L3.1_Irrigation Control Details V1
1 2 3 4 5 6 7 9 10 12 POWER SOURCE FROM UTILITY COMPANY IRRIGATION CONTROLLER SERVICE ENTRANCE GROUND BUS BAR FUSE OR CKT BRKR BLACK (LINE OR HOT) WHITE (NEUTRAL) TO GREEN OR BARE (EQUIPMENT GROUND) OTHER 11 CONTROLLERS EARTH GROUND BY SUPPLEMENTARY THE UTILITY COMPANY GROUND SUPPLEMENTARY GROUNDING NOT TO SCALE 4" x 96" GROUNDING PLATE 6 AWG SOLID BARE COPPER WIRETI \ CONTROLLER 1 \ PLASTIC U o SWEEP ELL (1 1/2" OF LARGER) CONCRETE TOP VIEW 10, PAD =1I _' III=III=III- -III _ III —III CADWELD GT1161G "ONE-SHOT" W/ IGNITER Z III1 I I-1 I I-1 11- � NOTES5/8"x10'COPPER CLAD GROUND RODS SHALL HAVE A MIN. DIA. OF 5/8" AND A GROUND ROD LENGTH OF 10'. THE COPPER GROUNDING PLATES SHALL BE MADE ACCORDING TO THE MINIMUM REQUIREMENTS OF SECTION 250 OF THE NEC THEY ARE TO BE MADE OF -- COPPER ALLOY INTENDED FOR THE APPLICATION AND THE PLATE SHALL MEASURE 4"x96"x.0625". A 25' t CONTINUOUS LENGTH OF 4 AWG BARE COPPER WIRE 4" x 96" GROUNDING PLATE SHALL BE PROVIDED WITH THE PLATE ASSEMBLY AND SHALL BE ATTACHED TO THE PLATE USING AN APPROVED CONCRETE MIXTURE WELDING PROCESS. THIS WIRE IS TO BE CONNECTED TO AND THROUGH THE TOP OF THE GROUND ROD USING A 6 AWG SOLID BARE COPPER CADWELD GT1161G "ONE-SHOT" WELDING KIT. THE WIRE GROUND PLATE SHALL BE INSTALLED TO A MINIMUM DEPTH OF 30", OR BELOW THE FROST LINE IF IT IS BELOW 30". THE POWERSET EARTH GROUNDING MATERIAL SHALL EXOTHERMIC WELDING PROCESS BY UTILIZING BE SPREAD SO THAT IT SURROUNDS THE COPPER PLATE PRODUCTS SUCH AS THE CADWELD "ONE-SHOT' KITS. EVENLY ALONG ITS LENGTH WITHIN A 6" WIDE TRENCH. SOLDER SHALL NOT BE ALLOWED TO MAKE THE EARTH -TO -GROUND RESISTANCE OF THIS CIRCUIT CONNECTIONS. THE WIRES ARE TO BE INSTALLED IN AS SHALL BE MEASURED USING A MEGGER OR OTHER STRAIGHT OF A LINE AS POSSIBLE, AND IF IT IS SIMILAR INSTRUMENT, AND THE READING SHALL BE NO NECESSARY TO MAKE A TURN OR A BEND IT SHALL BE MORE THAN 10 OHMS. IF THE RESISTANCE IS MORE DONE IN A SWEEPING CURVE RATHER THAN A SHARP THAN 10 OHMS, THEN ADDITIONAL GROUND PLATES AND BEND. MECHANICAL CLAMPS SHALL BE PERMITTED POWERSET SHALL BE INSTALLED IN THE DIRECTION OF TEMPORARILY DURING THE RESISTANCE TEST PROCESS, THE IRRIGATION AREA. TO PREVENT THE BUT SHALL BE REPLACED WITH CADWELD "ONE-SHOT" ELECTRODE -DISCHARGED ENERGY FROM RE-ENTERING KITS IMMEDIATELY THEREAFTER. IT IS RECOMMENDED THE UNDERGROUND WIRES AND CABLES, ALL THAT THE SOIL SURROUNDING ALL THE COPPER ELECTRODES SHALL BE INSTALLED AWAY FROM SAID ELECTRODES BE KEPT AT A MINIMUM MOISTURE LEVEL OF WIRES AND CABLES. THE SPACING BETWEEN ANY TWO 15%. THE USE OF SALTS, FERTILIZERS, AND OTHER ELECTRODES SHALL BE 16 TO 20 FEET SO THAT THEY CHEMICALS SHALL NOT BE ALLOWED IN AN EFFORT TO DON'T COMPETE FOR THE SAME SOIL. ALL GROUND IMPROVE SOIL CONDUCTIVITY BECAUSE THESE CIRCUIT CONNECTIONS SHALL BE MADE USING AN MATERIALS ARE CORROSIVE AND WILL CAUSE THE COPPER ELECTRODES TO BECOME INEFFECTIVE. CONTROL GROUND GRID NOT TO SCALE FRONT VIEW SIDE VIEW LEGEND: 1. STRONG BOX SB16SS CONTROLLER ENCLOSURE 2. 120-VOLT SERVICE IN EXISTING CONDUIT. 3. CONCRETE PAD - 4" MIN. THICKNESS. EXTEND CONCRETE 6" BEYOND OUTSIDE DIMENSIONS OF ENCLOSURE WITH 1/2 % SLOPE FOR DRAINAGE. 4. EXISTING CONDUIT 5. DIRECT BURIAL CONTROL WIRES TO CONTROL VALVES. 6. FINISH GRADE 7. CONTROLLER SUB -ASSEMBLY (CSA) INCLUDES GFI & TERMINAL STRIPS WITH PLACARDS. 8. AUTOMATIC CONTROLLER. CONTROLLER PEDESTAL NOT TO SCALE I1 I J K LOCATE LIGHTING ARRESTOR 10' AWAY FROM GROUNDING ROD CONTROL WIRES TO SENSOR OR REMOT CONTROL VALVE PER PLAN. ID WIRE PATH TWISTED TO NEXT DECODER DBY (2) TWO WIRES TO VALVE SOLENOID/UP TO 150FT./45M ICD DECODER, CONNECT DECODER TO #4 REBAR WITH TWO STAINLESS STEEL STRAPS. EXTEND REBAR A MIN. OF 18" BELOW GRAVEL. DBY-6 (3) ID WIRE PATH FROM CONTROLLER ALLOW 5 ft/1.5M SLACK PER DECODER/1/2 ON EITHER SIDE OF DECODER TO EARTH GROUND INSTALLED PER ASIC GUIDELINES. 1 PER 12 DECODERS OR EVERY 1000ft./330M. SEE DETAIL. ICD DECODER WIRING AT CONTROL VALVE Scale: NTS STANDARD VALVE BOX FINISH GRADE MIN. 18/2 WIRE TO ACC POWER MODULE. MAXIMUM WIRE DISTANCE RUN OF 1,000' FLOW SENSOR AS SPECIFIED `MAIN LINE PIPE FLOW SENSOR HOUSING AS SPECIFIED NOTE: INLET PIPE LENGTH OF SENSOR MUST BE MIN. 10X PIPE DIA. STRAIGHT, CLEAN RUN OF PIPE, NO FITTINGS OR TURNS. OUTLET PIPE LENGTH OF SENSOR MUST BE MIN. 5X PIPE DIA. OF STRAIGHT CLEAN RUN OF PIPE, NO FITTINGS OR TURNS. FLOW SENSOR Scale: NTS SOLAR SYNC SENSOR SUITABLE POST, POLE, GUTTER MOUNT MOUNT IN LOCATION THAT MAXIMIZES DIRECT SUNLIGHT, OPEN TO RAINFALL AND OUT OF SPRINKLER SPRAY PATTERN CONDUIT FROM SOLAR SYNC SENSOR TO CONTROLLER OR TO A POINT 12" BELOW GRADE, AS REQUIRED. SOLAR SYNC MODULE MOUNT LESS THAN 6' AWAY FROM CONTROLLER. AS REQUIRED. COMMUNICATION WIRE, 18-2(WIRE TYPE TO MEET INSTALLATION CODE REQUIREMENTS), FROM MODULE TO SENSOR. MAXIMUM TOTAL WIRE DISTANCE, 200 FEET SOLAR SYNC INSTALATION WIRELESS RAIN/FREEZE TRANSMITTER; INSTALLED NO MORE THAN 1000' AWAY FROM RECEIVER. SUITABLE BUILDING LOCATION, POST, POLE, GUTTER MOUNT. MOUNT IN LOCATION THAT IS OPEN TO DIRECT RAINFALL AND OUT OF SPRINKLER SPRAY PATTERN WIRELESS RAIN/FREEZE RECEIVER; MOUNT LESS THAN 6' AWAY FROM CONTROLLER. AS REQUIRED. WIRELESS RAIN/FREEZE CLIK SYSTEM Scale: NTS Scale: NTS /---10" ROUND VALVE BOX III III - BARE COPPER GROUNDING WIRE. —CAD-WELD TO GROUNDING ROD. —GROUNDING ROD 5/8" x 8' COPPER CLAD ROD DRIVEN 8' INTO EARTH. —PAVING BRICK OR 2"x4" REDWOOD GROUNDING RODS ARE TO ONLY BE INSTALLED IN LOCATIONS NOTED ON IRRIGATION PLAN OR WITHIN EVERY 1,000 FEET. DECODER/ GROUNDING ROD U ASSEMBLY INLET VALVE OUTLET VALVE 90° ELL NIPPLES TEE WITH 1" PLUG FOR SPRINKLER BLOWOUT WITH AIR COMPRESSOR BRASS UNION TYPICAL 24" x 75" x 39" ALUMINUM ENCLOSURE BY STRONG BOX, MODEL #SBBC-75ALHP. MOUNT TO CONCRETE PAD PER MANUFACTURING RECOMMENDATIONS. PROVIDE LOCKING KIT. FINISH GRADE 6" DIA. ROUND VALVE BOX , 4" CONCRETE PAD, I I I SIZE AS REQUIRED TO PROVIDE 3" ON ALL SIDES OF ENCLOSURE IIII I=' II 6" CLASS 200 PVC —I- I III- SLEEVE III II I I= PVC LINE TO SYSTEMS I II FLOC 1110 In MANUAL DRAIN VALVE (REQUIRED ONLY IF LINE SLOPES TOWARD THREAD MOUNT, MAXIMUM H2O WATER MAXIMIZER ALUMINUM. SIZE TO MATCH MAINLINE. (PROVIDE HOLE IIN PAD FOR DRAINING III — FILTER. ALIGN HOLE — WITH FILTER DRAIN. - 10" PERF. :� I PVC PIPE N .I FILTER, FABRIC FILTER) 6" DIA. 12" DEEP DRAIN BED' WITH 2" GRAVEL FOR DRAIN VALVE. WRAP WITH FILTER FABRIC AUTOMATIC 2", 'AMIAD' MINISIGMA ON-LINE AUTOMATIC CLEANING FILTER, WITH ADI-P CONTROLLER AND 130 MICRON FILTRATION. NOTE: 1. ALL PIPES AND FITTINGS USED FOR FILTER ASSEMBLY TO BE MADE OF RED BRASS. 2. ENSURE APPROPRIATE CLEARANCE FOR FILTER REMOVAL. 3. CONNECT TO 120 VOLT AS REQUIRED. ALL ABOVE GRADE WIRES SHALL BE LOCATED IN APPROPRIATELY SIZED CONDUIT (2" MINIMUM). IRIGATION CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH CERTIFIED ELECTRICAL CONTRACTOR FOR ALL ELECTRICAL CONNECTIONS. 3'W x 6'L x 2' DEPTH III DRYWELL WITH III III FILTER FABRIC AND 1 DRAIN ROCK IN - ADDITION TO 10" DIAMETER x 24" FROM — - III DRAIN BED TO Qc ACCOMODATE FLOW ELL -ICAL) — III- OFF FILTER, WHICH —III IS ESTIMATED @ 6.3 III _ _ GALLONS PER EACH �IIIIIIIIIIII-III-IIIII FLUSH x4-5TIMES PER DAY DEPENDING ON QUALITY OF WATER SOURCE. SELF CLEANING FILTER NOT TO SCALE WIRE SPLICE E VECTORS (SPLICE ALL WIRE SUPER SERVISEAL iF WIRE SPLICE KIT IED CABLE. LEAVE 24" SLACK ) NEATLY IC BARRIER GRAVEL SUMP NOT TO SCALE 12" DIA. HEAVY DUTY PLASTIC VALVE BOX WITH LOCKING LID DBM OR DBY CONNECTORS AS REQUIRED. HUNTER ICD DECODER PER PLANS CONNECT DECODER TO REBAR WITH TWO STAINLESS STEEL STRAPS. TWO WIRE COMMUNICATION WIRES FILTER FABRIC BARRIER TO ENCOMPASS ROCK VALVE BOX EXTENSION AS REQUIRED PAVING BRICK OR 2"x4" REDWOOD 6" DEEP PEA GRAVEL SUMP TWO WIRE COMMUNICATION WIRE PATH TO FOLLOW MAINLINE IN TRENCH #4 REBAR TO EXTEND A MIN. OF 18" BELOW GRAVEL. NOT TO SCALE 1 2 3 4 5 6 7 8 9 10 1p� STAMP: 0000F 0%, �p 6 !O %, S� M 0. Mio 00000 0000o o� % ov, LA-276o �o0�Q 11/4/21 oo�I , 0cM0 �V000 DATE: 11/04/2021 {� fMCW q y �MOF OW zW�nip'' yVCR S '/ C aOQY 1 no�a2g ou WW og �xiis v > F-1 - o o a � rn u u a W N l blip o .i v � m 6 o'oow N O] N C '_ Q u c 3ra OWa .a NCIO NI C Y N W a ccMR � a t h an O H O Copyright © 2021 _1 reserved. ReproOucllon or use In any NI "a �waavreea"Aw, e" oS-th�f nann s@ce m seace aRn�ern,re P c°°°s .—Iand noie<r"e"m�"ai w":ee"aore REVISIONS: No. Date Description W co 00 W � H AO" a -I ax� p Z C—� O Z O [� cc Z O V u� 1�1 O .1.1 ta Z DRAWN BY: JRB CHECKED BY: JCsM PROJECT NUMBER 21-048 SHEET: L3.1 a J a Lu w a A B C D E F G H J K L M N 0 P