Loading...
HomeMy WebLinkAboutConstruction Drawings - C8.10 V1= - 0 m 8' ACHD EASMENT R/W 50' PUBLIC RIGHT—OF—WAY R/W 8' ACHD EASEMENT dL COLLECTOR ROAD STREET SECTION 2 R/W 2 I 5' SIDEWALK 8' PLANTER 2' FLAT LANDING BEHIND SIDEWALK, TYP. 3 LOCAL ROAD TYPICAL SECTION 36' TYPICAL STREET SECTION WITH DETACHED SIDEWALK W. HARRIS ST. & S. OAKBRIAR DR. 60' PUBLIC RIGHT—OF—WAY 16.50' 3" ROLLED CURB AND GUTTER PER ACHD SD-702 TYP. _.. 2 .0% 8" THICK CONCRETE RIBE CURB (T) SCALE: NTS 2 COMMON DRIVE TYPICAL SECTION R[W 16.50' I 8' PLANTER I 5' SIDEWALK I I 2.07 _ 3" ASPHALT PAVEMENT- / 4" OF COMPACTED I" CRUSHED AGGREGATE BASE COURSE 17" OF COMPACTED 6" MINUS PIT RUN SUBBASE COMPACTED SUBGRADE 33' TYPICAL LOCAL STREET SECTION WITH DETACHED SIDEWALK 1�_51. 5" THICK CONCRETE OVER 4" OF J" AGGREGATE BASE COURSE PER ACHD SD-709 INLET FROM SAND AND GREASE TRAP INLET FROM SAND AND 18" SOLID WALL PVC PIPE GREASE TRAP INVERT PER PLAN INLET FROM DIVERSION 12" SOLID WALL PVC PIPE MANHOLE INVERT PER PLAN 0pll2[� 5' LANDSCAPE BUFFER I u ur wwAu I tU X CRUSHED AGGREGATE BASE COURSE COMMON DRIVE TYPICAL SECTION NO TREES OR SHRUBS OVER SEEPAGE BED SEEPAGE BED PROFILE VIEW 18" PERFORATED PVC PIPE INVERT PER PLAN 12" PERFORATED PVC PIPE INVERT PER PLAN ------------------------------------ - — — — — — — — — — — SEEPAGE BED PLAN VIEW 1. SEE TABLE FOR SEEPAGE BED DIMENSIONS 2. CONTACT DESIGN ENGINEER FOR SEEPAGE BED REDESIGN IF GROUNDWATER IS ENCOUNTERED ABOVE MAX HSGW ELEVATION. 3. ALL VAULTS, MANHOLES, & SAND AND GREASE TRAPS SHALL BE HS25 OR GREATER LOAD RATED. 4. ALL GEOTEXTILE SEAMS SHALL OVERLAP 1 FOOT MINIMUM 5. EL. IN >= EL. BOTTOM PERFORATIONS IN 12" PERFORATED PIPE. 6. BED WIDTH SHALL REMAIN CONSTANT SCALE: NTS z M \/HIGH GROUND WATER z 0 a o' U U w H Q m 04 N LLJ - M Q LLJ 00 � 0 ' O z - J LU O a cn o w LPL p m Lu J cf) LL Q J � < U = /n v � o 3 II N N N Z 0 0 0 z N N N O Lu J a a U 10' MIN. U) a a m 0 CD 00 MONITORING WELL } m m Z 03 m 0 1-- co z w o a U) w O 0 U a SEAL STORM WATER RETENTION SUMMARY TABLE NAME LENGTH (ft) WIDTH (ft) DEPTH (ft) TOP OF ROCK ELEV. BOTTOM OF ROCK ELEV. GROUNDWATER ELEV. REQ'D SEPARATION (3' MIN) DESIGN INFILTRATION RATE (IN/HR) SEEPAGE BED 1 53 10 10 2710.0 2700.0 ±2697.0 YES 8.00 SEEPAGE BED 2 48 10 10 2710.2 2700.2 ±2696.9 YES 8.00 SEEPAGE BED 3 286 10 10 2711.5 2701.5 ±2698.0 YES 8.00 SEEPAGE BED 4 232 10 10 2712.9 2702.9 ±2698.9 YES 8.00 SCALE: NTS 4 SEEPAGE BED DETAIL SS\ONAL &V, \,\CENSF, ? �n 8670 9TF OF 0 �B�GA IL \4' SHEET C8.10 SCALE: NTS