Loading...
HomeMy WebLinkAboutA2-1 - MAIN FLOOR PLAN V22 a N N N O N w fV N N N I - IVI/111V rL 1/4" = 1'-0" 26'-11" 2'-0" 20' -1 1/2" 2'-0" 26' - 01/2" 34' - 8" 8' - 7" 33, -10" 3'-0••x5•-0" 3'-0"x5•-0" c 5'-6"x10•-0" 5'-6"x10'-0" 4'-0"x6'-6" 4'-0"x6'-6" 8'-0"H.H. 8'-0"H.H. io 10'-0"H.H. x 6'-0••x8'-0" 10'-0"H.H. 8'-0"H.H. 8'-0"H.H. 0 _ VESTIBULE M 0 0 CONSULT y m 0 r LOCKERICH GING ` RESTRQOM ROOM 12'-3 5'-31/2" 9'-21 T 51/2" 8'-7" 7'-91/2" 6'-111/2" 19'-1" io ------ r " D 3._0..x8.-0.. N J]i fV WAITING 3' 0" x 8' 0" N rn 0 FUAFFRESTROOM BREAK ROOM CONSULT ® �I o 0 5'-711 STORAGE 13'-21/2" 5'-0" I � o n m tV T DROP DOWN M M I M I N I I I I I 3'-0"x8'- L3O- c U m " STORAGE �i x8•-0" ap 6•' x 7' - D•• STORAG 3•-U.xB. ' 8-0" H.H. o 0„ ix \xx M � N N II Q 3• o r-------r--- v RECEPTION � c7 _-- CONSULT ® v - -- LU II � STROOM i BUSINESS OF ICE ___ ____� O 12' 31/2" 5'-31/2" \`119'-2" 5'-4" 2'-6" 11'-0" 5'-0" 5'-31/2" 12'-11/2" -=4'-31/2"= 4'-4" � ----13ccl: u F � T____ o S ORAGEo--- U 3,_0„x8•-U•' in U to 3'-0"x8'-0" - -- ----- ii 11 CONSULT o ® o o N <V ol 12'-31/2" 5'-31/2" 0 6'-6" 6'-11" 5'-31/2" 11'-10" (CJ 8'-11" 19'-7" r � o X-RAY � LAB MECHANICAL 3'. 0•• x 4' - 0" STERILIZATION NURSE'S STATION 8' - O" H.H. rz, O3'-0"x8'-0" " \I (V HALF WALL iv N in 3'- PRIVATE 'I BATH c o o � O 6'-10 8'-5" a a 12'-31/212'-31/2" 10'-0" - - a 12'-31/2" 12'-31/2" i7 2'-2' o M LU RECOVERY O H U' V <V (V eD o`f- o O N WW � 3 DOCTOR'S OFFICE 0 0 OPS #4 OPS #3 OPS #2 OPS 5'-0•' 5'-0" T-0" 5'-0" 5'-0" T-o" 8'-0 H.H. 8'-0 H.H. T-0" 5'-0" 5'-0" T-o" 5'-0" 5'-0•• 8. - H.H. 8'-0 H.H. 8'-0 H.H. 8'-0' H.H. T -11 1/2" 13' - 9 1 /2" 12' - 31/2" ol 12' - 31/2' 12' - 31/2" 11' - 2" T - 31 /2" 77' -1' GENERAL NOTES: 1. EXTERIOR WALLS 2x6, INTERIOR WALLS 2x4 UNLESS NOTED. DOUBLE TOP PLATE AND SINGLE BOTTOM PLATE. 2. FIELD VERIFY ALL DIMENSIONS. 3. VERIFY ALL WINDOW AND DOOR HEADER HEIGHTS WITH GENERAL CONTRACTOR. 4. WINDOW AND DOOR HEADERS TO BE 4x8 DF w/ 2X6 TOP AND BOTTOM PLATES UNDER 5'-0" SPAN. USE 4x10 w/ 2x6 TOP AND BOTTOM PLATE AS HEADERS UP TO T-0" SPAN w/ DOUBLE CRIPPLES. ALL LARGER SPAN HEADERS WILL BE CALLED OUT ON PLAN. 5. SHEAR PANELS ARE TO BE 7116" OSB SHEATHING w/ MIN. 6d NAILS OR MIN 1 3/4" GAUGE STAPLES 12 O.C. FIELD NAILING AND 3" PERIMETER NAILING. SEE FOUNDATION PLAN FOR STHD14 STRAP LOCATIONS. 6. ROOF SYSTEM TO BE PRE-ENGINEERED MANUFACTURED WOOD TRUSSES. SEE TRUSS MANUFACTURER LAYOUTS AND SPECIFICATIONS FOR INSTALLATION. 7. USE TEMPERED GLAZING IN DOORS, SLIDING PATIO DOORS, STORM DOORS, SHOWER & BATH ENCLOSURES, WINDOWS WHERE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN 48" OF A VERTICAL EDGE OF AN ACTIVE DOOR AND FIXED PANELS GREATER THAN 9 SO FT WITH THE LOWEST EDGE LESS THAN 18" ABOVE FLOOR. 8. IN COMBUSTIBLE CONSTRUCTION, FIRE BLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS - BOTH VERTICAL AND HORIZONTAL - AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY & THE ROOF SPACE. 9. IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS UNUSABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOORICEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQ.FT. 10. PORTABLE FIRE EXTINGUISHERS TO BE INSTALLED IN ACCORDANCE TO NFPA 10 AND IBC SECTION 906. © 2020 COPYRIGHT McCARTER-MOORHOUSE & 12.15 DESIGN, LLC. THESE PLANS MAY NOT BE USED BY ANY OTHER ENTITY THAN McCARTER-MOORHOUSE & 12.15 DESIGN, L-C. WITHOUT PRIOR WRITTEN CONSENT. V U CV � ARCHITECT STAMP T9022YO N O Q Zz Z Q J Lu W 5 i L NQ LL O 1..� of Qm Q J L2 Z Q J O O J LL Z Q VERIFY SCALES THIS BAR IS 1 INCH ON ORIGINAL DRAWING 0 �1" IF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLY CHECKED DATE 02.01.2022 DRAWN JESSICA JOB NO. 001 SHEET NUMBER A2.1 04