES. BE REMOVED IMMEDIATELY. 8. WASHING -WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO ENTRANCE ONTO PUBLIC1. 1. IMPERVIOUS LINER SHOULD BE A MINIMUM OF 10 MIL POLYETHYLENE 2. GEOTEXTILE TO BE FASTENED SECURELY TO WOVEN WIRE FENCE WITH TIES SPACED EVERY RIGHT-OF-WAY. WHEN WASHING IS REQUIRED IT, SHALL BE DONE ON AN AREA STABILIZED WITH STONE AND SHEETING AND SHOULD BE FREE OF HOLES, TEARS, OR OTHER DEFECTS THAT COMPROMISE o E 24 AT TOP AND MID SECTION. WHICH DRAINS INTO APPROVED SEDIMENT TRAPPING DEVICE. THE IMPERMEABILITY OF THE MATERIAL. - 3. WHEN TWO SECTIONS OF GEOTEXTILE ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY SIX INCHES AND FOLDED. 9. PERIODIC INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. .1 m B 4. MAINTENANCE SHALL BE PEVFORMEQ AS NOTED IN THE EROSION CONTROL PLAN. COLLECTED MATERIAL SHALL BE REMOVED WHEN BULGES' DEVELOP IN THE SILT FENCE. 5. ALL SILT FENCE SHALL INCLUDE WIRE SUPPORT UNLESS INDICATED OTHERWISE E 3 SEDIMENTATION/SILT FENCE WITH WIRE SUPPORT SCALE: NTS 2 SILT FENCE OVERLAP DETAIL SCALE: NTS 3 VEHICLE TRACKING CONTROL SCALE: NTS 4 CONCRETE WASHOUT DETAIL SCALE: NTS N a E R 3 E E 3 3 U N F- w W 5 S `o U ; Of z w Oo - ❑ a SO ❑ N r ¢ - W U DANDY SACK TM STORM SEWER�� O GRATE O0000000000 0o Oo Oo 00 00�00�00 LIFT 00 STRAPS INFORCED CORNER OPTIONAL OVERFLOW PORT MANAGEABLE 2 FOOT CONTAINMENT AREA DUMPING STRAPS STORM INLET p DETAIL OF INLET SEDIMENT CONTROL DEVICE PROJECT: DR. BY: CITY/STATE: DATE: I DR. NO: J CV N Q W'IT a0 Q LU O LU O I9 J O (%) O z Lu (n i Z LL EC ILL 0 W O U �::); U `0 U) } �of Z a j< O 0 = v� 0 Q O �O W N N CD N N N CD N N N CD N Z> 0 _ W LU LU Q Q U cc O O m ED O 00 0 DO z 00 00 LU F w CD y O Q ¢ DANDY SACK- Ir W � _ ❑ E SPECIFICATIONS � � � CL Q FL S N NOTE: THE DANDY SACK"' WILL BE MANUPACTUR® Hi THE U.SJL FROM A WOVEN MONOFILAMENT FABRIC THAT MEETS OR EXCEEDS THE FOLLOWING SPECIFICATIONS: REGULAR FLOW DANDY SACK- (BLACK) SEAL y LL Mechanical Properties Test Method r .a ie SIr 1n AST. 11632 G, Ta�s6aEiengaiien AST. oa632 g\ONAL fN CD re AST.O I8 �S / so-engm AST. 03 6 OF V\CENSt-O 4-.w a, Sirengln AST.O a533 (n Ov = m es AST. O a355 ROpening Size AST. O 4 51 AST. O - migai/miNil) AST. o aa91 8670 y oa HI-FLND OW DAY SACK '^'(SAFETY ORANGE) Sr 01/14/2022 �O Mechanical Properties Teat Method f \ QP o OF �B�CA o = IL NA' 1 3 O U t m v _ im \ Y c (gauminin) m SHEET *Note: All Dandy Sacks"' can be ordered with our optional oil absorbent pillows C2.30 o a 5 DROP INLET PROTECTION DETAIL SCALE: NTS ��T USED SCALE: NTS 7 SCALE: NTS NOT USED 8 NOT USED SCALE: NTS