HomeMy WebLinkAboutC-4.4, Equipment Layout Detail V1DwRIDn-
APPROVEEDDD
-._ OM&2z
R
:w
min
19'-0"
CONCRETE PAD WITH GENERATOR
15'-0"
CONCRETE PAD WITHOUT GENERATOR
5'-1 1/2" 1 6'-7 3/4" 6'-7 3/4"
I POST TO q POST I POST TO CE POST
13'-0"
CANOPY
6" 2'-6" 3'-0"I I '-6"
1 PLINTH
4'-0"
N Z
I �
�a
2 -0 I 1
I
O O O u O
• 000 000 O O O O O O 000 000
FUTURE BATTERY RF 1
— CABINET • CABINET CABINET
I
• o • • • •
Ll
0 0 0 0 0
I
�o
STEEL POST (W,f) �
WEATHER CANOPY PERFECT VISION
PV-W-CW1014-B OR EQUAL
MOUNT GPS ANTENNA ON HIGH
SIDE OF CANOPY CLOSEST TO
THE EQUIPMENT CABINET TO
SHORTEN THE CABLE RUN
7" 1 '-O"
0 0 0
0
O
O
O
ILC
UTILITY METER &
DISC. SWITCH
ATTACHED
O TO H-FRAME
O (L
3'-0"
CLEARANCE
NEW SERVICE LIGHT
MOUNTED AT 8' A.F.G.
TO H-FRAME POST (TYP. OF 2)
O a -
I Z
o Q
U
verizonv'
1515 E. WOODFIELD ROAD
SCHAUMBURG, IL 60173
CCCRC WN
CASTLE
1 CITY PLACE DRIVE, SUITE 490
ST. LOUIS, MO 63141
RAMAKE R
employee -owned
(608) 643-4100 www.ramaker.com
L PROJECT #: 53375
VERIZON SITE NUMBER:
683734
BU #: 825767
MCRAE_MERIDIAN
508 BOWER STREET
MERIDIAN, ID 83642
EXISTING 118'-2" MONOPOLE
ISSUED FOR:
REV
DATE
DR"
DESCRIPTION
DES./Q
A
11/23/2021
SLS
PRELIMINARY
JMO
0
11/30/2021
AMW
FINAL
JMO
1
02/09/2022
AMW
OVP
JMO
I hereby certify that this plan, sp—f—tlo or report was prepared
by me or under my dared supennsion and that I am a duly Licensed
professonal Engineer under the laws of the State of Idaho.
210912022
ig ao e. Dace:
Ramalcer 8 Assotla4es Inc
lectronic copy ma document, origma sealed dowmerR wrath:
IT IS A VIOLATION OF LAW FOR ANY PERSON,
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
SHEET NUMBER: REVISION:
`J EQUIPMENT LAYOUT DETAIL
SCALE: NOT TO SCALE NC-404