HomeMy WebLinkAboutSite Plan_C2.00 V1FITNESS
135
DECON
131
AIR ROOM
130
HALLWAY
127
RESTROOM
129
APPARATUS BAY
124
STORAGE
126
COMMUNICATIONS
125
IT
109
HALLWAY
105
HALLWAY
102
VESTIBULE
100
RESTROOM
101
PATIO
FIRE RISER
114
ELECTRICAL
113
LAUNDRY
112
JANITOR
110
RESTROOM
115
RESTROOM
116
RESTROOM ADA
117
HALLWAY
111
CAPTAIN SLEEP
118
SLEEP
119
SLEEP
120
SLEEP
121
SLEEP
122
SLEEP
123
DAYROOM
108
CAPTAIN OFFICE
104
FFWA
103
BUNKER GEAR
132
WORKSHOP
134
WASH ALCOVE
133
HOSE STOR.
128
VAN
DO NOT ENTER
TRASH/RECYCLE
GEN
EP EP
EP EP EP EP EP EP EP EP EP EP
IV
IV
IV
MW
MB
IV
IV
IV IV
IV
IV
MB
X
X X
X
X X
X
X
OHP
OHP OHP OHP
T T T T T T T T
T
T
T T T
T
T T
T
T
T T
T
T
T
T
T T
T T T T T T T T T T T T T
OHP
OHP OHP OHP
OHP
OHP OHP
OHP OHP
OHP
OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP
W
W
W W W W
W
W
W W
W
W W W
W
W W
W
W W
W
W W
W
W W W W W W W
W W
W W
E
E
E
E
IRR
IRR
IRR
IRR
IRR
IRR
S00°02'18"W 500.00'
S89°58'22"E 348.63'
WMTR
WV
W
S.5
S.32
N89°58'22"W 348.48'
N00°01'18"E 500.00'
R/W R/W
R/W
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
R/W
R/W R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W R/W R/W
R/W
R/W R/W R/W R/W
R/W
R/W R/W R/W R/W
R/W
25'
OHP OHP OHP
T T T T T
T T T
T
T
T
T T
T T
T
T
T
T T T
T T
T T
T T T T
T
T
T
T
T
T
T
T T
E
E
EMTR
(TYP.)
(BY OTHERS)
1
4 4
4
5
7
11
12
12
12
13.1
13.2
15
15
14
14
14
14
10
10
10
10
10 10
9
9
4
4
4
4
8
6
3
3
3
3
3
16
(TYP.)
13.1
(TYP.)
13.1
2
6'
10' SETBACK
12' SETBACK
19'
(TYP.)
25'
SETBACK
R15.5'
R15.5'
26'
R28'
R54'
R15.5'
R20'
60.3'
9 SPACES AT 9-FT O.C. =
81'
6 SPACES @ 9-FT O.C. =
9' 9' 54'
19'
(TYP.)
4'
6'
15.3'
25'
LANDSCAPE BUFFER
R6'
19'
(TYP.)
10.5' 26'
87.67'
129.1'
6'
26'
R54'
R28'
26'
26'
6.5'
6'
8 SPACES @ 9-FT O.C. =
72'
R6'
R6'
R6'
R4'
R28'
25'
6.5'
6.5'
8.3'
R54'
139.9'
5.5'
14.23'
18.97'
R25'
R4.5'
R6'
184.27'
38.5'
17.89'
14.5'
16'
12'
18
141.58'
67.48'
79.01'
234.51'
3
TYP. OF 3 13.1
MIN. 20'
LANDSCAPE
BUFFER
143'
6.5'
14.85'
5.49'
60.15'
4
Horizontal Scale:
0 20' 40'
1" = 20'
Site Plan
Keynotes:
Sheet Notes:
PROPOSED
FIRE STATION
P r o j e c t :
S h e e t N a m e :
P r o j e c t N o :
D r a w n B y :
C h e c k e d B y :
D a t e :
R e v i s i o n s :
S h e e t N o :
STAMP:
PIVOT NORTH ARCHITECTURE, PLLC.
1101 W. GROVE STREET
BOISE, ID 83702
www.pivotnorthdesign.com
1 2 3 4 5 6
A
B
C
D
E
CONSTRUCTION
NOT FOR
File Location: g:\2020\120157\cad\czc c2.00 site plan 120157.dwg
Last Plotted By:david duperault
Date Plotted: Friday, October 29 2021 at 02:14 PM
TLG PN: 120157
20-050
CR/DD/JL
EC/BS
10/29/2021
SOUTH MERIDIAN FIRE STATION #7
2385 E. LAKE HAZEL ROAD, MERIDIAN, ID 83642
CZC SET - 10/29/2021 (NOT FOR CONSTRUCTION)
Site Plan
C2.00
Material Legend
LANDSCAPE AREA - REFER TO L1.00 FOR ADDITIONAL
INFORMATION
STANDARD CONCRETE FLATWORK
HEAVY DUTY CONCRETE FLATWORK
LIGHT DUTY ASPHALT PAVING
#
1. FLAG POLE
2. ADA PEDESTRIAN PATHWAY PER UDC 11-3A-19-4.
3. SITE LIGHT POLE, BY SITE ELECTRICAL
4. PEDESTRIAN RAMP PER ISPWC OR ACHD SUPPLEMENTAL
SPECIFICATIONS
5. ADA PARKING STALL
6. ELECTRICAL GENERATOR AND FUEL TANK BY ARCHITECT / SITE
ELECTRICAL
7. BICYCLE RACK (2 EACH) PER DETAIL THIS SHEET
8. 6-YD TRASH BIN / WHEEL TOTE RECYCLING ENCLOSURE - REFER TO
ARCHITECTURAL DRAWINGS FOR DETAILS
9. DRIVEWAY APPROACH, BY OTHERS
10. 10-FT CONCRETE SIDEWALK, BY OTHERS
11. STRIPED FITNESS PAD
12. DO NOT ENTER AND/OR ONE-WAY SIGNAGE PER MUTCD
13. PAVEMENT MARKING
13.1. PARKING STALL STRIPE
13.2. ADA PARKING
14. STREET SIGNAGE, BY OTHERS
15. STREET LIGHT, BY OTHERS
16. ELECTRICAL TRANSFORMER, BY SITE ELECTRICAL / IDAHO POWER
17. REMOVABLE BOLLARD
18. EXISTING IRRIGATION PUMP HOUSE FOR DISCOVERY PARK. IRRIGATION
SERVICE FOR PROPOSED DEVELOPMENT WILL BE EXTENDED FROM
PRESSURE IRRIGATION MAINLINE ADJACENT TO COMMON BOUNDARY.
REFER TO AUTOMATED UNDERGROUND IRRIGATION NOTES, THIS SHEET.
Curb and Gutter Legend
CURB AND CATCH PLATE GUTTER
CURB AND REVERSE PLATE GUTTER
VERTICAL CURB
ROLLED CURB AND GUTTER
Project Information:
APPLICANT
NAME: CITY OF MERIDIAN
REPRESENTATIVE
CITY OF MERIDIAN - PUBLIC WORKS DEPARTMENT
33 E BROADWAY AVENUE, SUITE 200
MERIDIAN, ID 83642
CONTACT: STACY REDMAN | FACILITIES PROJECT MANAGER
PHONE: 208.489.0374
LANDSCAPE ARCHITECT, CIVIL ENGINEER, LAND SURVEYOR
COMPANY: THE LAND GROUP, INC
CONTACT: BOB SCHAFER, PLA (PROFESSIONAL LANDSCAPE ARCHITECT)
CONTACT: ERIC CRONIN, PE (CIVIL ENGINEER)
CONTACT: MIKE FEMENIA, PLS (PROFESSIONAL LAND SURVEYOR)
ADDRESS: 462 E. SHORE DR., SUITE 100
EAGLE, IDAHO 83616
PHONE: 208.939.4041
Project Calculations:
PROPERTY SIZE: 174,279 SF / ±4.00 ACRES
PROPOSED BUILDING SIZE: 11,560 SF
PARKING CALCULATIONS:
REQUIRED PROPOSED
PARKING STALLS: 23-EA 24-EA
ACCESSIBLE PARKING STALLS: 1-EA 1-EA
BICYCLE PARKING SPACES: 1-EA 4-EA
Zoning Regulations:
LEGAL DESCRIPTION: MERIDIAN RURAL FIRE PROTECTION DISTRICT
2385 E LAKE HAZEL ROAD, MERIDIAN, IDAHO 83642
APN#: S1405212420
CURRENT ZONING: R-8
PROPOSED ZONING: R-8 (NO CHANGE)
FRONT SETBACK: 25-FT
REAR SETBACK: 12-FT
INTERIOR SIDE SETBACK: 10-FT
LANDSCAPE BUFFERS:
STREET: 25-FT FROM EAST LAKE HAZEL ROAD (ENTRYWAY CORRIDOR)
20-FT FROM PROPOSED RECREATION AVE.
RESIDENTIAL USES: (NOT APPLICABLE TO SITE)
MAXIMUM BUILDING HEIGHT: 35-FT
1. DERO HOOP RACK, COLOR: STAINLESS STEEL. INSTALL PER MANUFACTURER'S SPECIFICATIONS.
NOTE:
INSTALL SURFACE MOUNT PER
MANUFACTURER'S REQUIREMENTS
10"
THICKENED CONCRETE FLATWORK
4" DEPTH BASE COURSE
36"
1
Dero Hoop Bicycle Rack
Scale: NTS
1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE MEASURED FROM FACE OF
CURB, EDGE OF WALK, EDGE OF PAVEMENT, EDGE OF FOUNDATION, EDGE OF
WALLS OR CENTER OF POST.
2. FUTURE COLLECTOR ROADWAY, RECREATION AVE., WILL BE DESIGNED AND
CONSTRUCTED BY OTHERS. LAYOUT AND ITEMS NOTED "BY OTHERS" ARE
SUBJECT TO CHANGE.
A. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLER
SYSTEM WHICH ENSURES COMPLETE COVERAGE AND PROPERLY ZONED FOR
REQUIRED WATER USES.
B. EACH HYDROZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS.
C. POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 18" AT
PLANTER BEDS, 6" AT LAWN AREAS..
D. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEMS - WITH DRIP CONTROL
ZONE KIT AND 150 MESH FILTER (MIN.).
E. ELECTRONIC WATER DISTRIBUTION/ TIMING CONTROLLERS ARE TO BE PROVIDED.
MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS:
E.A. PRECISE INDIVIDUAL STATION TIMING
E.B. RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES
E.C. AT LEAST ONE PROGRAM FOR EACH HYDROZONE
E.D. SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF
E.E. POWER FAILURE BACKUP FOR ALL PROGRAMMED INDIVIDUAL VALVED
WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE
WATER TO RESPECTIVE HYDRO-ZONES.
F. INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO
PROVIDE WATER TO RESPECTIVE HYDRO-ZONES.
G. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% COVERAGE WITH
HEAD TO HEAD SPACING OR TRIANGULAR SPACING AS APPROPRIATE.
H. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO
IMPERVIOUS SURFACES SUCH AS SIDEWALKS, DRIVEWAYS, AND PARKING AREA.
I. EACH VALVE SHALL BE INSTALLED IN A VALVE BOX LARGE ENOUGH TO ALLOW FOR
MAINTENANCE AND REMOVAL. ONLY ONE VALVE PER BOX.
Automatic Underground Irrigation Notes:
01/13/22
A-2021-0215