C1.3_Signage and Street Light Plan V1niui_
APPROVED
Know what's below.
Call before you dig
F
NOTE:
WORK CONTAINED WITHIN THESE PLANS
SHALL NOT COMMENCE UNTIL AN
ENCROACHMENT PERMIT AND/OR A
GRADING PERMIT HAS BEEN ISSUED.
DRAWING STATUS:
FOR AGENCY REVIEW MARK BY
ENGINEER
\ \ \ N N/CKORI, wAV \ \
REVISIONS
SEAL -ENGINEER
Q�OF ISTfgF.O
No. 17011
�,
T
M
9y�pFW FF
N�y1`�v
• PLANNING
A BLAINE A. W O M E R • SURVEYING
CIVIL
CIVIL ENGINEERING ENGINEERING
W• PUBLIC WORKS
Boise, ID 83706, 4355 M Emerald Street, Suite 145 • 1-208-593-7555
SEE SHEET
C 1.0
SCALE;
H V;
0 20 40 60
® KEYNOTES
1. INSTALL TYPE 2 STREET LIGHT POLE WITH LUMINAIRE IN ACCORDANCE
WITH THE CITY OF MERIDIAN, DEPARTMENT OF PUBLIC WORKS
IMPROVEMENT STANDARDS FOR STREET LIGHTING, AND THE MOST
CURRENT CITY OF MERIDIAN SUPPLEMENTAL SPECIFICATIONS AND
DRAWINGS TO THE ISPWC. TYPE 2 STREET LIGHT POLES SHALL BE
25' NOMINAL MOUNTING HEIGHT, SQUARE STEEL WITH BRONZE
POLYESTER COATING AND CONFORM TO THE SUPPLEMENTAL
SPECIFICATIONS. LUMINAIRES SHALL BE LED FIXTURES THAT ARE ON
THE APPROVED FIXTURE LIST (SEE APPROVED LED FIXTURE LIST FOR
STREET LIGHTING), OR HAVE BEEN PRE -APPROVED IN WRITING BY
THE CITY'S TRANSPORTATION AND UTILITY COORDINATOR,
2. EXISTING STREET LIGHT.
3. INSTALL 12"x18" "NO PARKING FIRE LANE" SIGN TYPE "D" PER THE
MOST CURRENT EDITION OF THE IFC APPENDIX D, SECTIONS D103.5
AND D103.6.1.
4. INSTALL STREET DESIGNATION SIGN PER CITY OF MERIDIAN
REQUIREMENTS.
5. MAILBOX CLUSTER LOCATION.
SHEET NOTES
A. CONTRACTOR TO VERIFY STREET LIGHT LOCATIONS WITH CITY OF
MERIDIAN AND ACHD PRIOR TO INSTALLATION AND NOTIFY ENGINEER
IF SAFETY HAZARDS OR UTILITY CONFLICTS EXIST.
B. THE MAXIMUM SPACING FOR TYPE II FIXTURES ALONG LOCAL ROADS
(33 FT OR LESS) IS 260'.
C. THE MAXIMUM SPACING FOR TYPE I FIXTURES ALONG 5-LANE
RESIDENTIAL MOBILITY ARTERIALS IS 300' STAGGERED.
D. STREET LIGHTS SHALL BE OWNED/MAINTAINED BY THE CITY OF
MERIDIAN.
E. SERVICE - ALL STREET LIGHTS SHALL HAVE UNDERGROUND
ELECTRICAL SERVICES PROVIDED. SERVICE VOLTAGE SHALL BE 120 OR
240 VOLTS ONLY. CONTRACTOR SHALL DETERMINE CONDUIT SLEEVE
LOCATIONS, SIZES, AND AMOUNT REQUIRED AT ALL UTILITY AND
PAVEMENT CROSSINGS.
F. METERING - CONTRACTOR SHALL COORDINATE METER LOCATIONS WITH
IDAHO POWER AND CITY OF MERIDIAN. WHERE A METERED SYSTEM IS
REQUIRED, NEW DEVELOPMENTS SHALL INSTALL CONDUIT WITH ONE
NO. 10 STRANDED PULL WIRE FROM THE LAST LIGHT ON EACH END
OF THE SYSTEM TO THE ADJACENT PROPERTY LINE ON A STUBBED
STREET, WHERE THE ADJACENT PROPERTY HAS NO EXISTING STREET
LIGHT SYSTEM. THIS WILL ALLOW FOR THE CONTINUATION OF THE
STREET LIGHTS WHEN THE ADJACENT PROPERTY IS DEVELOPED.
SHEET NO,
CITY OF MERIDIAN, ID
C1.3
WOODCREST TOWNHOMES SUBDIVISION
GENERAL IMPROVEMENT PLANS FILE NO.
SIGNAGE AND STREET LIGHT PLAN
N1420004