Markle, James <JMarkle@republicservices.com>
1/13/22Saturday, October 30, 2021 12:27 PM
BER:^-zwvozie Smith, Bruce C; Eric Cronin
c: James Leo; David Duperault; Mike Schubert
Subject: Re: Meridian Fire Station 7 - Trash Enclosure Approval
With 2 recycle totes you are good with 16'
Sent via the Samsung Galaxy S10e, an AT&T 5G Evolution capable smartphone
Get Outlook for Android
From: Eric Cronin <eric@thelandgroupinc.com>
Sent: Saturday, October 30, 2021 1:21:15 PM
To: Markle, James <JMarkle@republicservices.com>; Smith, Bruce C <SMITHBR9@republicservices.com>
Cc: James Leo <james@thelandgroupinc.com>; David Duperault <dduperault@thelandgroupinc.com>; Mike Schubert
<mschubert@rfmarch.com>
Subject: RE: Meridian Fire Station 7 - Trash Enclosure Approval
Note that (eric@thelandgroupinc.com) is an external email. Report suspicious emails by clicking on "Report
Phishing"
Jay,
Thanks for getting back to us. We can expand to 20' wide but were thinking we only need 16' per the clip
below. Reference attached standards received back in May 2021. We plan to have (1) 6-CY dumpster and (2) recycle
totes, 95-gal max. Please let us know if we need to expand or are okay as currently shown?
Two containers:
(1) 3, 6, or 8-yard
dumpster,
and one grease
container or up to two
95-gallon carts
Thanks,
professional engineer
eric Cronin, p.e.
ith
a 16'-wide gate
opening
THE LAND GROUP I thelandgroupinc.com
o. 208.939.40411 d.208.817.3416
Must open at least Minimum four-inch-
120 degrees, and thick reinforced
have a mechanism to concrete with an apron,
hold them in the sized to fit the
open position enclosure
From: Markle, James <JMarkle@republicservices.com>
Sent: Friday, October 29, 2021 6:00 PM
To: Eric Cronin <eric@thelandgroupinc.com>; Smith, Bruce C <SMITHBR9@republicservices.com>
Cc: James Leo <james@thelandgroupinc.com>; David Duperault <dduperault@thelandgroupinc.com>; Mike Schubert
�E IDIAN--
c
APPROVED
DATE: 01/13/22
FILE NUMBER: a 021-0 s
rch.com>
an Fire Station 7 - Trash Enclosure Approval
n Eric,
irad is out of the office and therefore you didn't receive a reply.
Bruce and I spoke and everything looks great with the approach. We just ask the following:
The depth of 12 ft is good but if you have trash and recycle we need the width to be 20ft
instead of 16ft. If you plan on having only trash then 16ft is great.
We don't per say stamp plans but rather give approval via e-mail.
Republic Services gives approval for the plans as they are with the addition of 4ft to the width
of the enclosure if you plan to have 2 containers.
Thanks
Jay
From: Eric Cronin <eric@thelandgroupinc.com>
Sent: Thursday, October 28, 2021 6:29 AM
To: Markle, James <JMarkle@republicservices.com>; Smith, Bruce C <SMITHBR9@republicservices.com>
Cc: James Leo dames@thelandgroupinc.com>; David Duperault<dduperault@thelandgroupinc.com>; Mike Schubert
<mschubert@rfmarch.com>
Subject: RE: Meridian Fire Station 7 - Trash Enclosure Approval
Note that (eric@thelandgroupinc.com) is an external email. Report suspicious emails by clicking on "Report
Phishing"
Good Morning Gentleman,
Our delay in submittal is not intended to burden, you so I apologize if that is the case. I wanted to follow up and see if
review or the proposed project is something we can expect this week? If not, I just want to inform our client so we can
plan alternately.
Regards -
professional engineer
eric Cronin, p.e.
THE LAND GROUP I thelandgroupinc.com
o. 208.939.4041 1 d. 208.817.3416
IN
CUEIDR IAN,--
�J tober 26, 2021 5:55 PM
APPROVED ublicservices.com; SMITHBR9@republicservices.com
DATE 01/13/22 mes theland rou inc.com>; David Duperault<dduperault@thelandgroupinc.com>; Chad Reitze
ou inc.com) <chad@thelandgroupinc.com>; Mike Schubert <mschubert@rfmarch.com>
FILE NUMBER: n-zozvozis
Fire Station 7 - Trash Enclosure Approval
James & Bruce -
Please find the attached exhibit containing the site plan and trash enclosure details for the subject project located at
2385 E Lake Hazel Road in Meridian adjacent to Discovery Park. We are proposing a single enclosure for dumpster and
(2) recycle containers. Exact volumes/sizes to be coordinated further as owner needs are understood. The site will take
access off of a proposed ACHD collector roadway along the eastern side of the parcel. Actual address is pending. We
are submitting for a City of Meridian Certificate of Zoning Compliance application at the end of the week and need site
plan review and approval from you in order to submit. Could you please review the attached and provide needed
stamped site plan?
Two containers:
16' X 12' with
Must open at least
Minimum four-inch-
3, 6, or 8-yard
a 16'-wide gate
120 degrees, and
thick reinforced
dumpster,
opening
have a mechanism to
concrete with an apron,
and one grease
hold them in the
sized to fit the
container or up to two
open position
enclosure
95-gallon carts
We just learned of the desired Friday (10/29) submittal this afternoon and would appreciate any attention you could put
to this request in the coming days. Do not hesitate to contact our office should you have any questions or require
additional information.
Best Regards -
professional engineer
eric Cronin, p.e.
THE LAND GROUP I thelandgroupinc.com
o. 208.939.40411 d. 208.817.3416