Loading...
HomeMy WebLinkAboutSite Plan_C2.00 V1FITNESS 135 DECON 131 AIR ROOM 130 HALLWAY 127 RESTROOM 129 APPARATUS BAY 124 STORAGE 126 COMMUNICATIONS 125 IT 109 HALLWAY 105 HALLWAY 102 VESTIBULE 100 RESTROOM 101 PATIO FIRE RISER 114 ELECTRICAL 113 LAUNDRY 112 JANITOR 110 RESTROOM 115 RESTROOM 116 RESTROOM ADA 117 HALLWAY 111 CAPTAIN SLEEP 118 SLEEP 119 SLEEP 120 SLEEP 121 SLEEP 122 SLEEP 123 DAYROOM 108 CAPTAIN OFFICE 104 FFWA 103 BUNKER GEAR 132 WORKSHOP 134 WASH ALCOVE 133 HOSE STOR. 128 VAN DO NOT ENTER TRASH/RECYCLE GEN EP EP EP EP EP EP EP EP EP EP EP EP IV IV IV MW MB IV IV IV IV IV IV MB X X X X X X X X OHP OHP OHP OHP T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W E E E E IRR IRR IRR IRR IRR IRR S00°02'18"W 500.00' S89°58'22"E 348.63' WMTR WV W S.5 S.32 N89°58'22"W 348.48' N00°01'18"E 500.00' R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 25' OHP OHP OHP T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T E E EMTR (TYP.) (BY OTHERS) 1 4 4 4 5 7 11 12 12 12 13.1 13.2 15 15 14 14 14 14 10 10 10 10 10 10 9 9 4 4 4 4 8 6 3 3 3 3 3 16 (TYP.) 13.1 (TYP.) 13.1 2 6' 10' SETBACK 12' SETBACK 19' (TYP.) 25' SETBACK R15.5' R15.5' 26' R28' R54' R15.5' R20' 60.3' 9 SPACES AT 9-FT O.C. = 81' 6 SPACES @ 9-FT O.C. = 9' 9' 54' 19' (TYP.) 4' 6' 15.3' 25' LANDSCAPE BUFFER R6' 19' (TYP.) 10.5' 26' 87.67' 129.1' 6' 26' R54' R28' 26' 26' 6.5' 6' 8 SPACES @ 9-FT O.C. = 72' R6' R6' R6' R4' R28' 25' 6.5' 6.5' 8.3' R54' 139.9' 5.5' 14.23' 18.97' R25' R4.5' R6' 184.27' 38.5' 17.89' 14.5' 16' 12' 18 141.58' 67.48' 79.01' 234.51' 3 TYP. OF 3 13.1 MIN. 20' LANDSCAPE BUFFER 143' 6.5' 14.85' 5.49' 60.15' 4 Horizontal Scale: 0 20' 40' 1" = 20' Site Plan Keynotes: Sheet Notes: PROPOSED FIRE STATION P r o j e c t : S h e e t N a m e : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : STAMP: PIVOT NORTH ARCHITECTURE, PLLC. 1101 W. GROVE STREET BOISE, ID 83702 www.pivotnorthdesign.com 1 2 3 4 5 6 A B C D E CONSTRUCTION NOT FOR File Location: g:\2020\120157\cad\czc c2.00 site plan 120157.dwg Last Plotted By:david duperault Date Plotted: Friday, October 29 2021 at 02:14 PM TLG PN: 120157 20-050 CR/DD/JL EC/BS 10/29/2021 SOUTH MERIDIAN FIRE STATION #7 2385 E. LAKE HAZEL ROAD, MERIDIAN, ID 83642 CZC SET - 10/29/2021 (NOT FOR CONSTRUCTION) Site Plan C2.00 Material Legend LANDSCAPE AREA - REFER TO L1.00 FOR ADDITIONAL INFORMATION STANDARD CONCRETE FLATWORK HEAVY DUTY CONCRETE FLATWORK LIGHT DUTY ASPHALT PAVING # 1. FLAG POLE 2. ADA PEDESTRIAN PATHWAY PER UDC 11-3A-19-4. 3. SITE LIGHT POLE, BY SITE ELECTRICAL 4. PEDESTRIAN RAMP PER ISPWC OR ACHD SUPPLEMENTAL SPECIFICATIONS 5. ADA PARKING STALL 6. ELECTRICAL GENERATOR AND FUEL TANK BY ARCHITECT / SITE ELECTRICAL 7. BICYCLE RACK (2 EACH) PER DETAIL THIS SHEET 8. 6-YD TRASH BIN / WHEEL TOTE RECYCLING ENCLOSURE - REFER TO ARCHITECTURAL DRAWINGS FOR DETAILS 9. DRIVEWAY APPROACH, BY OTHERS 10. 10-FT CONCRETE SIDEWALK, BY OTHERS 11. STRIPED FITNESS PAD 12. DO NOT ENTER AND/OR ONE-WAY SIGNAGE PER MUTCD 13. PAVEMENT MARKING 13.1. PARKING STALL STRIPE 13.2. ADA PARKING 14. STREET SIGNAGE, BY OTHERS 15. STREET LIGHT, BY OTHERS 16. ELECTRICAL TRANSFORMER, BY SITE ELECTRICAL / IDAHO POWER 17. REMOVABLE BOLLARD 18. EXISTING IRRIGATION PUMP HOUSE FOR DISCOVERY PARK. IRRIGATION SERVICE FOR PROPOSED DEVELOPMENT WILL BE EXTENDED FROM PRESSURE IRRIGATION MAINLINE ADJACENT TO COMMON BOUNDARY. REFER TO AUTOMATED UNDERGROUND IRRIGATION NOTES, THIS SHEET. Curb and Gutter Legend CURB AND CATCH PLATE GUTTER CURB AND REVERSE PLATE GUTTER VERTICAL CURB ROLLED CURB AND GUTTER Project Information: APPLICANT NAME: CITY OF MERIDIAN REPRESENTATIVE CITY OF MERIDIAN - PUBLIC WORKS DEPARTMENT 33 E BROADWAY AVENUE, SUITE 200 MERIDIAN, ID 83642 CONTACT: STACY REDMAN | FACILITIES PROJECT MANAGER PHONE: 208.489.0374 LANDSCAPE ARCHITECT, CIVIL ENGINEER, LAND SURVEYOR COMPANY: THE LAND GROUP, INC CONTACT: BOB SCHAFER, PLA (PROFESSIONAL LANDSCAPE ARCHITECT) CONTACT: ERIC CRONIN, PE (CIVIL ENGINEER) CONTACT: MIKE FEMENIA, PLS (PROFESSIONAL LAND SURVEYOR) ADDRESS: 462 E. SHORE DR., SUITE 100 EAGLE, IDAHO 83616 PHONE: 208.939.4041 Project Calculations: PROPERTY SIZE: 174,279 SF / ±4.00 ACRES PROPOSED BUILDING SIZE: 11,560 SF PARKING CALCULATIONS: REQUIRED PROPOSED PARKING STALLS: 23-EA 24-EA ACCESSIBLE PARKING STALLS: 1-EA 1-EA BICYCLE PARKING SPACES: 1-EA 4-EA Zoning Regulations: LEGAL DESCRIPTION: MERIDIAN RURAL FIRE PROTECTION DISTRICT 2385 E LAKE HAZEL ROAD, MERIDIAN, IDAHO 83642 APN#: S1405212420 CURRENT ZONING: R-8 PROPOSED ZONING: R-8 (NO CHANGE) FRONT SETBACK: 25-FT REAR SETBACK: 12-FT INTERIOR SIDE SETBACK: 10-FT LANDSCAPE BUFFERS: STREET: 25-FT FROM EAST LAKE HAZEL ROAD (ENTRYWAY CORRIDOR) 20-FT FROM PROPOSED RECREATION AVE. RESIDENTIAL USES: (NOT APPLICABLE TO SITE) MAXIMUM BUILDING HEIGHT: 35-FT 1. DERO HOOP RACK, COLOR: STAINLESS STEEL. INSTALL PER MANUFACTURER'S SPECIFICATIONS. NOTE: INSTALL SURFACE MOUNT PER MANUFACTURER'S REQUIREMENTS 10" THICKENED CONCRETE FLATWORK 4" DEPTH BASE COURSE 36" 1 Dero Hoop Bicycle Rack Scale: NTS 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE MEASURED FROM FACE OF CURB, EDGE OF WALK, EDGE OF PAVEMENT, EDGE OF FOUNDATION, EDGE OF WALLS OR CENTER OF POST. 2. FUTURE COLLECTOR ROADWAY, RECREATION AVE., WILL BE DESIGNED AND CONSTRUCTED BY OTHERS. LAYOUT AND ITEMS NOTED "BY OTHERS" ARE SUBJECT TO CHANGE. A. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICH ENSURES COMPLETE COVERAGE AND PROPERLY ZONED FOR REQUIRED WATER USES. B. EACH HYDROZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS. C. POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 18" AT PLANTER BEDS, 6" AT LAWN AREAS.. D. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEMS - WITH DRIP CONTROL ZONE KIT AND 150 MESH FILTER (MIN.). E. ELECTRONIC WATER DISTRIBUTION/ TIMING CONTROLLERS ARE TO BE PROVIDED. MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS: E.A. PRECISE INDIVIDUAL STATION TIMING E.B. RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES E.C. AT LEAST ONE PROGRAM FOR EACH HYDROZONE E.D. SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF E.E. POWER FAILURE BACKUP FOR ALL PROGRAMMED INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO-ZONES. F. INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO-ZONES. G. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% COVERAGE WITH HEAD TO HEAD SPACING OR TRIANGULAR SPACING AS APPROPRIATE. H. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES SUCH AS SIDEWALKS, DRIVEWAYS, AND PARKING AREA. I. EACH VALVE SHALL BE INSTALLED IN A VALVE BOX LARGE ENOUGH TO ALLOW FOR MAINTENANCE AND REMOVAL. ONLY ONE VALVE PER BOX. Automatic Underground Irrigation Notes: 01/13/22 A-2021-0215