Loading...
HomeMy WebLinkAboutT-1, Title Sheet V1(�j�ERO)IANg- APPROVED CAME OMM2 FU NIANER:— verlzonV VERIZON SITE NUMBER: 683734 VERIZON SITE NAME: SAMBA SITE TYPE: MONOPOLE TOWER HEIGHT: 118'-2" SITE INFORMATION CROWN CASTLE USA INC. MCRAE_MERIDIAN SITE NAME: SITE ADDRESS: 508 BOWER STREET MERIDIAN, ID 83642 COUNTY: ADA MAP/PARCEL #: R1042250070 AREA OF CONSTRUCTION: EXISTING LATITUDE: 43° 36' 30.17" (43.608375°) LONGITUDE: -116- 23' 12.10" (-116.386745°) LAT/LONG TYPE: NAD83 GROUND ELEVATION: 2602 FT CURRENT ZONING: I-L JURISDICTION: CITY OF MERIDIAN OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: IIB A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER: CELL TOWEWRS LLC PO BOX 8600 BEND, OR 97708 TOWER OWNER: CROWN CASTLE 2000 CORPORATE DRIVE CANONSBURG, PA 15317 CARRIER/APPLICANT: VERIZON WIRELESS 1515 E. WOODFIELD ROAD SCHAUMBURG, IL 60173 PROJECT TEAM A&E FIRM: RAMAKER & ASSOCIATES, INC. 855 COMMUNITY DRIVE SAUK CITY, WI 53583 (608) 643-4100 CONTACT: JOSH OPSETH, PROJECT MANAGER EMAIL: JOPSETH@RAMAKER.COM CROWN CASTLE 1505 WESTLAKE AVENUE NORTH, SUITE 800 USA INC. DISTRICT SEATTLE, WA 98109 CONTACTS: TBD - PROJECT MANAGER TBD - CONSTRUCTION MANAGER VERIZON DAN FAGAN CONTACT: DANIEL.FAGAN@VERIZONWIRELESS.COM BUSINESS UNIT #: SITE ADDRESS: COUNTY: JURISDICTION: VERIZON FUZE PROJECT #: 16122791 DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES C-1 SITE PLAN C-2 TOWER ELEVATION & ANTENNA PLANS C-3 EQUIPMENT SCHEDULES C-4.1 - C4.8 EQUIPMENT DETAILS C-5 PLUMBING DIAGRAM C-6 SECTOR EQUIPMENT LAYOUT DETAIL G-1 GROUNDING DETAILS G-2 GROUNDING DETAILS G-3 GROUNDING DETAILS G-4 GROUNDING DETAILS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 2X34. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. APPROVALS SIGNATURE DATE CONTRACTOR PMI REQUIREMENTS PMI ACCESSED AT https://pmi.vxwsmart.com SMART TOOL VENDOR PROJECT NUMBER ---- VzW LOCATION CODE (PSLC) 683734 *** PMI AND REQUIREMENTS ALSO EMBEDDED IN MOUNT I ANALYSIS REPORT J MOUNT MODIFICATION REQUIRED I N VzW APPROVED SMART HIT VENDORS REFER TO MOUNT MODIFICATION DRAWINGS PAGE FOR VzW SMART KIT APPROVED VENDORS Fronuer uub Food Bank Q W Broadway A- E Broadway A- z a Meridian Main Street Market z W.Rmkoad St. Rmiroad M ; 6, —BruneelPoint S� A a z • E� E aawK si � Bobbys� Transmission Center 4 NAPA Auto Parts Q -Dyna Parts E Ado St 1 ti� Hungry Onion Drive -Inn P. e� P6 Idaho Youth� 9BirdieBird Pet Store Ranch Thrift Store 825767 508 BOWER STREET MERIDIAN, ID 83642 ADA CITY OF MERIDIAN LOCATION MAP — PrecisionCraft Log Bui de 9 Homes & Timber Frame \ z; W E Bowe st l E Bower S2 W �ABFFI� Supply Co Inc I Q Caliber Collision Indepth Detailing BoiseQ Q build your own detail Big Twin Diesel QBlue Wrench Nw 3rd ss E Niny A fEagle Guitar g Fresh Air Manufacturing Co (FAMCO)O E cO'^m bpi a ECatnmi.u�. Legacy Martial PAUL DAVIS RESTORATION OF.. QBK Industries Japanese car specialist NO SCALE DRIVING DIRECTIONS FROM BOISE, ID AIRPORT: HEAD WEST ON W AIRPORT WAY TOWARD S OWYHEE ST 443 FT. SLIGHT RIGHT ONTO S OWYHEE ST 479 FT. TURN LEFT ONTO W WRIGHT ST 1.1 MI. TURN RIGHT ONTO S ORCHARD ST 0.2 MI. USE THE LEFT 2 LANES TO TURN LEFT TO MERGE ONTO I-84 W TOWARD NAMPA/CALDWELL 0.5 MI. MERGE ONTO I-84 W 1.1 MI. KEEP LEFT TO STAY ON I-84 W 5.7 ML TAKE EXIT 44 FOR ID-69 TOWARD MERIDIAN KUNA 0.6 MI. KEEP RIGHT AT THE FORK, FOLLOW SIGNS FOR MERIDIAN AND MERGE ONTO S MERIDIAN RD 486 FT. MERGE ONTO S MERIDIAN RD 0.2 MI. CONTINUE ONTO S MAIN ST 0.7 MI. CONTINUE STRAIGHT ONTO N MAIN ST 0.1 MI. TURN RIGHT ONTO E BOWER ST 0.2 MI. TURN LEFT ONTO SITE ACCESS DIVE 0.1 MI. APPLICABLE CODES/REFERENCE DOCUMENTS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2018 IBC MECHANICAL 2018 IMC ELECTRICAL 2017 NEC REFERENCE DOCUMENTS: STRUCTURAL ANALYSIS: BY OTHERS DATED: MOUNT ANALYSIS: BY OTHERS DATED: RFDS REVISION: 1 DATED: 10/ 12/2021 ORDER ID: 579086 REVISION: 0 CALL IDAHO ONE CALL p (800) 342-1585 p CALL 3 WORKING DAYS �1✓Q BEFORE YOU DIG! PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. TOWER SCOPE OF WORK: • INSTALL (3) ANTENNA SECTOR FRAMES • INSTALL (12) ANTENNAS • INSTALL (9) RRHs • INSTALL (3) OVP BOX • INSTALL (3) HYBRID CABLE (2") GROUND SCOPE OF WORK: • INSTALL (1) EQUIPMENT PAD • INSTALL (1) RF CABINET • INSTALL (1) BATTERY CABINET • INSTALL (1) EQUIPMENT UTILITY RACK • INSTALL (1) EQUIPMENT CANOPY • INSTALL (1) GENERATOR • INSTALL (3) OVP BOX • INSTALL (1) ICE BRIDGE NOTE: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGER veriZonN11 1515 E. WOODFIELD ROAD SCHAUMBURG, IL 60173 CROWN Co,aC CASTLE 1 CITY PLACE DRIVE, SUITE 490 ST. LOUIS, MO 63141 RAMAKER employee -owned (608) 643-4100 www.ramaker.com PROJECT #: 53375 VERIZON SITE NUMBER: 683734 BU #: 825767 MCRAE_MERIDIAN 508 BOWER STREET MERIDIAN, ID 83642 EXISTING 118'-2" MONOPOLE ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q A 11/23/2021 SLS PRELIMINARY IMO 0 11/30/2021 AMW FINAL IMO 1 02/09/2022 AMW OVP IMO I hereby certdy that this plan, sp—fi-t—, or report was prepared by me under my direct supenn — and that I am a duly Licensed Professional Engmeer under the laws of the 5tate of Idaho. 4 2/09/2022 T"r5�y,at e. Date: RamekerB Associates lnc_ lectronic copy ina document, ongina sealed document rnth: IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: T-1 1