Loading...
HomeMy WebLinkAboutT-1, Title Sheet V1(�j�ERO)IANg- APPROVED ■ CAM.OMM2 nFNMWR:^I ve r i - VERIZON SITE NUMBER: 269916 VERIZON SITE NAME: CROSSROADS MALL SITE TYPE: MONOPOLE TOWER HEIGHT: 50'-0" SITE INFORMATION CROWN CASTLE USA INC. SITE NAME: MERIDIAN_ RETAIL SITE ADDRESS: 3100 E. FLORENCE STREET, SUITE 100 MERIDIAN, ID 83642 COUNTY: ADA MAP/PARCEL #: R0375650030 AREA OF CONSTRUCTION: EXISTING LATITUDE: 43.617506 / 43° 37' 3.0216" N LONGITUDE: -116.355636 / 116° 21' 20.2896" W LAT/LONG TYPE: NAD83 GROUND ELEVATION: 2608 FT ± AMSL CURRENT ZONING: I-L JURISDICTION: CITY OF MERIDIAN OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: IIB A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER: N/A TOWER OWNER: CARRIER/APPLICANT: ELECTRIC PROVIDER: TELCO PROVIDER: CROWN CASTLE LLC 2000 CORPORATE DRIVE CANONSBURG, PA 15317 VERIZON WIRELESS 1515 E. WOODFIELD ROAD SCHAUMBURG, IL 60173 IDAHO POWER CENTURYLINK PROJECT TEAM A&E FIRM: CROWN CASTLE USA INC. 2000 CORPORATE DRIVE CANONSBURG, PA 15317 CROWNAE.APPROVAL@CROWNCASTLE.COM CROWN CASTLE 3530 TORINGDON WAY, SUITE 300 USA INC. DISTRICT CHARLOTTE, NC 28277 CONTACTS: MOISES.MENDEZ MOISES.MENDEZ@CROWNCASTEL.COM TBD - CONSTRUCTION MANAGER zone BUSINESS UNIT #: SITE ADDRESS: COUNTY: JURISDICTION: VERIZON FUZE PROJECT #: 16586594 DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES C-1 COMPOUND PLAN C-2 TOWER ELEVATION & ANTENNA PLANS C-3 EQUIPMENT SCHEDULES C-4 EQUIPMENT DETAILS C-5 EQUIPMENT DETAILS C-6 PLUMBING DIAGRAM G-1 GROUNDING DETAILS G-2 GROUNDING DETAILS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 22"X34". CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. APPROVALS SIGNATURE DATE CONTRACTOR PMI REQUIREMENTS PMI ACCESSED AT https://pmi.vxwsmart.com SMART TOOL VENDOR PROJECT NUMBER ---- VzW LOCATION CODE (PSLC) ---- *** PMI AND REQUIREMENTS ALSO EMBEDDED IN MOUNT I ANALYSIS REPORT J MOUNT MODIFICATION REQUIRED I N VzW APPROVED SMART KIT VENDORS REFER TO MOUNT MODIFICATION DRAWINGS PAGE FOR VzW SMART KIT APPROVED VENDORS 825952 3100 E. FLORENCE STREET, SUITE 100 MERIDIAN, ID 83642 ADA CITY OF MERIDIAN LOCATION MAP IF CarMax Q F Ui 4 Fairview Ave E Fairview Ave E Fairviev Ave E Fairview Ave Texas Roadhouse E Fairview Ave r'66 QUS Foods CHEF'STORE re CHEFSTOREDelivery aWalmartSupercenter 2 • © Apparel E Jewel St Q ' Albertsons Market Street s set` C•rvt ; Fl orencc Or c a World Market Q r E Con9ressiaral0. 2 y E English Dr Goodwood Barbecue Company �•� f gQ EStondxid or 'bbew,r n. I E'sery, E Presidential Dr °k 0 E PrNia,_. E Belfast Say Dr Blue Cross of Idaho EState Ave EState Ave Z NO SCALE DRIVING DIRECTIONS FROM VERIZON LOCAL OFFICE (1515 WOODFIELD RD, SCHAUMBURG, IL 60173) TAKE E HIGGINS RD AND FRONTAGE RD TO I-290 E, HEAD SOUTH, TURN RIGHT TOWARD E HIGGINS RD, TURN LEFT TOWARD E HIGGINS RD, TURN RIGHT ONTO E HIGGINS RD, MAKE A U-TURN AT N MEACHAM RD, USE THE RIGHT 2 LANES TO TURN RIGHT ONTO FRONTAGE RD, FOLLOW I-88 W, I-80 W AND I-84 W TO MERIDIAN. TAKE EXIT 46 FROM I-84 W, MERGE WITH I-290 E, KEEP LEFT AT THE Y JUNCTION TO CONTINUE ON I-355 S, FOLLOW SIGNS FOR JOLIET, TAKE THE EXIT TOWARD I-88 W, KEEP LEFT TO CONTINUE TOWARD I-88 W, USE ANY LANE TO TAKE THE RAMP ONTO I-88 W, TAKE EXIT 1B TO MERGE WITH I-80 W TOWARD DES MOINES, KEEP RIGHT AT THE Y JUNCTION TO STAY ON I-80 W, FOLLOW SIGNS FOR COUNCIL BLUFFS/OMAHA, KEEP LEFT TO STAY ON I-80 W, TAKE EXIT 168 FOR I-84 W TOWARD OGDEN, CONTINUE ONTO I-84 W, KEEP LEFT TO STAY ON I-84 W, FOLLOW SIGNS FOR BOISE, TAKE EXIT 46 TO MERGE WITH ID-55 N/S EAGLE RD TOWARD EAGLE/MCCALL, FOLLOW ID-55 N/S EAGLE RD TO E FLORENCE DR, MERGE WITH ID-55 N/S EAGLE RD, TURN LEFT ONTO E FLORENCE ST, TURN RIGHT ONTO E FLORENCE DR, TURN RIGHT TO STAY ON E FLORENCE DR, TURN LEFT TO STAY ON E FLORENCE DR, DESTINATION WILL BE ON THE LEFT APPLICABLE CODES/REFERENCE DOCUMENTS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2018 IBC MECHANICAL 2017 IMC ELECTRICAL 2017 NEC REFERENCE DOCUMENTS: STRUCTURAL ANALYSIS: BY OTHERS DATED: MOUNT ANALYSIS: MASER CONSULTING DATED: 11 /23/2021 RFDS REVISION: N/A DATED: 11 /18/2021 ORDER ID: 597809 REVISION: 0 ® CALL IDAHO ONE CALL (800) 342-1585 6�. CALL 3 WORKING DAYS BEFORE YOU DIG! PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. TOWER SCOPE OF WORK: • REMOVE (6) ANTENNAS • INSTALL (9) ANTENNAS • INSTALL (3) RRHs • RELOCATE (6) RRHs • RELOCATE (6) PIPE MOUNT GROUND SCOPE OF WORK: • INSTALL (1) BBU 6648 NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER ' J verizo m 180 WASHINGTON VALLEY ROAD BEDMINSTER, NJ 07921 CCCROWN CASTLE 1200 MACARTHUR BLVD, SUITE 200 MAHWAH, NJ 07430 rylon On .0 1825 W. WALNUT HILL LANE, SUITE 120 IRVING, TEXAS 75038 VERIZON SITE NUMBER: 269916 BU #: 825952 MERIDIAN_RETAIL 3100 E. FLORENCE STREET, SUITE 100 MERIDIAN, ID 83642 EXISTING 50'-0" MONOPOLE ISSUED FOR: REV DATE DR" DESCRIPTION DES./Q 0 01/13/22 PSK FINAL AMC 1 02/08/22 HAM FINAL AMC cliff Digitally signed by cliff abernathy abernath Date:2022.02.08 05'00' SS�ON L EN N 3 o O F \9 -Z, -�, 'c ABE04N' IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: T-1 1