This document's an nslrumenl of sere ce and as such
remains the properly of the Architect Permission for use
of this document is limited and can be odended only by
written agreement with EVstudio LLC
REVISION:
Project Status
DATE: Issue Date
DRAWN BY: AAB
CHECKED BY: Checker
FIRST FLOOR
PLAN
FIRST F
1 3/16" = 1'-0"
H
-00
Cp
OF 0
-Ir EO
0
"66
a3,
FLOOR
-1
0" 3'-8" 3'-6" FT-6" 5'-0" 5'-0" 1'-8" 3'-4" 1'-10" Al 0 1
10 '1 1
FLOOR PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF
MASONRY U.N.O.
2. PARTITION LEGEND PROVIDED HERE IS FOR
REFERENCE. REFER TO SHEET A050 FOR MORE
DETAILED INFORMATION REGARDING PARTITION TYPES
& ASSEMBLIES.
3. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL
INFORMATION REGARDING STUD TYPE, SIZE &SPACING
AND SHEAR WALL LOCATIONS.
4. SEE UL DETAILS ON G-SERIES SHEETS FOR
ADDITIONAL INFORMATION RELATED TO FIRE -RELATED
ASSEMBLY REQUIREMENTS.
5. SEE BUILDING ELEVATIONS ON A20-SERIES SHEETS
AND WALL SECTIONS ON A31-SERIES SHEETS FOR
EXTERIOR WALL ASSEMBLY INFORMATION.
6. SEE WALL SECTIONS ON A31-SERIES SHEETS FOR
HORIZONTAL ASSEMBLY INFORMATION.
7. INTERIOR DOOR FRAMES SHALL BE LOCATED 4-
INCHES FROM FINISHED FACE OF ROOM CORNER TO
FACE OF OPENING U.N.O.
MODIFIER LEGEND
A PARTITION INCLUDES SOUND ATTENUATION
BATT INSULATION
AA PARTITION INCLUDES SOUND ATTENUATION
BATT INSULATION & 1/2-INCH RESILIENT
CHANNELS ON CORRIDOR SIDE
S STRUCTURAL SHEAR WALL WITH SHEAR PANEL
ON ONE (1) SIDE OR SINGLE SEPTUM FACE OF
DOUBLE STUD ASSEMBLIES
SS STRUCTURAL SHEAR WALL WITH SHEAR PANEL
ON BOTH SIDES OR BOTH SEPTUM FACES OF
DOUBLE STUD ASSEMBLIES
I PARTITION INCLUDES THERMAL BATT
INSULATION AS PART OF AN INSULATED
EXTERIOR WALL ASSEMBLY
PARTITION LEGEND
3-5/8" METAL STUDS W/ ONE (1) LAYER 5/8-
GYP. GYP. BD. EACH SIDE TO 6" ABOVE CEILING
3-518" METAL STUDS W/ ONE (1) LAYER 5/8" GYP.
�
BD. CORRIDOR SIDE TO 6" ABOVE CEILING AND
ONE LAYER (1) 5/8" GYP. BD. ROOM SIDE FULL
A
HT. &SOUND ATTENUATION BA:
O3-5/8"
METAL STUDS W/ ONE (1) LAYER 5/8"
GYP. BD. EACH SIDE FULL HT.
79
8" CMU W/ METAL LATH &STUCCO
BUILDING R-VALUE ANALYSIS:
EXT.WALLS:R-21 BATT INSULATION
ROOFS: R-38 CONT. RIGID INSULATION
FOUNDATION: N/A
FLOOR:
WINDOWS: SEE COMCHECK REQUIREMENTS
DOORS: SEE COMCHECK REQUIREMENTS
1
5
BB,_o„
4'-0"
24'-0"
30'-1"
26'-6"
15'-10" 2'-8" 11'-0"
11'-0" 11
35'-6 3/8"
1'-0" 5'-0" 3'-0" 5'-0" 1'-10 5'-6" 6'-0" 5'-0" 6'-01 0" 5'-0" 3'-2"
0" 3'-5" 3'S" 5'-0" 3'-5" 5'-0" 1'-31/2"
4'-0" 5'-r_
A O 1
OB
OB
OB
B
A
o
A301
I BOARD ROOM
I
� N
OA 0 0
109
MEMBER
O �
a
LOUNGE
c0
(V
IJ
OFFICE OFFICE
3
1oa DA OFFICE
0
�
v
eD
O �
L
p
21 CCUPANTS
N
104 106 108A
33 3
109 33 A
r
A A
33 A
r
N q
103A �
OFFICE
110 aQ
3 A 3 A
105 107
= =
O q
°P
u' A 3 � 9'-4" 10'-0In " 10'-0"
10'